• 제목/요약/키워드: Dimensionless Correlation

Search Result 89, Processing Time 0.022 seconds

An Empirical Correlation for Subcooled Two-Phase Critical Flow Rates in Short Tubes, Nozzles, and Orifices

  • Park, Choon-Kyung;Seok Cho;Won, Soon-Yeun;Min, Kyung-Ho;Chung, Moon-Ki
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.273-278
    • /
    • 1997
  • Critical two-phase flow rates of subcooled water through very short tube (L=20 mm) with small diameters (D=1.0 mm) has been measured for wide ranges of subcooling(0~186$^{\circ}C$) and pressure (0.5~2.0 MPa). Experimental results show that subcooled critical two-phase flow rates can be expressed in terms of two scaling parameters for geometries and initial conditions. They are discharge coefficient of cold water, ( $C_{d}$ )$_{ref}$, and dimensionless subcooling, $\Delta$ $T^{*}$$_{sub}$, respectively. A new empirical correlation expressed in terms of ( $C_{d}$ )$_{ref}$ and $\Delta$ $T^{*}$$_{sub}$ is obtained for subcooled two-phase flow rates through very short length tube. Comparisons between the mass fluxes calculated by Present correlation and a number of experimental data show that the agreement is very good.ood.ood.ood.

  • PDF

Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser

  • Kang, Seong-Kwon;Chu, In-Cheol;No, Hee-Cheon;Chun, Moon-Hyun;Sung, Chang-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.548-560
    • /
    • 1999
  • An experimental investigation has been peformed to examine the effects of various geometrical parameters and an initial operating condition on the air-water countercurrent How limitation (CCFL) in a simulated PWR hot leg. A total of 118 experimental data for the onset of CCFL and zero liquid penetration were obtained for various combinations of test parameters. It was observe that the CCFL can be classified into three different categories: (the onset of CCFL, (the partial liquid delivery, and (r) the zero liquid penetration. The observed mechanisms of the onset of CCFL were different depending on the inlet water flow rate. The parametric effects of pipe diameter, horizontal pipe length, horizontal pipe length-to-diameter (L/D) ratio, and initial water level in the horizontal pipe of the test section on the onset of air-water CCFL were also examined. An empirical correlation for the onset of CCFL in a horizontal pipe connected to an inclined riser was developed in terms of Wallis flooding parameters for the low inlet water flow rate region. Comparisons of the present empirical correlation with the air-water CCFL data of large pipe diameters show that the present correlation agrees more closely with the experimental data than the existing CCFL correlations.

  • PDF

Conjugate Natural Convection in Double Enclosed Annuli Between Horizontal Concentric Cylinders (水平 同心圓二重 環狀密閉 空間에서의 Conjugate 自然對流 熱傳達)

  • 손병진;강희영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.4
    • /
    • pp.430-439
    • /
    • 1985
  • Conjugate natural convection in double enclosed annuli between horizontal concentric cylinders has been studied by the numerical analysis and experimental measurements. The interface conditions between the liquid and the solid of middle shell are obtained through the correlation factor based on the ratio of solid to fluid thermal conductivities and the Prandtl number. The characteristics of conjugate heat transfer are discussed under various dimensionless parameters such as conductivity ratios, shell thickness, diameter ratios, Prandtl number, and Rayleigh number. It is found that the average equivalent conductivity K over var $_{eq}$ does not depend on the conductivity ratios and shell thickness. The K over bar $_{eq}$ however, depends on the Prandtl number and the Rayleigh number.

Performance of Short Tube Orifices Using R-410A Near the Critical Region (R-410A 임계영역 운전조건에서 오리피스의 성능특성에 관한 연구)

  • Choi, Jong-Min;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1106-1112
    • /
    • 2005
  • An experimental investigation was performed to develop an empirical correlation of R-410A flowing through short tube orifices working near the critical region. Tests were executed by varying upstream pressure from 2,619 kPa to 4,551 kPa, and upstream subcooling from 2.8 and $11.1^{\circ}C$. The experimental data were represented as a function of major operating parameters and short tube diameter. As compared to mass flow trends at normal upstream pressures, flow dependency on upstream subcooling became more significant at high upstream pressures due to a higher density change. Based on the database obtained from this study and literature, an empirical correlation was developed from a power law form of dimensionless parameters generated by the Buckingham Pi theorem. The correlation yielded good agreement with the data. Approximately $92\%$ of the data were correlated within a relative deviation of $5\%$.

Interfacial shear stresses and friction factors in nearly-horizontal countercurrent stratified two-phase flow (근사수평 반류성층 2상유동에서의 계면전단응력 및 마찰계수)

  • 이상천;이원석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.1
    • /
    • pp.116-122
    • /
    • 1988
  • Interfacial shear stresses have been determined for countercurrent stratified flow of air and water in a nearly-horizontal rectangular channel, based upon measurements of pressure drop, gas velocity profiles and mean film thickness. A dimensionless correlation for the interfacial friction factor has been developed as a function of the gas and liquid Reynolds numbers. Equivalent surface roughnesses for the interfacial friction factor have been calculated using the Nikuradse correlation and have been compared with the intensity of the wave height fluctuation on the interface. The results show that the interfacial shear stress is mainly affected by turbulent mixing near the interface due to the wave motion rather than by the roughened surface.

Evaluation on the Cooling Performance to Design Heat sinks for LED lightings (LED 조명용 히트싱크 방열기 설계를 위한 냉각성능 평가)

  • Jung, Tae-Sung;Kang, Hwan-Kook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.778-784
    • /
    • 2012
  • In comparison with some other light sources, LED has merits such as increased life expectancy, fast response, pollution free, and high energy efficiency. Lately, due to development of LED with high brightness and capacity, LED has widely used in many industrial fields such as automotive, aviation, display, transportation and special lighting applications. Since the high heat generation of LED chips can cause a reduction in lifetime, degradation of luminous efficiency, and variation of color temperature, studies have been carried out on the optimization of LED packaging and heat sinks. In this study, experiments on measuring the heat generation rate of LED and the cooling performance of a heat sink were carried for analyzing the thermal characteristics of LED lighting system in free convection. From the results, dimensionless correlation on the cooling performance of heat sink in natural convection was proposed with Nusselt number and Rayleigh number as a guideline for designing cooling device of LED lightings.

A Generalized Flow Model and Flow Charts for Predicting Mass Flow Rate through Short Tube Orifices (일반화된 오리피스의 유량예측 상관식 및 유량선도)

  • Choi Jong Min;Kim Yongchan;Kwak Jae Su;Kwon Byong Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.895-900
    • /
    • 2004
  • With the phaseout of CFC and HCFC refrigerants, refrigeration and heat pump systems must be redesigned to match and improve system performance with alternative refrigerants. A generalized flow model for predicting mass flow rate through short tube orifices is derived from a power law form of dimensionless parameters generated by Pi-theorem. The database for developing the correlation includes extensive experimental data for R12, R22, R134a, R407C, R410A, and R502 from the open literature. The correlation yields an average deviation of $0.3\%$ and a standard deviation of $6.1\%$ based on the present database. In addition, rating charts for predicting refrigerant flow rate through short tube orifices are generated for R12, R22, R134a, R407C, R410A, and R502.

The Reduced Model Test for the Determination of Ventilation Velocity to Prevent Backflow in Uni-directional Road Tunnel during a Fire Disaster (일방향 도로터널내 화재 발생시 역류를 막는 환기속도결정에 관한 축소모형실험)

  • 유영일;이희근
    • Tunnel and Underground Space
    • /
    • v.8 no.2
    • /
    • pp.107-117
    • /
    • 1998
  • In the case of a fire disaster in a uni-directional road tunnel, it is important to determine the critical ventilation velocity to prevent the backflow travelling toward the tunnel exit where vehicles are stopped. The critical ventilation velocity is horizontal velocity to prevent hot smoke from moving toward the tunnel exit. According to Froude modelling, the model tunnel whcih was 300mm in diameter and 21 m in length was made of acryl tubes. Inner section of acryl tubes was clothed with polycarbonate. 1/20 scaled model vehicles were installed to simulate the situation that vehicles are stopped in the tunnel exit. Methanol in a pool type burner was burned in the middle of tunnel to simulate a fire hazard. In this study, the basis of determining the critical ventilation velocity is the ventilation flow rate that is able to maintain the allowable CO concentration in the tunnel section. We assumed that the allowable CO concentration was backflow dispersion index. Futhermore, We intended to find out CO distribution and temperature distribution according as we changed ventilation velocity. The results of this study were that no backflow happened when ventilation velocity was 0.52 m/s in the case of 5.75 kW. If we adapt these results of a fire disaster releasing 10MW heat capacity in real tunnel which is 400m in length, no backflow happens when ventilation velocity is 2.31m/s. After we figured out dimensionless heat release rate and dimensionless ventilation velocity of model test and those of real test to verify experimental correctness, we tried to find out correlation between experimental results of model tunnel and those of real tunnel.

  • PDF

Multiple-Hole Effect on the Performance of a Sparger During Direct Contact Condensation of Steam

  • Seok Cho;Song, Chul-Hwa;Chung, Heung-June;Chun, Se-Young;Chung, Moon-Ki
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.482-491
    • /
    • 2001
  • An experimental study has been carried out to investigate an I-type sparger-performance in view of pressure oscillation and thermal mixing in a pool. Its pitch-to-hole diameter, P/D, varies from 2 to 5. The test conditions are restricted to the condensation oscillation regime. In the present study, two different hole patterns, staggered and parallel types, are employed under various test conditions. The amplitude of the pressure pulse shows a peak for pool temperatures of 45∼85$\^{C}$, which depends on P/D and the steam mass flux. The effect of hole pattern on the pressure load is smaller than that of P/D. The dominant frequency increases with the subcooling temperature of pool water and P/D. A correlation for the dominant frequency is proposed in terms of the pitch-to-hole diameter ratio and other dimensionless thermal hydraulic parameters.

  • PDF

Evaluation of Heat Transfer performance of Wire-coil Inserted Tube (와이어코일 삽입법을 이용한 열전달 촉진기술 성능평가)

  • 이주동;박종호;이상천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.457-465
    • /
    • 2000
  • An experiment was carried out to evaluate the thermal performance of the wire-coil inserts method. Tested were the smooth tubes with the wire-nil inserts of various pitch and helix angle combinations. Test fluids were the 50%-solution of the ethylene glycol and the Hue water. Heat transfer coefficient and friction factors were deduced from the measured values of temperatures, flowrates and pressure drops. A unified dimensionless correlation for the heat transfer coefficients was developed as a function of the pitch to diameter ratio, the Reynolds number and the Prandtl number. An exergy analysis was performed to evaluate an optimal operating condition with the wire-coil inserts.

  • PDF