• 제목/요약/키워드: Dimensional changes

검색결과 1,579건 처리시간 0.052초

Three-dimensional changes in lip vermilion morphology of adult female patients after extraction and non-extraction orthodontic treatment

  • Liu, Zhi-Yu;Yu, Jie;Dai, Fan-Fan;Jiang, Ruo-Ping;Xu, Tian-Min
    • 대한치과교정학회지
    • /
    • 제49권4호
    • /
    • pp.222-234
    • /
    • 2019
  • Objective: To investigate the three-dimensional lip vermilion changes after extraction and non-extraction orthodontic treatment in female adult patients and explore the correlation between lip vermilion changes and incisor changes. Methods: Forty-seven young female adult patients were enrolled in this study (skeletal Class III patients were excluded), including 34 lip-protruding patients treated by extraction of four first premolars (18 patients requiring mini-implants for maximum anchorage control and 16 patients without mini-implants) and 13 patients requiring non-extraction treatment. Nine angles, seven distances, and the surface area of the lip vermilion were measured by using pre- and post-treatment three-dimensional facial scans. Linear and angular measurements of incisors were performed on lateral cephalograms. Results: There were no significant changes in the vermilion measurements in the non-extraction group. The vermilion angle, vermilion height, central bow angle, height/width ratio, and vermilion surface area decreased significantly after the orthodontic treatment in the extraction groups, but the upper/lower vermilion proportion remained unchanged. Significant correlations were found between the changes in incisor position and those in vermilion angles, vermilion height, and surface area. Conclusions: Extraction of the four first premolars probably produced an aesthetic improvement in lip vermilion morphology. However, the upper/lower vermilion proportion remained unchanged. The variations in the vermilion were closely related to incisor changes, especially the upper incisor inclination changes.

Three-dimensionally Simulated Monofilament Fabrics with Changes in Warp/Filling Yarn Diameter

  • Kim, Jong-Jun
    • 패션비즈니스
    • /
    • 제10권6호
    • /
    • pp.28-37
    • /
    • 2006
  • The purpose of this work is to present three-dimensional models of plain fabrics having various warp and filling yarn diameters. In order to simulate a woven fabric, a 3-dimensional CAD software with NURBS modeling capability was used. Final rendering was performed on the fabric model. It was demonstrated that the changes in yarn diameter could be three-dimensionally modeled through the use of fabric geometry and the 3D CAD. A short RhinoScript program was composed to implement the data importing and model building on the 3D CAD.

동 파이프 성형 시 치수 변화 및 배관 시스템의 기계적 특성 변화 (Changes in Dimension and Mechanical Characteristics of Copper Pipe System during Pipe Processing)

  • 최제민;김수민;채수원
    • 한국정밀공학회지
    • /
    • 제31권7호
    • /
    • pp.615-622
    • /
    • 2014
  • Copper pipes have been widely used as components of System Air-Conditioner due to high thermal conductivity. This system consists of 150 pipes, which are approximately 10m long in total. Dimensional changes occur during pipe processing such as expansion, reduction and bending. This processing induces changes in length of pipes and makes dimensional differences from original pipes. The summation of the differences of pipes components leads to make huge cumulative dimensional differences. The cumulative differences can cause serious problems such as crack, refrigerant leakage. However the differences have not been considered so far. To satisfy target quality of the system, it is essential to predict and calibrate the differences. In this paper, the changes in dimension were predicted using FEM and it was found that cumulative differences could cause indesirable stress during assembly process. As a result, dimensional differences or indesirable stress could be reduced using the proposed method.

멜라민시트 적층 MDF 마루판재의 가열에 의한 치수변화 (Dimensional Change of Melamine Sheet Laminated MDF Flooring by Heating)

  • 민일홍;김의식;한규성
    • Journal of the Korean Wood Science and Technology
    • /
    • 제24권4호
    • /
    • pp.32-39
    • /
    • 1996
  • The overall purpose of this study was to investigate the dimensional changes of melamine sheet laminated medium density fiberboard(MDF) floorings by sub-heating system(Ondol). This study was also conducted to improve the properties of melamine sheet laminated MDF floorings. The effects of density, resin content, manufacturing speed of MDF and types of melamine sheet on dimensional and weight changes of floorings were investigated. The results were as followings. 1. Dimensional and weight change of melamine sheet laminated MDF flooring by heating decreased with decreasing the density of MDF. 2. Dimensional and weight change of melamine sheet laminated MDF flooring by heating decreased with increasing the resin content of MDF. 3. Dimensional and weight change of melamine sheet laminated MDF flooring by heating decreased with decreasing the manufacturing speed of MDF. 4. Dimensional change of melamine sheet laminated MDF flooring in width direction by heating was doubled than that in machine direction. 5. Dimensional change and curling of high pressure melamine laminate(HPM) laminated MDF flooring by heating was less than those of low pressure melamine laminate(LPL) flooring. 6. Weight loss of melamine sheet laminated MDF flooring by heating has linear relationship with shrinkage.

  • PDF

Morphology of the Aging Forehead: A Three-Dimensional Computed Tomographic Study

  • Yi, Hyung Suk
    • 대한두개안면성형외과학회지
    • /
    • 제16권2호
    • /
    • pp.58-62
    • /
    • 2015
  • Background: Age-related changes have been studied for lower and middle facial bones. Although the forehead comprises one-third of the facial area, no studies have investigated age-related changes in the upper part of the face or forehead. The purpose of this study was to use three-dimensional computed tomography (3D CT) to investigate age-related changes in the frontal bone. Methods: A retrospective review was performed for patients who underwent 3D CT scan of facial bones. Patients were divided by gender and age (20 to 40 years, 41 to 60 years, and above 60 years). The frontal bone curvature was evaluated by the length of frontal bone and by two frontal bone angles in relation to the Frankfurt horizon. Results: In both genders, aging was associated with increasing lower slope length. In elderly men (>60 years), the upper slope angle was significantly higher when compared to younger male subjects. Women demonstrated similar age-related changes, but the differences were only statistically significant for the middle and older age groups. Conclusion: This study demonstrates quantifiable age-related changes in the frontal bone. These findings contribute to the understanding of age-related changes of the facial soft tissues. The mean measurements in each age group can be used as a reference when planning forehead reconstruction.

Holographic interferometry를 이용한 열중합 애크릴릭 레진의 변형에 관한 연구 (A STUDY ON THE DIMENSIONAL CHANGES OF HEAT CURING ACRYLIC RESINS USING HOLOGRAPHIC INTERFEROMETRY)

  • 박동관;장익태;김광남
    • 대한치과보철학회지
    • /
    • 제33권1호
    • /
    • pp.48-74
    • /
    • 1995
  • Since heat curing acrylic resins undergo unavoidable dimensional changes following polymerization, adaptation can be altered. Until recently, although numerous studies on the dimensional changes of denture base were based on a microscopic technic that measures the relative displacement of a limited reference points on the denture base, but there have been few studies on the distortions of resins using holographic interferometry. Purpose of this study was to determine and compare the dimensional changes and fringe patterns of 4 heat curing acrylic resins, and observe the distortions of acrylic resin denture base by temperature change with the aid of the holographic interferometry. Holographic interferograms were taken on the resin specimens and acrylic resin denture base with the 10mW He-Ne laser and double exposure method. Comparison and analysis of fringe pattern on the recorded object surface was performed. The following results were obtained. 1. The dimensional changes for the high impact resin Lucitone 199 were statistically the greatest of all resins, and the rapid heat curing resin Premium super 20 were the least. 2. The most polymerization shrinkage of all materials occured in initial period of measurements, at this time the difference of polymerization shrinkage properties between resins was founded. 3. The stress distribution of specimens was seen by various type of fringe pattern which had directionality. 4. The polymerization shrinkage of resins was greatly influenced by temperature change. 5. The partial deformations of resin denture base were observed in 70 C and 90 C water.

  • PDF

미세성형품의 정밀 냉간단조시 치수변화 분석 (Dimensional change of micro forged part on precision cold forging)

  • 이명원;이영선;이정환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 추계학술대회 논문집
    • /
    • pp.254-258
    • /
    • 2008
  • Dimensional accuracy is very important quality in micro forged part, especially on forged part. Dimension of forged part is changed continuously during forging process. Loading, unloading and ejecting stage affects dimensional of the forged tool. The elasto-plastic material model for billet and elastic model for die were used to analyze these changes. At same time, the calculated results were compared and analyzed by the experiment on same conditions. From the experimental and analytical studies, we can calculated the amount of difference between die and forged part, that is 0.49% based on the die dimension. The dimensional change is smaller than that of general sized-forged part,0.6%.

  • PDF

얼굴인증 방법들의 조명변화에 대한 견인성 비교 연구 (Study On The Robustness Of Face Authentication Methods Under illumination Changes)

  • 고대영;김진영;나승유
    • 정보처리학회논문지B
    • /
    • 제12B권1호
    • /
    • pp.9-16
    • /
    • 2005
  • 본 논문은 얼굴인증 시스템 구현과 조명변화에 견인한 얼굴인증 방법들에 관한 연구에 초점을 둔다. 얼굴인증 시스템 구현을 위한 방법으로 PCA(Principal Component Analysis), GMM(Gaussian Mixture Models), 1차원 HMM(1 Dimensional Hidden Markov Models), 준 2차원 HMM(Pseudo 2 Dimensional Hidden Markov Models) 방법을 이용한다. 네 가지 다른 얼굴인증 방법들의 조명변화에 대한 성능비교 실험을 수행한다. 조명변화실험을 위해 얼굴이미지의 왼쪽에서 오른쪽으로 인공적인 조명효과(${\delta}=0,40,60,80$)를 준다. 얼굴특징벡터는 얼굴이미지에서 분할한 각 블록에 대한 2D DCT(2 Dimensional Discrete Cosine Transform) 계수를 이용하고 실험은 ORL(Olivetti Research Laboratory) 얼굴데이터베이스를 사용한다. 실험결과 모든 경우 조명변화 값이 커질수록 성능저하가 발생한다. 또한 조명변화가 없는 경우(${\delta}=0$) 준 2차원 HMM이 $2.54{\%}$, 1차원 HMM이 $3.18{\%}$, PCA가 $11.7{\%}$, GMM이 $13.38{\%}$의 EER(Equal Error Rate) 성능을 나타낸다. 조명변화가 없는 경우(${\delta}=0$) 1차원 HMM 방법이 PCA 방법보다 좋은 성능을 나타내지만 조명변화 ${\delta}{\geq}40$인 때에는 반대로 PCA 방법이 더 좋은 성능을 나타낸다. 마지막으로 준 2차원 HMM의 경우 조명변화에 관계없이 가장 좋은 EER성능을 나타낸다.

친수성 고무인상재의 침적 소독이 경석모형의 크기의 안정성과 표면경도에 미치는 영향 (EFFECT ON IMMERSI0N DISINFECTION OF HYDROPHIILIC RUBBER IMPRESSI0N MATERIAL ON DIMENSIONAL STABILITY AND SURFACE HARDNESS OF IMPROVED STONE CAST)

  • 남미현;강우진;정문규
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.569-583
    • /
    • 1995
  • Disinfection of dental impressions are necessary due to contamination with patient’s saliva and blood, which is a potential for cross-infection. The purpose of this study was to evaluate the effects of disinfection of four hydrophilic rubber impression materials with three disinfecting solutions, on the dimensional stability and surface hardness of improved stone casts. Three hydrophilic vinyl polysiloxane impression materials(Express, Reprosil, Exafine) and one polyether impression material(Impregum-F) were mixed according to the manufacturer’s directions and impressions were made on a ADA specification No. 19 stainless-steeldie. On removal of the impressions, each impression was immersed in one of the disinfectants(Banicide, Potadine, Clorox) for 10 minutes. After disinfection, type IV improved stone. casts were poured. On this cast, the linear dimension and surface hardness were measuredusing a Measurescope(Nikon, Japan) and a Barcol hardness tester(Barber, Colman Co U. S. A). The results were as follows : 1. The improved stone casts from disinfected Reprosil and Impregum-F impression material did not show dimensional changes(P>0.01). Those from disinfected Express and Exafine impression material showed dimensional changes(P<0.01). The amount of shrinkage was not clinically significant. 2. The improved stone casts from disinfected Express impression material did not exhibit changes in surface hardness(P>0.01), but those from disinfected Reprosil, Exafine, Imp regnum-F impression material showed changes in surface hardness(P<0.01). 3. The dimensinal stability and surface hardness of the improved stone casts were satisfactory using Banicide on Express, all disinfectants used in this study on Reprosil, Potadin and Clorox on Exafine, Banicide and Clorox on Impregum-F. According to these results, immersion disinfection of hydrophilic rubber impression mate rials did not adversely affect the resultant casts. Nevertheless compatibility tests of impression materials and disinfectants should be done when disinfecting impressions.

  • PDF