• 제목/요약/키워드: Diode Detector

검색결과 280건 처리시간 0.03초

X선 진단영역 에너지 측정을 위한 Photo-Diode 선량계(PD-2000)의 개발 (The development of photo-diode dosimeter(PD-2000) for the diagnostic X-ray Energy)

  • 김성철;이우철;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.27-32
    • /
    • 2000
  • It was produced radiation dosimeter used photo-diodes for which ionization by x-ray was applied and evaluated the value of utility in clinics as compared with ion-chamber. The result obtained were as follows : 1. Comparison of ion-chamber with photo-diode dosimeter's x-ray output by the change of x-ray tube voltage, and the ratio of ion-chamber to diode was $0.96{\sim}1.02$ which was not affected by x-ray beam quality. 2. The ratio of ion-chamber to diode was 0.96 by change of tube current and 0.97 by change of exposure time that is not affected by x-ray quantity. 3. The ratio of ion-chamber to diode was $0.97{\sim}1.04$ by thickness and $0.93{\sim}1.10$ by radiation field that is little affected by second ray quantity. 4. Reproducibility of photo-diode dosimeter was 0.011(CV) and it is a good result. 5. Photo-diode dosimeter was affected by the surface angle of detector over 30 degrees. Produced dosimeter was small, light, and meets good result compared with ionization chamber. It was expected come into wide use in clinic.

  • PDF

A measurement of wave length response on light emitting diode by a simplified wavemeter with a semiconductor color sensor

  • Muraoka, Tetsuya
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1956-1960
    • /
    • 1991
  • This paper describes the measured results upon monochromatic light, compound light, and light emanated from light emitting diodes by a simplified wavemeter with a semiconductor color sensor. Since a single unit element of a semiconductor color sensor with two PN junction photodiodes has been developed, the author has fabricated the simplified wave detector by using the element. The simplified wive detector has been measured results upon monochromatic light, compound light, and light emanated from light emitting diodes. Since luminescent color of each diode locates in luminosity region, comparison of measured values of PD-150 and PD-151 resulted no remarkable difference in averaged wave length. As for monochromatic light, PD-151 showed very cross value to the color filter peak value rather than PD-150. As for compound light, PD-150 has shown such influence of long wave length light which reaches to near infrared ray with respect to PD-151.

  • PDF

${\gamma}$-선 분광법을 이용한 한국산 방사성 원광내의 Uranium Thorium 함유량 측정 (Determination of % Contents of Uranium and Thorium in Natural Radioactive Ores by ${\gamma}$-ray Spectrometry)

  • 조성원;정문규;유건중;홍치유
    • Nuclear Engineering and Technology
    • /
    • 제2권4호
    • /
    • pp.273-278
    • /
    • 1970
  • 국내에서 채광한 자연방사능광물의 분석의뢰를 계기로 이에 관심을 갖고 Uranium와Thorium 의 함유량을 원광으로부터 비파괴적이고 간단한 ${\gamma}$-선 분광법으로 측정 분석하여 보았다. Ge(Li) 측정기를 ${\gamma}$-선 분광에 이용한 결과는 재래식방법에 비하여 분석정도를 훨씬 높일 수 있었으며, 자연방사능측정법과 원자로중성자로 조사시킨 activation법으로 Uranium와 Thorium의 함유량을 분석하였던바 하나의 시료(인천에서 채광)에서는 약 0.5%의 Uranium, 또 다른 시료에서는 2%의 Th와 0.1%의 U이 포함되어 있음이 확인되었다. 우리가 처음 시도한 이 분석법은 경제적이고 간편.신속하게 분석할수 있어 핵연료물질조사에 널러 이용할 수 있음을 입증한다.

  • PDF

2.4-GHz Power Amplifier with Power Detector Using Metamaterial-Based Transformer-Type On-Chip Directional Coupler

  • Dang, Trung-Sinh;Tran, Anh-Dung;Lee, Bomson;Yoon, Sang-Woong
    • ETRI Journal
    • /
    • 제35권3호
    • /
    • pp.554-557
    • /
    • 2013
  • This letter presents a power amplifier (PA) with an on-chip power detector for 2.4-GHz wireless local area network application. The power detector consists of a clamp circuit, a diode detector, and a coupled line directional coupler. A series inductor for an output matching network in the PA is combined with a through line of the coupler, which reduces the coupling level. Therefore, the coupler employs a metamaterial-based transformer configuration to increase coupling. The amount of coupling is increased by 2.5 dB in the 1:1 symmetric transformer structure and by 4.5 dB from two metamaterial units along the coupled line.

Peak Detector를 이용한 펄스방사선 선량 측정 (Pulse Radiation Dose Measurement using the Peak Detector)

  • 정상훈;이남호;오승찬
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.1020-1022
    • /
    • 2013
  • 본 논문에서는 펄스방사선 선량 측정을 위한 Peak Detector를 설계하였다. 펄스방사선은 수ns ~ 수십ns의 초고속의 신호로 Peak 값을 측정하기 어렵다. Peak Detector는 센서에서 발생한 Peak 전압을 수ms 동안 유지하므로 ADC를 이용하여 데이터를 쉽게 측정할 수 있다. Peak Detector 시뮬레이션 결과 Peak 값을 1ms 이상 유지하는 것을 확인하였으며 펄스방사선 조사시험 결과 $1.95{\times}10^6rad/s$의 선량을 확인하였다.

  • PDF

Correction of Dose Distribution at Total Body Irradiation using Compensator

  • 김종식;조현상;김영곤;조정근;주상규;박영환
    • 대한방사선치료학회지
    • /
    • 제9권1호
    • /
    • pp.87-93
    • /
    • 1997
  • The using of compensator is required to adjust the irregular dose distribution due to irregular thickness of the body in Total Body Irradiation. Aluminuim, copper or lead is generally used as compensator. In our study, we would like to introduce a result of the attenuation and compensation effect of radiation use compensator made by duralumin and its clinical use. The thickness of compensator was calculated by the attenustion of radiation, which was measured by polystyrene phantom and ionization chamber(farmer). The compensation effect of radiation was measured by diode detector. All of conditions were set as in real treatment, and the distanc from source to detector was 446 cm. We also made fixation of device to easily attach the compensator to LINAC. Beam spoiler was menufactured and placed on the patient to irradiate sufficient dose to the skin. diode detector were placed on head, neck, chest, umbilicus. pelvis and knee with each their entranced exit points, and datas of dose distribution were evaluated and compared in each points for eleven patients(Feb. 96-Feb. 97). The attenuation rate of irradiation by duralumin compensator was measured as $1.4\%$ in 2mm thickness. The mean attenuation rate was $1.3\%$ per 2mm as increasing the thickness gradually to 50 mm. By using duralunim compensator, dose distribution in each points of body was measured with ${\pm}2.8\%$ by diode detectior. We could easily calculate the thickness of compensator by measuring the attenuation rate of radiation, remarkably reduce the irragularity of dose distribution duo to the thickness of body and magnify the effect of radiation therapy.

  • PDF

출력 신호의 진폭 제어 회로를 가진 10 GHz LC 전압 제어 발진기 (10 GHz LC Voltage-controlled Oscillator with Amplitude Control Circuit for Output Signal)

  • 송창민;장영찬
    • 전기전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.975-981
    • /
    • 2020
  • 위상 잡음을 개선하기 위한 출력 신호의 진폭을 제어하는 회로를 가진 10 GHz LC 전압 제어 발진기(VCO : voltage-controlled oscillator)가 제안된다. 제안된 LC VCO를 위한 진폭 제어 회로는 피크 검출 회로, 증폭기, 그리고 전류원 회로로 구성된다. 피크 검출 회로는 2 개의 diode-connected NMOSFET과 하나의 커패시터로 구성되어 출력 신호의 최젓값을 감지함으로 수행된다. 제안하는 진폭 제어 회로를 가진 LC VCO는 1.2 V 공급 전압을 사용하는 55 nm CMOS 공정에서 설계된다. 설계된 LC VCO의 면적은 0.0785 ㎟이다. 제안된 LC VCO에 사용된 진폭 제어 회로는 기존 LC VCO의 출력 신호에서 발생되는 242 mV의 진폭 변화를 47 mV로 줄인다. 또한, 출력 신호의 peak-to-peak 시간 지터를 8.71 ps에서 931 fs로 개선한다.

HPLC/DAD/ESI-MS 및 고체상 추출법을 이용한 뇨시료중 갑상선 호르몬 분석 (Determination of thyroid hormones by solid-phase extraction using high performance liquid chromatograph/diode array detector/electro-spray ionization mass spectrometry in urine samples)

  • 곽선영;문명희;표희수
    • 분석과학
    • /
    • 제19권6호
    • /
    • pp.519-528
    • /
    • 2006
  • 본 연구에서는 뇨시료를 고체상 추출법으로 추출한 후 HPLC/DAD/ESI-MS(high-performance liquid chromatograph/diode array detector/electro-spray ionitation mass spectrometry)를 사용하여 분석하였다. 7종의 thyroid hormones의 HPLC 분리조건은 Hypersil ODS(octadecylsilica) 컬럼(4.6mm I.D., 100 mm length, particle size $5{\mu}m$)을 사용하고 ammonium formate buffer와 acetonitrile을 이동상으로 하여 기울기 용리한 결과 완전 분리가 가능하였으며, UV spectra 및 질량스펙트럼을 확인할 수 있었다. 고체상 추출법에 의한 전처리 최적 조건을 조사한 결과 시료를 pH 3으로 한 후 C18 고체상을 사용하여 4 mL의 methanol/ammonium hydroxide(9:1) 혼합용액으로 용리할 경우 회수율이 89.0-113.1%로 나타났다. HPLC/DAD를 이용하여 10-1000 ng/mL범위에서 검량선을 작성한 결과 $r^2$값은 0.992-0.998 으로 나타났으며 검출한계는 2-4 ng/mL(3.8-13.0 pmol/mL)로 계산되었다.

반도체레이저 단면여기 고체레이저에서의 최적 공진조건에 관한 해석 (Analysis of the oscillation condition optimized at laser-diode end-pumped solid-state laser)

  • 김병태;김태석
    • 한국광학회지
    • /
    • 제8권4호
    • /
    • pp.303-307
    • /
    • 1997
  • 반도체레이저로 여기되는 Nd:S-VAP 레이저에서 에너지 변환상태를 PZT를 검출기로 이용한 광음향 분광법으로 측정하였다. 광음향 분광법이 레이저 공진기 내부에서의 에너지 변환과정을 이해하고 공진기에서 출력거울의 최적화를 비교적 간단하게 실현시킬 수 있는 효과적인 측정방법임을 제시하였다.

  • PDF

선량보강(Build-up) 영역에서의 광자선 깊이선량률 측정을 위한 검출기의 특성 비교 (Characteristics of Detectors for Measurements of Photon Depth Doses in Build-Up Region)

  • 강세권;박석원;오도훈;박희철;김수산;배훈식;조병철
    • 한국의학물리학회지:의학물리
    • /
    • 제16권2호
    • /
    • pp.77-81
    • /
    • 2005
  • 표면 선량을 포함한 선량보강(build-up) 영역에 대한 깊이선량률(percentage depth dose)을 측정하는 데 있어서 적절한 측정방법을 결정하기 위해 6 MV 광자선에 대해 Atiix와 Markus 평행평판형 이온함, 원통형이온함, 그리고 다이오드 검출기를 사용하여 측정, 비교하었다. Attix 이온함에 의한 측정을 기준으로 할 때, Markus 이온함의 측정은 민조사면(open field)에서 $2\%$ 내로 일치하였으나, 오염전자가 포함된 광자선의 경우에는 최대 $3.9\%$의 차이를 보였다. 원통형 이온함과 다이오드 선량계의 경우에는 이들 검출기가 물 팬텀에 완전히 잠긴 이후부터는 오염전자가 포함된 광자선에 대해서도 각각 $1.5\%$ 혹은 $1.0\%$ 내의 정확도를 보였다. 따라서 민조사면에서 표면선량을 포함한 깊이선량률을 정확히 측정하기 위해서는 평행평판형 이온함이 추천되나, 표면에서의 정확한 선량에 특별한 관심을 두는 경우가 아니면, 원통형 이온함이나 다이오드 선량계를 이용하여 선량보강영역의 깊이선량률을 측정하는 것은 양호한 결과를 준다고 할 수 있다.

  • PDF