• 제목/요약/키워드: Diffuser flow

검색결과 425건 처리시간 0.021초

초음속 디퓨져에서 충격파의 진동 (1) -수직충격파의 순간변위 측정- (Shock-Wave Oscillation in a Supersonic Diffuser -Displacement Measurement of Mormal Shock-Wave-)

  • 김희동;엄용균;권순범
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.933-945
    • /
    • 1994
  • A shock-wave in a supersonic flow can be theoretically determined by a given pressure ratio at upstream and downstream flowfields, and then the obtained shock-wave is stable in its position. Under the practical situation in which the shock-wave interacts with the boundary layer along a solid wall, it cannot, however, be stable even for the given pressure ratio being independent of time and oscillates around a time-mean position. In the present study, oscillations of a weak normal shock-wave in a supersonic diffuser were measured by a Line Image Sensor(LIS), and they were compared with the data of the wall pressure fluctuations at the foot of the shock-wave interacting with the wall boundary layer. LIS was incorporated into a conventional schlieren optical system and its signal, instantaneous displacement of the interacting shock-wave, was analyzed by a statistical method. The results show that the displacement of an oscillating shock-wave increase with the upstream Mach number and the dominant frequency components of the oscillating shock-wave are below 200 Hz. Measurements indicated that shock-wave oscillations may not entirely be caused by the boundary layer separation. The statistical properties of oscillations appeared, however, to be significantly affected by shock-induced separation of turbulent boundary layer.

Effects of Casing Shape on the Performance of a Small-sized Centrifugal Compressor

  • Kim, D.W.;Kim, H.S.;Kim, Youn-J.
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권3호
    • /
    • pp.132-139
    • /
    • 2003
  • The effects of casing shapes on the performance and the interaction between an impeller and a casing in a small-sized centrifugal compressor are investigated. Especially, numerical analyses are conducted for the centrifugal compressor with both a circular casing and a volute one. The optimum design for each element (i.e., impeller, diffuser and casing) is important to develop an efficient and compact compressor using alternative refrigerant as working fluids. Typical rotating speed of the compressor is in the range of 40,000∼45,000 rpm. The impeller has backswept blades due to tip clearance and a vane diffuser has wedge type. In order to predict the flow pattern inside an entire impeller, vaneless diffuser and casing, calculations with multiple frames of reference method between the rotating and stationery parts of the domain are carried out. For computations of compressible turbulent flow fields, the continuity and time-averaged Navier-Stokes equations are employed. To evaluate the performance of two types of casings, the static pressure recovery and loss coefficients are obtained for various flow rates. Also, static pressure distributions around casings are studied for different casing shapes, which are very important to predict the distribution of radial load. The static pressure around the casing and pressure difference between the inlet and outlet of the compressor are measured for the circular casing.

Design of partial emission type liquid nitrogen pump

  • Lee, Jinwoo;Kwon, Yonghyun;Lee, Changhyeong;Choi, Jungdong;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권1호
    • /
    • pp.64-68
    • /
    • 2016
  • High Temperature Superconductor power cable systems are being developed actively to solve the problem of increasing power demand. With increases in the unit length of the High Temperature Superconductor power cable, it is necessary to develop highly efficient and reliable cryogenic pumps to transport the coolant over long distances. Generally, to obtain a high degree of efficiency, the cryogenic pump requires a high pressure rise with a low flow rate, and a partial emission type pump is appropriate considering its low specific speed, which is different from the conventional centrifugal type, full emission type. This paper describes the design of a partial emission pump to circulate subcooled liquid nitrogen. It consists of an impeller, a circular case and a diffuser. The conventional pump and the partial emission pump have different features in the impeller and the discharge flow passage. The partial emission pump uses an impeller with straight radial blades. The emission of working fluid does not occur continuously from all of the impeller channels, and the diffuser allows the flow only from a part of the impeller channels. As the area of the diffuser increases gradually, it converts the dynamic pressure into static pressure while minimizing the loss of total pressure. We used the known numerical method for the optimum design process and made a CFD analysis to verify the theoretical performance.

Development of a Performance Prediction Method for Centrifugal Compressor Channel Diffusers

  • Kang, Jeong-Seek;Cho, Sung-Kook;Kang, Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • 제16권8호
    • /
    • pp.1144-1153
    • /
    • 2002
  • A hybrid performance prediction method is proposed in the present study. A channel diffuser is divided into four subregions: vaneless space, semi-vaneless space, channel, and channel exit region. One-dimensional compressible core flow and boundary layer calculation of each region with an incidence loss model and empirical correlation of residuary pressure recovery coefficient of a channel predict the performance of diffusers. Three channel diffusers are designed and tested for validating the developed prediction method. The pressure distributions from an impeller exit to the channel diffuser exit are measured and discussed for various operating conditions from choke to nearly surge conditions. The strong non-uniform pressure distribution which is caused by impeller-diffuser interaction is obtained over the vaneless and semi-vaneless spaces. The predicted performance shows good agreement with the measured performance of diffusers at a design condition as well as at off-design conditions.

유입 선회류에 대한 디퓨져 손실 및 난류특성에 관한 연구 (A Study on Pressure Loss and Turbulent Charactristics in a Conical Diffuser with a Swirl Flow)

  • 정효민;고대권;양정규
    • 수산해양기술연구
    • /
    • 제28권2호
    • /
    • pp.157-163
    • /
    • 1992
  • In this paper, the relationship between static pressure recovery and turbulent energy was presented in case of swirling flows into a conical diffuser. The distributions of turbulent energy in a diffuser sectional area were measured by a hot wire anemometer. The following conclusion can be drawn from the experiment. Diffuser loss is constituted by a dynamic pressure loss and total pressure loss. The static pressure recovery depends strongly on the total pressure loss. The static pressure recovery depends strongly on the total pressure loss, and the turbulent energy varies inversely as the static pressure recovery coefficient.

  • PDF

초음속 이젝터 디퓨져 시스템에서의 충격파 발생기 응용 (Application of Shock Generator to Supersonic Ejector Diffuser System)

  • ;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.200-203
    • /
    • 2011
  • Supersonic ejectors are simple mechanical components, which generally perform mixing and recompression of two fluid streams. Ejectors have found many applications in engineering. In aerospace engineering, they are used for high altitude testing (HAT) of a propulsion system by reducing the pressure of a test chamber. It is composed of three major sections: a vacuum test chamber, a propulsive nozzle, and a supersonic exhaust diffuser (SED). This paper aims at the improvement in HAT facility by focusing attention on the vertical firing rocket test stand with shock generators. Shock generators are mounted inside the SED for improving the pressure recovery. The results clearly showed that the performance of the ejector-diffuser system was improved with the addition of shock generators. The improvement comes in the form of reduction of the starting pressure ratio and the vertical height of test stand. It is also shown that shock generators are useful in reducing the total pressure loss in the SED.

  • PDF

블레이드 후향각이 원심압축기의 성능과 유동에 미치는 영향 (Effects of Blade Back Sweep Angle on the Performance and Flow Field in a Centrifugal Compressor)

  • 정요한;백제현;박준영;최민석
    • 한국유체기계학회 논문집
    • /
    • 제16권2호
    • /
    • pp.48-53
    • /
    • 2013
  • This paper presents a numerical investigation of the influence of the blade back sweep angle on the performance and flow characteristics in a centrifugal compressor with a vaneless diffuser. Five impellers with different back sweep angles were tested in the flow simulations. It was found that a low back sweep angle could improve the total-to-total pressure ratio and the work coefficient over whole operating ranges. However, the flow field in an impeller with a low back sweep angle produced a more non-uniform velocity distribution at the impeller exit because the wake region was significantly increased. As a consequence, the impeller with a low back sweep angle caused a low diffuser performance.

벌집형 소형 태양열 저장수조의 열저장층 내의 온도변화에 관한 실험적 연구 (An Experimental Study on the Temperature Variation in Heat Storage Zone in the Honeycomb-covered Small Saltless Solar Pond)

  • 박이동;황성일;한동균
    • 태양에너지
    • /
    • 제9권1호
    • /
    • pp.30-35
    • /
    • 1989
  • This paper dealt with an experiments on temperature vairation in the heat storage zone due to change of vertical location (height) of sink diffuser and flow extraction in small saltless solar pond ($0.5{\times}0.5{\times}1.0M$), and the honeycomb device for this experimental purpose consisted of one-tired, sealed, and air filled by honeycomb panels. As results of experiments, 1) The storage zone was formed under lower region below the honeycomb device. 2) The higher vertical location of sink diffuser was placed, the more mixing phenomenon increased in the pond at steady flow extraction. 3) The more flow extraction increased, the more mixing phenomenon decreased at constant heat exchanger and variable flow extraction.

  • PDF

TEIS 모델과 두 영역 모델을 이용한 원심 펌프의 탈 설계 성능 예측 (Off-design Performance Prediction of Centrifugal Pumps by Using TEIS model and Two-zone model)

  • 윤인호;백제현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.574-579
    • /
    • 2000
  • In this study. an off-design performance prediction program for centrifugal pumps is developed. To estimate the losses in an impeller flow passage, two-zone model and two-element in series(TEIS) model are used. At impeller exit. the mixing process occurs with an increase in entropy. In two-zone model. there are both primary zone and secondary zone for an isentropic core flow and an average of all non-isentropic streamtubes respectively. The level of the core flow diffusion in an impeller was calculated by using TEIS model. While internal losses in an impeller an automatically estimated by using the above models, some empirical correlations far estimating external losses. far example, disk friction loss, recirculation loss and leakage loss are used. In order to analyze the vaneless diffuser flow. the momentum equations for the radial and tangential directions are used and solved together with continuity and energy equations.

  • PDF

수치 모델에 따른 압전 구동방식 마이크로 펌프의 유동특성에 관한 연구 (A Study on the Flow Characteristics of Piezoelectric Micropumps with Different Numerical Models)

  • 정진;김동희;김창녕
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.707-713
    • /
    • 2004
  • A numerical analysis has been conducted for flow characteristics of piezoelectric micropumps. In the present study, FSI (Fluid-Structure Interaction) model and grid deform model have been employed for each of two different geometries of the micropumps with two different frequencies in the piezoelectric diffuser/nozzle based micropumps. The displacement of piezo disk and flow rates have been closely examined at the inlet and outlet. It has been found that the motion of the piezo disk investigated with FSI model is not in accordance with that with grid deform model. The results show that the time averaged flow rate calculated with FSI model is larger than that with grid deform model. This study presents the performance analysis of piezoelectric micropumps with two different numerical models for different types of pumps.