• Title/Summary/Keyword: Diffusion Combustion

검색결과 442건 처리시간 0.016초

실내외 $NO_2$농도 및 $NO_2$개인폭로량과 이들에 영향을 미치는 요인에 관한 연구 -도시지역 주택 및 주부를 대상으로- (A Study on the Indoor-Outdoor $NO_2$ Levels and Personal Exposures to $NO_2$ with Analysis of factors Affecting the $NO_2$ Concentrations - Centering on Urban Homes and Housewives -)

  • 전진호;이채언;김준연;정요한
    • Journal of Preventive Medicine and Public Health
    • /
    • 제21권1호
    • /
    • pp.132-151
    • /
    • 1988
  • This study was conducted to establish the control program for preventing unfavorable health effects of nitrogen dioxide($NO_2$) exposure in homes by preparing the fundamental data for evaluation of relation-ships between $NO_2$ levels and influencing factors through measurements of indoor-outdoor $NO_2$ levels and personal $NO_2$ exposures for housewives with questionnaire survey on 172 homes in Pusan area from April to June, 1987 $NO_2$ measurements were made by using diffusion tube samplers(Palmes tube $NO_2$ sampler) for one week at 4 sites in homes ; kitchen(KIT), bedroom(BED), living room(LIV), outdoor(OUT) and near the collar of housewives(personal exposure livel, PNO). The details of questionnaire were number of household members(FAM), number of regular smokers (SMOKER), daily number of meals eaten(MEAL), type of housing units(HOUSE), location of house with distance from the heavy traffic roads as walking time(DIST), and of kitchen(KAREA), kind of cooking fuels(FUEL), cooking time of each meal(CTIME), usage of kitchen fan for cooking(FAN), type of heating facilities(HEAT) and so on of subject homes. The Obtained results were as fellows : 1) The mean $NO_2$ level was significantly higher at indoors than outdoors(p<0.01) and the kitchen $NO_2$ level was the highest with $33.7{\pm}13.6ppb$(9.5-81.5ppb). The mean personal exposure level of $NO_2$ for housewives was $20.6{\pm}8.8ppb$(3.1-46.9ppb). 2) The mean indoor $NO_2$ level was significantly higher in the group of household members above 5 than below 4(p<0.05), in detached dwellings than apartments(p<0.001), within 5 minutes of distance than over 5 minutes(p<0.001), in the group of unusing fan(p<0.001), in the group of longer cooking time(p<0.001), and it was in order of coal briquette, gas, electricity and oil by kind of cooking fuels(p<0.05). 3) Variables showing significant correlation(p<0.001) with indoor $NO_2$ level were kitchen $NO_2$ level(r=0.8677), cooking time(r=0.5921), outdoor $NO_2$ level(r=0.5192), personal $NO_2$ exposure level(r=0.4615), usage of kitchen fan(r=0.3573) and location of house(r=-0.2988) 4) As a result of multiple regression analysis, the most significant influencing variable to the kitchen $NO_2$ level was cooking time[KIT=$-0.378{\pm}11.772$(CTIME)+0.298(OUT)+3.102(FAN)], it was kitchen $NO_2$ level to the indoor $NO_2$ level[IND=6.996+0.458(KIT)+0.230(OUT)-1.127(KAREA)], and it was indoor $NO_2$ level to the personal $NO_2$ exposure level[PNO=15.562+0.729(IND)-4.542(DIST)-0.200(KIT)] 5) It was recognized that aritificial ventilation in the kitchen, suppression of unnecessary combustion and replacement of cooking fuel, as much as possible, were effective means for decreasing indoor $NO_2$ levels in homes.

  • PDF

도시아파트의 실내외 $NO_2$ 농도와 관련요인에 관한 연구 (Study on the Indoor-Outdoor $NO_2$ Levels and Related Factors in Urban Apartments)

  • 서병성;김성환;김인식;허윤영;도수영;김정만;김준연
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권3호
    • /
    • pp.609-622
    • /
    • 1997
  • 부산지역의 한 아파트 단지내 489세대를 대상으로 아파트 실내외의 $NO_2$ 농도를 측정하고 동시에 $NO_2$ 농도의 관련 변수들을 조사하여 양자간의 관련성을 파악하고자 본 연구를 실시하였다. 아파트 실내외의 $NO_2$, 농도는 개인용 $NO_2$, 포집관 (Palmes tube)을 사용하여 1995년 8월 16일 - 8월 25일 (하계)과 1996년 1월 15일 - 1월 29일 (동계)간에, 그리고 가스렌지 근처, 주방, 거실 및 아파트 옥외에서 측정하였다. 본 연구의 결과를 요약하면 다음과 같다. 1) 각 세대의 가스렌지 근처와 주방, 거실 및 실외의 평균 $NO_2$, 농도는 하계는 각각 $25.9{\pm}10.0ppb,\;23.3{\pm}8.0ppb,\;19.9{\pm}6.1ppb$$19.0{\pm}6.0ppb$이며, 동계는 $34.5{\pm}16.8ppb\;28.2{\pm}13.4ppb,\;25.3{\pm}12.5ppb$$21.8{\pm}9.8ppb$로서 동하계 공히 부엌의 가스렌지 근처의 $NO_2$, 농도가 최고이었고 하계에 비하여 동계의 실내외 $NO_2$ 농도가 유의하게 높았다. 리 아파트 층수별 $NO_2$ 농도는 하계에는 층수에 따른 $NO_2$, 농도의 유의한 변화가 없었으나, 동계는 16층 이상을 제외하면 층수가 높아짐에 따라 $NO_2$ 농도가 감소하였다. 기 아파트 실내 $NO_2$ 농도의 관련변수는 하계의 경우 층수, 가족수, 1회 식사시 평균 가족수, 취사시 가스렌지 1일 평균 사용횟수, 자연 환기이었고, 동계에는 층수, 가족수, 1회 식사시 평균 가족수, 총 식사 인원수, 식사 횟수, 가족의 총 연령, 취사시 가스렌지 1일 평균 사용 횟수, 조리시 가스렌지 1일 평균 사용 횟수, 호흡기 질환자 유무 등이었다. 4) 아파트 실내 $NO_2$ 농도의 감소 방안으로는 취사 혹은 조리시 환기를 철저히 하고, 완전연소, 연소의 횟수와 시간 단축 및 연료의 대체가 필요하다고 생각한다.

  • PDF