• 제목/요약/키워드: Direct/Diffuse Decomposition

검색결과 4건 처리시간 0.016초

미세먼지 농도가 직산분리 모델의 신뢰성에 미치는 영향에 관한 연구 (A Study on the Effect of Particulate Matter Concentration on the Reliability of Decomposition Model)

  • 이상혁;이경수
    • 한국태양에너지학회 논문집
    • /
    • 제39권4호
    • /
    • pp.55-67
    • /
    • 2019
  • Recently, as the amount of particulate matter blowing from China increases, the domestic air environment is rapidly deteriorating. This pollution of the atmosphere greatly affects the light energy reaching the ground. Particularly, since the light enters the solar cell module in various forms, the amount of input energy of the solar power generation system may be changed depending on the ratio of direct beam irradiation and diffused horizontal irradiation. In this paper, we analyze how the ratio of direct beam component and diffused component on global horizontal irradiation varies with the atmospheric conditions. In addition, the reliability of the regression equation, designed to decompose the global horizontal irradiation into horizontal direct beam irradiation and diffused horizontal irradiation, was verified according to the level of air pollution. So, we derive the most suitable decomposition model for use in domestic climatic conditions in Korea by comparing the ratio of direct and diffuse component on the horizontal which is calculated with Perez model and Watanabe model using the meteorological weather data observed for 14 months. Finally, to reduce the error of the transposition result, we verified the reliability of the decomposition which depends on the atmospheric environment.

서울지역 실측일사량을 이용한 일사량 직산분리 모델의 정밀성 검증 연구 (Performance Validation of Five Direct/Diffuse Decomposition Models Using Measured Direct Normal Insolation of Seoul)

  • 윤종호
    • 태양에너지
    • /
    • 제20권1호
    • /
    • pp.45-54
    • /
    • 2000
  • 본 논문에서는 건물 및 에너지 시스템 시뮬레이션에 적용되는 시간별 기상자료의 핵심항목인 일사량 관련자료의 신뢰성 검증을 위해, 서울지역 성분별 일사량의 장기간 측정치를 이용해 다양한 일사량 직산분리 모델의 정밀성 오차분석을 수행하였다. 1991년$\sim$1998사이 법선면직달일사량 및 수평면전일사량 시간별 측정치중 총 12,710시간의 유효데이타가 분석에 활용되었다. 직산분리 예측모델은 국내외에서 일반적으로 활용되고 있는 5개 모델을 분석하였다. 포트란 프로그램을 작성하여 5개 모델의 이론적 일사량 예측치를 계산하고, 6개의 오차 분석 지표를 이용해 측정치와 예측치의 정밀성이 분석되었다. 분석결과 대부분의 직산분리 모델이 실측치보다 작게 예측하고 있으며, CV(RMSE)가 34%$\sim$48%로 비교적 큰 오차폭을 보였다. 전반적으로 태양고도가 낮은 일출 및 일몰 시간대의 오차폭이 크며, 태양고도에 대한 영향이 회귀모델에 반영된 우전천(宇田川)의 직산분리 모델이 5개 모델중 가장 오차가 작은 것으로 평가되었다.

  • PDF

일사량 직산분리 모델에 따른 표준기상연도 데이터와 태양광 발전 예측량의 불확실성 (Variation of Solar Photovoltaic Power Estimation due to Solar Irradiance Decomposition Models)

  • 조을효;이현진
    • 한국태양에너지학회 논문집
    • /
    • 제39권3호
    • /
    • pp.81-89
    • /
    • 2019
  • Long-term solar irradiance data are required for reliable performance evaluation and feasibility analysis of solar photovoltaic systems. However, measurement data of the global horizontal irradiance (GHI) are only available for major cities in Korea. Neither the direct normal irradiance (DNI) nor the diffuse horizontal irradiance (DHI) are available, which are also needed to calculate the irradiance on the tilted surface of PV array. It is a simple approach to take advantage of the decomposition model that extracts DNI and DHI from GHI. In this study, we investigate variations of solar PV power estimation due to the choice of decomposition model. The GHI data from Korea Meteorological Administration (KMA) were used and different sets of typical meteorological year (TMY) data using some well-known decomposition models were generated. Then, power outputs with the different TMY data were calculated, and a variation of 3.7% was estimated due to the choice of decomposition model.

집광채광 설비 입사부의 성능 평가방법에 관한 연구 (Study on the method to evaluate performance of Light Collector in Light-collecting System)

  • 윤용상;문선혜
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.49.1-49.1
    • /
    • 2011
  • 집광채광 설비는 건축물의 조명에너지 절감 및 자연광의 실내 유입을 위해 적용 가능한 태양에너지설비로써 다른 신 재생 에너지 설비와 다르게 연간에너지생산에 대한 정량적 데이터가 아직까지 부재하다. 집광채광 설비의 설치효과를 판단하기 위해서는 집광채광 설비 설치에 따른 연간 에너지생산량 산출이 필요하며, 이를 위해서는 각 구성부분(집광부, 전송부 및 산광부)의 광전송 효율에 대한 데이터가 구축되어야 한다. 본 연구는 집광채광 설비의 효율 분석에 관한 첫 번째 단계로써 외부광속에 대한 집광부 통과 직후의 내부광속의 비율을 예측하였다. 국내에 보급된 집광채광 설비는 대부분 프리즘형과 광덕트형이며, 우선적으로 집광부 입사면의 경사각과 방위각이 다양하여 내부광속 산출방법론이 매우 복잡한 프리즘형을 분석대상으로 삼았다. 전일사량, 외부조도 및 집광부 내부조도가 측정되었으며, 외부광속으로부터 내부광속을 산출하는 공식을 유도하기 위해 천공상태에 따라 전일사량 측정치가 직산분리 되었다. Perez model과 Liu and Jordon에 의해 제시된 계산식과 입사면 및 집광부 면적을 고려하여 수평면 외부조도 측정치로부터 외부광속이 그리고 내부조도로부터 내부광속이 산출되었다. 입사면의 투과율이 동일하다는 전제 하에 천공상태에 따른 태양광 투과 비율을 도출한 결과, 담천공(Kt ${\leq}$ 0.3)에서 0.39, 부분담천공(0.3${\geq}$ 0.78)에서 1.0으로 나타났다. 도출된 투과비율을 외부광속에 적용하여 내부광속을 계산한 결과치와 측정치는 약 ${\pm}9%$ 정도의 차이를 보였다. 연간 기상데이터에 위와 같은 방법론이 적용되면 프리즘형 집광부의 연간 내부광속이 산출될 수 있다. 또한 기존 연구에서 제시된 발광효율 산출식과 일사 파장에 따른 시감도를 고려하면 매 시간별 외부조도도 산출이 가능하다. 일사량 측정치와 외부조도 측정치 사이의 상관관계를 분석한 결과 결정계수 $R^2$이 0.99인데 반해 일사량 측정치와 외부조도 계산치 사이의 상관관계 결정계수는 0.95로 측정치 보다 약간 작은 값을 갖는다. 이렇게 산출된 외부조도는 각 입사면의 면적을 반영하여 외부광속으로 변환되고, 앞서 산출된 천공상태별 투과비율이 적용됨으로써 내부광속이 도출될 수 있다. 이와 같은 집광부에 대한 연구를 바탕으로 향후 전송부와 산광부 효율을 도출하고 궁극적으로 집광채광 설비를 통해 실내에 전달되는 연간 빛에너지를 예측할 수 있을 것이다. 또한 본 연구의 방법론은 다른 형태의 집광채광 설비에도 적용이 가능할 것으로 판단되며, 국내 집광채광 설비의 연간 에너지생산량에 대한 폭 넓은 데이터 구축이 가능할 것으로 기대된다.

  • PDF