• Title/Summary/Keyword: Dilution test

Search Result 394, Processing Time 0.025 seconds

A Study on the River Discharge Measurement Techniques (하천유량 측정기법에 관한 연구)

  • 김성원;지홍기
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.793-801
    • /
    • 1998
  • In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Infection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzed that the estimated error of constant-rate-injection method is less than that of the slug-in-jection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can't be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.

  • PDF

Estimation in Group Testing when a Dilution Effect exists

  • Kwon, Se-Hyug
    • Communications for Statistical Applications and Methods
    • /
    • v.13 no.3
    • /
    • pp.787-794
    • /
    • 2006
  • In group testing, the test unit consists of a group of individuals and each group is tested to classify units from a population as infected or non-infected or estimate the infection rate. If the test group is infected, one or more individuals in the group are presumed to be infected. It is assumed in group testing that classification of group as positive or negative is without error. But, the possibility of false negatives as a result of dilution effects happens often in practice, specially in many clinical researches. In this paper, dilution effect models in group testing are discussed and estimation methods of infection rate are proposed when a dilution effect exists.

Comparison of the E-Test with Agar Dilution Susceptibility Test by Using Bacteroides fragilis (Bacteroides fragilis의 E-test와 한천 평판 희석법에 의한 항균제 감수성상의 비교)

  • Kim, Hee-Sun;Kim, Sung-Kwang;Cha, Hwa-Sun
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.135-143
    • /
    • 1993
  • The susceptibilities of 45 clinical isolates of bacteroides frogilis to cefaclor, ciproflxacin and imipenem were determined by new method, E-test (AB Bidisk, Solna, Sweden) and were compared with those from conventional agar dilution method by using brain heart infusion, Mueller-Hinton and Wilkins Chalgren agar plates. And the susceptibility of 60 clinical isolates of Bacteroides fragilis group (B. fragilis 45 strains, B. distasonis 6 strains, B. ovatus 5 strains, B. thetaiotaomicron 4 strains) to 5 quinolones (ciprofloxacin, enoxacin, norfloxacin, ofloxacin, pefloxacin) were determined by in vitro agar dilution method. Compared with agar dilution MICs for B. fragilis 45 strains, 90.3% of E-test MICs were within ${\pm}$1 dilution of the agar dilutions, and 98.4% were within 2 dilutions. And there were little effect of different medium bases to determine MICs except Mueller-Hinton agar. On Mueller-Hinton agar, B. fragilis showed have or no growth activity. In vitro susceptibility of B. fragjlis group to quinolones, most of the test strains showed resistant patterns to quinolones except ofloxacin and there was little difference of susceptibility patterns between species of B. fragilis group.

  • PDF

Antimicrobial efficacies of alkaline disinfectant solution and commercial disinfectants against Brucella ovis

  • Yoo, Jong-Hyun
    • Korean Journal of Veterinary Service
    • /
    • v.32 no.4
    • /
    • pp.347-351
    • /
    • 2009
  • Bruella spp. involves a considerable danger of public health and farm animal industry. In this study, we assessed the disinfection efficacy of alkaline disinfectant solution and three commercial farm disinfectants (quaternary ammonium compound, sodium dichloroisocyanurate, potassium monopersulphate/sodium dichloroisocyanurate) against Brucella ovis. A bactericidal efficacy test by broth dilution method was used to determine the lowest effective dilution of selected disinfectants following exposure to test bacteria for 30 minutes at $4^{\circ}C$. Disinfectants and test bacteria are diluted with distilled water (DW), hard water (HW) or organic matter suspension (OM) according to treatment condition. Three commercial disinfectant showed excellent antimicrobial activity (up to dilution of $\times200$ in OM treatment). Alkaline disinfectant solution demonstrated favorable bactericidal efficacy against B. abortus (at dilution of $\times20$ in OM treatment). Three commercial farm disinfectants possess excellent efficacy against B. ovis. Alkaline disinfectant solution has lower potency than commercial farm disinfectant but could help to limit the spread of brucellosis.

Wear performance of Plasma Transferred Arc deposited layers

  • Yoon, Byoung-Hyun;Kim, Hyung-Jun;Lee, Chang-Hee
    • Proceedings of the KWS Conference
    • /
    • 2001.05a
    • /
    • pp.245-247
    • /
    • 2001
  • In this study, the effects of dilution on the wear behavior of PTAW (Plasma Transferred Arc Welding) Inconel 625, Inconel 718 and Stellite 6 overlays on Nimonic 80A were investigated. Inorder to evaluate the wear performance, two-body and three-body abrasive wear test, and dry sliding wear test were performed. According to wear tests, the wear rate of deposit with dilution 30% was higher than that of dilution 10% by 10%, and it was also found the plastic deformation near worn surface.

  • PDF

Engineering Characteristics of Light-weight Foamed CLSM using Coal Ash According to Final Mixing Time and Dilution Ratio (석탄회를 활용한 경량기포 저강도 고유동화재의 최종비빔시간과 희석비에 따른 공학적 특성)

  • Lee, Jong Hwi;Na, Jeong Hum;Lee, Chang Ki;Chun, Byung Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1C
    • /
    • pp.17-25
    • /
    • 2012
  • CLSM (Controlled Low Strength Material) using coal ash, which has the advantages of self-leveling, self-compacting, flowability, easy re-excavation, has been developed. In this study, CLSM additionally mixed with foaming agent for structural backfill material, aimed at lightness of materials, was developed called light-weight foamed CLSM. As the basic study of this material, to determine the optimum final mixing time and dilution ratio of existing light-weight foamed CLSM, flow, slurry unit weight and unconfined compressive strength test according to each impact factor were performed at the standard mix proportion. As the results of tests, CASE N (Final mixing time 4 min, dilution ratio 2%), CASE O (Final mixing time 3 min, foam agents ratio 3%, dilution ratio 2%) were satisfied with the standard of flow test (above 20cm), slurry unit weight test (12~15 $kN/m^3$) and unconfined compressive strength test (800 kPa~1200 kPa). These results will indicate the standard optimum final mixing time and dilution ratio of light-weight foamed CLSM for structural backfill.

Verification of the upper limit of results through dilution tests for RIA test (RIA 검사별 희석실험을 통한 결과의 상한치 검증)

  • LEE, Geun Ui;CHOI, Jin Ju;LEE, Young Ji;YOO, Seon Hee;LEE, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.42-46
    • /
    • 2022
  • Purpose In the meantime, there have been not many samples that require dilution, and it has been difficult for the examiner to set an appropriate dilution multiple for RIA test item and report the results. Accordingly, it was judged that it was necessary to set the maximum dilution multiple for each test and to verify the upper limit of the clinical reportable range. Therefore, in this study, the maximum dilution multiple for each RIA test was set and the upper limit of the clinical reportable range was verified accordingly Materials and Methods Among all RIA tests conducted at Asan Medical Center, the study treated on 30 types of tests which also conduct the dilution test. Data from March to July 2021 were collected and analyzed. The study was conducted on samples subjected to serial dilutions such as X2, X4 or X10, X102, X103, X104, X105. Results Among a total of 30 test types, 18 test types have more than 5 N values in the tolerance range of 80~120%. As a result of the verification of maximum dilution multiples, the test set to 104 is 𝛼-fetoprotein and thyroglobulin, and the test set to 103 is CA-125, CEA, and 𝛽-hCG, and the test set to 102 is Free PSA, PSA, CA15-3, SCC, Ferritin, PTH, Cortisol, and Calcitonin. Tests set to 10 include three categories: 𝛽2-Microglobulin, C-peptide, and Testosterone. Conclusion It is expected that it will contribute to improving the quality of nuclear medicine blood tests as the results of dilution experiments can be reported quickly and accurately through the verification of the clinical reportable range.

Detection of IgG and IsM Antibodies with Immunofluoreseent Antibody Technique in Buman Trichomoniasis (질트리코모나스증에서 간접형광항체법을 이용한 혈청내 항질트리코모나스 IgG 및 IgM 항체의 측정)

  • 윤경찬;김경민;안명희;민득영;차동수
    • Parasites, Hosts and Diseases
    • /
    • v.25 no.1
    • /
    • pp.7-12
    • /
    • 1987
  • The indirect fluorescent antibody(IFA) test was used to detect serum IgG and IgM antibodies to Trichomonas vaginalis in 31 vaginal trichomoniasis, 7 candidiasis and in 20 non-infected healthy women with antigen prepared from axonic culture of Trichomenas vaginalis isolated from vulvovaginitis patient. The results were as follows: 1. In 31 vaginal trichomoniasis the positive reactions of IgG antibody were 27 in the 1/8 dilution or higher and :l in the 1/4 dilution whereas in healthy women the reaction showed significantly low as in the 1/4 dilution or below. 2. The sensitivity and specificity of IFA test for IgG antibody to trichomonad antigen in this study were 87.1% and 100%, respectively. 3. No significant difference of IgM antibody levels between vaginal trichomoniasis and healthy women was observed. 4. No relation between the levels of IgG and IsM antibodies to trichomonad antigen by IFA test was observed. 5. No relation between the time lapse and the level of serum IgG antibodies in IFA test of vaginal trichomoniasis was regarded. In conclusion the present study suggests that IFA test in trichomoniasis could be a useful tool for detection of anti-trichomonad IgG antibodies and applicable as an immunodiagnostic method.

  • PDF

Sensory Characteristics of Diluted Espresso(Americano) in Relation to Dilution Rates (에스프레소 희석 커피(아메리카노)의 희석 배수에 따른 관능적 특성)

  • Lee, Seung-Yeon;Hwang, In-Kyeong;Park, Mi-Hyun;Seo, Han-Seok
    • Korean journal of food and cookery science
    • /
    • v.23 no.6
    • /
    • pp.839-847
    • /
    • 2007
  • The aims of this study were twofold: i) to investigate changes in the sensory characteristics and consumer preference of diluted espresso drinks according to different dilution rates; ii) to compare the physicochemical characteristics between diluted espresso coffees, using the preferred coffee of this study and commercial products from coffee shop chains. Descriptive analysis using a 15 cm line scale, and a consumer preference test were carried out by 6 trained panelist,; and 50 consumers (F=39, M=11), respectively. Appearance (transparent, black), odor (bitter, rich), taste (bitter, burnt, astringent, umami, sour), and mouth-feel (aftertaste, body, coarseness, oily, roughness, soft-swallowing) were significantly different among the 3-, 5-, 7-, 9-, and 11-times dilution rates. In particular, the sensory characteristics associated with mouth-feel showed obvious differences with the dilution rates. In the consumer preference test, the 9-times diluted espresso had the highest preference, whereas the 3-times diluted espresso showed the lowest preference. Moreover, the 9-times diluted espresso demonstrated similar physicochemical characteristics such as pH, sugar content, and total solid content to those of the commercial diluted espresso drinks from coffee shop chains. In conclusion, the sensory characteristics and consumer preference of the diluted espressos were influenced by the dilution rates.

A Case Study of Prediction and Analysis of Unplanned Dilution in an Underground Stoping Mine using Artificial Neural Network (인공신경망을 이용한 지하채광 확정선외 혼입 예측과 분석 사례연구)

  • Jang, Hyongdoo;Yang, Hyung-Sik
    • Tunnel and Underground Space
    • /
    • v.24 no.4
    • /
    • pp.282-288
    • /
    • 2014
  • Stoping method has been acknowledged as one of the typical metalliferous underground mining methods. Notwithstanding with the popularity of the method, the majority of stoping mines are suffering from excessive unplanned dilution which often becomes as the main cause of mine closure. Thus a reliable unplanned dilution management system is imperatively needed. In this study, reliable unplanned dilution prediction system is introduced by adopting artificial neural network (ANN) based on data investigated from one underground stoping mine in Western Australia. In addition, contributions of input parameters were analysed by connection weight algorithm (CWA). To validate the reliability of the proposed ANN, correlation coefficient (R) was calculated in the training and test stage which shown relatively high correlation of 0.9641 in training and 0.7933 in test stage. As results of CWA application, BHL (Length of blast hole) and SFJ (Safety factor of Joint orientation) show comparatively high contribution of 18.78% and 19.77% which imply that these are somewhat critical influential parameter of unplanned dilution.