• Title/Summary/Keyword: Digital Radiography

Search Result 488, Processing Time 0.032 seconds

Evaluation of dental panoramic radiographic findings in edentulous jaws: A retrospective study of 743 patients "Radiographic features in edentulous jaws"

  • Kose, Taha Emre;Demirtas, Nihat;Karabas, Hulya Cakir;Ozcan, Ilknur
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.380-385
    • /
    • 2015
  • PURPOSE. The aim of this study was to determine the frequency of significant panoramic radiographic findings and eventual treatment requirements before conventional or implant supported prosthetic treatment in asymptomatic edentulous patients. MATERIALS AND METHODS. A total of 743 asymptomatic edentulous patients were retrospectively evaluated using a digital panoramic system. We analyzed the radiographic findings, including impacted teeth, retained root fragments, foreign bodies, severe atrophy of the posterior maxillary alveolar bone, mucous retention cysts, soft tissue calcifications and radiopaque-radiolucent conditions. RESULTS. Four-hundred-eighty-seven (65.6%) patients had no radiographic finding. A total of 331 radiographic findings were detected in 256 (34%) patients. In 52.9% (n=175) of these conditions, surgical treatment was required before application of implant-supported fixed prosthesis. However, before application of conventional removable prosthesis surgical treatment was required for 6% (n=20) of these conditions. CONCLUSION. The edentulous patients who will have implant placement for implant-supported fixed prosthesis can frequently require additional surgical procedures to eliminate pathological conditions.

Current status of dental intraoral imaging devices and radiographic safety management (치과 구내촬영 장비 현황과 방사선 안전 관리 실태 연구)

  • Kang, Eun-Ju;Hyeong, Ju-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.205-214
    • /
    • 2016
  • Objectives: The purpose of the study is to investigate the current status and radiographic safety management in Korea. Methods: A self-reported questionnaire was completed by 200 dental hygienists in Jeonbuk province from September 1, 2014 and October 31, 2014. The questionnaire consisted of general characteristics of the subjects, radiation knowledge, radiation safety management, and radiation exposure anxiety. Data were analyzed using SPSS 18.0 program. Results: Duration of clinical experience(r=0.142) and number of daily radiation shot(r=0.145) showed a positive correlation to radiation safety management, and a nrgative correlation to use of intraoral films and digital devices(r=-0.587). A logistic regression analysis was performed in order to evaluate the influence on radiography knowledge. The results showed that the factors had significant influences on the age group over 41 years old(OR 7.25; 95% CI 1.30-40.43) and those who took a position above team leader(OR 0.23; 95% CI 0.59-0.90). Conclusions: It is very important to have the safety management toward dental intraoral imaging and radiograpgic shot in the dental hygienists. Continuous efforts should be emphasized on radiographic safety management and behavior.

A Study of Real Time Verification System or Radiation Therapy (방사선치료 위치 실시간 검증시스템에 관한 연구)

  • Kim, Y.J.;Ji, Y.H.;Lee, D.H.;Lee, D.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.164-167
    • /
    • 1997
  • The treatment setup of patients during irradiation is an important aspect in relation to the success of radiotherapy. Imaging with the treatment beam is a widely used method or verification of the radiation field position relative to the target area, prior to or during irradiation. In this paper, Real time digital radiography system was implemented or verification of local error between simulation plan and radiation therapy machine. Portal image can be acquired by CCD camera, image board and pentium PC after therapy Radiation was converted into light by a metal/fluorescent Screen. The resulting image quality is comparable to film, so the imaging system represents a promising alternative to film as a method of verifying patient positioning in radiotherapy. Edge detection and field size measurement were also implemented and detected automatically for verification of treatment position. Field edge was added to the original image or checking the anatomical treatment verification by therapy technicians. By means of therapy efficiency improvement and decrease of Radiation side effects with these techniques, Exact Radiation treatments are expected.

  • PDF

A Ring Artifact Correction Method for a Flat-panel Detector Based Micro-CT System (평판 디텍터 기반 마이크로 CT시스템을 위한 Ring Artifact 보정 방법)

  • Kim, Gyu-Won;Lee, Soo-Yeol;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.476-481
    • /
    • 2009
  • The most troublesome artifacts in micro computed tomography (micro-CT) are ring artifacts. The ring artifacts are caused by non-uniform sensitivity and defective pixels of the x-ray detector. These ring artifacts seriously degrade the quality of CT images. In flat-panel detector based micro-CT systems, the ring artifacts are hardly removed by conventional correction methods of digital radiography, because very small difference of detector pixel signals may make severe ring artifacts. This paper presents a novel method to remove ring artifacts in flat-panel detector based micro-CT systems. First, the bad lines of a sinogram which are caused by defective pixels of the detector are identified, and then, they are corrected using a cubic spline interpolation technique. Finally, a ring artifacts free image is reconstructed from the corrected projections. We applied the method to various kinds of objects and found that the image qualities were much improved.

Speech Outcome and Timing of Furlow Palatoplasty in Cleft Palate (Furlow 구개성형술을 시행한 구개열에서 언어발달과 적절한 수술시기)

  • Jin, Ung Sik;Kim, Suk Wha;Lee, Soung Joo
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.67-74
    • /
    • 2006
  • Palatoplasty using Furlow's double-opposing Z-plasty has been performed from June, 1995 to September, 1999 at Seoul National University Children's Hospital. The goal of this study is to determine the optimal timing of repair and cleft severity affecting velopharyngeal function. This is the retrospective study of patients operated by the second author. The mean age of patients was 10.53 months. The patients could be divided into three groups-isolated cleft palate(n=70), unilateral cleft lip and palate(n=88), and bilateral cleft lip and palate(n=42). To evaluate the velopharyngeal function, we used two parameters, speech evaluation and cineofluorography using DSR(digital subtraction radiography). Also, to determine the relevance between cleft severity and speech development, we measured the distance between maxillary tuberosities and cleft margins. Among 200 patients, about 96% had no or minimal hypernasality and 87% had no or mild nasal emission. The cleft width and length of soft palate seemed not to be related with the speech development. Palatoplasty at the age under 12 months resulted in less 'nasal emission' and better 'articulation' of the parameters that were assessed at the age of 7 years. It can be concluded Furlow palatoplasty shows satisfactory results and also it seems that it is better to perform the operation before the age of 12 months.

A comparison of density of Insight and Ektaspeed plus dental x-ray films using automatic and manual processing (자동 및 수동현상에 따른 Insight 필름과 Ektaspeed Plus 필름의 흑화도 비교)

  • Yoon Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.17-22
    • /
    • 2001
  • Purpose: To compare the film density of Insight dental X-ray film (Eastman Kodak Co., Rochester, NY, USA) with that of Ektaspeed Plus film (Eastman Kodak) under manual and automatic processing conditions. Materials and Methods : Insight and Ektaspeed Plus films were exposed at three different exposure conditions with an aluminum step wedge on the films under the three different exposure times. The exposed films were processed by both manual and automatic ways. The Base plus fog density and the optical density made by exposing step wedge were calculated using a digital densitometer (model 07-443, Victoreen Inc, Cleveland, Ohio, USA). The optical densities of the Insight and Ektaspeed film versus thickness of alumimun wedge at the same exposure time were plotted on the graphs. Statistical analyses were applied for comparing the optical densities of the two films. Results: The film density of both Insight films and Ektaspeed Plus films under automatic processing condition was significantly higher over the manual processing. The film density of Insight films was significantly higher than that of Ektaspeed Plus films on both automatic and manual processing conditions. Conclusion: The radiation exposure time can be reduced when using Insight over Ektaspeed Plus film. To take the full advantage of reducing exposure time, Insight film should be processed automatically.

  • PDF

Transport Properties of Conversion Materials for Digital Radiography

  • Kim, Jae-Hyung;Park, Chang-Hee;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.250-254
    • /
    • 2007
  • Applying the moving photo-carrier grating(MPG) technique and time-of-flight(TOF) measurements, we studied the transport properties of stabilized amorphous selenium typical of the material used in direct conversion X-ray imaging devices. For MPG measurement, we obtained electron and hole mobility and the recombination lifetime of $\alpha-Se$ films with arsenic(As) additions. We found an apparent increase in hole drift mobility and recombination lifetime, especially when 0.3 % As was added into $\alpha-Se$ film, whereas electron mobility decreased with the addition of As due to the defect density. For TOF measurement, a laser beam with pulse duration of 5 ns and wavelength of 350 nm was illuminated on the surface of $\alpha-Se$ with a thickness of 400 ${\mu}m$. The measured hole and electron transit times were about 8.73 ${\mu}s$ and 229.17 ${\mu}s$, respectively.

Adaptive image enhancement technique considering visual perception property in digital chest radiography (시각특성을 고려한 디지털 흉부 X-선 영상의 적응적 향상기법)

  • 김종효;이충웅;민병구;한만청
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.8
    • /
    • pp.160-171
    • /
    • 1994
  • The wide dynamic range and severely attenuated contrast in mediastinal area appearing in typical chest radiographs have often caused difficulties in effective visualization and diagnosis of lung diseases. This paper proposes a new adaptive image enhancement technique which potentially solves this problem and there by improves observer performance through image processing. In the proposed method image processing is applied to the chest radiograph with different processing parameters for the lung field and mediastinum adaptively since there are much differences in anatomical and imaging properties between these two regions. To achieve this the chest radiograph is divided into the lung and mediastinum by gray level thresholding using the cumulative histogram and the dynamic range compression and local contrast enhancement are carried out selectively in the mediastinal region. Thereafter a gray scale transformation is performed considering the JND(just noticeable difference) characteristic for effective image displa. The processed images showed apparenty improved contrast in mediastinum and maintained moderate brightness in the lung field. No artifact could be observed. In the visibility evaluation experiment with 5 radiologists the processed images with better visibility was observed for the 5 important anatomical structures in the thorax.

  • PDF

Investigation of Geometrical Properties on Deposition Rate in Cesium Iodine Film (증착속도에 따른 CSI layer의 기하학적 특성 연구)

  • Lee, Kyu-Hong;Park, Ji-Koon;Kang, Sang-Sik;Cha, Byung-Yul;Cho, Sung-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.415-417
    • /
    • 2003
  • CsI 형광체는 X선에 대한 분해능 및 변환효율이 우수한 물질이다. 최근 대면적 평판형 X선 영상검출기의 변환층으로 이용하기 위해 CsI 형광체의 대면적 제조에 대한 연구가 활발히 진행되고 있다. 본 논문은 진공 열증착법을 이용하여 증착속도(3, 3.8, $4.5\;{\mu}m/min$)에 따라 $20\;{\mu}m$ 두께의 CsI 필름을 제조하였고, XRD 및 SEM 분석을 통해 CsI 필름의 기하학적 구조를 조사하였다. 증착된 CsI 필름은 증착속도에 관계없이 복잡한 다결정 구조를 가지며, $3\;{\mu}m/min$의 증착속도에서 약 $1\;{\mu}m$ 크기로 needle-like 한 columnar structure를 가졌다. As results, about 3um/min evaporation rate formed as good geometry characteristics CsI layer.

  • PDF

Correlation between Vertebral Left Atrial Size and NT-proBNP in Dogs with Myxomatous Mitral Valve Disease

  • Chae, Dong-Jin;Han, Sung-Hyun;Song, Kunho
    • Journal of Veterinary Clinics
    • /
    • v.38 no.5
    • /
    • pp.215-220
    • /
    • 2021
  • The purpose of this study was to investigate the correlation between vertebral left atrial size (VLAS) and NT-proBNP levels. Sixty-three dogs with myxomatous mitral valve disease (MMVD) were recruited for this study. The MMVD group was classified according to the ACVIM stage based on medical history, clinical signs, and thoracic radiography and echocardiography findings. The N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels were measured using fluorescent immunoassay. VLAS and VHS values were measured using a digital caliper in the right lateral view. There were significant differences in VLAS for each American college of veterinary internal medicine (ACVIM) stage (p < 0.01). As the ACVIM stage increased, it tended to increase. Vertebral heart score (VHS) also showed a tendency to increase with the ACVIM stage (p < 0.01). VLAS was divided into three groups: VLAS <2.6, 2.6≤ VLAS <3.1, and VLAS ≥3.1. NT-proBNP values were significantly different between the three groups (p < 0.01), and VLAS and NT-proBNP values showed a strong positive correlation (r = 0.756, p < 0.01). In conclusion, there were significant differences among ACVIM stages B1 and B2, B1 and C-D, and B2 and C-D groups regarding VLAS. Furthermore, NT-proBNP increased proportionally as VLAS increased. Measurements of VLAS may be helpful in the diagnosis of MMVD in addition to the existing radiological and echocardiographic methods.