• 제목/요약/키워드: Dimensional measurement accuracy

검색결과 352건 처리시간 0.024초

Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography

  • Sabban, Hanadi;Mahdian, Mina;Dhingra, Ajay;Lurie, Alan G.;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.73-80
    • /
    • 2015
  • Purpose: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. Materials and Methods: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. Results: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. Conclusion: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.

Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography

  • Silva, Nathalia Cristine da;Barriviera, Mauricio;Junqueira, Jose Luiz Cintra;Panzarella, Francine Kuhl;Raitz, Ricardo
    • Imaging Science in Dentistry
    • /
    • 제47권1호
    • /
    • pp.11-15
    • /
    • 2017
  • Purpose: This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT(Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. Materials and Methods: A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal(distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. Results: All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. Conclusion: It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators.

3차원 레이저 스캐너 및 BIM을 활용한 터널 과대.과소 굴착 평가 (Assessment of over / under-break of tunnel utilizing BIM and 3D laser scanner)

  • 박정준;신재철;황주환;이강현;서형준;이인모
    • 한국터널지하공간학회 논문집
    • /
    • 제14권4호
    • /
    • pp.437-451
    • /
    • 2012
  • 최근 3차원 레이저 스캐너는 토목 분야의 적용에 관한 다수의 연구가 수행되고 있으며, 연구 분야 역시 터널 및 교량, 토공량 산정, 시공검측, 암반절리 측정 등 여러 분야에서 이루어지고 있다. 그 중 터널 시공 시 여굴량 및 미굴량을 산정함에 있어 3차원 레이저 스캐너를 활용하는 연구가 점차적으로 이루어지고 있으며, 지금까지의 연구는 스캔 데이터와 2차원 CAD 도면과의 비교를 통해 여굴량 및 미굴량을 산정하는 방식으로 이루어 졌다. 그러나 터널이 비교적 단순한 형상의 구조물이라 하더라도 3차원 형상의 구조물로 정확한 여굴량 및 미굴량을 산정하기 위해서는 3차원적인 비교가 필요하다. 본 연구에서는 3차원 레이저 스캐너로 획득한 스캔 데이터와 3차원 설계 모델링인 BIM을 활용하여 시공시 발생하는 여굴량 및 미굴량을 산정하는 시공오차 평가 프로그램을 개발하였으며, 이를 위한 효율적인 스캔 데이터의 처리 프로세스를 제안하였다. 또한 실제 현장에 3차원 레이저 스캐너를 적용하여 시공오차를 산정하였으며, 프로그램의 성능을 검증하였다.

Usefulness of four commonly used neuropathic pain screening questionnaires in patients with chronic low back pain: a cross-sectional study

  • Gudala, Kapil;Ghai, Babita;Bansal, Dipika
    • The Korean Journal of Pain
    • /
    • 제30권1호
    • /
    • pp.51-58
    • /
    • 2017
  • Background: Recently symptoms-based screening questionnaires have gained attention for screening for a neuropathic pain component (NePC) in various chronic pain conditions. The present study assessed the usefulness of four commonly used NePC screening questionnaires including the Self-completed douleur neuropathique 4 (S-DN4), the ID Pain, the painDETECT questionnaire (PDQ), and the Self-completed Leeds Assessment of neuropathic Symptoms and Signs (S-LANSS) questionnaire in patients with chronic low back pain (CLBP) to assess the presence of NePC. Methods: This is a single-center cross-sectional study where patients with CLBP, with or without leg pain, were included. Participants were initially screened for NePC presence by a physician according to the regular practice, and later assessed using screening questionnaires. The diagnostic accuracy of these questionnaires was compared assuming the physician-made diagnosis as the gold standard. Results: A total of 215 patients with CLBP of which 164 (76.3%, 95% CI, 70.2-81.5) had a NePC were included. S-DN4, ID Pain, and PDQ have an area under the curve (AUC) > 0.8 indicating excellent discrimination. However, S-LANSS has an AUC of 0.69 (0.62-0.75), indicating low discrimination. S-DN4 has a significantly higher AUC as compared to ID Pain (d(AUC) = 0.063, P < 0.01) and S-LANSS (d(AUC) = 0.197, P < 0.01). But the AUC of S-DN4 does not significantly differ from that of PDQ (d(AUC) = 0.013, P = 0.62). Conclusions: S-DN4, ID Pain, and PDQ, but not S-LANSS, have good discriminant validity to screen for NePCs in patients with CLBP. Despite using all the tests, 20-30% of patients with an NePC were missed. Thus, these questionnaires can only be used as an initial clue in screening for NePCs, but do not replace clinical judgment.

일측성 구순열 환자에서 3차원 수치사진측량 스캔과 직접계측 방법의 비교 (Comparison of the 3D Digital Photogrammetry and Direct Anthropometry in Unilateral Cleft Lip Patients)

  • 석효현;권근용;백승학;최태현;김석화
    • 대한두개안면성형외과학회지
    • /
    • 제14권1호
    • /
    • pp.11-15
    • /
    • 2013
  • Background: In cleft lip patients, the necessity of a thorough preoperative analysis of facial deformities before reconstruction is unquestioned. The surgical plan of cleft lip patient is based on the information gained from our preoperative anthropometric evaluation. A variety of commercially available three-dimensional (3D) surface imaging systems are currently introduced to us in plastic surgery for these use. However, few studies have been published on the soft tissue morphology of unrepaired cleft infants described by these 3D surface imaging systems. Methods: The purpose of this study is to determine the accuracy of facial anthropometric measurements obtained through digital 3D photogrammetry and to compare with direct anthropometry for measurement in unilateral cleft lip patients. We compared our patients with three measurements of dimension made on both sides: heminasal width, labial height, and transverse lip length. Results: The preoperative measurements were not significantly different in both side of labial height and left side of heminasal width. Statistically significant differences were found on both side of transverse lip length and right side of heminasal width. Although the half of preoperative measurements were significantly different, trends of results showed average results were comparable. Conclusion: This is the first study in Korea to simultaneously compare digital 3D photogrammetry with traditional direct anthropometry in unilateral cleft lip patients. We desire this study could contribute the methodological choice of the many researchers for proper surgical planning in cleft lip reconstruction field.

스테레오 카메라와 측정에 의한 3D 대상체 포인트 클라우드의 불규칙 삼각 매싱 기반 체적 계산 (The Stereo Camera Measurement of Point Cloud on 3D Object and the Calculation of Volume Based on Irregular Triangular Mesh)

  • 이영대;조성윤;김경;이동규
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.153-159
    • /
    • 2012
  • 안전하고 쾌적한 도시 환경을 조성하기 위해 폐기물 매립 시설은 필요하며 폐기물 부피 관리의 신뢰성 및 용량 정보의 정확성을 파악하는 것이 필요하다. 이 논문에서는 쓰레기 매립의 표준화를 위한 일환으로 쓰레기 체적을 주기적으로 계산하는 알고리즘을 제시하였다. 스테레오 카메라 캘리브레이션 이후에 대상체의 표면에 대한 포인트 클라우드(point cloud)를 얻을 수 있었으며 이것을 물체의 체적 계산 알고리즘의 입력으로 선택하였다, 비균일 삼각 격자 기반 메싱(non-uniform triangular meshing) 방법에 기초한 두 개의 체적 계산 알고리즘을 제안하였으며 알고리즘의 타당성을 시뮬레이션과 실제 실험을 통해 입증하였다. 제시된 알고리즘은 쓰레기 매립의 체적 계산 뿐 만이 아니라 삼차원 객체의 일반적인 체적 계산을 위한 알고리즘으로도 사용될 수 있다.

Validity of a Portable APDM Inertial Sensor System for Stride Time and Stride Length during Treadmill Walking

  • Tack, Gye Rae;Choi, Jin Seung
    • 한국운동역학회지
    • /
    • 제27권1호
    • /
    • pp.53-58
    • /
    • 2017
  • Objective: The purpose of this study was to compare the accuracy of stride time and stride length provided by a commercial APDM inertial sensor system (APDM) with the results of three dimensional motion capture system (3D motion) during treadmill walking. Method: Five healthy men participated in this experiment. All subjects walked on the treadmill for 3 minutes at their preferred walking speed. The 3D motion and the APDM were simultaneously used for extracting gait variables such as stride time and stride length. Mean difference and root mean squared (RMS) difference were used to compare the measured gait variables from the two measurement devices. The regression equation derived from the range of motion of the lower limb was also applied to correct the error of stride length. Results: The stride time extracted from the APDM was almost the same as that from the 3D motion (the mean difference and RMS difference were less than 0.0001 sec and 0.0085 sec, respectively). For stride length, mean difference and RMS difference were less than 0.1141 m and 0.1254 m, respectively. However, after correction of the stride length error using the derived regression equation, the mean difference and the RMS difference decreased to 0.0134 m and 0.0556 m or less, respectively. Conclusion: In this study, we confirmed the possibility of using the temporal variables provided from the APDM during treadmill walking. By applying the regression equation derived only from the range of motion provided by the APDM, the error of the spatial variable could be reduced. Although further studies are needed with additional subjects and various walking speeds, these results may provide the basic data necessary for using APDM in treadmill walking.

노이즈 불확실성하에서의 확장칼만필터의 변종들과 코스트 레퍼런스 파티클필터를 이용한 표적추적 성능비교 (Performance Comparison of Various Extended Kalman Filter and Cost-Reference Particle Filter for Target Tracking with Unknown Noise)

  • 신명인;홍우영
    • 한국시뮬레이션학회논문지
    • /
    • 제27권3호
    • /
    • pp.99-107
    • /
    • 2018
  • 본 논문에서는 비선형성을 가지는 측정방정식의 상태값을 효과적으로 추정할 수 있는 확장칼만필터(Extended Kalman Filter/EKF)와 확장칼만필터의 변종들 그리고 코스트 레퍼런스 파티클필터(Cost-Reference Particle Filter/CRPF)를 이용하여 이차원 공간에서 표적추적 성능에 관하여 연구한다. 확장칼만필터의 변종으로 분산점칼만필터(Unscented Kalman Filter/UKF), 중심차분칼만필터(Central Difference Kalman Filter/CDKF), 제곱근 분산점칼만필터(Square Root Unscented Kalman Filter/SR-UKF) 그리고 제곱근 중심차분칼만필터(Square Root Central Difference Kalman Filter/SR-CDKF)를 소개한다. 본 연구에서는 노이즈가 불확실한 표적에 대하여 몬테카를로 시뮬레이션 기법을 이용하여 각 필터들의 평균제곱오차(Mean Square Error/MSE)를 계산하였다. 시뮬레이션 결과 확장칼만필터의 변종들 중에서 제곱근 중심차분칼만필터가 속도와 성능 면에서 가장 우수한 결과를 보여주었다. 코스트 레퍼런스 파티클 필터는 확장칼만필터와 다르게 노이즈의 확률 분포를 알 필요가 없다는 유리한 특성을 가지고 있으며 시뮬레이션 결과 제곱근 중심차분칼만필터보다 처리속도 및 정확도 면에서 우수한 결과를 보여주었다.

Free Surface Flow in a Trench Channel Using 3-D Finite Volume Method

  • Lee, Kil-Seong;Park, Ki-Doo;Oh, Jin-Ho
    • 한국수자원학회논문집
    • /
    • 제44권6호
    • /
    • pp.429-438
    • /
    • 2011
  • In order to simulate a free surface flow in a trench channel, a three-dimensional incompressible unsteady Reynolds-averaged Navier-Stokes (RANS) equations are closed with the ${\kappa}-{\epsilon}$ model. The artificial compressibility (AC) method is used. Because the pressure fields can be coupled directly with the velocity fields, the incompressible Navier-Stokes (INS) equations can be solved for the unknown variables such as velocity components and pressure. The governing equations are discretized in a conservation form using a second order accurate finite volume method on non-staggered grids. In order to prevent the oscillatory behavior of computed solutions known as odd-even decoupling, an artificial dissipation using the flux-difference splitting upwind scheme is applied. To enhance the efficiency and robustness of the numerical algorithm, the implicit method of the Beam and Warming method is employed. The treatment of the free surface, so-called interface-tracking method, is proposed using the free surface evolution equation and the kinematic free surface boundary conditions at the free surface instead of the dynamic free surface boundary condition. AC method in this paper can be applied only to the hydrodynamic pressure using the decomposition into hydrostatic pressure and hydrodynamic pressure components. In this study, the boundary-fitted grids are used and advanced each time the free surface moved. The accuracy of our RANS solver is compared with the laboratory experimental and numerical data for a fully turbulent shallow-water trench flow. The algorithm yields practically identical velocity profiles that are in good overall agreement with the laboratory experimental measurement for the turbulent flow.

반사형 장거리 정밀 변위 감지기용 광학계 설계 및 측정 (Optical System Design and Experimental Demonstration of Long-range Reflective-type Precision Displacement Sensors)

  • 임재인;김승환;이승훈;정해원;이민희;김성환;김경헌
    • 한국광학회지
    • /
    • 제22권3호
    • /
    • pp.151-158
    • /
    • 2011
  • 본 논문에서는 반사형 장거리 정밀 변위 감지기용 광학계를 설계하고 실제 구성을 해 봄으로써 작동 성능을 측정한 결과를 소개하고자 한다. 10 m ~ 250 m 거리에 있는 교량 및 건축물 등의 진동 및 변위를 감지하는 장거리 변위 감지기용 광신호 송신 및 수신용 광학계를 설계하고, 관측 거리에 따라 관측 대상체에 다양한 반사광학계를 설치하여 실제 제작된 변위 감지기의 변위 감지 분해능을 측정하였다. 광신호 송신부는 두 개의 850 nm 파장대 LED와 수렴광학계로 구성되고, 수신부에서는 위치 센서(PSD: Position Sensitive Detector)와 망원형 수렴광학계가 사용되었다. 관측 대상체의 거리에 따라 10 m 거리에서는 0.1 mm 변위 분해능과 250 m 거리에서는 3 mm 이하의 변위 분해능이 가능함을 확인하였다.