• Title/Summary/Keyword: Digital Hospital

Search Result 1,339, Processing Time 0.025 seconds

Comparison and consideration of general hospital with small-medium hospital PACS system problem (종합병원과 중$\cdot$소병원 방사선과의 PACS system 비교와 발생하는 문제점에 대한 고찰)

  • Kim Hyun;Cho Jongmin;Hwang Sangsu
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.222-228
    • /
    • 2001
  • Ⅰ. Purpose : The development of new imaging techniques and the increasing proportion of medical imaging modalities that generate images in digital form has naturally lead to the development of digital image management systems. Many people would agree that

  • PDF

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.

Digital-hospital Research on the Factors that Lead to the Success of the Overseas-hospital Export Business through an Analysis of the Bidding Documents (해외병원 입찰분석을 통한 디지털병원 수출사업 성공요인)

  • Cha, Maengkyu;Kim, Jung Ok;Yu, Kiyun
    • KIISE Transactions on Computing Practices
    • /
    • v.23 no.6
    • /
    • pp.359-370
    • /
    • 2017
  • In overseas-hospital construction, the digital hospital is a trend that is based on the developments of the information and communication technologies, state-of-the-art medical equipment, smart health, and telemedicine. Along with the increasing proportion of IT, this has resulted in the spreading of the concept throughout city-like hospitals and their transformation into digital hospitals. In the hospital-construction business, IT is a key element that will link the modernization of the mechanical, electrical, and equipment systems, construction, and medical equipment for efficiency maximization through integration. The purpose of this study is the analysis of the market-expansion success factors through the construction of a success-story-based, IT-driven overseas-hospital business. The digital-hospital concept and the development process are analyzed through a literature review, and the success factors are analyzed in terms of the cost, time, and quality that are proposed in the project-management body of knowledge. The main contributions of this study regarding the success factors are as follows: First, a cost-side need exists regarding the establishment of strategic-value engineering in terms of increasing the value from the perspectives of the IT and operational infrastructures; second, in terms of the construction time, all of the hospital systems must comply with the established deadlines for the integrated test and commissioning; and lastly, in terms of quality, it is important to ensure that the System Integration digital-hospital services are delivered according to the user requirements.

Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report (구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례)

  • Chang, Yun-Jeong;Kim, Hong-Jun;Song, Mi-Kyoung;Moon, Ji-Eun;Lee, Hal-La;Park, Chan-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.234-243
    • /
    • 2015
  • Developing of digital technique, it is possible to fabricate implant prostheses for edentulous area using intraoral 3-dimentional information throughout implant diagnosis and treatment process. It is being changed that from the method using CAD/CAM, producing prostheses by model scanning after conventional impression and model processing, to the method of fabricating implant provisional restorations and customized abutments by digital impression after connecting digital impression copings (scanbody) and implant fixtures without models. But, this digital method has not been actively used for implant prostheses not yet. Specially, it is short of intraoral digital impression cases for immediate provisional restorations of the maxillary anterior implants. The gingival contour impression of maxillary anterior area is very important for esthetic restorations. Accordingly, in this case report, the using a digital impression coping (scanbody) and digital impression by CEREC Omnicam (Sirona, Bensheim, Germany) or Trios (3shape, Copenhagen, Denmark) were introduced for immediate provisional restorations in 3 cases needed a single implant restoration in maxillary anterior area. The clinical results were satisfactory on the convenience and accuracy of digital impression technique and the good esthetics of final restorations.

Validation of the mobile wireless digital automatic blood pressure monitor using the cuff pressure oscillometric method, for clinical use and self-management, according to international protocols

  • Yoo, Sooyoung;Baek, Hyunyoung;Doh, Kibbeum;Jeong, Jiyeoun;Ahn, Soyeon;Oh, Il-Young;Kim, Kidong
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.399-404
    • /
    • 2018
  • The purpose of this study was to evaluate the accuracy of a mobile wireless digital automatic blood pressure monitor for clinical use and mobile health (mHealth). In this study, a manual sphygmomanometer and a digital blood pressure monitor were tested in 100 participants in a repetitive and sequential manner to measure blood pressure. The guidelines for measurement used the Korea Food & Drug Administration protocol, which reflects international standards, such as the American National Standard Institution/Association for the Advancement of Medical Instrumentation SP 10: 1992 and the British Hypertension Society protocol. Measurements were generally consistent across observers according to the measured mean ${\pm}SD$, which ranged in $0.1{\pm}2.6mmHg$ for systolic blood pressure (SBP) and $0.5{\pm}2.2mmHg$ for diastolic blood pressure (DBP). For the device and the observer, the difference in average blood pressure (mean${\pm}$SD) was $2.3{\pm}4.7mmHg$ for SBP and $2.0{\pm}4.2mmHg$ for DBP. The SBP and DBP measured in this study showed accurate measurements that satisfied all criteria, including an average difference that did not exceed 5 mmHg and a standard deviation that did not exceed 8 mmHg. The mobile wireless digital blood pressure monitor has the potential for clinical use and managing one's own health.

Methods of DICOM and Non-DICOM Interfacing for various Radiological Equipments with PACS (방사선 검사 관련 의료장비와 PACS 간의 연동을 위한 DICOM 및 Non-DICOM 인터페이스 방안)

  • Kim, H.C.
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.6 no.1
    • /
    • pp.51-64
    • /
    • 2003
  • This thesis describes the effective interfacing methods of PACS Modality based on the system installation andoperating experiences. PACS(Picture Archiving and Communication Systems) is a system for medical image archiving and communication using large storage device and high-speed network. The standard communication protocol of PACS is DICOM(Digital Imaging and Communication in Medicine) based on TCP/IP and point-to-point protocol. However, there are many Non-DICOM Modalities and DICOM Modalities having problems. First, we had interfaced almost modalities. Fuji CR, GE CT, MRI, Angio, Fluoro, Phillips Angio, Shimadzu Fluoro. Ultrasound PACS, with the main PACS in the Seoul S Hospital as large scale hospital. And we manipulated the intelligent image distribution and the CT. MRI Interfaces never experienced beforein the Anyang J Hospital and the Chungju C Hospital as mid or small scale hospital. Technically, we developed both the DICOM Interface and the Non-DICOM Interface. At the last, the DICOM Worklist and the DICOM Print Interface were implemented in the Seoul B Hospital, the Bucheon SJ Hospital and the Seoul K Hospital independently with PACS. The Oracle, Sybase and MS-SQL are used as database, and UNIX, Macintosh, MS Windows as operating systems. And the Visual C++ and UNIX C are the main programming tools. We have used UTP, coaxial and fiber optic cable under 10/100 mbps LAN for networking.

  • PDF

Methods of DICOM and Non-DICOM Interfacing for various Radiological Equipments with PACS (방사선 검사 관련 의료장비와 PACS 간의 연동을 위한 DICOM 및 Non-DICOM 인터페이스 방안)

  • Kim, Hyeon-Cheol
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.46-63
    • /
    • 2002
  • This thesis describes the effective interfacing methods of PACS Modality based on the system installation and operating experiences. PACS(Picture Archiving and Communication Systems) is a system for medical image archiving and communication using large storage device and high-speed network. The standard communication protocol of PACS is DICOM(Digital Imaging and Communication in Medicine) based on TCP/IP and point-to-point protocol. However, there are many Non-DICOM Modalities and DICOM Modalities having problems. First, we had interfaced almost modalities, Fuji CR, GE CT, MRI, Angio, Fluoro, Phillips Angio, Shimadzu Fluoro, Ultrasound PACS, with the main PACS in the Seoul S Hospital as large scale hospital. And we manipulated the intelligent image distribution and the CT, MRI Interfaces never experienced before in the Anyang J Hospital and the Chungju C Hospital as mid or small scale hospital. Technically, we developed both the DICOM Interface and the Non-DICOM Interface. At the last, the DICOM Worklist and the DICOM Print Interface were implemented in the Seoul B Hospital, the Bucheon SJ Hospital and the Seoul K Hospital independently with PACS. The Oracle, Sybase and MS-SQL are used as database, and UNIX, Macintosh, MS Windows as operating systems. And the Visual C++ and UNIX C are the main programming tools. We have used UTP, coaxial and fiber optic Gable under 10/100 mbps LAN for networking.

  • PDF

Considerations on Standardization in Smart Hospitals

  • Sun-Ju Ahn;Sungin Lee;Chi Hye Park;Da Yeon Kwon;Sooyeon Jeon;Han Byeol Lee;Sang Rok Oh
    • Health Policy and Management
    • /
    • v.34 no.1
    • /
    • pp.4-16
    • /
    • 2024
  • Smart hospitals involve the use of recent ICT (information and communications technology) technologies to improve healthcare access, efficiency, and effectiveness. Standardization in smart hospital technologies is crucial for interoperability, scalability, policy formulation, quality control, and maintenance. This study reviewed relevant international standards for smart hospitals and the organizations that develop them. Specific attention was paid to robotics in smart hospitals and the potential for standardization in this area. The study used online resources and existing standards to analyze technologies, standards, and practices in smart hospitals. Key technologies of smart hospitals were identified. Relevant standards from ISO (International Organization for Standardization) and IEC (International Electrotechnical Commission) were mapped to each core technology. Korea's leadership in smart hospital technology were highlighted. Approaches for standardizing smart hospitals were proposed. Finally, potential new international standard items for robotics in smart hospitals were identified and categorized by function: sampling, remote operation, delivery, disinfection, and movement tracking/contact tracing. Standardization in smart hospital technologies is crucial for ensuring interoperability, scalability, ethical use of artificial intelligence, and quality control. Implementing international standards in smart hospitals is expected to benefit individuals, healthcare institutions, nations, and industry by improving healthcare access, quality, and competitiveness.

Anatomic Variation of the Common Palmar Digital Nerves and Arteries

  • Tian, Dong;Fu, Maoyong
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.3
    • /
    • pp.219-220
    • /
    • 2015
  • Variations in the course and distribution of common palmar digital nerves and arteries are rare. A classic common palmar digital nerves and arteries are defined as concomitant. During routine dissection classes to undergraduate medical students we observed formation of each common palmar digital nerve divided into 2 or 3 branches and formed a ring enclosing the corresponding common palmar digital artery. Knowledge of the anatomical variations of the common palmar digital nerves and arteries is crucial for safe and successful hand surgery.