• 제목/요약/키워드: Digital radiography(DR)

검색결과 89건 처리시간 0.027초

A Study of the Relationship between Absorbed Energy and DR Pixel Values Using SPEC-78

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyun;Ho, Dong-Su;Choe, Bo-young;Suh, Tae-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.69-69
    • /
    • 2003
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed energy. The visible light photons are converted into an electric signal in the amorphous silicon photodiode. In order to produce good quality images, we need to understand the detailed behavior of DR detectors in radiation. We, therefore, investigated the relationship between DR outputs and X -ray in terms of absorbed energy, using the SPEC-78, X-ray energy spectrum model. We calculated the total filtration of X-ray equipment measuring air exposure and this value was used in the calculation of absorbed energy. The relationship between DR output and the absorbed energy of the X-ray was obtained by matching the absorbed energy with pixel values of real images under various conditions. It was found that the relationship between these two values was almost linear. The results were verified using phantoms made of water and aluminium. The pixel value of the phantom image was estimated and compared with previous results under various conditions. The estimated pixel value coincided with the results, although the effect of scattered photons introduced some errors.

  • PDF

X선 기기의 자동화를 위한 BLDC 모터 제어 장치 (BLDC Motor Control Unit for Automation of X ray Equipment)

  • 김태곤;김영표;천민우
    • 한국항행학회논문지
    • /
    • 제15권5호
    • /
    • pp.833-838
    • /
    • 2011
  • 진단용 X선 기기는 다양한 장치의 개발에 힘입어 보다 효과적이고 정밀한 진단이 가능하게 되었다. 정밀 진단이 가능하게 되면서 X선 기기는 임상의학에 있어 가장 기본적이고 핵심적인 진단 장치로 자리 잡고 있다. X선을 이용한 영상획득 분야에서는 영상의 획득 시간 단축과 전송이 용이하고, 조사선량의 감소가 가능한 DR(Digital Radiography)의 사용이 확대되고 있다. 하지만 DR은 1개의 디텍터를 이용하는 구조로 되어있어 기존의 X선 장치와는 달리 구조적인 변경이 필요하며 촬영위치에 따라 디텍터를 원하는 위치까지 움직여야하는 단점을 가진다. 따라서 본 연구에서는 BLDC 모터와 PID 제어방식을 사용해 DR에서 가장 움직임이 많은 디텍터의 상하, 좌우, 회전의 3축 위치자동 제어 시스템을 설계 제작하고 그 성능을 평가 하였다.

다양한 관전압에 따른 CR과 DR 모의병변 흉부 영상의 ROC 평가 (ROC Analysis of Simulated Chest Lesions for Computed Radiography and Digital Radiography at Various Tube Voltages)

  • 조효민;김희중;이창래;정지영;박혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.298-304
    • /
    • 2008
  • 본 연구에서는 다양한 관전압 사용에 따른 CR, DR 모의병변 흉부 영상을 이용하여 병변 검출 정도를 ROC 평가하였다. 모의 제작된 미세 폐 병변, 초기 침윤성 병변, 작은 혹 모양의 병변은 아크릴 판을 이용하여 인체형 흉부 팬텀과 포개놓고 영상을 획득하였으며 CR과 DR에서 각각 3개의 관전압(70 kV, 90 kV, 120 kV) 조건을 사용하였다. 총 18,000개의 관찰결과를 ROC평가 하였다. CR에서는 모든 병변에 대하여 70 kV로 획득한 영상이 높은 $A_z$값을 나타내었으나 DR에서는 두 개 병변에서만 70 kV로 획득한 영상이 높은 $A_z$값을 나타내었다. 본 연구내용을 바탕으로 검출기 종류와 관심 병변에 따른 최적의 관전압 조건을 사용하기 위하여 실제 환자에서의 임상 연구가 필요할 것으로 사료된다.

  • PDF

디지털 영상에서 화질관리에 관한 노출지수(EI)의 유용성 연구 (The Review of Exposure Index in Digital Radiography and Image Quality)

  • 양숙;한재복;최남길;이성길
    • Journal of Radiation Protection and Research
    • /
    • 제38권1호
    • /
    • pp.29-36
    • /
    • 2013
  • CR과 DR 장비에서 팬텀을 이용하여 선량과 노출지수(exposure index, EI)의 변화를 관찰하고 처리된 영상에서 NSR(noise to signal ratio)과 CNR (contrast to noise ratio)을 측정하여 디지털 시스템에서 방사선량을 최적화하기 위한 인자들 간의 상관관계를 알아보고자 하였다. EI와 입사표면선량(entrance surface dose, ESD)는 CR과 DR 장비에서 모두 주어진 선량의 증가에 따라 비례하여 증가하였다. 적정범위 내 EI 산출시 CR의 경우 DR 보다 더 많은 선량이 요구되었으나 두 시스템에서 모두 EI 지표는 노출인자인 kVp, mAs의 증가에 대해 선형으로 비례하여 증가하였다. 특히, 검출기 효율이 우수한 DR 시스템에서는 선량 변화에 대해 더 안정된 감도를 나타내었고, 최소의 선량증가에도 영상의 유용한 대조도를 형성하여 화질의 향상에 쉽게 도달할 수 있었다. 이는 검출기 흡수선량과 밀접한 관련이 있는 EI 지표의 정확성을 예측 가능하게 하였다. EI의 물리적 특징과 영상평가를 위한 NSR 측정은 DR 시스템에서 CR 보다 더 낮은 NSR이 나타났으며 CR에서는 6 mAs이상의 관전류에서는 관전압의 값에 따른 영향이 상대적으로 적었다. 본 연구 결론은 디지털 시스템 검출기의 흡수선량 측정의 지표인 EI는 노출인자와 선형비례관계에 있었고 EI가 제조사에서 제공한 범위 내에 존재할 때 그 EI 지표가 우수할수록 최적의 영상화질을 얻을 수 있었다. 또한 디지털 방사선 영상 기술에서 EI의 물리적 특징의 활용은 실제 임상에서 영상의 화질향상에 도움을 주고 검출기의 품질관리를 통하여 환자의 불필요한 피폭선량을 줄이는 데 많은 기여를 할 수 있을 것이다.

의료용 디지털방사선영상의 공간분해능 최적화에 의한 소듐냉각고속로 연료봉 내부의 소듐 충전상태 평가 (Evaluation of the Filling Sodium States Inside the Fuel rod of Sodium-Cooled Fast Reactor by Optimized Spatial Resolution in Medical Digital Radiographic Images)

  • 성열훈
    • 한국방사선학회논문지
    • /
    • 제10권2호
    • /
    • pp.117-124
    • /
    • 2016
  • 본 연구에서는 디지털 의료용 X선을 이용하여 소듐냉각고속로 금속연료봉 내부의 소듐 충전상태를 평가하고자 하였다. 의료용 X선은 디지털방사선(digital radiography, DR)시스템을 사용하였다. 최상의 공간분해능을 도출하기 위해 X선관의 초점크기와 디지털영상후처리 방법을 변화시켰다. 이때 텅스텐을 이용한 에지방법의 변조전달함수(modulation transfer function, MTF)를 사용하여 선예도(0.5 MTF)와 해상도(0.1 MTF) 를 평가하였다. 그 결과 소초점에서 영상후처리의 대조도를 강화시킨 조건에서 3.871 lp/mm (0.1 MTF)와 3.290 lp/mm (0.5 MTF)의 공간분해능을 얻었다. 결론적으로 이러한 결과는 디지털 의료용 X선을 이용하여 소듐냉각고속로 금속연료봉 내부의 소듐 충전상태를 관찰할 수 있었다.

Proposed Institutional Diagnostic Reference Levels in Computed and Direct Digital Radiography Examinations in Two Teaching Hospitals

  • Emmanuel Gyan;George Amoako;Stephen Inkoom;Christiana Subaar;Barry Rahman Maamah
    • Journal of Radiation Protection and Research
    • /
    • 제48권1호
    • /
    • pp.9-14
    • /
    • 2023
  • Background: The detectors of both computed radiography (CR) and direct digital radiography (DR) have a wide dynamic range that could tolerate high values of exposure factors without an adverse effect on image quality. Therefore, this study aims to assess patient radiation dose and proposes institutional diagnostic reference levels (DRLs) for two teaching hospitals in Ghana. Materials and Methods: CR and DR systems were utilized in this study from two teaching hospitals. The CR system was manufactured by Philips Medical Systems DMC GmbH, while the DR system was manufactured by General Electric. The entrance skin doses (ESDs) were calculated using the standard equation and the tube output measurements. Free-in-air kerma (µGy) was measured using a calibrated radiation dosimeter. The proposed institutional DRLs were estimated using 75th percentiles values of the estimated ESDs for nine radiographic projections. Results and Discussion: The calculated DRLs were 0.4, 1.6, 3.4, 0.5, 0.4, 1.1, 1.0, 1.2, and 1.7 mGy for chest posteroanterior (PA), lumbar spine anteroposterior (AP), lumbar spine lateral (LAT), cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively in CR system. In the DR system, the values were 0.3, 1.6, 3.1, 0.4, 0.3, 0.7, 0.6, 0.9, and 1.3 for chest PA, lumbar spine AP, lumbar spine LAT, cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively. Conclusion: Institutional DRLs in nine radiographic projections have been proposed for two teaching hospitals in Ghana for the first time. The proposed DRLs will serve as baseline data for establishing local DRLs in the hospitals and will be a valuable tool in optimizing patient doses.

디지털 방사선 시스템(DR)의 자동노출제어장치 이용 시 이온 챔버의 성능 평가를 위한 엔트로피 분석법의 유용성과 최적의 챔버 조합 모델 구현 연구 (Study on Usefulness of Entrance Surface Dose (ESD), Entropy Analysis Method to Evaluate Ionization Chamber Performance and Implementation of Optimal Chamber Combination Model when using Automatic Exposure Control (AEC) Device in Digital Radiography (DR))

  • 황준호;최지안;이경배
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.375-383
    • /
    • 2020
  • 본 연구는 자동노출제어장치 사용 시 이온 챔버의 성능과 조합에서 비롯된 문제를 정량적으로 분석하는 방법론을 제시하고 디지털 방사선 시스템의 성능을 최적화하고자 하였다. 실험방법은 복부와 골반부 검사에 사용된 파라미터의 X선질을 백분율 평균오차(PAE; Percentage Average Error)와 반가층(HVL; Half Value Layer)으로 평가하였다. 그 후 세 가지 이온 챔버를 조합했을 때의 입사표면선량(ESD; Entrance Surface Dose)과 엔트로피(Entropy)를 산출하여 방사선 출력의 안정성과 영상 품질을 분석하였다. 그 결과 실험에 사용한 디지털 방사선 시스템의 X선질은 모두 정상 범위의 백분율 평균오차와 반가층을 보였다. 입사표면선량은 챔버의 조합에 비례하여 증가하였고, 엔트로피는 세 개의 챔버가 조합됐을 때를 제외하고는 이온 챔버의 조합에 비례하여 증가하였다. 결론적으로 입사표면선량과 엔트로피를 이용한 분석은 이온 챔버의 성능과 조합의 문제를 평가하는데 유용한 방법인 것을 알 수 있었으며, 두 개 이하의 이온 챔버를 조합했을 때 디지털 방사선 시스템의 성능을 최적으로 유지할 수 있음을 알 수 있었다.

DR Responses to X-Ray: in Terms of Absorbed Energy

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyeon;Ho, Dong-Su;Suh, Tae-Suk;Choe, Bo-Young
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.389-392
    • /
    • 2002
  • Digital radiography (DR) is being developed for numerous applications in medical imaging. For understanding DR image, it is necessary to comprehend DR responses to X-ray in terms of absorbed energy. This study reports on the relationship of absorbed energy in the scintillator vs. pixel value of detector. Pixel value and exposure were measured from 50 kVp to 120 kVp until the detector was saturated. For representing radiation produced at the X-ray tube, we used program Srs-78 and compared experimental exposure with calculated exposure. Absorbed energy was acquired using spectrum and we got the relation between the two values.

  • PDF

방사선 디텍터의 Noise Power Spectrum: I. 영상의 평균을 사용한 측정 (Noise Power Spectrum of Radiography Detectors: I. Measurement Using the Averages of Images)

  • 김동식;이은애
    • 전자공학회논문지
    • /
    • 제53권12호
    • /
    • pp.120-127
    • /
    • 2016
  • 디지털 x선 영상을 획득하기 위하여 최근에는 DR(digital radiography) 기술에 근거한 방사선 디텍터의 개발이 활발하게 진행되고 있다. 이러한 방사성 디텍터의 잡음 특성은, 균일한 노출에서 획득한 영상을 사용하여 NNPS(normalized noise power spectrum)를 측정하여 관찰한다. 이때 고정형태잡음(fixed pattern noise)을 제거하기위하여 두 장의 영상 차를 사용한다. 본 논문에서는 보다 정확한 NNPS를 측정하기 위하여, 먼저 여러 장의 영상을 획득하여 두 장의 평균영상을 구하고 그의 차를 사용하여 NNPS를 구하는 방법을 제안하였다. 이때 여러 장의 영상들의 평균으로 인하여 NNPS 값이 실제 값보다 작아지는데, 이러한 NNPS의 보정을 위하여, 평균할 때 사용한 영상 개수의 함수인 보정 상수도 함께 제안하였다. 또한 평균영상의 비를 사용하여 NNPS를 구하는 방법도 제안하였다. 실제 방사선 디텍터에서 획득한 영상을 사용하여 NNPS를 측정하는 실험을 통하여, 제안한 방법으로 NNPS 보다 정확하게 구할 수 있음을 관찰하였다.

DR 영상 전처리 알고리즘 및 실시간 구현을 위한 하드웨어 설계에 관한 연구 (A Study on DR Image Processing Algorithm and Hardware System for Real Time Implementation)

  • 장원석;김대현;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3230-3232
    • /
    • 2000
  • DR (Digital Radiography) system will be the best candidate for next generation x-ray diagnosis system. DR system will replace x-ray film by computer monitor and provide various merits like reduced processing time, easy recording, remote diagnosis and etc. In this paper, we propose the pre-processing algorithm which is designed to compensate dead and defected pixel for x-ray detector panel. We also designed DSP(Digital Signal Processor) based DR image processing board for real-time processing of suggested algorithm.

  • PDF