• 제목/요약/키워드: Diffuser flow

검색결과 425건 처리시간 0.024초

Off-gas Analyzer를 이용한 하수처리장 단일선회류 방식 포기시스템 산소전달 효율의 평가 (Oxygen Transfer Efficiencies of A Single Spiral Roll Aeration System by the Off-gas Method)

  • 박보화;고광백;박재한;임세호;신동록;윤혜정;이지영;문태훈
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.534-539
    • /
    • 2006
  • The supply of oxygen for aeration is the largest energy consumer at activated sludge wastewater treatment plants. Replacement of less efficient aeration systems with fine pore aeration devices can save up to 50 percent of aeration energy costs. The purpose of this study was the diagnosis and evaluation of a domestic wastewater aeration system by the off-gas method which had been studied by US EPA and ASCE. For this study, an off-gas analyzer and its hood were made to collect off-gas. Also, a vacuum pump was connected to the analyzer to make suction of off-gas. Experiments were conducted at a domestic activated sludge wastewater treatment plant which had a single spiral roll aeration system installed with P.E tube diffuser. Data on OTE(f), SOTE(pw), OUR, and air flow rate were obtained from these experiments. In case of replacing an aeration system, it is recommended that it should be replaced with perforated membrane disc or ceramic disc fine bubble diffusers installed in a full floor coverage or grid pattern.

The design of an ejector type microbubble generator for aeration tanks

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Membrane and Water Treatment
    • /
    • 제10권4호
    • /
    • pp.307-311
    • /
    • 2019
  • The ejector type microbubble generator, which is the method to supply air to water by using cavitation in the nozzle, does not require any air supplier so it is an effective and economical. Also, the distribution of the size of bubbles is diverse. Especially, the size of bubbles is smaller than the bubbles from a conventional air diffuser and bigger than the bubbles from a pressurized dissolution type microbubble generator so it could be applied to the aeration tank for wastewater treatment. However, the performance of the ejector type microbubble generator was affected by hydraulic pressure and MLSS(Mixed Liquor Suspended Solid) concentration so many factors should be considered to apply the generator to aeration tank. Therefore, this study was performed to verify effects of hydraulic pressure and MLSS concentration on oxygen transfer of the ejector type microbubble generator. In the tests, the quantity of sucked air in the nozzle, dissolved oxygen(DO) concentration, oxygen uptake rate(OUR), oxygen transfer coefficient were measured and calculated by using experimental results. In case of the MLSS, the experiments were performed in the condition of MLSS concentration of 0, 2,000, 4,000, 8,000 mg/L. The hydraulic pressure was considered up to $2.0mH_2O$. In the results of experiments, oxygen transfer coefficient was decreased with the increase of MLSS concentration and hydraulic pressure due to the increased viscosity and density of wastewater and decreased air flow rate. Also, by using statistical analysis, when the ejector type microbubble generator was used to supply air to wasterwater, the model equation of DO concentration was suggested to predict DO concentration in wastewater.

시화호 인공습지의 수질정화기능 향상을 위한 사례연구 (Case Study on the Improvement of Pollutant Removal Efficiency in Sihwa Constructed Wetland)

  • 최돈혁;강호;최광순
    • 한국습지학회지
    • /
    • 제12권2호
    • /
    • pp.25-33
    • /
    • 2010
  • 본 연구에서는 국내 최대 인공습지인 시화호 인공습지에서 수질정화기능 향상을 위해 수립된 3개의 방안 (물 흐름 개선방안, 혐기성환경 개선을 위한 산소공급장치 설치방안, 탁도유발 물고기 제어방안)에 대한 효율평가 및 습지의 적용성을 제시하였다. 인공습지 하류구역(가로 122m${\times}$세로 103m)에 설치한 물 흐름 유도시설에 의한 BOD, SS, TN, TP의 평균 제거효율은 12.8~7.4%로 나타났으며, BOD가 가장 높은 제거효율을 보였다. 이는 습지내 물흐름이 수질정화기능 향상에 매우 중요하며, 시화호 인공습지와 같이 규모가 큰 습지의 경우 유출부의 일부 구간에 물 흐름 개선만으로도 습지의 수질정화기능을 향상시킬 수 있음을 시사한다. 산소공급장치 가동 후 DO농도 증가율이 산기식폭기장치에서 15.5%과 표면폭기장치에서 37.2%를 보였고, 습지내 DO 농도가 낮은 구역에 한하여 새벽시간에 운영하는 것이 효율적인 것으로 사료된다. 그리고 물고기를 포획을 한 실험군과 대조군의 평균 탁도가 6.2 NTU와 10.6 NTU로 물고기 포획에 의해 41.5%의 탁도 제거효율을 보였다. 습지내 어류현황과 하류부의 탁도에 대한 지속적인 모니터링을 통한 체계적인 어류관리 방안이 필요할 것으로 본다.

원주방향 볼류트 입구 높이를 수정한 자동차용 터보차저 원심압축기의 성능 향상 (Enhancement of the Performance a Centrifugal Compressor in an Automobile Turbocharger by Modifying the Circumferential Inlet Height of Volute)

  • ;이근식
    • 대한기계학회논문집B
    • /
    • 제38권2호
    • /
    • pp.115-120
    • /
    • 2014
  • 자동차용 터보차저 압축기의 성능 개선을 위해 원주방향의 볼류트 입구 높이들이 수정되었고 디퓨저를 포함한 볼류트에 대한 유동장이 상용 소프트웨어를 사용하여 조사되었다. 기본적으로 잘 설계된 볼류트는 높은 압력회복계수와 낮은 전압력손실계수를 보여주어야 한다. 본 연구에서는 동일한 단면형상과 설단면각(Tongue Angle)을 가지나 원주방향으로는 서로 다른 볼류트 입구 높이를 갖는 두 경우의 원형단면 볼류트가 선정되었다. 하나는 $90^{\circ}$ 원주방향에서는 단면 중앙으로 유입되나 이후의 원주방향에서는 볼류트 단면 최하단부들을 잇는 접선과 동일한 높이를 유지하면서 점진적으로 하단부로 유입되는 볼류트 형상이다(케이스 1 볼류트). 다른 하나는 설단면에서는 접선방향으로 유입되도록 모든 원주방향에 대하여 입구 높이를 2 mm 낮춘 형상이다(케이스 2 볼류트). 해석결과, 케이스 2 볼류트가 케이스 1 볼류트보다 높은 압력회복계수로 인한 높은 전압력비와 낮은 전압력손실계수로 인한 높은 등엔트로피 효율을 보여주었다.

전기장에 의해 생성된 미세기포를 이용한 페놀의 오존산화 (Oxidation of Phenol Using Ozone-containing Microbubbles Formed by Electrostatic Spray)

  • 신원태;정유진;성낙창
    • 대한환경공학회지
    • /
    • 제27권12호
    • /
    • pp.1292-1297
    • /
    • 2005
  • 상수나 하수처리장에서 쓰이는 오존처리는 물질전달에 제약을 받는 공정임은 알려져왔다. 이런 물질전달의 한계를 극복하는 방법으로 매우 효과적인 것은 오존가스를 함유한 기포의 크기를 줄임으로써 물질전달에 필요한 접촉면적을 넓히는 것이다. 오존의 전달을 크게 하기 위한 방법으로서 본 연구에서는 전기장분사(Electrostatic spraying: ES)를 사용하였다. 실험에서는 ES와 기포발생판을 비교하였는데 ES실험에서는 전압을 0 kV에서 4 kV 범위까지 높여주어 물질전달효과를 살펴보았고 기공크기가 다른 두 가지 기포발생판(미세기공: 기공크기 $10{\sim}15{\mu}m$, 중간기공: 기공크기 $40{\sim}60{\mu}m$)을 사용하여 물질전달효율을 비교 분석 하였다. 물질전달효율은 시간의 경과에 따른 용존오존농도의 측정과 페놀의 산화시간으로 간접 계산하였다. 실험 결과 ES의 경우 전압을 0 kV에서 4 kV까지 올렸을 때 기포의 크기가 작아짐으로 인해 오존전달율을 약 40% 정도 향상시킬 수 있었다. 또한 ES와 기포발생판의 물질전달 비교실험에서 미세기공 기포발생판보다 4 kV의 ES가 더 효과적임을 알 수 있었다.