• Title/Summary/Keyword: Dimple-type plate heat exchanger

Search Result 6, Processing Time 0.023 seconds

An Experimental Study on the Performance of Plastic Plate Heat Exchanger (플라스틱 판형 열교환기의 성능에 관한 실험적 연구)

  • Yoo Seong Yeon;Chung Min Ho;Kim Ki Hyung;Lee Je Myo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.117-124
    • /
    • 2005
  • Aluminum plate heat exchanger, rotary wheel heat exchanger, and heat pipe heat exchanger have been used (or ventilation heat recovery in the air-conditioning system. The purpose of this research is to develop high efficiency plastic plate heat exchanger which can substitute aluminum plate heat exchanger. Because thermal conductivity of plastic is quite small compared to that of aluminum, various heat transfer enhancement techniques are applied in the design of plastic plates. Five types of heat exchanger model are designed and manufactured, which are plate type, plate-fin type, turbulent promoter type, corrugate type, and dimple type. Thermal performance and pressure loss of each heat exchangers are measured in various operating conditions, and compared each other. Test results show that heat transfer performance of corrugate type, turbulent promoter type, and dimple type are increases about $43\%$, $14\%$, and $33\%$ at the equivalent fan power compared to those of plate type, respectively. On the other hand, the heat transfer performance of plate-fin type decreases $9\%$ because fins can not play their own role.

A Numerical Simulation of Flow and Heat Transfer in a Dimple-type Plate Heat Exchanger (딤플형 판형 열교환기의 유동 및 전열특성에 대한 수치해석)

  • Ahn, Hyuk-Jin;Lee, Sang-Hyuk;Hur, Nahm-Keon;Park, Hyoung-Joon;Ryu, Hea-Seong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.3
    • /
    • pp.149-155
    • /
    • 2010
  • In the present study, the characteristics on the internal flow and heat transfer of the dimple-type plate heat exchanger were numerically investigated. For the numerical analysis, the conjugate heat transfer analysis between hot fluid-separating plate-cold fluid was performed using the periodic boundary condition at the center area of the plate and appropriate inlet and outlet conditions for the two streams. The numerical results were validated by the comparison with the experimental data. From these results, the correlations of the Colburn j-factor for the heat transfer and the Fanning f-factor for the flow friction were obtained. The present results could be applicable for the optimal design of dimple-type plate heat exchanger.

Theoretical Study on the Heat Transfer Performance in the Various Type Plate Heat Exchanger (다양한 형상의 판형 열교환기 열전달 성능에 관한 해석적 연구)

  • Oh, Jae-Kyeong;An, Sung-Kook;Nam, Snag-Chul;Cho, Hong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.636-645
    • /
    • 2012
  • The performance of various type plate exchangers with different chevron angle, dimple size and arrangement was analysed by using Ansys v13.0. Heat transfer performance, pressure drop and flow patten of plate heat exchanger were investigated according to mass flow ratio investigated and compared. As a result, the $60^{\circ}$-chevron type plate heat exchanger showed the highest heat transfer performance but pressure drop was relatively high. The efficiency of $45^{\circ}$-chevron type plate heat exchanger showed the best performance in considering of heat transfer performance and pressure drop simultaneously. Among dimple type plate heat exchangers, the highest heat transfer performance was shown in a dim_zigzag type plate heat exchanger but pressure drop was very high. Besides, the dim_upsize plate heat exchanger showed very low pressure drop.

A Numerical Study on the Flow and Heat Transfer Characteristics of Plastic Plate Heat Exchanger (플라스틱 판형 열교환기의 유동 및 열전달 특성에 관한 수치해석적 연구)

  • Chung, Min-Ho;Yoo, Seong-Yeon;Han, Kyu-Hyun;Yoon, Hong-Ik
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1366-1371
    • /
    • 2008
  • Four simulation models of plastic plate heat exchangers are designed and simulated. The flat plate type heat exchanger is designed as the reference model in order to evaluate how much thermal performance increases. The turbulence promoter type heat exchanger is fabricated with cylindrical-type vortex generators and rib-type turbulence promoters. The corrugate type is obtained from the conventional stainless steel compact heat exchangers, which are called the herringbone-type compact heat exchangers. The dimple type heat exchanger has a number of dimples on its surface. In this study, the flow and heat transfer characteristics of the plastic plate heat exchanger are investigated using numerical simulation and compared with experimental results. The flows are assumed as a three-dimensional, incompressible and turbulent model. The standard k-$\varepsilon$ model is used as the turbulent flow modeling, the SIMPLE algorithm is used to treat the coupling between pressure and velocity, and first order upwind scheme is used for discretization of momentum, turbulent and energy. The computational analysis and experimental results both show that the friction coefficient and Nu number is highest in the corrugate type.

  • PDF

A Numerical Study on Performance of Air-to-Air Plastic Plate Heat Exchanger

  • Chung, Min-Ho;Yoo, Seong-Yeon;Han, Kyu-Hyun;Yoon, Hong-Ik;Kang, Hyoung-Chul
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.2
    • /
    • pp.52-60
    • /
    • 2009
  • The purpose of this research is to develop high efficiency plastic plate heat exchangers which can be substituted for conventional aluminum plate heat exchangers. Four simulation models of plastic plate heat exchangers are designed and simulated: that is, flat plate type, turbulent promoter type, corrugate type and dimple type heat exchanger. The flat plate type is designed as the reference model in order to evaluate how much thermal performance increases. The turbulent promoter type is fabricated with cylindrical-type vortex generators and rib-type turbulent promoters. The corrugate type is obtained from the conventional stainless steel compact heat exchangers, which are called the herringbone-type compact heat exchangers. The dimple type has a number of dimples on its surface. In this study, the flow and heat transfer characteristics of the plastic plate heat exchanger are investigated using numerical simulation and compared with experimental results. Numerical simulation is carried out using the FLUENT code. The flows are assumed as a three-dimensional, incompressible and turbulent model. The computational analysis and experimental results both show that the friction coefficient and Nu number is highest in the corrugate type. The tendency of numerical simulation results is in good agreement with that of the experimental results.

A Study on the Performance of Cooling/Reheating System Using Polymer Heat Exchanger (폴리머 열교환기를 사용한 냉각/재가열 시스템의 성능에 관한 연구)

  • Kim, Jin-Hyuck;Yoo, Seong-Yeon;Han, Kyu-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2154-2159
    • /
    • 2008
  • In conventional air-conditioning systems, when the circulated air from the air-conditioned space pass through the cooling coil in the air-conditioning system, the air is over-cooled to eliminate the moisture as well as to decrease the temperature. The purpose of this study is to test and evaluate performance of the cooling/reheating system which can save both cooling energy and reheating energy by exchanging heat between the cooled air and reheated air. Experimental apparatus consists of fan, ducts, polymer exchangers, cooling coil, electronic auxiliary heater and data acquisition system. Two types of polymer exchanger, plate type and dimple type, made of polypropylene for cooling/reheating system are designed. Heat transfer and dehumidification characteristics of system are tested. The results show that the energy saving is up to 40% in the range of present experimented conditions, and it decreases with increasing velocity, inlet temperature and specific humidity.

  • PDF