• Title/Summary/Keyword: Digital Hospital

Search Result 1,338, Processing Time 0.028 seconds

Accuracy of three-dimensional periodontal ligament models generated using cone-beam computed tomography at different resolutions for the assessment of periodontal bone loss

  • Hangmiao Lyu;Li Xu;Huimin Ma;Jianxia Hou;Xiaoxia Wang;Yong Wang;Yijiao Zhao;Weiran Li;Xiaotong Li
    • The korean journal of orthodontics
    • /
    • v.53 no.2
    • /
    • pp.77-88
    • /
    • 2023
  • Objective: To develop a method for generating three-dimensional (3D) digital models of the periodontal ligament (PDL) using 3D cone-beam computed tomography (CBCT) reconstruction and to evaluate the accuracy and agreement of the 3D PDL models in the measurement of periodontal bone loss. Methods: CBCT data collected from four patients with skeletal Class III malocclusion prior to periodontal surgery were reconstructed at three voxel sizes (0.2 mm, 0.25 mm, and 0.3 mm), and 3D tooth and alveolar bone models were generated to obtain digital PDL models for the maxillary and mandibular anterior teeth. Linear measurements of the alveolar bone crest obtained during periodontal surgery were compared with the digital measurements for assessment of the accuracy of the digital models. The agreement and reliability of the digital PDL models were analyzed using intra- and interexaminer correlation coefficients and Bland-Altman plots. Results: Digital models of the maxillary and mandibular anterior teeth, PDL, and alveolar bone of the four patients were successfully established. Relative to the intraoperative measurements, linear measurements obtained from the 3D digital models were accurate, and there were no significant differences among different voxel sizes at different sites. High diagnostic coincidence rates were found for the maxillary anterior teeth. The digital models showed high intra- and interexaminer agreement. Conclusions: Digital PDL models generated by 3D CBCT reconstruction can provide accurate and useful information regarding the alveolar crest morphology and facilitate reproducible measurements. This could assist clinicians in the evaluation of periodontal prognosis and establishment of an appropriate orthodontic treatment plan.

A Study on the Design by using Digital Media of the General Hospital (디지털 미디어를 이용한 종합병원 디자인에 관한 연구)

  • Kim, Khil-Chae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.13 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • The purpose of this study is to suggest the design by using digital media the general hospital. The important result and advantage of the study are as follows; At first, applicability and maintenance of form and function design are enhanced and the digital media could be used for development of better and economical design. Secondly, the 3D CAD system useful for communication media and instructional tool for hospital planners and designers. Thirdly, fast and economical evaluation are obtained through the study of experimental simulation. Finally as a new tool in architectural field, the system helps to enhance the relationship between digital media and human. New concept and tools of hospital design are being developed in terms of its function, environment, and psychology. The computational design system should be improved for user friendly in the future.

  • PDF

A Study on the Architectural Planning of the Spaces Related With Digital Network System in General Hospital (병원 정보화 관련 실(室) 계획에 대한 연구)

  • Lim, Sung-Jae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.6 no.11
    • /
    • pp.107-116
    • /
    • 2000
  • The digital network system is one of the most important features in the resent hospital buildings. This study is to lay out a guideline of architectural planning according to the hospitals with digital network system. First, this study develops the concept of hospital building digital network system and reports the survey results of domestic general hospitals for this matter. Required spaces by digital network system in general hospital are classified into two categories. One is equipment room, main equipment room and a telecommunication closet, to accommodate network facilities. The other is the spaces related with medical information, medical archives and the department of radiology, because digital network system makes a change the form and use of information. In result, this study proposes models for each equipment room and raises the possibility of size change of information-spaces.

  • PDF

Analysis of the Status and Future Direction for Digital Therapeutics in Children and Adolescent Psychiatry

  • Haemi Choi;Bora Kim;Insoo Kim;Jae-Gu Kang;Yoonjae Lee;Hyowon Lee;Min-Hyeon Park
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.34 no.4
    • /
    • pp.192-203
    • /
    • 2023
  • Digital therapeutics based on software, such as artificial intelligence, virtual reality, games, and smartphone applications, are in the spotlight as new therapeutic alternatives in child and adolescent psychiatry. It draws attention to overcoming conventional therapeutics' limitations, such as toxicity, cost, and accessibility, and encourages patients to participate in the treatment attractively. The growth potential of the digital therapeutics market for psychiatric disorders in children and adolescents in Korea and abroad has been highlighted. Clinical studies and Food and Drug Administration approvals for digital therapeutics have increased, and cases approved by the Ministry of Food and Drug Safety have emerged in Korea. As seen above, digital transformation in child and adolescent psychiatry will change treatment paradigms significantly. Therefore, as this new field has just begun to emerge, it is necessary to verify the effectiveness and scope of the application of digital therapeutics and consider preparing a compensation system and institutional arrangements. Accordingly, this study analyzed the development trends and application status of digital therapeutics in children and adolescents and presented limitations and development directions from the perspective of application in healthcare. Further, the study is expected to identify the utility and limitations of digital therapeutics for children and adolescents and establish effective application measures.

Biometry of width between labial transitional line angles in anterior teeth: an observational study

  • Wen, Chao;Ye, Hongqiang;Chen, Hu;Zhou, Yongsheng;Huang, Mingming;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • PURPOSE. The maximum width between the mesial and distal labial transitional line angles, described as "esthetic width" herein, could significantly influence the visual perception of the teeth and smile. This study aimed to conduct biometric research on esthetic width and to explore whether regular distribution exists in the esthetic width of human teeth. MATERIALS AND METHODS. A total of 4,264 maxillary and mandibular anterior teeth were measured using the Geomagic studio software program. The proportions of maxillary to mandibular homonymous teeth and proportions between the adjacent teeth were calculated. Bilateral symmetry and the correlation between the esthetic and mesiodistal widths were both accounted for during the measurement procedures. RESULTS. The mean esthetic widths were 6.773 ± 0.518 mm and 4.329 ± 0.331 mm for maxillary and mandibular central incisors, respectively, 5.451 ± 0.487 mm and 5.008 ± 0.351 mm for maxillary and mandibular lateral incisors, respectively, and 3.340 ± 0.353 mm and 5.958 ± 0.415 mm for maxillary and mandibular canines, respectively. Except for the mandibular canines, no significant difference in esthetic width was found among homonymous teeth from the same jaw. A high linear correlation was found between the esthetic and mesiodistal widths of the same tooth, except for the maxillary canines. Esthetic width proportions among different tooth categories showed some regular patterns, which were similar to those of the mesiodistal width. CONCLUSION. Esthetic width is regularly distributed among the teeth in the Chinese population. This could provide an important reference for anterior dental restorations and dimension recovery in esthetic reconstruction of anterior teeth.

A Study on the Improvement Effect of Hospital Digital Signage for Room Spaces - Applying the Evidence-Based Design(EBD) Process (병원 진료 안내 디지털 사이니지 개선 효과 연구- 근거기반디자인(EBD) 과정을 적용하여)

  • Kwon, Youngmi;Lee, Seungji
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2023
  • Purpose: Evidence-based design is the process of making design decisions based on reliable research to achieve the best results, so it is important to accumulate reliable evidence through research. Therefore, the purpose of this study is to present new evidence by applying the evidence-based design process to improve the digital signage for each room spaces in hospitals and verifying its effectiveness. Method: Through the 8-step process of evidence-based design, improved digital signage for each room spaces are installed. It conducted surveys and statistical analysis to prove hypotheses by linking design and research. Results: The hypotheses established in the study are: 1) improvement in the readability of digital signage is correlated with patient satisfaction; 2) Improving the intuitiveness of digital signage correlates with patient satisfaction; 3) Improving the sufficiency of digital signage correlates with patient satisfaction. As a result of satisfaction analysis and correlation analysis, all of the above hypotheses were proven. Implications: Although the hospital sign system is the element that patients rely on most intuitively in the long journey of reception, waiting, examination, and treatment, there is insufficient evidence to refer to or apply it when designing. It is necessary to expand future research to expand the evidence that can be applied to hospital sign design.

The Comparison of Image Quality between Computed Radiography(CR) and Direct Digital Radiography(DDR) which Follows the Proper Exposure Conditions in General Photographing under the Digital Radiography (Digital Radiography 환경하에서 일반촬영시 적정노출조건에 따른 CR과 DDR의 Image Quality 비교)

  • Kim Jin Bae;Kang Chung Hwan;Kang Sung Jin;Park Soo In;Park Jong Won;Kim Yeong Su
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.22-34
    • /
    • 2001
  • DR은 방사선과 뿐만 아니라 병원전체의 생산성 및 업무의 효율성에서 중요한 요소로 자리잡아가고 있다. DR환경은 CR보다 다양한 Parameter를 가지고 있어 양질의 의료서비스 제공이 가능하다. 현재 각 병원의 방사선과는 Film-Screen system에서 Full-PACS를 통한 DR 환경으로 변화하고 있다. Full- PACS를 사용하고 있는 본원에서는 DR환경에서의 일반촬영 System중 CR과 DDR의 최적노출조건과 그에 따른 Image qu

  • PDF

Evaluation of functional suitable digital complete denture system based on 3D printing technology

  • Deng, Kehui;Chen, Hu;Wang, Yong;Zhou, Yongsheng;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.361-372
    • /
    • 2021
  • PURPOSE. To improve the clinical effects of complete denture use and simplify its clinical application, a digital complete denture restoration workflow (Functional Suitable Digital Complete Denture System, FSD) was proposed and preliminary clinical evaluation was done. MATERIALS AND METHODS. Forty edentulous patients were enrolled, of which half were treated by a prosthodontic chief physician, and the others were treated by a postgraduate student. Based on the primary impression and jaw relation obtained at the first visit, diagnostic denture was designed and printed to create a definitive impression, jaw relation, and esthetic confirmation at the second visit. A redesigned complete denture was printed as a mold to fabricate final denture that was delivered at the third visit. To evaluate accuracy of impression made by diagnostic denture, the final denture was used as a tray to make impression, and 3D comparison was used to analyze their difference. To evaluate the clinical effect of FSD, visual analogue scores (VAS) were determined by both dentists and patients. RESULTS. Two visits were reduced before denture delivery. The RMS values of 3D comparison between the impression made via diagnostic dentures and the final dentures were 0.165 ± 0.033 mm in the upper jaw and 0.139 ± 0.031 mm in the lower jaw. VAS ratings were between 8.5 and 9.6 in the chief physician group, while 7.7 and 9.5 in the student group; there was no statistical difference between the two groups. CONCLUSION. FSD can simplify the complete denture restoration process and reduce the number of visits. The accuracy of impressions made by diagnostic dentures was acceptable in clinic. The VASs of both dentists and patients were satisfied.