Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구 (Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction)

  • 소성수;노현수;김창성;최성호;김기덕;조규성
    • Journal of Periodontal and Implant Science
    • /
    • 제32권1호
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.

심장병 진단을 위한 실시간 디지탈 감산 조영 영상기법의 개발 (Development of Cardiac Digital Subtraction Angiographic System for Diagnosis of Cardiac Diseases)

  • 민병구;이태수
    • 대한전자공학회논문지
    • /
    • 제26권2호
    • /
    • pp.132-139
    • /
    • 1989
  • 본 연구에서는 심장의 박동영상을 방사선 투시법으로 관찰하여 심장질환을 진단하기 위한 실시간 처리 심장 디지탈 감산 조영 영상기법(cardiac digital subtraction angiography)을 개발하여 임상실험을 시행하였다. 평균 1초에 1번의 심장박동에 따른 주변부위의 운동에 의한 오차의 영향을 감소하면서, 좌심실 박동상을 32프레임까지 실시간으로 감산 처리하는 고속기억(512X512 해상도와 256 gray level) 및 고속 데이타링크 시스템과 프로세서를 개발하였다. 기억된 영상을 컴퓨터에 입력하고, 심장의 경계면을 Dynamic Programming을 사용하여 검출하고, 부피를 구하여 심장의 박동에 따른 최대부피(ESV)와 박동후 최소부피(ESV), 최대와 최소부피의 비율(EF)로서 표시되는 심박출계수 등 심장의 좌심실기능을 나타내는 생리계수를 영상으로 부터 구하는 알고리듬을 개발해서 임상실험을 시행하였다.

  • PDF

짧은 임플란트의 생존율과 변연골 흡수량에 관한 임상적 연구 (Clinical Study on the Survival Rate and Marginal Bone Resorption of Short Implants)

  • 명태수;정승현;김태영;김유리
    • 구강회복응용과학지
    • /
    • 제28권1호
    • /
    • pp.1-13
    • /
    • 2012
  • 짧은 임플란트는 상악동이나 하치조신경 등의 해부학적 구조물이 있거나 심한 치조골 흡수로 인해 제한적인 치조제 높이를 가지는 부위에서 사용되고 있다. 본 연구는 길이 10 mm 이하의 임플란트에서 임플란트의 길이, 직경, 식립 부위, 골이식술 유무, 보철물의 연결고정 유무가 임플란트의 생존율과 변연골 흡수에 미치는 영향을 알아보고자 하였다. 원광대학교 치과병원 임플란트센터에서 길이 10 mm 이하의 임플란트를 식립한 137명의 환자, 227개 임플란트를 대상으로 진료 기록부를 통해 임플란트의 길이, 직경, 식립 위치, 골이식 유무, 보철물의 연결고정 유무를 조사하였다. 변연골 흡수량은 Emago advanced v5.6(Oral diagnostic systems, Amsterdam, The Netherlands) 프로그램을 이용하여 측정하였다. 총 227개의 임플란트 중 8개가 실패하여, 전체 짧은 임플란트의 생존율은 96.5 %로 나타났다. 골이식 부위와 상악에 식립된 경우 더 높은 실패율을 보이는 경향이 있었으며, 임플란트의 길이와 직경은 변연골 흡수량에 영향을 미치지 않았다. 실패 요인을 조사하였을 때, 상악의 불량한 골질과 골이식 유무가 임플란트의 더 높은 실패율에 영향을 미쳤다. 10 mm 이하 임플란트에서 길이, 직경, 식립 부위, 골이식술과 보철물의 연결 고정은 임플란트 생존율과 변연골 흡수량에 영향을 끼치지 않았다.