• Title/Summary/Keyword: Diffuser flow

Search Result 425, Processing Time 0.039 seconds

Structural Stability Evaluation of Impeller in Resonant condition due to Diffuser vanes (디퓨저 베인에 의한 공진조건에서의 임펠러 구조 안정성 평가)

  • Kim, Yongse;Kong, Dongjae;Shin, Sangjoon;Im, Kangsoo;Park, Kihoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.877-880
    • /
    • 2017
  • Impeller blades in the centrifugal compressor are subjected to static loads due to the high-speed rotation and steady aerodynamic forces. At the same time, aerodynamic excitations by the interaction between the impeller and the diffuser vanes(DV) periodically excite the impeller blades in resonant conditions, which may lead to high cycle fatigue (HCF) and eventually result in failure of the blades. In order to predict the structural response accurately, the aerodynamic excitation and the major resonant conditions were predicted by performing the unsteady flow analysis and modal analysis using ANSYS. Next, a unidirectional forced vibration analysis was performed by using fluid-structure interaction (FSI) method, and the safety of HCF was evaluated based on the results.

  • PDF

A Study on the Identification of Aeroacoustic Noise and Noise Reduction for a Vacuum Cleaner (청소기의 공력소음 특성 파악 및 저소음화에 관한 연구)

  • 전완호;백승조;김창준
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.6
    • /
    • pp.460-466
    • /
    • 2003
  • The aeroacoustic characteristics and noise reduction method of a centrifugal fan for a bagless vacuum cleaner were studied. The major noise source of vacuum cleaner is the centrifugal fan. The impeller of the fan rotates over 30000 rpm and generates very high-level piercing noise. It was found that the dominant noise source of the fan is generated from the aerodynamic interaction between the highly rotating impeller and stationary diffuser. In order to reduce the high tonal sound generated from the aerodynamic interaction between the impeller and diffuser, tapered impeller was carefully designed and tested. The trailing edge of the tapered impeller was inclined and this reduces the flow interactions between the rotating impeller and the stationary diffuser because of some phase shift. The static efficiency of the new impeller is slightly lower than the conventional one. The overall SPL is reduced about 3.6 dBA. The SPL of blade passing frequency(BPF) is reduced about 6 dBA and the $2^{nd}$ BPF is reduced about 20 dBA. The vacuum cleaner with the tapered impeller has lower noise level than that of the previous impeller and the strong tonal sound was dramatically reduced.

Flow Visualization and Calculation at the Outlet of Propellant Tank Pressurizing Gas Injector (추진제탱크 가압용 인젝터 출구에서의 유동가시화 및 해석)

  • Kwon, Oh-Sung;Han, Sang-Yeop;Kwon, Ki-Jung;Chung, Yong-Cahp
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.1
    • /
    • pp.73-79
    • /
    • 2010
  • Propellant tank pressurizing gas injector is used in the pressurization system of liquid propellant rocket to reduce incoming gas velocity and distribute the gas in the tank. Temperature distribution in the propellant tank ullage is varied according to the gas injector shape, and it has influence on the required pressurant gas and thermal phenomena in the tank. In this paper, diffuser type gas injector was studied to make the ullage have stratified temperature distribution. Injected gas flow at the outlet of prototype diffuser was visulized using particle image velocimetry method and it was compared with the results of calculation. Calculation was well agreed with measurement and was used as an inlet condition of propellant tank ullage calculation.

Improvement of the Ventilation Equipment in a Waste Bunker For a Municipal Waste Incinerator (자원회수시설용 폐기물 벙커의 환기설비설계 개선에 관한 연구)

  • Lee, Tae-Gu;Moon, Jung-Hwan;Hur, Jin-Huek;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.51-59
    • /
    • 2007
  • The waste bunker usually consists of waste entrance zone and waste pit. In this paper, the distributions of air flow, $NH_3$ concentration and $H_2S$ concentration in a waste bunker were investigated to prevent an odor generated in a waste pit from dispersing to the waste entrance zone by numerical method. Four cases were considered such that 1) the waste incinerators is operated, 2) the waste incinerators is stopped, 3) the waste incinerator is operated and the direction of a supply diffuser is $45^{\circ}$ upward, 4) the waste incinerator is stopped and the direction of a supply diffuser is $45^{\circ}$ upward. In case of 1), the fresh air from the waste entrance zone is exhausted smoothly to the main exhaust grill of the waste pit. It means that an odor dispersion to the waste entrance zone will not occur. However in case of 2), the induction of fresh air is so small and the supply air with an odor in waste pit can flow to the waste entrance zone. Therefore, an odor will be dispersed to the waste entrance zone. This paper shows the solution that the supply diffuser with the direction of $45^{\circ}$ upward is chosen. As a result in case of 3) and 4), an odor dispersion to the waste entrance zone does not occurred and on odor is exhausted smoothly to the auxiliary exhaust grill.

Performance of NACA 65-810 Radial Airfoil Impellers (NACA 65-810 반경류 에어포일 임펠러의 성능특성)

  • Kang, Shin-Hyoung;Hu, Shengli
    • The KSFM Journal of Fluid Machinery
    • /
    • v.1 no.1 s.1
    • /
    • pp.24-31
    • /
    • 1998
  • Aerodynamic performance tests and flow measurement were carried out for several radial impellers of NACA 65-810 airfoil. The data base obtained are to be used for verifying the methods of flow analysis and CFD codes. The effects of numbers and span of blades on the performances, efficiency and impeller exit flow are investigated in the present study. The flow rate on the performance curve is proportional to the span of the blade for the same value of fan pressure rise. The magnitude of radial velocity component at the impeller exit gradually decreases from the hub to shroud side. The magnitude of tangential velocity component gradually increases from the hub to shroud side. The way of variations of velocity is the same at the diffuser exit, however, becomes more uniform. The pressure rise performance increases with blade number at the small flow coefficients, however, decreases with the number of blade at the large flow coefficients. This shows that flow guidance in important at the low flow rate and the friction becomes significant at the high flow rate.

  • PDF

Numerical Study on Three-Dimensional Flow in a Mixed-Flow Pump for Irrigation and Drainage (양배수용 사류펌프 내 삼차원 유동에 대한 수치적 연구)

  • Kim, Jin-Hyuk;Ahn, Hyoung-Jin;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.1
    • /
    • pp.17-22
    • /
    • 2010
  • In this paper, numerical study on a mixed-flow pump for irrigation and drainage has been performed based on three-dimensional viscous flow analysis. Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model are discretized by finite volume approximations and solved by the commercial CFD code ANSYS CFX-11.0. A structured grid system is constructed in the computational domain, which has O-type grids near the blade surfaces and H/J-type grids in other regions. The numerical results were validated with experimental data for the heads and efficiencies at different flow coefficients. The efficiency at the design flow coefficient is evaluated with the variation of two geometric variables related to area of discharge and length of the vane in the diffuser. The results show that efficiency of the mixed-flow pump at the design flow coefficient is improved by the modifications of the geometry.

A Numerical Study for Optimum Configuration of Pulverized Coal Nozzle to Prevent Uneven Distribution of Particle (분사된 미분탄의 편중분포 방지를 위한 내부장치 최적화에 관한 수치 해석적 연구)

  • Kim, Hyuk-Je;Song, Si-Hong;Park, Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.270-279
    • /
    • 2000
  • Recently, according to increase in the requirement of electric power, a thermoelectric power plant equipped with pulverized coal combustion system is highly valued, because coal has abundant deposits and a low price compared with others. For efficient use of coal fuel, most of plant makers are studying to improve combustion performance and flame stability, and reduce pollutants emission. One of these studies is how to control the profile of particle injection and velocity dependant on coal nozzle configuration. Basically, nozzle which has mixed flow of gas and particle is required to have the balanced coal concentration at exit, but it is very difficult to obtain that by itself without help of other device. In this study, coal distribution and pressure drop in gas-solid flow are calculated by numerical method in nozzle with various shapes of venturi diffuser as a means to get even coal particle distribution. The tentative correlations of pressure drop and exit coal distribution are deduced as function of the height, length and reducing angle of venturi from the calculated results. When coal hurner nozzle is designed, these equations are very useful to optimize the shape of venturi which minimize uneven particle distribution and pressure drop within coal nozzle.