• Title/Summary/Keyword: Digital health

Search Result 2,278, Processing Time 0.031 seconds

DR Image Enhancement Using Multiscale Non-Linear Gain Control For Laplacian Pyramid Transformation (라플라시안 피라미드에서의 다중스케일 비선형 이득 조절을 이용한 DR 영상 개선)

  • Shin, Dong-Kyu;Lee, Jin-Su;Kim, Sung-Hee;Park, In-Sung;Kim, Dong-Youn
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.199-204
    • /
    • 2007
  • In digital radiography, to improve the contrast of digital radiography image, the multi-scale nonlinear amplification algorithm based on unsharp masking is one of the major image enhancement algorithms. In this paper, we used the Laplacian pyramid to decompose a digital radiography(DR) image. In our simulation, the DR image was decomposed into seven layers and the coefficients of the each layer was amplified with nonlinear function. We also imported a noise containment algorithm to limit noise amplification. To enhance the contrast of image, we proposed a new adaptive non-linear gain amplification coefficients. As a result of having applied to some clinical data, a detail visibility was improved significantly without unacceptable noise boosting. Images that acquired with the proposed adaptive non-linear gain coefficients have shown superior quality to those that applied similar gain control method and expected to be accepted in the clinical applications.

Systematic Review of Extended Reality Digital Therapy for Enhancing Mental Health Among South Korean Adolescents and Young Adults

  • Serim Lee;Jiyoung Yoon;Yeonjee Cho;JongSerl Chun
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.34 no.4
    • /
    • pp.204-214
    • /
    • 2023
  • Digital therapy using extended reality (XR) holds great promise for addressing the mental health needs of adolescents and young adults. This study addresses a notable research gap in South Korea by systematically reviewing XR-based digital therapy for the mental health of South Korean adolescents and young adults. We analyzed 26 studies encompassing various aspects, including study type, publication date, research field, research methodology, data sources, program types, program content, sample characteristics, target population, assessment tools, and program effectiveness. Notably, 46.15% of the studies employed an experimental design, whereas over 53% utilized non-experimental approaches. Experimental studies lacked a genuine design, standardized questionnaires, and control variables. Similarly, non-experimental studies failed to report specific literature selection criteria. Consequently, future studies should adopt rigorous methodologies to enhance reliability and validity. Moreover, over 85% of the 26 studies focused solely on virtual reality and did not incorporate augmented or mixed reality. This study identifies the limitations of the previous research. These findings emphasize the need for structured investigations to advance the development of XR-based digital therapy to promote mental health in adolescents and young adults in South Korea.

Biometry of width between labial transitional line angles in anterior teeth: an observational study

  • Wen, Chao;Ye, Hongqiang;Chen, Hu;Zhou, Yongsheng;Huang, Mingming;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • PURPOSE. The maximum width between the mesial and distal labial transitional line angles, described as "esthetic width" herein, could significantly influence the visual perception of the teeth and smile. This study aimed to conduct biometric research on esthetic width and to explore whether regular distribution exists in the esthetic width of human teeth. MATERIALS AND METHODS. A total of 4,264 maxillary and mandibular anterior teeth were measured using the Geomagic studio software program. The proportions of maxillary to mandibular homonymous teeth and proportions between the adjacent teeth were calculated. Bilateral symmetry and the correlation between the esthetic and mesiodistal widths were both accounted for during the measurement procedures. RESULTS. The mean esthetic widths were 6.773 ± 0.518 mm and 4.329 ± 0.331 mm for maxillary and mandibular central incisors, respectively, 5.451 ± 0.487 mm and 5.008 ± 0.351 mm for maxillary and mandibular lateral incisors, respectively, and 3.340 ± 0.353 mm and 5.958 ± 0.415 mm for maxillary and mandibular canines, respectively. Except for the mandibular canines, no significant difference in esthetic width was found among homonymous teeth from the same jaw. A high linear correlation was found between the esthetic and mesiodistal widths of the same tooth, except for the maxillary canines. Esthetic width proportions among different tooth categories showed some regular patterns, which were similar to those of the mesiodistal width. CONCLUSION. Esthetic width is regularly distributed among the teeth in the Chinese population. This could provide an important reference for anterior dental restorations and dimension recovery in esthetic reconstruction of anterior teeth.

Exploring Barriers Affecting e-Health Service Continuance Intention in India: From the Innovation Resistance Theory Stance

  • Arghya Ray;Pradip Kumar Bala;Yogesh K. Dwivedi
    • Asia pacific journal of information systems
    • /
    • v.32 no.4
    • /
    • pp.890-915
    • /
    • 2022
  • Although existing studies on e-health have usually focused on e-health services adoption intention, there is a dearth of studies on the barriers that affect e-health services retention intention especially in India. Additionally, although studies have mostly focused on utilizing expectation-confirmation model to understand innovation related barriers, innovation resistance theory (IRT) has been overlooked. As Indian e-health service providers face stiff challenges due to customer's unwillingness to continue using the service, there is a need to bridge the research gap that exists in this context. This mixed-method study, based on responses received from 289 participants and 1154 online negative reviews from e-Health providers in India, examines the barriers from the IRT stance. Results of this study reveal a notable negative association between tradition, value and financial barrier and intention to continue using e-health services. Additionally, continuance intention affects recommendation. The study concludes with various implications and scope for future research.

Reliability, accuracy of evaluations obtained from CEREC$^{(R)}$ AC system digital impression: an in-vitro study (CEREC$^{(R)}$ AC system으로 채득된 디지털 인상의 재현성, 정확성 평가에 관한 연구)

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Hae-Young;Kim, Jung-Ae;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.121-128
    • /
    • 2012
  • Purpose: The aim of this study was to determine the reliability and accuracy of measurements in digital models(CEREC$^{(R)}$ AC) compared to stone models. Methods: A master model(500B-1, Nissin Dental Product, Japan) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CEREC$^{(R)}$ AC intra-oral scanner(n=10). One examiner measured two times the intercanine, intermolar distance, dental arch length. The stone model were measured using a digital caliper. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed very good reliability. At the intra-examiner reliability of measurement, ICC at the stone and CEREC$^{(R)}$ AC model were 0.81 and 0.94. The mean difference between measurements made directly on the stone models and those made on the CEREC$^{(R)}$ AC model was 0.20~0.28mm, and was statistically significant(P=0.001). Conclusion: These in vitro studies show that accuracy of the digital impression is similar to that of the conventional impression. These results will have to be confirmed in further clinical studies.

Reduction of Patient Dose Exposure and Improvement of Image Quality by Use of Additional Filtration in Digital Radiology (디지털 진단방사선촬영에서 부가여과판 사용에 따른 피폭선량 감소와 화질 개선)

  • Moon, Su-Jeong;Kim, Young-Keun;Lee, Seong-Kil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.19-25
    • /
    • 2010
  • This study is mainly for the reduction of exposure dose by using a heavy elements filter(Gd) in the digital radiology. They contained heavy elements filter of Gd and X-ray beam hardening filters such as Al and Cu. According to the results of experimental evaluation, X-ray property was not changed with variety of kVp in the case of the Gd filter. The surface dose and absorption dose were increased in order of Cu and Al. The contrast of image showed the higher value in order of Cu, Al and Gd. While the use of Gd has increased the numerical value of the CR image, and grayscale has decreased noise value of the DR image.

  • PDF

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

  • Jang, Yeon;Sim, Ji-Young;Park, Jong-Kyoung;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.367-373
    • /
    • 2018
  • PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (${\alpha}=.05$). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<$120{\mu}m$).

A Study on Application of Internet-based Personal Health Record(PHR) System: Using Google Health (인터넷기반의 개인전자건강기록 시스템 적용사례 연구: 구글헬스를 중심으로)

  • Jeong, Seong-Hee
    • Journal of Digital Contents Society
    • /
    • v.10 no.3
    • /
    • pp.433-439
    • /
    • 2009
  • With the help of fast growing popularization of internet, all areas of e-Health have expanded rapidly; such that people have become interested in digital personal health record and its management. This paper examined the characteristics of personal health record and made the analysis of the structure of Google Health, the internet-based personal health record system. Google Health allows you to store and manage all of your health information, import medical records from hospitals and pharmacies, share your health records, and explore online health services. This examples represents not only a significant change of current medical systems but also enables to estimate the future stream of it. As a result, this paper, in the areas of e-Health which will be expanded in various service areas, may give you a greater sense of importance of personal health record and will eventually provide more complemental structure of future personal health record through comparative studies on the strength and weakness of it.

  • PDF

Perceptions of dental hygienists toward digital dentistry (치과 디지털 활용에 관한 치과위생사의 인식)

  • Kim, Young-Sun;Park, Hyun-Suk;Ku, In Young
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.6
    • /
    • pp.909-916
    • /
    • 2013
  • Objectives : The purpose of this study was to investigate the perceptions of dental hygienists toward digital dentistry. Methods : The subjects were 393 dental hygienists in Daegu Gyeongbuk. A total of 380 data were analyzed except the incomplete questionnaires. Data were analyzed by descriptive statistics, chi-square test, t-test, one-way ANOVA using SPSS version 18.0. Results : 1. Difference of perception by general characteristics was affected by age, academic background, working career, and married. 2. Difference of perception by utilization of digital facilities was affected by digital camera, CAD/CAM system, oral scanner, and computer system. 3. Difference of perception by digital education experience and intention of participation was affected by stronger intention to participate in digital education and practical exercise. Digital X-ray system and CAD/CAM system were the must-be equipment in education. Conclusions : Utilization of digital dentistry is the motive for education experience in dental hygienists.