• Title/Summary/Keyword: Diode Detector

Search Result 280, Processing Time 0.023 seconds

Development of Parallel Arc Fault Detector Using Ripple Voltage (리플전압을 이용한 병렬아크 사고 감지기 개발)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.453-456
    • /
    • 2016
  • The major causes of electrical fire in low-voltage distribution lines are classified into short-circuit fault, overload fault, electric leakage, and electric contact failure. The special principal factor of the fire is electric arc or spark accompanied with such electric faults. This paper studies the development of an electric fire prevention system with detection and alarm of that in case of parallel arc fault occurrence in low-voltage distribution lines. The proposed system is designed on algorithm sensing the instantaneous voltage drop of line voltage at arc fault occurrence. The proposed detector has characteristics of high-speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. A new sensing control method that shows the detection of parallel arc fault is sensed to ripple voltage drop through a diode bridge full-wave rectifier at electrical accident occurrence. Some experimental tests of the proposed system also confirm the practicality and validity of the analytical results.

A Design of a VCO for an Advance Warning System of the Vehicle′s Speed Limitation (차량 속도 제한 사전 경보기용 전압 제어 발진기 설꼐)

  • 김동현;최익권
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.11
    • /
    • pp.1075-1081
    • /
    • 2004
  • In this paper, a VCO of a general advance warning system for vehicle's speed limitation in the X-band used in Japan is designed using a small signal scattering coefficient of PHEMT. A varactor diode that wide tuning range and series resistance 0 H is used for designing the VCO and -85 dBc/Hz of phase noise at 10 kHz of offset frequency is obtained by adjusting the reflection coefficient between the micro-strip line and the varactor device which determines transistor's operation voltage and resonant frequency, In addition +4.5 dBm of basic frequency signal output level and -25.6 dEc of the second harmonic constraint are acquired. Sample that produce in this paper could confirm that more excellent special quality appears than existing products in sensitivity.

Chiral Separation of ($\pm$)-Higenamine by Capillary Electophoresis

  • Choi, One-Kyun;Jung, Kyo-Soon;Choi, Heisook-Yun;Yang, Deok-Chun
    • Plant Resources
    • /
    • v.6 no.1
    • /
    • pp.81-88
    • /
    • 2003
  • Higenamine [1-(4-hydroxy-6, 7-dihydroxy-l, 2, 3, 4-tetrahydroisoquinoline) is a cardiotonic constituent of Aconiti tuber, one of the most widely prescribed oriental medicines. S-(-)higenamine was reported to have a stronger cardiotonic activity than R-(+)-higenamine and known as a central intermediate in the biosynthesis of various benzyl isoquionoline alkaloids in plants. The separation of higenamine enantiomers has been accomplished with capillary electrophoresis using cyclodextrins (CDs) as chiral selectors. Good resolution of this enantiomers was obtained using a 50 mM sodium phosphate buffer containing hydroxypropyl $\beta$-CDs using 27 cm fused silica capillary (50${\mu}{\textrm}{m}$ i.d., 20 cm to detector) at 25 $^{\circ}C$. With the electric field of 340 V/cm, the separation time of higenamine enantiomers was less than 6 min. Under this optimum conditions, the relative standard deviations of migration time and peak area were less than 1.6% and 3.2%. A 512-channel diode array detector was confirmed for the higenamine. The detection limits (S/N = 3) of these enantiomers are $1.5mutextrm{m}$/mL. We confirmed the chiral form of higenamine in medicinal plants.

  • PDF

CHARACTERISTICS OF FABRICATED SiC RADIATION DETECTORS FOR FAST NEUTRON DETECTION

  • Lee, Cheol-Ho;Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Park, Hyeon-Seo;Kim, Gi-Dong;Park, June-Sic;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.70-74
    • /
    • 2012
  • Silicon carbide (SiC) is a promising material for neutron detection at harsh environments because of its capability to withstand strong radiation fields and high temperatures. Two PIN-type SiC semiconductor neutron detectors, which can be used for nuclear power plant (NPP) applications, such as in-core reactor neutron flux monitoring and measurement, were designed and fabricated. As a preliminary test, MCNPX simulations were performed to estimate reaction probabilities with respect to neutron energies. In the experiment, I-V curves were measured to confirm the diode characteristic of the detectors, and pulse height spectra were measured for neutron responses by using a $^{252}Cf$ neutron source at KRISS (Korea Research Institute of Standards and Science), and a Tandem accelerator at KIGAM (Korea Institute of Geoscience and Mineral Resources). The neutron counts of the detector were linearly increased as the incident neutron flux got larger.

Design and Implementation of a Phase Locked Dielectric Resonator Oscillator for Ka Band LNB with Triple VCOs (3중구조 VCO를 이용한 Ka Band LNB 용 PLDRO 설계 및 제작)

  • Kang, Dong-Jin;Kim, Dong-Ok
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.441-446
    • /
    • 2008
  • In this papers, a PLDRO(Phase Locked Dielectric Resonator Oscillator) is designed and implemented at the oscillator in which fundamental frequency is 18.3 GHz. The proposed PLDRO so as to improve the PLDRO of the general structure is designed to the goal of the minimize of the size and the performance improvement. Three VCO(Voltage controlled Oscillator) and the power combiner improved the output power. A VCDRO(Voltage Controlled Dielectric Resonator Oscillator) is manufactured using a varactor diode to tune oscillating frequency electrically, and its phase is locked to reference frequency by SPD(Sampling Phase Detector). This product is fabricated on Teflon substrate with dielectric constant 2.2 and device is ATF -13786 of Ka-band using. This PLDRO generates an output power of 5.67 dBm at 18.3 GHz and has the characteristics of a phase noise of -80.10 dBc/Hz at 1 kHz offset frequency from carrier, the second harmonic suppression of -33 dBc. The proposed PLDRO can be used in Ka-band satellite applications

  • PDF

The Feasibility Study of photoconductor materials for the use of a dosimeter in Radiotherapy (광도전체 물질의 치료 방사선 선량계 적용을 위한 가능성 연구)

  • Jang, Giwon;Shin, Jungwook;Oh, Kyungmin;Park, Sungkwang;Kim, Jinyoung;Park, Jikoon;Nam, Sanghee
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.81-84
    • /
    • 2013
  • The use of the dosimetry have been increasingly recognized as high radiation energy and radiation treatment planning(RTP) have rapidly developed in radiotherapy. There are many types of detectors for the dosimetry such as ionization chamber, film, TLD, diode, and etc. Among such detectors, the diode detector uses a photoconductor materials that generate electrical signals by the incident radiation energy. Though many research groups are recently interested in such materials, there is few experimental results except for silicon in the radiation therapy field. In this study, the feasibility of photoconductor materials was verified as a dosimeter through the evaluation of response properties at a high radiation energy. For the fabricated detectors based on $HgI_2$ and $PbI_2$, reproducibility, linearity, and pulse-rate response were analyzed. Such evaluations are essential factors for the use of dosimeter. From results, linearity and reproducibility of the fabricated $HgI_2$ detector indicated about 7% error. The fabricated $PbI_2$ detector showed 1.7% error in linearity, and 12.2% error in reproducibility.

Evaluation of Detector Dependency on Collimator in SRS: Compared Detectors; CC01, CC13, SFD (뇌정위적 방사선수술 시 콜리메이터 크기 변화에 따른 검출기 의존성 평가)

  • Bae, Yong-Ki;Bang, Dong-Wan;Park, Byung-Moon;Kang, Min-Yeong;Kim, Yeon-Rye
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.109-113
    • /
    • 2008
  • Purpose: To evaluate the detector dependency in the various collimator size for Stereotactic Radiosugery (SRS). Materials and Methods: This study was performed with 6 MV photon beam (Varian 21EX, Varian, US) and the measurement detectors are used by ion chamber CC01, CC13 (Wellhofer, Germany) and stereotactic diode detector (SFD, Wellhofer, Germany). SRS collimator size was used by ${\varphi}$5, 10, 20, 30 mm (Brain Lab, Germany). Percentage depth dose (PDD) was measured at SSD 100 cm and field size 10×10 cm from individual detectors. Ouput factor was measured by using same setup of PDD and with maximum dose depth. Data was normalized at field size $10{\times}10\;cm$. Beam profile was measured at SSD 100 cm in SRS collimator ${\varphi}$10, 30 mm and field $10{\times}10\;cm$ and a comparison of FWHM (full width half maximum), penumbra width (20~80%). Results: The CC13 detector was overestimated 16% than other detectors from the PDD in the 5 mm collimator. Output factors were underestimated CC01 28%, CC13 72% in the 5 mm collimator and CC01 9.6%, CC13 25% in the 10 mm collimator than the SFD. Maximum difference was 3% at the FWHM of the dose profile in the 10 mm collimator and difference of the 30 mm collimator was 0% at the FWHM. Penumbra width was increased CC01 122%, CC13 194% in the 10 mm collimator and CC01 68%, CC13 185% in the 30 mm collimator than the SFD. Conclusion: It is very important for accurate dosimetry to select a detector in small field. The SFD was considered with the most accurate dosimeter for small collimator dosimetry in this study.

  • PDF

Dosimetric Characteristics of Edge $Detector^{TM}$ in Small Beam Dosimetry (소조사면 선량 계측을 위한 엣지검출기의 특성 분석)

  • Chang, Kyung-Hwan;Lee, Bo-Ram;Kim, You-Hyun;Choi, Kyoung-Sik;Lee, Jung-Seok;Park, Byung-Moon;Bae, Yong-Ki;Hong, Se-Mie;Lee, Jeong-Woo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.191-198
    • /
    • 2009
  • In this study, we evaluated an edge detector for small-beam dosimetry. We measured the dose linearity, dose rate dependence, output factor, beam profiles, and percentage depth dose using an edge detector (Model 1118 Edge) for 6-MV photon beams at different field sizes and depths. The obtained values were compared with those obtained using a standard volume ionization chamber (CC13) and photon diode detector (PFD). The dose linearity results for the three detectors showed good agreement within 1%. The edge detector had the best linearity of ${\pm}0.08%$. The edge detector and PFD showed little dose rate dependency throughout the range of 100~600 MU/min, while CC13 showed a significant discrepancy of approximately -5% at 100 MU/min. The output factors of the three detectors showed good agreement within 1% for the tested field sizes. However, the output factor of CC13 compared to the other two detectors had a maximum difference of 21% for small field sizes (${\sim}4{\times}4\;cm^2$). When analyzing the 20~80% penumbra, the penumbra measured using CC13 was approximately two times wider than that using the edge detector for all field sizes. The width measured using PFD was approximately 30% wider for all field sizes. Compared to the edge detector, the 10~90% penumbras measured using the CC13 and PFD were approximately 55% and 19% wider, respectively. The full width at half maximum (FWHM) of the edge detector was close to the real field size, while the other two detectors measured values that were 8~10% greater for all field sizes. Percentage depth doses measured by the three detectors corresponded to each other for small beams. Based on the results, we consider the edge detector as an appropriate small-beam detector, while CC13 and PFD can lead to some errors when used for small beam fields under $4{\times}4\;cm^2$.

  • PDF

In Vivo Dosimetry with MOSFET Detector during Radiotherapy (방사선 치료 중 MOSFET 검출기를 이용한 체표면 선량측정법)

  • Kim Won-Taek;Ki Yong-Gan;Kwon Soo-Il;Lim Sang-Wook;Huh Hyun-Do;Lee Suk;Kwon Byung-Hyun;Kim Dong-Won;Cho Sam-Ju
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2006
  • In Vivo dosimetry is a method to evaluate the radiotherapy; it is used to find the dosimetric and mechanical errors of radiotherapy unit. In this study, on-line In Vivo dosimetry was enabled by measuring the skin dose with MOSFET detectors attached to patient's skin during treatment. MOSFET dosimeters were found to be reproducible and independent on beam directions. MOSFET detectors were positioned on patient's skin underneath of the dose build-up material which was used to minimize dosimetric error. Delivered dose calculated by the plan verification function embedded in the radiotherapy treatment planning system (RTPs), was compared with measured data point by point. The dependency of MOSFET detector used in this study for energy and dose rate agrees with the specification provided by manufacturer within 2% error. Comparing the measured and the calculated point doses of each patient, discrepancy was within 5%. It was enabled to verify the IMRT by using MOSFET detector. However, skin dosimetry using conventional ion chamber and diode detector is limited to the simple radiotherapy.

  • PDF

Investigation of a Method for RF Circuits Analysis Based on Electromagnetic Topology

  • Park, Yoon-Mi;Chung, Young-Seek;Cheon, Chang-Yul;Jung, Hyun-Kyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.396-400
    • /
    • 2009
  • In this paper, electromagnetic topology (EMT) was used to analyze the electromagnetic compatibility (EMC) of RF circuits including passive and active components. It is difficult to obtain usable results for problems relating to electromagnetic coupling in complex systems when using conventional numerical or experimental methods. Thus it is necessary to find a new methodology for analyzing EMC problems in complicated electromagnetic environments. In order to consider the nonlinear characteristics of active components, a SPICE diode model was used. A power detector circuit and the receiver circuit of a radio control (RC) car were analyzed and experimented in order to verify the validity of this method.