• 제목/요약/키워드: Dimple-Protrusion

검색결과 6건 처리시간 0.024초

주름진 덕트에서 딤플/돌출 형상이 열전달계수에 미치는 영향 (Effects of dimple/protrusion array on heat transfer coefficients in rectangular wavy duct)

  • 권현구;황상동;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2352-2356
    • /
    • 2008
  • Heat transfer and performance characteristics have been investigated for a rectangular wavy duct with dimple or protrusion arrays. The test duct was 15mm in height and 105mm wide. The print diameter of the dimple/protrusion wall was 12.99mm and the depth/height of the dimple/protrusion was 3.75mm. Local heat transfer coefficients on the dimple/protrusion wall were measured using a transient TLC technique. The Reynolds number was varied from 3,000 to 10,000. For the wavy duct tested in this study, adverse static pressure characteristics occurred at turning region of the wavy duct due to secondary flows. For the wavy duct with protrusion array, higher heat transfer enhancement level of 7.4 times than smooth straight case in maximum was obtained at low Reynolds number due to the high heat transfer enhancement by vortex flows. Also, the protrusion array increased the performance level of 3.0 at low Reynolds number of 3,000.

  • PDF

딤플과 돌출이 설치된 수평채널의 열전달 및 압력강하 특성에 관한 수치해석적 연구 (Numerical Study on Heat Transfer and Pressure Drop Characteristics in a Horizontal Channel with Dimple and Protrusion Arrays)

  • 김지훈;허주녕;신지영;손영석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.57-63
    • /
    • 2012
  • 열전달 향상을 위하여 이차유동을 발생시켜 열전달을 증가시키는 방법에는 여러 가지가 있다. 본 연구에서는 수평채널에 딤플과 돌출을 설치하여 각각의 깊이와 높이를 변화시켰을 때의 압력강하 및 열전달 특성을 수치해석을 통하여 연구하였다. 딤플과 돌출은 수평채널의 윗면과 아래면 에 설치되었으며, 깊이 및 높이를 0.125, 0.25, 0.25, 0.3, 0.375로 하였다. 딤플의 경우, 후면부에서 높은 Nusselt 수가 나타났고 깊이가 커질수록 평균 Nusselt 수가 감소하였다. 돌출의 경우, 전면부에서 높은 Nusselt 수가 나타났고 높이가 커질수록 Nusselt 수가 증가하였다. 딤플과 돌출 모두 유속이 증가함에 따라 열전달이 향상되는 경향을 보였지만 성능계수는 감소하였다. 성능계수는 유속이 낮은 영역에서 가장 크게 나타났다.

돌출부를 포함한 딤플 표면을 가진 냉각 유로에서의 유동과 열전달 성능 향상에 관한 수치적 연구 (Numerical Study on Flow and Heat Transfer Enhancement in a Cooling Passage with Protrusion-In-Dimples)

  • 김정은;하만영;윤현식;두정훈
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.805-814
    • /
    • 2011
  • In the present study, the detailed flow structure and heat transfer characteristics in the newly-designed heat transfer surface geometry were investigated. The surface geometry proposed in the present study is a traditional dimple structure combining with a protrusion inside the dimple, which is named a protrusion-in-dimple in this study. The basic idea underlying the present surface geometry is to enhance the flow mixing and the corresponding heat transfer in the flow re-circulating region generated by a conventional dimple cavity. The present study was performed by the direct numerical simulation at a Reynolds number of 2800 based on mean velocity and channel height and Prandtl number of 0.71. Three different protrusion heights for protrusion-in-dimples were considered as the main design parameter of the present study. The calculated pressure drop and heat transfer capacity were assessed in terms of the Fanning friction factor and Colburn j factor. The overall performances estimated in terms of the volume and area goodness factor for protrusion-in-dimple cases were higher than the conventional dimple case.

고온고압수중에서 접촉형상에 따른 마멸거동 분석 (Analysis of Wear Behaviour Corresponding to Contact Shape in High Temperature and High Pressure Environment)

  • 송주선;김형규;이영호;김재훈
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.31-36
    • /
    • 2004
  • In this paper, fretting wear tests were conducted in air at room temperature (RT) and in water at high temperature and high pressure (HTHP) environment to analyze the wear characteristic. As for the supporting condition between the tube and spring/dimple, the gap of 0.2 mm in air at RT and the normal force of 10 N and the slip of $50\;{\mu}\;m$ in water at HTHP were applied. Four different shapes of spring/dimple specimen (type A, B, C, D) were used. Detail eaxamination of wear scar was also performed using SEM micrographs. As a result, in the case of the spring of truncated wedge, severer wear occurs than the others. Protrusion part was found and larger in air at RT. It is thought that the difference in the wear volume and the protrusion is caused by the different wear mechanism corresponding to the different environment.

  • PDF

이차구순열변형에서 상순반흔제거술 후 Abbe 피판을 이용한 재건: 사진계측학적 연구 (Correction of Secondary Cleft Lip Deformities by Scar Excision and Abbe Flap Coverage: Photogrammetric Analysis)

  • 한기환;곽민호;여현정;권혁준;김준형;손대구
    • Archives of Plastic Surgery
    • /
    • 제38권6호
    • /
    • pp.747-754
    • /
    • 2011
  • Purpose: The Abbe flap procedure has been used to correct disharmony of the upper and lower lips as well as for making a philtrum for patients with secondary cleft lip deformities. But the Abbe flap procedure adds two scars in addition to the prior operative scar on the upper lip. This study was conducted to determine the treatment outcomes of esthetic subunit excision of the scar on the philtrum and Abbe flap coverage for correction of cleft lip deformities with photogrammetric analysis. Methods: This study investigated a total of 11 patients with cleft lip deformities who underwent scar excision with Abbe flap coverage, and the patients were followed up for at least 6 months. Under general anesthesia, a mushroom-shaped Abbe flap was drawn on the lower lip with a width of 8 mm and a height 1~2 mm longer than that of the philtral midline. The epidermis and dermis of the scar on the upper lip were excised. In the cases with alar base depression, the orbicularis oris muscle was split vertically and transposed to the alar base. The Abbe flap was harvested as a pedicled flap containing a small amount of muscle and this was rotated 180-degree to be inserted into the upper lip. Mucosa, muscle, subcutaneous tissue and skin were closed in layers. The flap was divided at the 7~14 postoperative day. The postoperative outcomes were evaluated by using photogrammetric analysis. Three indices were measured from the standard clinical photographs taken before and after the surgery. For anthroposcopic assessment, observers described the postoperative outcomes using an ordinary scale method. Results: The postoperative values obtained in the photogrammetric analysis showed improvement as compared with the preoperative ones. Improved anthroposcopic outcomes were also noted. Conclusion: Scar excision and Abbe flap coverage were proven to be effective in improving protrusion and the height of the upper lip, the scar of the upper lip and the symmetry of Cupid's bow and the philtral column, as well as formation of the philtral dimple.