• Title/Summary/Keyword: Digestion Method

Search Result 554, Processing Time 0.032 seconds

Anaerobic digestion for food wastewater using HADS Pilot Plant and analysis of microbial community in the digester (HADS Pilot Plant를 이용한 음폐수의 혐기성 소화 및 미생물 군집 변화 분석)

  • Ju, Dong-Hun;Lee, Jung-Min;Park, Seong-Bum;Sung, Hyun-Je;Bae, Jae-Sang;Sang, Byoung-In
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.2
    • /
    • pp.76-83
    • /
    • 2010
  • We(Hansol EME Co. Ltd.) proceeded anaerobic digestion test for domestic food wastewater applying to two operating method for increasing of OLR. The methods are as follows. One was the rapidity operating method which was increasing the OLR continuously and rapidly and the other was the terraced operating method which was increasing the OLR having adaptation period for each step. As a result of this tests, the ratio of VFA/Alkalinity of the process was very unstable under the rapidity operating method then the volume of produced biogas was dramatically decreased. However the process was shown stable performance under the terraced operating method maintaining the ratio of VFA/Alkalinity less than 0.4. Also, the process was performing the biogas recovery of $0.8Nm^3/kgVS_{rem}/d$ and the VS removal ratio of 85%. T-RFLP analysis about the community of bacteria and methanogen is also conducted to check the change of the microbial community according to the methods of OLR increasing operation. The microbial community was changed by the methods of OLR increasing operation according to the result of T-RFLP analysis. Although the anaerobic digestion test was executed by same pilot plant, the reactivity and the tolerance of microbial community for surrounding environment could be considerably changed by the operating method for the process.

Keratanase II Digestion Accompanied with a Liquid Chromatography/Tandem Mass Spectrometry for Urinary Keratan Sulfate Quantitative Analysis

  • Chuang, Chih-Kuang;Lin, Hsiang-Yu;Wang, Tuen-Jen;Huang, Sung-Fa;Lin, Shuan-Pei
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • v.3 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: Mucopolysaccharidosis IV (MPS IV) is a disease characterized by deficient activity of N-acetylgalactosamine-6-sulfatase (GALNS) causing excessive lysosomal storage of keratan sulfate (KS). The identification of the relevant disaccharide units of KS after keratanase II digestion followed by liquid chromatography/tandem mass spectrometry detection (LC-MS/MS) is validated and applicable for the preliminary diagnosis of MPS IV. Methods: A total of 67 urine samples were collected and analyzed from 11 MPS IV patients comprising 10 MPS IVA and one MPS IVB patients, and 56 normal controls. Urinary glycosaminoglycan was first precipitated by the Alcian blue method followed by a digestion of keratanase II. The protonated species of the digested disaccharide products were detected by using multiple reaction monitoring experiment. Results: One particular disaccharide of KS was selected. The transition mass-to-charge (m/z) of the parent ion and its daughter ion after collision was $462.0{\rightarrow}97.0$, whereas the chondrosine used as an internal standard in this assay was m/z $353.9{\rightarrow}73.0$. The results corresponded well with the two-dimensional electrophoresis method. The quantities of urinary KS were significantly raised in confirmed MPS IV patients when comparing with those of normal controls ($170.2{\pm}81.1$ vs. $4.06{\pm}1.92{\mu}g/mL$). Conclusion: The LC-MS/MS method for MPS IVA determination is specific, sensitive, validated, and applicable for urinary KS quantification. This method can be used not only as a first-line biochemistry examination of MPS IVA, but also as an outcome survey after enzyme replacement therapy.

Determination of Lead in Urine by Atomic Absorption Spectrophotometry (원자흡광법을 이용한 요중 연 배설량의 정량)

  • Paik, Nam-Won;Yoon, Bock-Sang;Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.2
    • /
    • pp.377-381
    • /
    • 1974
  • Determination of lead in urine is important in industrial hygiene and toxicology. Dithizone method has been principally used for the determination of lead in urine, which gives accurate results in skilful hands but is usually complex and time-consuming. Atomic absorption spectrophotometry is a new simple method and several procedures have been described. However, the influences of pH and the presence of chelating agents during treatment of lead poisoning are not clear. The purpose of this study was to find out the effect of pH and chelating agents on the determination of lead using Shimadzu atomic absorption/flame spectrophotometer, model AA-610. The results obtained were as follows: 1. The atomic absorption spectrophotometry(AAS) could be applied without prior acid digestion to specimens in the absence of chelating agents. The absorbance at $2,170\;{\AA}$, though more sensitive, was more noisy electronically. Therefore, we selected the wavelength of $2,833\;{\AA}$ plus scale expansion. 2. The optimal pH was in the range from 2 to 3. 3. The sensitivity was $0.075{\mu}g/ml/%$ and detection limit was about $0.2{\mu}g/ml$. 4. In the presence of EDTA, lead could not be completely determined without prior acid digestion. 5. On specimens from patients receiving penicillamine therapy, a comparison was made between the values obtained with dithizone method and AAS method with prior acid digestion. The results of comparison showed a very good agreement.

  • PDF

Solid-liquid Separation Characteristics of Membrane Filter Press according to Coagulant Properties of Anaerobic Digestion Waste Water (혐기소화폐액의 응집제 특성에 따른 멤브레인 필터프레스의 고액분리 특성)

  • Han, Seong Kuk;Jung, Hee Suk;Song, Hyoung Woon;Kim, Ho;Ahn, Dae Hyun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.3
    • /
    • pp.23-32
    • /
    • 2014
  • Recently, it is increase in the processing of organic waste using anaerobic digestion. Therefore, the studies on the processing method for increasing the anaerobic digestion waste water. But it is very difficult to solid-liquid separation, because the characteristics of anaerobic digestion waste water. So this study evaluate solid-liquid separation efficiency of anaerobic digestion sludge using CST(Capillary Suction Time), TTF(Time to Filter). To address this problem, a membrane filter press of the lab scale was produced and the anaerobic digestion wastewater was applied to it. Polymer coagulants were found to be most suitable 7192PLUS and 1T60, It is necessary to minimum injection concentration is 7192PLUS (200 mg/L), 1T60 (100 mg/L). To evaluate dehydration efficiency, it was measured the moisture content of the dehydrated cake and suspended solids of decanted water. As a result, showed that a high removal efficiency of 97.4% when the solid-liquid separation using the membrane filter press. And the moisture content of the dehydrated cake was less than 65%.

Studies on the Fermentation of Fish Protein -1. A Model Design of Fermentor- (수산 발효식품 제조에 관한 연구 -1. 어육 발효조의 설계-)

  • Lee, Kang-Ho;Choi, Ho-Yeon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.1 no.1
    • /
    • pp.51-62
    • /
    • 1972
  • In Korea, fermented fish has been playing an important role as a preserved and flavor rich food. It is said that the digestion of fish protein is due to both action of intrinsic (autolytic enzymes) and bacterial enzymes in fish. The mass production of fermented fish has been impeded since traditional method of fermentation requires a long duration for a complete digestion. A high concentration of salt and unsanitary condition are also considered disadvantages of the old method. To improve the quality of the product and to develop mechanized process of fermentation, fermentors which have such control device as temperature, pH and agitation control system have been urgently needed. In this study, a model design of a fermentor is studied. The calculation was based on the optimum conditions for enzymatic hydrolysis of fish protein which involve temperature, pH, viscosity and other factors.

  • PDF

Comparison of USEPA Digestion Methods for Trace Metal Analysis Using SRM

  • Shin, Mi-Young;Yoon, Hyeon;Kim, Youn-Tae;Yoon, Cheol-Ho;Woo, Nam-Chil
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.223-226
    • /
    • 2004
  • The importance of a proper sample preparation and analysis technique has getting attention due to the complicity of toxic elements of interest from environmental samples depend on analytical purposes. It is critical to use proper analytical method to evaluate trace elements concentration in many environmental samples especially for making remediation decisions. Therefore, it is critical to apply a proper sampling and analytical method such as EPA publication SW-846 (Test Methods for Evaluating Solid Waste, Physical/chemical Methods). The objective of this study was to compare the USEPA Methods 3050B, modified 3050B, 305 la, and KBSI method (modified EPA 3052 Method) in term of recovery rate of metals. The NIST SRM (Montana soil) was used to compare the extraction and digestion efficiency. After sample has been collected the analysis were achieved by ICP-MS (Elan 6100, Perkin Elmer) as well as ICP-AES (Ultima 2C, JY) for trace elements and major elements.

  • PDF

Method and proficiency test for analysis of toxic metals in livestock products by ICP/MS (ICP/MS를 이용한 축산물의 유해중금속 분석방법 및 숙련도 검증)

  • Jang, Jung-Hee;Kim, Dong-Gyu;Kwon, Hyun-Jeong;Lim, Chae-Mi;Son, Seong-Wan;Kim, MeeKyung
    • Korean Journal of Veterinary Research
    • /
    • v.52 no.2
    • /
    • pp.69-74
    • /
    • 2012
  • The analytical method of trace toxic metals in livestock products was confirmed and validated through certified reference material (CRM) and the international proficiency tests. There are some difficulties to determine low levels of toxic metals in livestock products because of interferences due to the matrix. The recoveries of CRM (NIST 1577c) ranged from 73.9 to 119% for lead and from 86.4 to 111% for cadmium in bovine liver. The international proficiency tests were carried out with the milk powder and cocoa powder samples including metals provided by Food Analysis Performance Assessment Scheme (FAPAS$^{(R)}$, UK). The test samples were prepared by microwave digestion using solution of $HNO_3:H_2O_2:H_2O$ (v/v/v = 5 : 2 : 4) and analyzed by ICP/MS. The analytical result of cadmium in milk powder was $121{\mu}g/kg$ with -0.3 of the z-score compared to the assigned value of $131{\mu}g/kg$ by FAPAS$^{(R)}$. The analytical results of lead and cadmium in cocoa powder were $29.2{\mu}g/kg$ and $97.6{\mu}g/kg$, respectively, which satisfied the assigned values of $34.2{\mu}g/kg$ for lead and $126{\mu}g/kg$ for cadmium by FAPAS$^{(R)}$. It is verified that the analytical method is accurate and reliable to determine trace lead and cadmium in livestock products by microwave digestion and ICP/MS.

A Study on the Acid Digestion Bomb Pretreatment Method of Fire Retardant Chemicals (DBDPE-$Sb_2O_3$) for the Determination of Antimony (DBDPE-$Sb_2O_3$ 중 Sb를 분석하기 위한 가압 산분해 전처리 연구)

  • Choi, Jong-Keum;Park, Je-An;Park, Kyung-Su;Kim, Sun-Tae;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.731-735
    • /
    • 2000
  • The acid digestion bomb pretreatment method for the determination of antimony in a commercial fire retardant material sample (DBDPE-$Sb_2O_3$) was studied. DBDPE-$Sb_2O_3$ sample was digested with $H_2SO_4:HCl$(1:2) mixture in digestion bomb at $220^{\circ}C$ for 2 hrs. and antimony was determined by atomic absorption spectrophotometry. Recovery of 99.6-99.8% and C.V. of 0.94-1.07% for Sb was obtained for spiked real samples. In the present method, the analytical results obtained for antimony were 40.3 and 36.3% (w/w), respectively.

  • PDF