• Title/Summary/Keyword: Diode

Search Result 4,469, Processing Time 0.045 seconds

Optimized Processing Condition of Production of Nannochloropsis oculata under Light-emitting Diode (LED) Condition (LED배양조건에서 미세조류 Nannochloropsis oculata의 생산 효율성을 높이는 공정 최적화)

  • Lee, Nam Kyu
    • Journal of Life Science
    • /
    • v.27 no.7
    • /
    • pp.754-759
    • /
    • 2017
  • The 100 l culture system was made on the basis of LED light, and Nannochloropsis oculata was cultured in f/2 medium at light intensity ($100{\mu}mol/m^2/s$), culture temperature ($20^{\circ}C{\pm}1^{\circ}C$) and LD cycle (12hr). As a result, the maximum biomass of 1.07 g/l was cultured as a result of 100 l mass culture at $100{\mu}mol/m^2/s$ and 24 mg/l nitrate concentration in LED blue (475 nm). The extraction was carried out using sonicator, homogenizer and chemical method 0.5M HCl shredding method. The contents of chlorophyll a, chlorophyll b and carotenoid were 1.6, 0.5 and 0.3 mg/g cell. When using homogenizer, it was measured at 1.0, 0.6 and 0.2 mg/g cell. The chemical breakdown method of 0.5M HCl, chlorophyll a, b, and carotenoid contents were measured as 0.9, 0.8, 0 mg/g cell. The highest amount of biomass during the distruption time was measured at 3.6 mg/g cell at 15 min disintegration and acetone, 3.6 mg/g cell of acetone, methanol, and ethanol were measured as effective solvents. Concentration was measured by using microfilter, disk type continuous centrifuge and tubular type continuous centrifuge were 16.0, 1.1 and 0.5 g/l, respectively. Four kinds of equipment such as hot air dryer, vacuum dryer, spray dryer and freeze dryer were tested to optimize the drying process. As a result, the recovery rates of spray dryer and freeze dryer were 80% and 60%.

A Study on the Peripheral Dose of 6MV X-ray Beam (6 MV X선의 주변선량분포)

  • Choi, Doo-Ho;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.24-33
    • /
    • 1989
  • The peripheral dose, defined as the dose outside therapeutic photon fields, was estimated for 6MV X-ray linear accelerator. The measurements were performed using silicon diode detectors controlled by automatic controlled water phantom. The effects of field size, collimator position, presence or absence of wedge filter, and wedge angle were analyzed. The results were as follows 1. The peripheral dose decreases as the distance from field margin increases and it is more than 2.4% of central axis maximum dose even at 15cm distance from field margin. 2. Maximum build-up of peripheral dose is at 2-3 mm from the water surface and drops to a minimum at 1.5cm depth and then the dose increase again. 3. The peripheral dose increases as the field size. increases. At the short distance from field margin, the difference of peripheral dose between 5 $\times\;5cm^2$ and 20 $\times\;20cm^2$ field size reaches more than 2 fold. 4. The peripheral dose is higher along the upper collimator than along the lower collimator. The differences is less than 1%. 5. The presence of wedge filter increases peripheral dose. And the peripheral dose is higher along the blade side of wedge filter than along the ridge side. The difference is about 3% at 5cm distance from the field margin for 15 $\times\;15cm^2$ field size and 60$^{\circ}$ wedge filter. 6. The Peripheral dose of wedge filter increases as the wedge filter angle increases and the increasing ratio is about 2 fold in 60$^{\circ}$wedge filter compared with open field.

  • PDF

Commissionning of Dynamic Wedge Field Using Conventional Dosimetric Tools (선량 중첩 방식을 이용한 동적 배기 조사면의 특성 연구)

  • Yi Byong Yong;Nha Sang Kyun;Choi Eun Kyung;Kim Jong Hoon;Chang Hyesook;Kim Mi Hwa
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 1997
  • Purpose : To collect beam data for dynamic wedge fields using conventional measurement tools without the multi-detector system, such as the linear diode detectors or ionization chambers. Materials and Methods : The accelerator CL 2100 C/D has two photon energies of 6MV and 15MV with dynamic wedge an91es of 15o, 30o, 45o and 60o. Wedge transmission factors, percentage depth doses(PDD's) and dose Profiles were measured. The measurements for wedge transmission factors are performed for field sizes ranging from $4\times4cm^2\;to\;20\times20cm^2$ in 1-2cm steps. Various rectangular field sizes are also measured for each photon energy of 6MV and 15MV, with the combination of each dynamic wedge angle of 15o 30o. 45o and 60o. These factors are compared to the calculated wedge factors using STT(Segmented Treatment Table) value. PDD's are measured with the film and the chamber in water Phantom for fixed square field. Converting parameters for film data to chamber data could be obtained from this procedure. The PDD's for dynamic wedged fields could be obtained from film dosimetry by using the converting parameters without using ionization chamber. Dose profiles are obtained from interpolation and STT weighted superposition of data through selected asymmetric static field measurement using ionization chamber. Results : The measured values of wedge transmission factors show good agreement to the calculated values The wedge factors of rectangular fields for constant V-field were equal to those of square fields The differences between open fields' PDDs and those from dynamic fields are insignificant. Dose profiles from superposition method showed acceptable range of accuracy(maximum 2% error) when we compare to those from film dosimetry. Conclusion : The results from this superposition method showed that commissionning of dynamic wedge could be done with conventional dosimetric tools such as Point detector system and film dosimetry winthin maximum 2% error range of accuracy.

  • PDF

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.

HVL Measurement of the Miniature X-Ray Tube Using Diode Detector (다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정)

  • Kim, Ju-Hye;An, So-Hyeon;Oh, Yoon-Jin;Ji, Yoon-Seo;Huh, Jang-Yong;Kang, Chang-Mu;Suh, Hyunsuk;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • The X ray has been widely used in both diagnosis and treatment. Recently, a miniature X ray tube has been developed for radiotherapy. The miniature X ray tube is directly inserted into the body irradiated, so that X rays can be guided to a target at various incident angles according to collimator geometry and, thus, minimize patient dose. If such features of the miniature X ray tube can be applied to development of X ray imaging as well as radiation treatment, it is expected to open a new chapter in the field of diagnostic X ray. However, the miniature X ray tube requires an added filter and a collimator for diagnostic purpose because it was designed for radiotherapy. Therefore, a collimator and an added filter were manufactured for the miniature X ray tube, and mounted on. In this study, we evaluated beam characteristics of the miniature X ray tube for diagnostic X ray system and accuracy of measuring the HVL. We used the Si PIN Photodiode type Piranha detector (Piranha, RTI, Sweden) and estimated the HVL of the miniature X ray tube with added filter and without added filter. Through an another measurement using Al filter, we evaluated the accuracy of the HVL obtained from a direct measurement using the automatic HVL calculation function provided by the Piranha detector. As a result, the HVL of the miniature X ray tube was increased around 1.9 times with the added filter mounted on. So we demonstrated that the HVL was suitable for diagnostic X ray system. In the case that the added filter was not mounted on, the HVL obtained from use of the automatic HVL calculation function provided by Piranha detector was 50% higher than the HVL estimated using Al filter. Therefore, the HVL automatic measurement from the Piranha detector cannot be used for the HVL calculation. However, when the added filter was mounted on, the HVL automatic measurement value using the Piranha detector was approximately 15% lower than the estimated value using Al filter. It implies that the HVL automatic measurement can be used to estimate the HVL of the miniature X ray tube with the added filter mounted on without a more complicated measurement method using Al filter. It is expected that the automatic HVL measurement provided by the Piranha detector enables to make kV-X ray characterization easier.

Quality Characteristics of Pleurotus eryngii Cultivated with Different Wavelength of LED Lights (LED광의 파장을 달리하여 재배한 새송이버섯의 품질특성)

  • Kim, Do-Hee;Choi, Hye-Jin;Jo, Woo-Sik;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.19 no.3
    • /
    • pp.354-360
    • /
    • 2012
  • The effect of the wavelength of the light emitted by the light-emitting diode (LED) on the growth characteristics and physicochemical and sensory qualities of Pleurotus eryngii were investigated. Pleurotus eryngii were grown under different light sources: blue light (450 nm), red light (650 nm), green light (525 nm), UV-A (365 nm), and mixed light ($B^*R$, $B^*G$, $R^*G$, $B^*R^*G^*UV-A$). The quantity of LED light was set up at 50% (LED: 64.9-108.0 $pmolm-2{\cdot}s-1$;fluorescentlight:11.7lux). Fluorescent light was used as control. There were no significant differences in the flesh firmness. In the case of the Pleurotuseryngii cultivated under red, green, and mixed light ($R^*G$), the color of the pileus and the length of the stipe were similar to those of the control group. The sensory scores were not significantly different between the LED lights (red, green, and $R^*G$) and the control. Among the three LED light conditions, the sample cultivated under red light recorded the highest score. The samples under UV-A, blue, and mixed light ($B^*R$, $B^*G$, $B^*R^*G^*U$) had a dark pileus color and had a short stipe. These results showed that the wavelength of LED light affected the growth and quality characteristics of Pleurotus eryngii, and that using red LED light is preferable for the cultivation of Pleurotus eryngii with better quality.

A Comparative Study of Physiological Activity and Ingredient Analysis of Glycyrrhiza uralensis Fischer Stems and Leaves Cultivated with Different Wavelength of LED Lights (LED광원에 따른 감초 지상부의 생리활성 및 성분 평가)

  • Bang, Keuk Soo;Chang, Young Nam;Jin, Jong Sik;Park, Sang A;Lim, Jae Soo;Park, Jeong Sub;Kim, Jong Sung;Lee, Jeong Ho
    • Korean Journal of Plant Resources
    • /
    • v.28 no.1
    • /
    • pp.126-134
    • /
    • 2015
  • Glycyrrhiza uralensis Fischer is one of the most commonly used herbs. Recently, the stem and leave of the plant have been interested in physiological activities because the aerial parts have been thrown away. Finding out cultivation method of Glycyrrhiza uralensis Fischer to improve chemical ingredients and biological activities has been tried these days. In this study, different wavelengths of light emitting diode (LED) were used for a cultivation of Glycyrrhiza uralensis Fischer. Antioxidant activities and inhibitory effect on mutagenecity of samples were evaluated. The stem and leave cultivated under blue light (BL-0) showed the strongest antioxidant activities of $3.02{\pm}0.13{\mu}g/ml$ ($EC_{50}$) and $2.18{\pm}0.18{\mu}g/ml$ ($EC_{50}$) in DPPH and ABTS radical scavenging test, respectively. Total phenolic content of BL-0 was $2.93{\pm}0.11g/100g$, the highest value between cultivation conditions. However, antioxidant activities of the stem and leave cultivated under red light were the weakest between samples. All of the stem and leave used in this study showed inhibitory effect on mutagenecity of 1-nitropyrene. BL-0 showed stronger inhibitory effects on mutagenicity of Trp-P-1, Trp-P-2, and AFB1 than samples cultivated under other conditions. Only on mutagenecity of 2-aminoanthracene, the stem and leave cultivated at 1 m apart from red light (RL-1) showed the strongest inhibitory effect. These results indicate that blue LED might be the most effective condition for improvement of physiological activities for the aerial parts of Glycyrrhiza uralensis Fischer in cultivation. The components were identified with GC/MS. Cytidine was detected only in RL-1 at 25 min of retention time and 2-bromotrimethylene glycol was detected only in BL-0 at 37 min.

Validation of a Method and Evaluation of Antioxidant Activity for the Simultaneous Determination of Riboflavin and Coixol in Coix lacryma-jobi var. ma-yuen Stapf Sprouts (율무 새싹 추출물의 Riboflavin과 Coixol의 동시 분석법 검증 및 항산화 활성)

  • Lee, Ji Yeon;Park, Jung Yong;Park, Chun-Geon;Kim, Dong Hwi;Ji, Yun-Jeong;Choi, Su Ji;Oh, MyeongWon;Hwang, Hosop;Lee, Yunji;Jeong, Jintae;Lee, Jeong Hoon;Seo, Kyung Hye
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.64 no.4
    • /
    • pp.452-458
    • /
    • 2019
  • Coix lacryma-jobi var. ma-yuen (Rom. Caill.) Stapf (CL), which contains riboflavin and coixol, has traditionally been used to treat cancer and arthritis. However, no method for the simultaneous determination of riboflavin and coixol in CL sprouts has been established. In this study, we established and validated a high-performance liquid chromatography-diode array detection (HPLC-DAD) method for the identification and quantification of two reference markers, riboflavin and coixol, in CL sprout extracts. CL sprouts (whole sprouts and leaves) were subjected to extraction with 70% ethanol at room temperature and at 80 ℃ under reflux conditions. The two extractions were validated with respect to specificity, accuracy, precision, and linearity. The content of the two reference markers was highest in leaves extracted under reflux conditions (riboflavin, 8.23 ± 0.32 mg/g; coixol, 5.95 ± 0.04 mg/g). We also investigated the antioxidant activity of the extracts via 2,2-diphenyl-1-picrylhydrazyl (DPPH) and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS+) scavenging assays. The results indicated that extracts obtained from sprouts under reflux conditions had the strongest antioxidative effects (DPPH half maximal inhibitory concentration [IC50], 68.9 ± 4.1 g/mL; and ABTS, IC50, 34.9 ± 0.1 g/mL). These results can serve as baseline data for the simultaneous determination of the two reference marker compounds, riboflavin and coixol, and development of functional food materials using CL sprouts.

Effect of Supplementary Radiation on Growth of Greenhouse-Grown Kales (온실재배 케일의 생장에 미치는 보광효과)

  • Heo, Jeong-Wook;Kim, Hyeon-Hwan;Lee, Kwang-Jae;Yoon, Jung-Boem;Lee, Joung-Kwan;Huh, Yoon-Sun;Lee, Ki-Yeol
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.1
    • /
    • pp.38-45
    • /
    • 2015
  • BACKGROUND: For commercial production of greenhouse crops under shorter day length condition, supplementary radiation has been usually achieved by the artificial light source with higher electric consumption such as high-pressure sodium, metal halide, or incandescent lamps. Light-Emitting Diodes (LEDs) with several characteristics, however, have been considered as a novel light source for plant production. Effects of supplementary lighting provided by the artificial light sources on growth of Kale seedlings during shorter day length were discussed in this experiment. METHODS AND RESULTS: Kale seedlings were grown under greenhouse under the three wave lamps (3 W), sodium lamps (Na), and red LEDs (peak at 630 nm) during six months, and leaf growth was observed at intervals of about 30 days after light exposure for 6 hours per day at sunrise and sunset. Photosynthetic photon flux (PPF) of supplementary red LEDs on the plant canopy was maintained at 0.1 (RL), 0.6 (RM), and $1.2(RH){\mu}mol/m^2/s$ PPF. PPF in 3 W and Na treatments was measured at $12{\mu}mol/m^2/s$. Natural light (NL) was considered as a control. Leaf fresh weight of the seedlings was more than 100% increased under the 3 W, Na and RH treatment compared to natural light considering as a conventional condition. Sugar synthesis in Kale leaves was significantly promoted by the RM or RH treatment. Leaf yield per $3.3m^2$ exposed by red LEDs of $1.2{\mu}mol/m^2/s$ PPF was 9% and 16% greater than in 3W or Na with a higher PPF, respectively. CONCLUSION: Growth of the leafy Kale seedlings were significantly affected by the supplementary radiation provided by three wave lamp, sodium lamp, and red LEDs with different light intensities during the shorter day length under greenhouse conditions. From this study, it was suggested that the leaf growth and secondary metabolism of Kale seedlings can be controlled by supplementary radiation using red LEDs of $1.2{\mu}mol/m^2/s$ PPF as well as three wave or sodium lamps in the experiment.

Effect of infection control barrier thickness on light curing units (감염 조절용 차단막의 두께가 광중합기의 중합광에 미치는 영향)

  • Chang, Hoon-Sang;Lee, Seok-Ryun;Hong, Sung-Ok;Ryu, Hyun-Wook;Song, Chang-Kyu;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.368-373
    • /
    • 2010
  • Objectives: This study investigated the effect of infection control barrier thickness on power density, wavelength, and light diffusion of light curing units. Materials and Methods: Infection control barrier (Cleanwrap) in one-fold, two-fold, four-fold, and eightfold, and a halogen light curing unit (Optilux 360) and a light emitting diode (LED) light curing unit (Elipar FreeLight 2) were used in this study. Power density of light curing units with infection control barriers covering the fiberoptic bundle was measured with a hand held dental radiometer (Cure Rite). Wavelength of light curing units fixed on a custom made optical breadboard was measured with a portable spectroradiometer (CS-1000). Light diffusion of light curing units was photographed with DSLR (Nikon D70s) as above. Results: Power density decreased significantly as the layer thickness of the infection control barrier increased, except the one-fold and two-fold in halogen light curing unit. Especially, when the barrier was four-fold and more in the halogen light curing unit, the decrease of power density was more prominent. The wavelength of light curing units was not affected by the barriers and almost no change was detected in the peak wavelength. Light diffusion of LED light curing unit was not affected by barriers, however, halogen light curing unit showed decrease in light diffusion angle when the barrier was four-fold and statistically different decrease when the barrier was eight-fold (p < 0.05). Conclusions: It could be assumed that the infection control barriers should be used as two-fold rather than one-fold to prevent tearing of the barriers and subsequent cross contamination between the patients.