• Title/Summary/Keyword: Diffusion imaging

Search Result 443, Processing Time 0.03 seconds

MRI Evaluation of Suspected Pathologic Fracture at the Extremities from Metastasis: Diagnostic Value of Added Diffusion-Weighted Imaging

  • Sun-Young Park;Min Hee Lee;Ji Young Jeon;Hye Won Chung;Sang Hoon Lee;Myung Jin Shin
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.812-822
    • /
    • 2019
  • Objective: To assess the diagnostic value of combining diffusion-weighted imaging (DWI) with conventional magnetic resonance imaging (MRI) for differentiating between pathologic and traumatic fractures at extremities from metastasis. Materials and Methods: Institutional Review Board approved this retrospective study and informed consent was waived. This study included 49 patients each with pathologic and traumatic fractures at extremities. The patients underwent conventional MRI combined with DWI. For qualitative analysis, two radiologists (R1 and R2) independently reviewed three imaging sets with a crossover design using a 5-point scale and a 3-scale confidence level: DWI plus non-enhanced MRI (NEMR; DW set), NEMR plus contrast-enhanced fat-saturated T1-weighted imaging (CEFST1; CE set), and DWI plus NEMR plus CEFST1 (combined set). McNemar's test was used to compare the diagnostic performances among three sets and perform subgroup analyses (single vs. multiple bone abnormality, absence/presence of extra-osseous mass, and bone enhancement at fracture margin). Results: Compared to the CE set, the combined set showed improved diagnostic accuracy (R1, 84.7 vs. 95.9%; R2, 91.8 vs. 95.9%, p < 0.05) and specificity (R1, 71.4% vs. 93.9%, p < 0.005; R2, 85.7% vs. 98%, p = 0.07), with no difference in sensitivities (p > 0.05). In cases of absent extra-osseous soft tissue mass and present fracture site enhancement, the combined set showed improved accuracy (R1, 82.9-84.4% vs. 95.6-96.3%, p < 0.05; R2, 90.2-91.1% vs. 95.1-95.6%, p < 0.05) and specificity (R1, 68.3-72.9% vs. 92.7-95.8%, p < 0.005; R2, 83.0-85.4% vs. 97.6-98.0%, p = 0.07). Conclusion: Combining DWI with conventional MRI improved the diagnostic accuracy and specificity while retaining sensitivity for differentiating between pathologic and traumatic fractures from metastasis at extremities.

Implementation of Regional Cerebral Blood Volume Map Using Perfusion Magnetic Resonance Image Process Algorithm (관류자기공명 영상처리 알고리즘을 이용한 대뇌 혈류량 맵의 구현)

  • Park Byung-Rae
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.5
    • /
    • pp.296-304
    • /
    • 2005
  • Quantitative analysis compare to dynamic characteristic change of the regional cerebral blood volume(rCBV) after development of cerebral fat embolism in cats using perfusion magnetic resonance(MR) Imaging. Twenty cats were used. Linoleic acid (n=11) were injected into the internal carotid artery using microcatheter through the transfemoral approach. Polyvinyl alcohol (Ivalon) (n=9) was injected as a control group. Perfusion MR images were obtained at 30 minutes and 2 hours after embolization, based on T2 and diffusion-weighted images. The data was time-to-signal intensity curve and ${\Delta}R_2^*$ curve were obtained continuously with the aid of home-maid image process algorithm and IDL(interactive data Banguage, USA) softwares. The ratios of rCBV increased significantly at 2 hours compared with those of 30 minutes (P<0.005). In conclusion, cerebral blood flow decreased in cerebral fat embolism immediately after embolization and recovered remarkably in time course. It is thought that clinically informations to dynamic characteristic change of the cerebral hemodynamics to the early finding in cerebral infarction by diffusion weighted imaging(DWI) and perfusion weighted imaging(PWI).

  • PDF

Usefulness of the High B-value DWI in Brain Tumors (뇌종양 확산강조영상에서 High B-value의 유용성 평가)

  • Kim, Jin-tae;Byun, Jae-Hu;Park, Yong-Seong;Lee, Rae-Gon;Hwang, Seon-Kwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.33-41
    • /
    • 2015
  • This study attempts to examine the clinical usefulness of High b-value DWI (diffusion weighted imaging) for brain tumors with an edema. Subjects were seven patients selected from 65 patients who received an MRI scan for suspected encephalopathy and confirmed diagnosis at our hospital from February to July 2015 (male: 7, average age : 66 years old). As test equipment, 3.0T MR System (ACHIEVA Release, Philips, Best, The Netherlands) and 8Channel SENSE Head Coill were used. DWI checks on the use of the variable TR 5460ms, TE 132ms, Slice Thickness 4mm, gap 1mm, Slice number 29 is, 3D T1WI is TR 8.4ms, TE 3.9ms, matrix size $240{\times}240$, Slice can set 180 piecesIt was. b value of 0, 1,000, 2,000 s/mm2 with DWI acquisition and 3D T1WI enhancement five minutes after the Slice Thickness 3mm, gap 0mm to reconstruct the upper face axis (MPR TRA CE) was. As for the experiment, in b-value 1,000 and 2,000 images, SNR and the lesion at the lesion site and CNR in the normal site opposite to the lesion are measured. WW(window width) and WL(window level) are made equal in MRICro software, and the volume of the lesion is measured from each of b-value and MPR TRA CE image. Using SPSS ver. 1.8.0.0 Mann Whitney-test was analyzed for SNR and CNR, while Kruskal-Wallis test was analyzed for volume.

  • PDF

Nomogram Models for Distinguishing Intraductal Carcinoma of the Prostate From Prostatic Acinar Adenocarcinoma Based on Multiparametric Magnetic Resonance Imaging

  • Ling Yang;Xue-Ming Li;Meng-Ni Zhang;Jin Yao;Bin Song
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.668-680
    • /
    • 2023
  • Objective: To compare multiparametric magnetic resonance imaging (MRI) features of intraductal carcinoma of the prostate (IDC-P) with those of prostatic acinar adenocarcinoma (PAC) and develop prediction models to distinguish IDC-P from PAC and IDC-P with a high proportion (IDC ≥ 10%, hpIDC-P) from IDC-P with a low proportion (IDC < 10%, lpIDC-P) and PAC. Materials and Methods: One hundred and six patients with hpIDC-P, 105 with lpIDC-P and 168 with PAC, who underwent pretreatment multiparametric MRI between January 2015 and December 2020 were included in this study. Imaging parameters, including invasiveness and metastasis, were evaluated and compared between the PAC and IDC-P groups as well as between the hpIDC-P and lpIDC-P subgroups. Nomograms for distinguishing IDC-P from PAC, and hpIDC-P from lpIDC-P and PAC, were made using multivariable logistic regression analysis. The discrimination performance of the models was assessed using the receiver operating characteristic area under the curve (ROC-AUC) in the sample, where the models were derived from without an independent validation sample. Results: The tumor diameter was larger and invasive and metastatic features were more common in the IDC-P than in the PAC group (P < 0.001). The distribution of extraprostatic extension (EPE) and pelvic lymphadenopathy was even greater, and the apparent diffusion coefficient (ADC) ratio was lower in the hpIDC-P than in the lpIDC-P group (P < 0.05). The ROC-AUCs of the stepwise models based solely on imaging features for distinguishing IDC-P from PAC and hpIDC-P from lpIDC-P and PAC were 0.797 (95% confidence interval, 0.750-0.843) and 0.777 (0.727-0.827), respectively. Conclusion: IDC-P was more likely to be larger, more invasive, and more metastatic, with obviously restricted diffusion. EPE, pelvic lymphadenopathy, and a lower ADC ratio were more likely to occur in hpIDC-P, and were also the most useful variables in both nomograms for predicting IDC-P and hpIDC-P.

Coexistence of Intracranial Squamous Cell Carcinoma and Epidermoid Cyst: a Case with Consecutive Imaging Findings

  • Lee, Chae Woon;Park, Ji Eun;Lee, Jeong Hyun;Kim, Ho Sung;Kim, Sang Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.3
    • /
    • pp.172-176
    • /
    • 2018
  • In contrast to well-known imaging findings of intracranial epidermoid cysts on magnetic resonance imaging, those of intracranial squamous cell carcinoma (SqCC) are relatively unknown. We present a case of coexistence of intracranial SqCC and epidermoid cyst, with consecutive follow up over 14 months. Based on our case, a solid enhancing portion adjacent to a typically-looking epidermoid cyst may become a clue for coexistence of intracranial SqCC. An initial contrast enhancement and/or heterogeneous signal on diffusion weighted imaging may become a useful diagnostic clue, but more importantly, sudden rapid growth is important in formulating diagnosis.

In Vivo and In Vitro Studies of the Steady State Free Precession-Diffusion-Weighted MR Imagings on Low b-value : Validation and Application to Bone Marrow Pathology

  • Byun, Woo-Mok
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.119-128
    • /
    • 2007
  • Purpose : The purpose of this study was a phantom study to measure the diffusion properties of water molecules by steady-state free precession diffusion-weighted imaging (SSFP- DWI) with a low b-value and to determine if this sequence might be useful for application to the evaluation of bone marrow pathology. Materials and methods : 1. The phantom study: A phantom study using two diffusion weighted sequences for the evaluation of the diffusion coefficient was performed. Three water-containing cylinders at different temperatures were designed: phantom A was $3^{\circ}C$, B was $23^{\circ}C$ and C was $63^{\circ}C$. Both SSFP and echo planar imaging (EPI) sequences (b-value: $1000s/mm^2$) were performed for comparison of the diffusion properties. The Signal to noise ratios (SNR) and apparent diffusion coefficient (ADC) values of the three phantoms using each diffusion-weighted sequence were assessed. 2. The Clinical study: SSFP-DWI was performed in 28 patients [sacral insufficiency fractures (10), osteoporotic lumbar compression fractures (10), malignant compression fractures (8)]. To measure the ADC maps, a diffusion-weighted single shot stimulated echo-acquisition mode sequence ($650s/mm^2$) was obtained using the same 1.5-T MR imager Results : For the phantom study, the signal intensity on the SSFP as well as the classic EPI-based DWI was decreased as the temperature increased in phantom A to C. The ADC values of the phantoms on EPI-DWI were $0.13{\times}10^{-3}mm^2/s$ in phantom A, $0.22{\times}10^{-3}mm^2/s$ in B and $0.37{\times}10^{-3}mm^2/s$. in C. The SSFP can be regarded as a DWI sequence in view of the series of signal decreases. Conclusion : Bone marrow pathologies with different diffusion coefficients were evaluated by SSFP-DWI. All benign fractures were hypointense compared to the adjacent normal bone marrow where as the malignant fractures were hyperintense compared to the adjacent normal bone marrow.

  • PDF

The quantitative analysis of Diffusion Weighted Imaging in Breast MRI (유방 MRI 검사에서 확산강조영상의 정량적 분석)

  • Cho, Jae-Hwan;Kim, Hyeon-Ju;Hong, Yin-Sik;Lee, Hae-Kag
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.149-154
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of diffusion weighted images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, diffusion weighted images and ADC map images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The diffusion weighted images showed higher SNR and CNR at the lesion area. In addition, the ADC values were lower at the lesion area.

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.

The Study on Signal to Noise Ratio of Single-Shot Turbo Spin Echo to Reduce Image Distortion in Brain Stem Diffusion MRI (뇌줄기 확산강조 자기공명영상검사 시 뒤틀림을 줄이기 위한 SS-TSE 기법의 신호대잡음비 연구)

  • Koo, Nohyun;Lee, Hobeom;Choi, Kwanwoo;Son, Soonyong;Yoo, Beonggyu
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.241-246
    • /
    • 2016
  • The purpose of this study was to investigate the problems of low signal-to-noise ratio(SNR) of single-shot turbo spin echo(SS-TSE) by quantifying numerically decreased signal to noise ratio. Thirty five patients without brain disease underwent diffusion MRI in 3T scanner from July to October in 2015. Single shot echo planar imaging(SS-EPI) which is conventionally used in MRI was taken to compared SS-TSE in SNR of medulla oblongata. As a result, SNR of SS-TSE diffusion(b0=$314.41{\pm}42.96$, b1000=$117.33{\pm}14.04$) is than SS-EPI diffusion(b0=$514.84{\pm}48.97$, b=$208.65{\pm}25.70$) lower in b=0 image(38.9%) and b=1,000 image(43.8%). Thus, diffusion MR using SS-EPI of MS-EPI should be taken for diagnosis of disease in brain stem due to decreased SNR of diffusion using SS-TSE.

The segmentation of brain in MRI using Speckle Reducing Anisotropic Diffusion (Speckle reducing anisotropic diffusion를 이용한 MRI에서의 뇌 영상분할)

  • Yun, Hyun-Joo;Lee, Joung-Min;Kim, Myoung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.10 no.4
    • /
    • pp.1-5
    • /
    • 2004
  • 본 논문에서는 인체의 머리 부분을 촬영한 자기 공명 촬영 영상(MRI: Magnetic Resonance Imaging)에서 뇌 영역의 대뇌 피질 만을 분할하는 방법에 대해 제시하고자 한다. 뇌의 해부학적 구조를 파악할 경우에 영상 내에 함께 보여지는 두개골과 뇌척수액 등을 제외한 대뇌피질 영역을 분할하면 보다 효과적인 정보 분석 및 진단이 가능하게 된다. 본 논문에서는 3단계 알고리즘을 제시한다. 첫번째 단계에서는 Speckle reducing anisotropic diffusion (SRAD)를 이용하여 영상 내에 존재하는 잡음을 제거하기 위한 필터링이다. 두번째 단계에서는 필터링된 결과를 이용하여 추출된 임계값과 사용자의 인터렉션인 씨드 포인트를 통해 영상분할을 수행하고, 세 번째 단계에서는 후 처리를 통해 분할 결과를 보완한다. 영상분할 결과의 정확성을 측정하기 위하여 현재 병원의 의료진들이 사용하고 있는 Mayo clinic사의 Analyze를 이용하여 분할된 결과와의 오류를 측정하였다. 또한 최종 결과에 대해 ultravis를 이용한 볼륨 렌더링으로 영상분할의 최종 결과를 제시하였다.

  • PDF