• 제목/요약/키워드: Diffuse irradiation

검색결과 55건 처리시간 0.022초

대전지역 직달 및 산란과 전일사 상관계수 (Beam and Diffuse to Global Solar Irradiation Correlation Coefficients for Daejeon)

  • 이관호;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제39권4호
    • /
    • pp.11-24
    • /
    • 2019
  • The total solar irradiation on horizontal surfaces is separated into the beam and diffuses components. Although horizontal global irradiance is a commonly measured parameter for many sites, horizontal diffuse irradiance is not so readily obtainable. For such sites that measure global irradiation alone, a simple but reasonably accurate method is required to estimate diffuse irradiance from its global counterpart. This study investigates the applicability of correlation coefficients models correlating hourly diffuse and beam fraction and hourly clearness index in Daejeon. The three diffuse to global correlation coefficients models (Orgill and Holland model, CIBSE Guide J model, and Erbs et al. model) are selected and the three modified beam to global correlation coefficients models are generated. MBE, RMSE, r-squared of Daejeon and Daejeon boundary site-fitted models are compared with the case of original coefficients. The comparison result shows that the beam and diffuse to global solar irradiation correlation coefficients models with boundary site-fitted coefficients are best suitable for Daejeon. Further researches will be conducted to find the boundary site-fitting method using measured data of other cities and correlation coefficients models using solar altitude, cloud cover, and sunshine duration.

진공관형 태양열 집열기의 흡수관 형상 변화에 따른 성능 비교 (Performance comparisons of the glass evacuated tube solar collectors of different absorber tubes)

  • 김용;서태범;윤성은;김영민
    • 신재생에너지
    • /
    • 제2권1호
    • /
    • pp.56-65
    • /
    • 2006
  • The thermal performance of glass evacuated tube solar collectors are numerically and experimentally investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are compared. Dealing with a single collector tube, the effects of not only the shapes of the absorber tube but also the incidence angle of solar irradiation (beam irradiation) on thermal performance of the collector are studied. However, the solar irradiation consists of the beam irradiation as well as the diffuse irradiation. Also, the interference of solar irradiation and heat transfer interaction between the tubes exist in an actual solar collector, These effects are considered in this study experimentally and numerically. The accuracy of the numerical model is verified by the experimental results. The result shows that the thermal performance of the absorber used a plate fin and U-tube is the best.

  • PDF

진공관형 태양열 집열기의 내부형상 변화에 따른 성능 비교 (Thermal performance comparisons of the glass evacuated tube solar collectors of different absorber tubes)

  • 김용;서태범;윤성은;김영민
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.595-598
    • /
    • 2005
  • The thermal performance of glass evacuated tube solar collectors are numerically and experimentally investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are compared. Dealing with a single collector tube, the effects of not only the shapes of the absorber tube but also the incidence angle of solar irradiation (beam radiation) on thermal performance of the collector are studied. However the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, the interference of solar irradiation and heat transfer interaction between the tubes exist in an actual solar collector. These effects are considered in this study experimentally and numerically the accuracy of the numerical model is verified by the experimental results. The result shows that the thermal performance of the absorber used a plate fin and U-tube is the best.

  • PDF

Malignant Brain Tumours in Children : Present and Future Perspectives

  • Rutka, James T.
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권3호
    • /
    • pp.402-406
    • /
    • 2018
  • In contrast to many of the malignant tumors that occur in the central nervous system in adults, the management, responses to therapy, and future perspectives of children with malignant lesions of the brain hold considerable promise. Within the past 5 years, remarkable progress has been made with our understanding of the basic biology of the molecular genetics of several pediatric malignant brain tumors including medulloblastoma, ependymoma, atypical teratoid rhabdoid tumour, and high grade glioma/diffuse intrinsic pontine glioma. The recent literature in pediatric neuro-oncology was reviewed, and a summary of the major findings are presented. Meaningful sub-classifications of these tumors have arisen, placing children into discrete categories of disease with requirements for targeted therapy. While the mainstay of therapy these past 30 years has been a combination of central nervous system irradiation and conventional chemotherapy, now with the advent of high resolution genetic mapping, targeted therapies have emerged, and less emphasis is being placed on craniospinal irradiation. In this article, the present and future perspective of pediatric brain malignancy are reviewed in detail. The progress that has been made offers significant hope for the future for patients with these tumours.

흡수관 형상과 일사 각도에 따른 진공관형 태양열 집열기의 성능 변화 (Thermal Performance Variations of Glass Evacuated Tube Solar Collectors Depending on the Absorber Shape and the Incidence Angle of Solar Ray)

  • 김용;서태범;강용혁
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.659-668
    • /
    • 2005
  • The thermal performances of glass evacuated tube solar collectors are numerically investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are numerically investigated. Dealing with only collecting tube, the effects of not only the shape of the absorber tube but also the incidence angle of solar irradiation on the thermal performance of the collector are studied because the energy obtained by the absorber can be varied according to the incidence angle of solar radiation. However, the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, in actual system, the interference of solar irradiation and heat transfer interaction between the tubes should be considered. Therefore, this study considered these effects is carried out experimentally and numerically. The accuracy of the numerical model is verified by experiments. The result shows that the thermal performance of the absorber used a plate fin and U-tube is about $25\%$ better than those of the other models.

피라노미터 실측 일조량을 통한 직산 분리 모델과 경사면 일조량 변환 모델에 관한 연구 (A Research on the Decomposition Model and Transposition Model Using the Measured Pyranometer Irradiation Data)

  • 이상혁;이경수
    • 한국태양에너지학회 논문집
    • /
    • 제38권3호
    • /
    • pp.1-20
    • /
    • 2018
  • It is a very important and fundamental process to know accurately the intensity of the solar energy coming into the installed module considering the tilted angle. Europe and the US commonly use a program called PVsyst to convert the global horizontal irradiation to global irradiation on tilted plane. There are two types of models that PVsyst uses to convert to irradiation on tilted plane. In this paper, Perez model, which is a decomposition model and Perez model, which is a transposition model used in PVsyst, are applied based on global horizontal irradiation and global irradiation on tilted plane measured in a specific area. The comparison of the decomposition model shows the effect of the transpostion model on global irradiation on tilted plane conversion by comparing the ratio of the horizontal diffuse irradiation amount of the Watanabe model which are highly trusted in Asia and the Perez model. The comparison of transposition model confirm the error between the measured data and the calculated value which is applied Perez model to global horizontal irradiation decomposed by Perez model and Watanabe model. Based on the two comparisons, This paper propose a method to confirm the reliability of transposition model and reduce the error when PVsyst is used in Korea.

The Signaling of UV-induced Apoptosis in Melanocytes

  • Kim, Dong-Seok;Kim, Sook--Young;Park, Kyoung-Chan
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.217-220
    • /
    • 2002
  • Ultraviolet B (UVB) radiation may activate or deteriorate cultured human epidermal melanocytes, depending on the doses and culture conditions. In this study, we examined whether apoptosis of melanocytes can be induced by physiologic doses of UVB irradiation. PI staining for DNA condensation and flow cytometric analyses demonstrated the apoptotic cell death of melanocytes after UVB irradiation. The level of p53 and Bax revealed a dose-dependent increase with increasing dose of UVB, but the level of Bcl-2 remained unchanged. Confocal microscopic examination showed that Bax moved trom a diffuse to a punctate distribution after UVB irradiation. However, there were no changes in the pattern of Bcl-2. We next examined the downstream targets of apoptosis. Our results showed that a precursor form of caspase-3 disappeared with increasing doses of UVB. We also observed cleavage of poly(ADP-ribose) polymerase (PARP) after UVB irradiation. In addition, UVB irradiation resulted in a remarkable activation of c-Jun N-terminal kinase (JNK). These results indicate that UVB may induce apoptosis via JNK activation in human melanocytes.

  • PDF

미세먼지 농도가 직산분리 모델의 신뢰성에 미치는 영향에 관한 연구 (A Study on the Effect of Particulate Matter Concentration on the Reliability of Decomposition Model)

  • 이상혁;이경수
    • 한국태양에너지학회 논문집
    • /
    • 제39권4호
    • /
    • pp.55-67
    • /
    • 2019
  • Recently, as the amount of particulate matter blowing from China increases, the domestic air environment is rapidly deteriorating. This pollution of the atmosphere greatly affects the light energy reaching the ground. Particularly, since the light enters the solar cell module in various forms, the amount of input energy of the solar power generation system may be changed depending on the ratio of direct beam irradiation and diffused horizontal irradiation. In this paper, we analyze how the ratio of direct beam component and diffused component on global horizontal irradiation varies with the atmospheric conditions. In addition, the reliability of the regression equation, designed to decompose the global horizontal irradiation into horizontal direct beam irradiation and diffused horizontal irradiation, was verified according to the level of air pollution. So, we derive the most suitable decomposition model for use in domestic climatic conditions in Korea by comparing the ratio of direct and diffuse component on the horizontal which is calculated with Perez model and Watanabe model using the meteorological weather data observed for 14 months. Finally, to reduce the error of the transposition result, we verified the reliability of the decomposition which depends on the atmospheric environment.

태양광 시스템의 계절별 일사량과 전력량 (Irradiation and Power Analysis According to Seasons)

  • 이영;정종철;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.220-220
    • /
    • 2009
  • In case of favourable irradiation conditions, the ratio of irradiation to the total irradiation went up and then the irradiation increased in the area with high angle of inclination. The study showed that on a clear day with the irradiation of more than $800[W/m^2]$, the pattern of alternating current power change in the fixed system was similar with that in the single-axis tracker. On the contrary, in case of unfavourable irradiation conditions, the ratio of diffuse irradiation to the total irradiation went up and then the horizontal irradiation increased. In the demo system, the fixed system, the single-axis tracker and the dual-axis tracker all had low generation power and similar generation pattern with each other. The study showed the generation power varied with the irradiation in the fixed system, while in the single-axis tracker and the dual-axis tracker, the amount of the generation power variation was much more than the irradiation variation. The demo system was operated from 11:00 AM to 2:00 PM for generating power, during which time, 46[%] to 56[%] of the total generation power was produced. In this study. the generation power was increased by 147[%] in the fixed system, by 136[%] in the single-axis tracker, and by 164[%] in the dual-axis tracker, and the pattern of generation power was similar with the generation power variation in the situation where the irradiation increased by 140[%] in the spring with plenty of insolation. The alternating current power was more sensitive to variation of the irradiation than to that of the surface temperature of a module. The variation of the irradiation had a more positive effect on the generation power than the type of array.

  • PDF

태양광 발전시스템의 계절별 일사량과 전력량 분석 (Analysis of Irradiation and Power per Each Seasons of Photovoltaic Systems)

  • 김석곤;황준원;이영;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.43-45
    • /
    • 2009
  • In case of favourable irradiation conditions, the ratio of irradiation to the total irradiation went up and then the irradiation increased in the area with high angle of inclination. The study showed that on a clear day with the irradiation of more than 80$[W/m^2]$, the pattern of alternating current power change in the fixed system was similar with that in the single-axis tracker. On the contrary, in case of unfavourable irradiation conditions, the ratio of diffuse irradiation to the total irradiation went up and then the horizontal irradiation increased. In the demo system, the fixed system, the single-axis tracker and the dual-axis tracker all had low generation power and similar generation pattern with each other. The study showed the generation power varied with the irradiation in the fixed system, while in the single-axis tracker and the dual-axis tracker, the amount of the generation Power variation was much more than the irradiation variation. The demo system was operated from 11:00 AM to 2:00 PM for generating power, during which time, 46[%] to 56[%] of the total generation power was produced. In this study, the generation power was increased by 147[%] in the fixed system, by 136[%] in the single-axis tracker, and by 164[%] in the dual-axis tracker, and the pattern of generation power was similar with the generation power variation in the situation where the irradiation increased by 140[%] in the spring with plenty of insolation. The alternating current power was more sensitive to variation of the irradiation than to that of the surface temperature of a module. The variation of the irradiation had a more positive effect on the generation power than the type of array.

  • PDF