• Title/Summary/Keyword: Digital Wear

Search Result 165, Processing Time 0.022 seconds

A Needs Assessment of People with Hearing Impairment for Hearing Augmentation Technology Development: Focusing on Risk Context Awareness Communication (청각증강 기술 개발을 위한 청각장애인의 욕구조사: 위험상황 인식 및 의사소통 분야를 중심으로)

  • Lee, Jun Woo;Lee, Hyuna;Bach, Jong Mie
    • 재활복지
    • /
    • v.22 no.3
    • /
    • pp.225-257
    • /
    • 2018
  • The purpose of this study is to find the application point of hearing augmentation technology development through examining the risk context experience of people with hearing impairment and the use of assistive device used as an alternative technology. Data of 355 people with hearing impairment with official disability grading was analyzed. The results of this study are first, research participants had no experience of recognizing any sound or vibration in situations highest in the order of means of transportation, material, and nature. Especially the ratio of being unable to recognize the sound and vibration of means of transportation was high, which implies the high possibility of people with hearing impairment experiencing risk. Secondly, the risk context that people with hearing impairment will most likely to experience are highest in the order of traffic accident, pedestrian accident, and daily life at home. Thirdly, the recognition of 2G phone/smart phone, vibrating digital alarm clock, light bar, vibrating wrist watch as assistive device for risk context awareness and notification was high and the satisfaction level of 2G phone/smart phone was the highest. Fourthly, the research participants had high recognition of assistive device for communication in the order of hearing aid, smart phone, videophone, cochlear implant and 2G phone and it was found that the satisfaction level and communication improvement level was the highest using the smart phone. Lastly, for the development of hearing augmentation technology the research participants recognized the importance of portable/wear convenience, price, and motion accuracy and for notification delivery means they preferred the method of using sight(text and light). Based on the results of this study policy and practical plans for hearing augmentation technology development for people with hearing impairment in risk context are proposed.

Computer-aided design and manufacturing-based full mouth rehabilitation for a patient with excessive attrition and restricted vertical dimension: A case report (심한 치아 마모와 수복 공간 부족을 보이는 환자에서 CAD/CAM 기술을 활용한 완전 구강 회복: 증례 보고)

  • Cho, Jun-Ho;Yoon, Hyung-In;Yeo, In-Sung;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.495-505
    • /
    • 2019
  • This study reported the treatment of a patient with excessive worn dentition and limited maxillo-mandibular space for restoration, utilizing the computer-aided design and computer-aided manufacturing (CAD/CAM) technology. After the thorough examination of the patient's occlusal vertical dimension (OVD), full mouth rehabilitation was planned with increase of the OVD. The patient was satisfied with the provisional restorations establishing the increased OVD. The horizontal and vertical data of the patient's jaw relation that the provisional restorations contained were transferred to the definitive metal ceramic fixed prostheses by double scanning and three-dimensional printing. After the fixed restorations were cemented to the abutments, electronic surveying and three-dimensional printing were used to fabricate metal frameworks for the patient's removable partial dentures. The mandibular definitive removable prostheses were delivered to the patient's mouth and the full mouth rehabilitation procedures were completed. The digital technologies used for this case produced fixed and removable restorations satisfactory in masticatory, phonetic and aesthetic functions to both the patient and the dental clinician.

Fit Tests for Second-class Half Masks (2급 방진마스크 밀착도 평가)

  • Cho, Kee Hong;Kim, Hyun Soo;Choi, Ah Rum;Chun, Ji Young;Kang, Tae Won;Kim, Min Su;Park, Kyeong Hak;Kim, Ze One
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.146-152
    • /
    • 2022
  • Objectives: The purpose of this study is to confirm whether there is a factor to affect the evaluation of fit test of a 2nd class half masks using a OPC test method. Methods: Total 34 adults including Males and Females were tested using OPC-based fit testing equipment while wearing a 2nd class half filtered mask. Results: 1. The result of measuring face dimensions using different tools such as a 3D scanner and digital calipers revealed that the variation of lip width was not statistically significant because there was only a difference of about 4 mm. However, it showed that a difference in face length was statistically significant enough with 10 mm(p<0.000). 2. The fit factor for each exercise stage according to gender was the highest at 124.54(p<0.001) in Step 3, and the fit factor was the lowest at 73.75 in Step 1. 3. In the evaluation of the degree of fit factor according to gender, female passed 67.44%, which was higher than the value in male(p<0.038). 4. The acceptance rate of the group having a face length of shorter than 110 mm was 91.67%. On the other hand, the acceptance rate of the group with a face length of longer than 110 mm was 47.27%(p<0.000). 5. The fit test was possible because the fit factor with 2nd class half masks corresponding to FFP1(Filtering Face Piece 1) was passed 55% or more. Conclusions: The test results showed that using a 2nd class half filtered mask, it is important to wear a properly designed mask so that face size does not affect the fit factor.

A study on the asperity degradation of rock joint surfaces using rock-like material specimens (유사 암석 시편을 사용한 암석 절리면 돌출부 손상 연구)

  • Hong, Eun-Soo;Kwon, Tae-Hyuk;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.3
    • /
    • pp.303-314
    • /
    • 2009
  • Image analyses for sheared joint specimens are performed to study asperity degradation characteristics with respect to the roughness mobilization of rock joints. Four different types of joint specimens, which are made of high-strength gypsum materials, are prepared by replicating the three-dimensional roughness of rock joints. About twenty jointed rock shear tests are performed at various normal stress levels. The characteristic and scale of asperity degradation on the sheared joint specimens are analyzed using the digital image analysis technique. The results show that the asperity degradation characteristic mainly depends on the normal stress level and can be defined by asperity failure and wear. The asperity degradation develops significantly around the peak shear displacement and the average amount of degraded asperities remains constant with further displacement because of new degradation of small scale asperities. The shear strength results using high-strength gypsum materials can not fully represent physical properties of each mineral particles of asperities on the natural rock joint surface. However the results of this quantitative estimation for the relationship between the peak shear displacement and the asperity degradation suggest that the characterization of asperity degradation provides an important insight into mechanical characteristics and shear models of rock joints.

Prosthetic rehabilitation in a Class III malocclusion patient with increasing occlusal vertical dimension (3급 부정교합 환자의 교합수직고경 증가를 동반한 보철 수복)

  • Ha-Eun Choi;Han-Sol Song;Kyung-Ho Ko;Yoon-Hyuk Huh;Chan-Jin Park;Lee-Ra Cho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.133-145
    • /
    • 2023
  • Class III malocclusion with mandibular protrusion can be divided into skeletal and pseudo malocclusion due to tooth displacement. For skeletal malocclusion, favorable treatment results can be obtained by establishing an appropriate vertical and horizontal intermaxillary relationship in order to secure a restoration space and obtain aesthetic and functional results. In this case, complete mouth rehabilitation was performed using an implant and a fixed prosthesis in a patient with mandibular protrusion and anterior teeth wear and reduced occlusal vertical dimension. After cast analysis and digital diagnosis, a provisional restoration with increased vertical dimension was fabricated to secure posterior support and evaluate stable centric occlusion. With the definitive prosthesis reflecting the provisional restoration, favorable function and aesthetics were obtained.