Direct Stator Flux Vector Control Strategy for IPMSM using a Full-order State Observer

  • Yuan, Qingwei;Zeng, Zhiyong;Zhao, Rongxiang
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.236-248
    • /
    • 2017
  • A direct stator flux vector control scheme in discrete-time domain is proposed in this paper for the interior permanent magnet synchronous motor (IPMSM) drive to remove the proportional-integral (PI) controller from the direct torque control (DTC) scheme applied to IPMSM and to obtain faster dynamic response and lower torque ripple output. The output of speed outer loop is used as the desired torque angle instead of the desired torque in the proposed scheme. The desired stator flux vector in dq coordinate is calculated with a given amplitude. The state-space equations in discrete-time for IPMSM are established, the actual stator flux vector is estimated in deadbeat manner by a full-order state observer, and then the closed-loop control is achieved by the pole placement. The stator flux error vector is utilized to calculate the reference stator voltage vector. Extracting the angle position and amplitude from the estimated stator flux vector and estimating the output torque are eliminated for the direct feedback control of the stator flux vector. The proposed scheme is comparatively investigated with a PI-SVM DTC scheme by experiment results. Experimental results show the feasibility and advantages of the proposed control scheme.

고배속 광 디스크 드라이브를 위한 강인 직접 검색 제어 시스템의 구현 (Implementation of Robust Direct Seek Control System for High-Speed Rotational Optical Disk Drives)

  • 진경복;이문노
    • 제어로봇시스템학회논문지
    • /
    • 제8권7호
    • /
    • pp.539-546
    • /
    • 2002
  • This paper presents a new direct seek control scheme that provides fast data access capability and robust performance for high-speed rotational optical disk drives (ODD). When a disk is rotating at a high speed to obtain fast data transfer in ODD, the magnitude and frequency of velocity disturbance caused by eccentric rotation of the disk increase in proportion to the rotational speed of the disk. Such disturbances make it almost impossible for the conventional seek control scheme to achieve stable and satisfactory seek performance. We analyze the problems that may arise when the conventional seek control scheme is applied to the high-speed rotational ODD and propose a new direct seek control scheme that will solve such problems. In the proposed scheme, a seek control system is designed such that its performance is guaranteed for a set of plants with parameter perturbations. The performance of the proposed seek control scheme is shown by experiments using a high-speed rotational ODD.

Direct Power Control Scheme of Improved Command Tracking Capability for PMSG MV Wind turbines

  • Kwon, Gookmin;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.361-362
    • /
    • 2015
  • This paper proposes a Direct Power Control (DPC) scheme of improved command tracking capability for Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) Wind Turbines. Benchmarking is performed based on a neutral point clamped three-level back-to-back type voltage source converter. It is introduced to design the DPC modeling and propose DPC scheme of a three-level NPC (3L-NPC) converter. During the fault condition in wind farms, the proposed control scheme directly controls the generated output power to the command value from the hierarchical wind farm controller. The proposed control scheme is compared with conventional control scheme as respect to loss and thermal analysis. The DPC scheme of improved command tracking capability is confirmed through PLECS simulations. Simulation result shows that proposed control scheme achieves a much shorter transient time in a step response of generated output power. The proposed control scheme makes it possible to provide a good dynamic performance for PMSG MV wind turbine to generate a high quality output power under grid fault condition.

  • PDF

직접순시토크 제어에 의한 SR구동형 유압 펌프시스템의 고성능 압력제어 (A High Performance Pressure Control of SR Type Hydraulic Pump System using Direct Instantaneous Torque Control Method)

  • 안진우
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1751-1756
    • /
    • 2007
  • This paper presents a high performance pressure control scheme for SR(Switched Reluctance) type hydraulic oil pump using DITC(Direct Instantaneous Torque Control). SR drive has a good feature for pump applications due to a high efficiency, high speed and high torque characteristics. But, SR drive has high torque ripple in commutation region. So, the pump pressure variation is high in the region. In order to reduce the pressure variation, DITC combined with pressure control scheme is presented in this paper. A simple PI controller with flow and pressure limit, generates a reference torque to keep the constant actual pump pressure. The direct torque controller of SR drive generates inverter switching signals according to a control rule and a torque estimator. Computer simulation and experiemtal results show the validation of the proposed control scheme.

유도전동기의 직접토크제어 시스템에서 출력전압벡터선정을 위한 시간지연의 보상 (Time Delay Compensation for Output Voltage Vector Selection in Direct Torque Control of Induction Machine)

  • 최병태;박철우;권우현
    • 제어로봇시스템학회논문지
    • /
    • 제9권8호
    • /
    • pp.632-639
    • /
    • 2003
  • This paper proposes a simple compensation scheme for the time delay caused by measurement, calculation and selection of voltage vector in Direct Torque Control (DTC) of an induction motor. In general scheme, it is difficult to know the exact delay time, furthermore the delay time can be varied by program routines for calculation and processing of measured data. In this proposed scheme, by applying voltage vector at the beginning of next sampling period, a fixed delay time is achieved and its compensation becomes much simpler. Furthermore, with the simple compensation algorithm, an improved performance can be achieved by shortening sampling period. Experimental results prove the feasibility of the proposed scheme in induction motor control.

A New Direct Torque Control Scheme of an Induction Motor Using Duty Ratio Modulation

  • Park, Jeong-Woo;Lee, Dong-Myung
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1223-1231
    • /
    • 2018
  • The direct torque control (DTC) scheme features a simple structure thanks to stator flux-oriented control. It has the advantage of robustness against motor parameters variation since only the stator resistance is involved in the control scheme. On the other hand, the disadvantage of DTC is large torque ripple. To reduce the torque ripple, many studies on DTC-space vector modulation (DTC-SVM) schemes, which modulate the duty ratio with a fixed switching cycle, have been proposed. However, there is the difficulty in obtaining the duty ratio for DTC-SVM. Hence, this paper proposes a new duty ratio selection and stator flux calculation methods for reducing torque ripple. Simulations and experiments were carried out to determine the validity of the proposed method. The proposed scheme has simplified the duty ratio command and achieved the same control performance as the conventional duty ratio modulation method without using the information of motor parameters.

직접토크제어 유도전동기 구동 서보시스템을 위한 장치고장 진단 기법 (An Instrument Fault Diagnosis Scheme for Direct Torque Controlled Induction Motor Driven Servo Systems)

  • 이기상;유지수
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권6호
    • /
    • pp.241-251
    • /
    • 2002
  • The effect of sensor faults in direct torque control(DTC) based induction motor drives is analyzed and a new Instrument fault detection isolation scheme(IFDIS) is proposed. The proposed IFDIS, which operated in real-time, detects and isolates the incipient fault(s) of speed sensor and current sensors that provide the feedback information. The scheme consists of an adaptive gain scheduling observer as a residual generator and a special sequential test logic unit. The observer provides not only the estimate of stator flux, a key variable in DTC system, but also the estimates of stator current and rotor speed that are useful for fault detection. With the test logic, the IFDIS has the functionality of fault isolation that only multiple estimator based IFDIS schemes can have. Simulation results for various type of sensor faults show the detection and isolation performance of the IFDIS and the applicability of this scheme to fault tolerant control system design.

유도전동기의 직접 벡터제어 시스템에서 기동기법에 관한 연구 (A Study on the Start-Up Scheme of Direct Vector Controlled Induction Motor System)

  • 전태원;최명규;유우종
    • 전력전자학회논문지
    • /
    • 제5권5호
    • /
    • pp.427-434
    • /
    • 2000
  • 본 논문은 유도전동기의 직접벡터 제어 시스템에서 전동기가 기동 시 토크 충격없이 부드럽게 기동할 수 있는 기동기법을 제시한다. 정지모드에서는 고정자 전류만으로 고정자자속을 계산하는 방식을 사용하며, 기동 후 직접 벡터제어 모드에서는 프로그램어블 3-단계 저역필터로 고정자자속을 계산한다. 정지모드에서 직접벡터제어 모드로 변환 시 3-단계 저역필터의 시간지연으로 고정자 자속이 급격히 감소되어 토크 역시 갑자기 감소된다. 본 논문에서는 전동기가 기동 시 토크 충격을 방지하기 위한 고정자 자속의 피이드포워드 제어 기법을 제시하고, 시뮬레이션 및 실험을 통하여 이 기법의 타당성을 확인한다.

  • PDF

MMC-HVDC 시스템의 예측 기반 직접전력제어 (Predictive Direct Power Control in MMC-HVDC System)

  • 이귀준
    • 전력전자학회논문지
    • /
    • 제23권6호
    • /
    • pp.403-407
    • /
    • 2018
  • This study proposes a predictive direct power control method in a modular multilevel converter (MMC) high-voltage direct-current (HVDC) system. The conventional proportional integral (PI)-based control method uses a cascaded connection and requires an optimal gain selection procedure and additional decoupling scheme. However, the proposed control method has a simple structure for active/reactive power control due to the direct power control scheme and exhibits a fast dynamic response by predicting the future status of system variables and considering time delay. The effectiveness of the proposed method is verified by simulation results.

Application of the Goore Scheme to Turbulence Control for Drag Reduction(I) -Improvement of the Goore Schme-

  • 이창훈;김남현;김준
    • Journal of Mechanical Science and Technology
    • /
    • 제15권11호
    • /
    • pp.1572-1579
    • /
    • 2001
  • We investigate the possibility of application of the Goore Scheme to turbulence control for drag reduction. In Part I, we examine the performance of the original Goore Scheme by applying it to a si mple one-dimensional problem. For the application of the scheme to turbulence control, we extend the scheme's capability so that it can treat multi-dimensional problems and examine its validity theoretically. The convergence of the extended scheme with a dynamic memory is faster by an order of magnitude than the original scheme. In Part II, we apply the proposed scheme to reduce drag for turbulent channel flows through direct numerical simulation.

  • PDF