• Title/Summary/Keyword: Digital Hearing Aid

Search Result 68, Processing Time 0.024 seconds

Expansion of ATSC 3.0-Based Disaster Broadcasting Service for the Visually and Hearing Impaired

  • Song, Chong-Hyun
    • Journal of Multimedia Information System
    • /
    • v.9 no.3
    • /
    • pp.227-232
    • /
    • 2022
  • Disasters are now becoming commonplace and especially the vulnerable group such as the disabled, the elderly, children and foreigners are in a state of overlapping disasters. In this situation, ATSC 3.0-based UHDTV disaster information service for the visually and hearing impaired has been developing. This study focuses on the demand data collected through in-depth interview with the impaired. The demand analysis data is very important to development process of technology. The results of the interview show that it is essential to link the UHDTV disaster signals with home-network, IoT, wearable devices, and various assistive devices for the impaired (hearing aid, smart light bulbs, warning light, etc.). In outdoor space, UHDTV disaster information must be connected to public display media, digital signage, kiosk, screens in bus or taxi. If communication aids for the visually and hearing impaired are equipped with a function that can transmit and receive disaster information, it will help to minimize disaster damage.

Simulation of the Loudness Recruitment using Sensorineural Hearing Impairment Modeling (감음신경성 난청의 모델링을 통한 라우드니스 누가현상의 시뮬레이션)

  • Kim, D.W.;Park, Y.C.;Kim, W.K.;Doh, W.;Park, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.63-66
    • /
    • 1997
  • With the advent of high speed digital signal processing chips, new digital techniques have been introduced to the hearing instrument. This advanced hearing instrument circuitry has led to the need or and the development of new fitting approach. A number of different fitting approaches have been developed over the past few years, yet there has been little agreement on which approach is the "best" or most appropriate to use. However, when we develop not only new hearing aid, but also its fitting method, the intensive subject-based clinical tests are necessarily accompanied. In this paper, we present an objective method to evaluate and predict the performance of hearing aids without the help of such subject-based tests. In the hearing impairment simulation (HIS) algorithm, a sensorineural hearing impairment model is established from auditory test data of the impaired subject being simulated. Also, in the hearing impairment simulation system the abnormal loudness relationships created by recruitment was transposed to the normal dynamic span of hearing. The nonlinear behavior of the loudness recruitment is defined using hearing loss unctions generated from the measurements. The recruitment simulation is validated by an experiment with two impaired listeners, who compared processed speech in the normal ear with unprocessed speech in the impaired ear. To assess the performance, the HIS algorithm was implemented in real-time using a floating-point DSP.

  • PDF

Effect of the STereoLithography File Structure on the Ear Shell Production for Hearing Aids According to DICOM Images (DICOM 영상에 의한 STL 파일 구조가 보청기 이어 쉘 제작에 미치는 영향)

  • Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.121-126
    • /
    • 2017
  • A technique for producing the ear shell for a hearing aid using DICOM (Digital Imaging and Communication in Medicine) image and a 3D printing was studied. It is a new application method, and is an application technique that can improve the safety and infection of hearing aid users and can reduce the production time and process stages. In this study, the effects on the shape surface were examined before and after the printing of the ear shell using a 3D printer based on the values obtained from the raw data of the DICOM images at the volumes of 0.5 mm, 1.0 mm, and 2.0 mm, respectively. Before the printing, relative relationship was compared with respect to the STL (STereoLithography) file structure; and after the printing, the intervals of the layered structure of the ear shell shape surface were compared by magnifying them using a microscope. For the STL file structure, the numbers of triangular vertices, more than five intersecting points, and maximum intersecting points were large in the order of 0.5 mm, 1.0 mm, and 2.0 mm, respectively; and the triangular structure was densely distributed in the order of the bending, angle, and crest regions depending on the sinuosity of the external auditory meatus shape. As for the ear shell shape surface examined by the digital microscope, the interval of the layered structure was thick in the order of 2.0 mm, 1.0 mm, and 0.5 mm. For the STL surface structure mentioned above, the intersecting STL triangular structure was denser as the sinuosity of the 3D ear shell shape became more irregular and the volume of the raw data decreased.

A Study on the Performance of Noise Reduction using Multi-Microphones for Digital Hearing Aids (디지털 보청기를 위한 다중 마이크로폰을 이용한 잡음제거 성능 연구)

  • Kang, Hyun-Deok;Song, Young-Rok;Lee, Sang-Min
    • Journal of IKEEE
    • /
    • v.14 no.1
    • /
    • pp.47-54
    • /
    • 2010
  • In this study, we analyzed the reduction of noise in a noise environment using 2, 3, 4 or 5 microphones in digital hearing aids. In order to be able to use this in actual digital hearing aids, we made the experiment microphone set similar to the behind-the-ear type (BTE) and then recorded the signal accordingly, with each situation. With the recorded signals, we reduced the noise in each signal by a noise reduction algorithm using multi-microphones. As a result, in the case of By comparing the SNR (Signal to Noise Ratio) and PESQ (Perceptual Evaluation of Speech) measurements, before and after the noise reduction, the results showed that the improvement in performance was highest when three or four microphones were used. Generally, when two or more microphones were used, we found that as the number of microphones increased there was an increase in performance.

Desgin of Low-power, Low-noise Preamplifier for Digital Hearing-Aids (디지털 보청기를 위한 저전력, 저잡음 전치증폭기 설계)

  • Im, Saemin;Park, Sang-Gyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.219-225
    • /
    • 2012
  • A low-power, low-noise pre-amplifier for digital hearing-aid application is designed. This pre-amplifier amplifies single-ended signal from an electret microphone, and produces differential output to be delivered to an ADC. It has a variable gain of 3.6, 7.2, 14.4 and 28.8 with a bandwidth between 100Hz~10kHzon. The measurement results show 85 dB of SNR, 0.05 % of harmonic distortion and $200{\mu}W$ of power consumption with 1.2V supply.

An Improvement of Speech Hearing Ability for sensorineural impaired listners (감음성(感音性) 난청인의 언어청력 향상에 관한 연구)

  • Lee, S.M.;Woo, H.C.;Kim, D.W.;Song, C.G.;Lee, Y.M.;Kim, W.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.240-242
    • /
    • 1996
  • In this paper, we proposed a method of a hearing aid suitable for the sensorineural hearing impaired. Generally as the sensorineural hearing impaired have narrow audible ranges between threshold and discomfortable level, the speech spectrum may easily go beyond their audible range. Therefore speech spectrum must be optimally amplified and compressed into the impaired's audible range. The level and frequency of input speech signal are varied continuously. So we have to make compensation input signal for frequency-gain loss of the impaired, specially in the frequency band which includes much information. The input sigaal is divided into short time block and spectrum within the block is calculated. The frequency-gain characteristic is determined using the calculated spectrum. The number of frequency band and the target gain which will be added input signal are estimated. The input signal within the block is processed by a single digital filter with the calculated frequency-gain characteristics. From the results of monosyllabic speech tests to evaluate the performance of the proposed algorithm, the scores of test were improved.

  • PDF

Design of Signal Processing Circuit for Semi-implantable Middle Ear Hearing Device with Bellows Transducer (벨로즈형 진동체를 갖는 반이식형 인공중이용 신호처리회로 설계)

  • Kim, Jong Hoon;Shin, Dong Ho;Seong, Ki Woong;Cho, Jin-Ho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.1
    • /
    • pp.63-71
    • /
    • 2017
  • In this paper, a signal processing circuit for semi-implantable middle ear hearing device is designed using the TCBT which is recently proposed for a new middle ear transducer that can be implanted at round window of cochlea. The designed semi-implantable hearing device transmits digital sound signal from external device located at behind the ear to the internal device implanted under the skin using inductive coupling link methods with high efficiency. The coils and signal processing circuits are designed and implemented considering the total transmission and reception distance including skin thickness of temporal bone for the semi-implantable hearing device. And also, to improve the data transmission efficiency, the output circuits which can supply sufficient signal power is designed. In order to confirm operation of semi-implantable hearing device using inductive coupling link, the circuit analysis was performed using PSpice, and the performance was verified by implementing a signal processing board of an available size.

Effect of Digital Noise Reduction of Hearing Aids on Music and Speech Perception

  • Kim, Hyo Jeong;Lee, Jae Hee;Shim, Hyun Joon
    • Journal of Audiology & Otology
    • /
    • v.24 no.4
    • /
    • pp.180-190
    • /
    • 2020
  • Background and Objectives: Although many studies have evaluated the effect of the digital noise reduction (DNR) algorithm of hearing aids (HAs) on speech recognition, there are few studies on the effect of DNR on music perception. Therefore, we aimed to evaluate the effect of DNR on music, in addition to speech perception, using objective and subjective measurements. Subjects and Methods: Sixteen HA users participated in this study (58.00±10.44 years; 3 males and 13 females). The objective assessment of speech and music perception was based on the Korean version of the Clinical Assessment of Music Perception test and word and sentence recognition scores. Meanwhile, for the subjective assessment, the quality rating of speech and music as well as self-reported HA benefits were evaluated. Results: There was no improvement conferred with DNR of HAs on the objective assessment tests of speech and music perception. The pitch discrimination at 262 Hz in the DNR-off condition was better than that in the unaided condition (p=0.024); however, the unaided condition and the DNR-on conditions did not differ. In the Korean music background questionnaire, responses regarding ease of communication were better in the DNR-on condition than in the DNR-off condition (p=0.029). Conclusions: Speech and music perception or sound quality did not improve with the activation of DNR. However, DNR positively influenced the listener's subjective listening comfort. The DNR-off condition in HAs may be beneficial for pitch discrimination at some frequencies.

Effect of Digital Noise Reduction of Hearing Aids on Music and Speech Perception

  • Kim, Hyo Jeong;Lee, Jae Hee;Shim, Hyun Joon
    • Korean Journal of Audiology
    • /
    • v.24 no.4
    • /
    • pp.180-190
    • /
    • 2020
  • Background and Objectives: Although many studies have evaluated the effect of the digital noise reduction (DNR) algorithm of hearing aids (HAs) on speech recognition, there are few studies on the effect of DNR on music perception. Therefore, we aimed to evaluate the effect of DNR on music, in addition to speech perception, using objective and subjective measurements. Subjects and Methods: Sixteen HA users participated in this study (58.00±10.44 years; 3 males and 13 females). The objective assessment of speech and music perception was based on the Korean version of the Clinical Assessment of Music Perception test and word and sentence recognition scores. Meanwhile, for the subjective assessment, the quality rating of speech and music as well as self-reported HA benefits were evaluated. Results: There was no improvement conferred with DNR of HAs on the objective assessment tests of speech and music perception. The pitch discrimination at 262 Hz in the DNR-off condition was better than that in the unaided condition (p=0.024); however, the unaided condition and the DNR-on conditions did not differ. In the Korean music background questionnaire, responses regarding ease of communication were better in the DNR-on condition than in the DNR-off condition (p=0.029). Conclusions: Speech and music perception or sound quality did not improve with the activation of DNR. However, DNR positively influenced the listener's subjective listening comfort. The DNR-off condition in HAs may be beneficial for pitch discrimination at some frequencies.