• Title/Summary/Keyword: Direct Sampling

Search Result 463, Processing Time 0.026 seconds

Structure of Direct RF Sampling Receivers for GNSS Signals

  • Won, Yu-Jun;Ahn, Woo-Hyun;Lee, MinJoon;Park, Chansik;Seo, Bo-Seok
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.3 no.3
    • /
    • pp.91-97
    • /
    • 2014
  • A direct RF sampling method refers to a technique that directly converts a passband signal to an intermediate band or a baseband without using a mixer. This method is less complicated than an existing RF receiver because a mixer is not used. It uses digital processing after sampling, and thus can flexibly process signals in a number of bands using software. In this process, it is important to select an appropriate sampling frequency so that a number of signals can be converted to an intermediate band that is easy to process. In this study, going beyond previously studied direct RF sampling frequency selection methods, conditions that need to be additionally considered during receiver design were examined, and the structure of a direct RF sampling receiver that satisfies these conditions was suggested.

A Comparative Study Between Light Extinction and Direct Sampling Methods for Measuring Volume Fractions of Twin-Hole Sprays Using Tomographic Reconstruction

  • Lee, Choong-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.1986-1993
    • /
    • 2003
  • The spatially resolved spray volume fractions from both line-of-sight data of direct measuring cells and a laser diffraction particle analyzer (LDPA) are tomographically reconstructed by the Convolution Fourier transformation, respectively. Asymmetric sprays generated from a twin-hole injector are tested with 12 equiangular projections of measurements. For each projection angle, a line-of-sight integrated injection rate was measured using a direct sampling method and also a liquid volume fraction from a set of line-of-sight Fraunhofer diffraction measurements was measured using a light extinction method. Interpolated data between the projection angles effectively increase the number of projections, significantly enhancing the signal-to-noise level in the reconstructed data. The reconstructed volume fractions from the direct sampling cells were used as reference data for evaluating the accuracy of the volume fractions from the LDPA.

Work Measurement through Application of Work Sampling in Hospital Dietary Departments Classified by the Productivity Level (급식생산성 유형별 병원 영양과의 워크샘플링 (Work Sampling)을 적용한 작업분석)

  • 양일선
    • Journal of Nutrition and Health
    • /
    • v.26 no.4
    • /
    • pp.443-454
    • /
    • 1993
  • The purposes of this study were to analyze the work patterns of selected hospital foodservices by Work Sampling methodology, and to investigate the relationship among operational factors affecting productivity. The hospitals were classified into 3 groups by the percentage of patient meals, and the percentage of special patient diet, and the menu items of patients meals. The groups clustered were characterized by productivity. Work Sampling methodology was utilized to analyze the work patterns of hospitals with selected 3 hospitals to investigate the productivity the productivity and labor times used in each work functions. Productivity index analyzed by Work Sampling were 10.36 min/meal, 10.95 min/meal, and 12.19 min/meal, respectively X, Y, Z hospital. Z hospital was significantly different from time used in direct work function and delay. Direct work function time was the highest, delay the lowest in Z hospital. The relation between the results of Work Sampling and the productivities of 3 groups showed not by delay but direct work function in the classification used in this study.

  • PDF

Direct Shear Test of Undisturbed Weathered Residual Soils (불교란 풍화잔적토의 직접전단시험)

  • 오세붕;이영휘;정종혁
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.423-430
    • /
    • 1999
  • A weathered residual soil is a soil-like material derived from the in situ weathering and decomposition of rock which has not been transported from its original location. Undisturbed sampling of residual soils is extremely difficult, which has an important effect on investigating the strength and compression characteristics. Thus, a special undisturbed sampling device (direct shear box with shoe) was developed and undisturbed samples were successfully obtained for direct shear tests, Direct shear testing was conducted under unsoaked and soaked condition. As a result, the shear strength of soaked samples was less than that of unsoaked samples, and it was verified that direct shearing of undisturbed samples can evaluate reasonably the shear strength and the slope stability.

  • PDF

Atmospheric Bioaerosol, Bacillus sp., at an Altitude of 3,500 m over the Noto Peninsula: Direct Sampling via Aircraft

  • Kobayashi, Fumihisa;Morosawa, Shinji;Maki, Teruya;Kakikawa, Makiko;Yamada, Maromu;Tobo, Yutaka;Hon, Chun-Sang;Matsuki, Atsushi;Iwasaka, Yasunobu
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.3
    • /
    • pp.164-171
    • /
    • 2011
  • This work focuses on the analysis of bioaerosols in the atmosphere at higher altitudes over Noto Peninsula, Japan. We carried out direct sampling via aircraft, separated cultures, and identified present isolates. Atmospheric bioaerosols at higher altitudes were collected using a Cessna 404 aircraft for an hour at an altitude of 3,500 m over the Noto Peninsula. The aircraft-based direct sampling system was devised to improve upon the system of balloon-based sampling. In order to examine pre-existing microorganism contamination on the surface of the aircraft body, bioaerosol sampling was carried out just before takeoff using the same method as atmospheric sampling. Identification was carried out by a homology search for 16S or 18S rDNA isolate sequences in DNA databases (GenBank). Isolate sampling just before takeoff revealed Stretpomyces sp., Micrococcus sp., and Cladosporium sp. One additional strain, Bacillus sp., was isolated from the sample after bioaerosol collection at high altitude. As the microorganism contamination on the aircraft body before takeoff differed from that while in the air, the presence of additional, higher atmosphere-based microorganisms was confirmed. It was found that Bacillus sp. was floating at an altitude of 3,500 m over Noto Peninsula.

Mathematical Approach on Composition of Nomination Committee for University President Election

  • Yi, Sucheol;Heo, Sunyeong
    • Journal of Integrative Natural Science
    • /
    • v.9 no.1
    • /
    • pp.67-71
    • /
    • 2016
  • The university president direct election system in Korea had begun in 1987 as a movement of college democratization in the 1980s after 6.29 Declaration. Since then, many national/private universities had adopted the election system. However, it has posed many problems and it caused a sharp division of opinions between those who approve and disapprove the direct election system. Since 2005, the government has made official of the reformation and/or abolition of the university president direct election system, and has kept pushing for universities to give up the direct election system. Now, only 3 or 4 universities hold on to the system, and many universities have changed into the indirect election system. In the indirect election, a key is the composition of president nomination committee, which confirms the university members's variety. Many universities adopting the indirect election system have used simple random sampling, like drawing lots, to compose the president nomination committee. However, drawing lots has a problem that it has large possibility of composing a biased committee. This research suggests systematic sampling as an alternative to drawing lots. A numerical analysis was conducted using a data of a university in which the indirect election was implemented recently. The drawing lots gave the biased nomination committee. On the other hand, the systematic sample improves the problem and confirms more the variety of all members.

A Complex Bandpass Sampling Method for Downconversion of Multiple Bandpass Signals (다중 대역통과 신호의 하향변환을 위한 Complex Bandpass Sampling 기법)

  • Bae, Jung-Hwa;Ha, Won;Park, Jin-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.9C
    • /
    • pp.913-921
    • /
    • 2005
  • A complex bandpass sampling technique can provide a more flexible architecture for designing a software- defined radio(SDR) system, because it has several advantageous features of larger sampling range and lower minimum sampling frequency than a real bandpass sampling method. In spite of the potential advantages of the complex bandpass sampling, solid investigation for the direct downconversion of multiple signals by the complex sampling theory has not been reported yet. Thus, we propose in this paper a novel scheme for the downconversion of multiple signals using the complex bandpass sampling, and develop the formulae related to the complex bandpass sampling for practical usage, such as the valid sampling range, the intermediate frequency (If), and the minimum sampling frequency of the downconversion of multiple RE signals. Such derived formulae are verified from simulations.

Chorionic villus sampling

  • Shim, Soon-Sup
    • Journal of Genetic Medicine
    • /
    • v.11 no.2
    • /
    • pp.43-48
    • /
    • 2014
  • Chorionic villus sampling has gained importance as a tool for early cytogenetic diagnosis with a shift toward first trimester screening. First trimester screening using nuchal translucency and biomarkers is effective for screening. Chorionic villus sampling generally is performed at 10-12 weeks by either the transcervical or transabdominal approach. There are two methods of analysis; the direct method and the culture method. While the direct method may prevent maternal cell contamination, the culture method may be more representative of the true fetal karyotype. There is a concern for mosaicism which occurs in approximately 1% of cases, and mosaic results require genetic counseling and follow-up amniocentesis or fetal blood sampling. In terms of complications, procedure-related pregnancy loss rates may be the same as those for amniocentesis when undertaken in experienced centers. When the procedure is performed after 9 weeks gestation, the risk of limb reduction is not greater than the risk in the general population. At present, chorionic villus sampling is the gold standard method for early fetal karyotyping; however, we anticipate that improvements in noninvasive prenatal testing methods, such as cell free fetal DNA testing, will reduce the need for invasive procedures in the near future.

Design and Performance of a Direct RF Sampling Receiver for Simultaneous Reception of Multiband GNSS Signals (다중대역 GNSS 신호 동시 수신을 위한 직접 RF 표본화 수신기 설계 및 성능)

  • Choi, Jong-Won;Seo, Bo-Seok
    • Journal of Broadcast Engineering
    • /
    • v.21 no.5
    • /
    • pp.803-815
    • /
    • 2016
  • In this paper, we design a direct radio frequency (RF) sampling receiver for multiband GNSS signals and demonstrate its performance. The direct RF sampling is a technique that does not use an analog mixer, but samples the passband signal directly, and all receiver processes are done in digital domain, whereas the conventional intermediate frequency (IF) receiver samples the IF band signals. In contrast to the IF sampling receiver, the RF sampling receiver is less complex in hardware, reconfigurable, and simultaneously converts multiband signals to digital signals with an analog-to-digital (AD) converter. The reconfigurability and simultaneous reception are very important in military applications where rapid change to other system is needed when a system is jammed by an enemy. For simultaneous reception of multiband signals, the sampling frequency should be selected with caution by considering the carrier frequencies, bandwidths, desired intermediate frequencies, and guard bands. In this paper, we select a sampling frequency and design a direct RF sampling receiver to receive multiband global navigation satellite system (GNSS) signals such as GPS L1, GLONASS G1 and G2 signals. The receiver is implemented with a commercial AD converter and software. The receiver performance is demonstrated by receiving the real signals.