• 제목/요약/키워드: Differential protection

검색결과 215건 처리시간 0.026초

전력용 변압기 보호용 시제품 IED 설계와 개선된 기법의 시험 (Testing of Advanced Relaying and Design of Prototype IED for Power Transformer Protection)

  • 박철원;신명철
    • 전기학회논문지P
    • /
    • 제55권1호
    • /
    • pp.6-12
    • /
    • 2006
  • A popular method used by primary protection for power transformer is current ratio differential relaying (RDR) with 2nd harmonic restraints. In modern power transformer due to the use of low-loss amorphous material, the 2nd harmonic component during inrush is significantly reduced. The higher the capacitance of the high voltage status and underground distribution, the more the differential current includes the 2nd harmonic component during internal fault. Thus the conventional method may not operate properly. This paper proposes an advanced relaying algorithm and the prototype IED hardware design and it's real-time experimental results. To evaluate performance of the proposed algorithm, the study is well constructed power system model including power transformer utilizing the EMTP software and the testing is made through simulation of various cases. The proposed relaying that is well constructed using DSP chip and microprocessor etc. has been developed and the prototype IED has been verified through on-line testing. The results show that an advanced relaying based prototype IED never mis-operated and correctly identified all the faults and that inrushes that are applied.

Agent 기반 변압기의 Sympathetic inrush 판단 방법 (Agent based algorithm for detecting sympathetic inrush of a transformer)

  • 강용철;이병은;박종민;황태근;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.234-235
    • /
    • 2006
  • The protection relay keeps electric power facilities by using signals of the voltage and current which are input and output terminals of each equipment. Each relay performances protection algorithm by using informations of own protecting zone. To prevent the mal-operation in inrush current, established transformer differential protection method uses the second harmonics as blocking signal. This method is not operate at the initial inrush. However, in case of the parallel operation, if the initial inrush is occurred in one transformer which is generated, the sympathetic inrush Is occurred in adjacent transformer. This paper approach the sympathetic inrush detecting algorithm of a transformer based on agent. Proposed algorithm, when inrush current occurred, distinguish sympathetic inrush or not by using differential current of adjacent transformer. This algorithm have the advantage of the distinguishing initial inrush and sympathetic inrush at operation of parallel transformer

  • PDF

Fuzzy Logic Based Relaying Using Flux-differential Current Derivative Cure for Power Transformer Protection

  • 권명현;박철원;서희석;이복구;신명철
    • 한국지능시스템학회논문지
    • /
    • 제8권5호
    • /
    • pp.72-82
    • /
    • 1998
  • Power transformer protective relay should block the tripping during magnetizing imrush and rapidly operate the tripping during internal faults. But traditional approaches maloperate in the case of magnetizing inrush with low second harmonic component and internal faults with high second harmounic component. To enhance the fault detection sensitivities of conventional technuques, flux-differential current derivative curve by fuzzy theory approaches is used. This paper deals with fuzzy logic based protective relaying for power transformer. The proposed fuzzy based relaying algorithm consisits of flux-differential current derivative curve, harmonics restraint, and precentage differential characteristic curv. The proposed relaying was tested with relaying signals obtained from Salford EMTP simulation package and showed a fast and accurate trip operation.

  • PDF

80C196KC를 이용한 변압기 보호 계전기 (Ratio Differential Relay Using 80C196KC Microprocessor for Transformer Protection)

  • 황용연;최창영;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.505-506
    • /
    • 2007
  • A ratio differential relay using 80C196KC microprocessor was developed in this paper. The internal faults, external faults and inrush were simulated by EMTP. The performance of developed relay was verified with software and hardware simulation.

  • PDF

The Intertemporal Enforcement Strategies of Copyright Protection : An Analysis of Information Goods in the Presence of File-Sharing Networks

  • Kim, Jong-Woon
    • Journal of Information Technology Applications and Management
    • /
    • 제16권3호
    • /
    • pp.1-15
    • /
    • 2009
  • The paper analyzes a copyright owning firm's incentive to enforce its copyright in the presence of file-sharing networks. I devise a two-period model where a copyright owner sells two different versions of a creator's information good, and show that the firm's overall profits are enhanced by a strategy of differential inter-temporal enforcement of the copyright protection, compared to strategies of no enforcement or full enforcement in both periods. If the firm enforces no copyright protection in the first period, the low-valuation consumers may make and consume copies that are imperfect substitutes for the original information good. If there is a significant increase in the willingness-to-pay of some low-valuation consumers after they experience the information good, the firm can extract the increased consumer surplus by enforcing a positive level of copyright protection in the second period. Social welfare, however, is maximized in the case of no enforcement.

  • PDF

실시간 사고영역을 표현하는 디지털 보호계전기 개발 (Development of the digital protection relay which displays the trip area in real time)

  • 조철희;이병호;김윤회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.499-500
    • /
    • 2007
  • The existing digital protection relay is continuously growing with an improvement in technology. In this paper, we propose the development of the digital protection relay which displays the trip area in real time. In most of the digital protection relays monitor whether analog signal enters into the pre-determined trip area, but those aren't provide the trip area information for a operator in real time. Therefore, if the digital protection relay continuously displays the trip area in real time, the operator analysis power system status easily. This paper particularly introduces selective ground protective relay and differential protective relay with trip area and presents a method of providing the trip area information to operator in real time.

  • PDF

교류발전기 보호를 위한 고장검출 알고리즘의 비교 분석 (A Comparative Analysis of fault Detection Algorithm for AC Generator Protection)

  • 박철원;신광철;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.75-77
    • /
    • 2007
  • Current percentage differential relaying has been recognized as the principal basis of main protection for stator windings of AC generator. The DWT has merit of obtaining frequency characteristics in time domain. In order to compensate for DFT's defects, we proposed fault detection algorithm using DWT. This paper describes a comparative analysis about conventional DFT-based DFR and advanced DWT-based relaying.

  • PDF

진행파를 이용한 디지탈 송전선 보호계전기 (Digital Differential Relay for Transmission Line Protection Using Travelling Wave)

  • 김성수;박종근;윤만철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.95-97
    • /
    • 1988
  • A method of digital transmission line protection using travelling wave is presented. It is shown that the fault current appears as a difference of two quantities associated with the travelling wave at each terminal. The phasor of these quantities are extracted and transmitted to the other end via communication channel to detect the line fault.

  • PDF

Corrosion Protection Performance of PVDF/PMMA-Blended Coatings by Electrochemical Impedance Method

  • Kim, Yun Hwan;Kwon, Yong Sung;Shon, Min Young;Moon, Myung Jun
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권1호
    • /
    • pp.1-8
    • /
    • 2018
  • The effect of mixing ratio on the corrosion protection of carbon steel coated by a film composed of poly(vinylidene) fluoride (PVDF) and poly(methyl methacrylate) (PMMA) was examined using electrochemical impedance spectroscopy. Surface crystallization behavior and thermal properties of the PVDF/PMMA coated carbon steel were evaluated using polarized optical microscopy and differential scanning calorimetry, respectively. A Maltese cross-pattern spherulite crystal was observed in the PVDF/PMMA coating film, which became more apparent with increasing PVDF content. The highest corrosion protection performance was achieved with 60 wt.% PVDF-coated carbon steel, and delamination and corrosion reactions were observed for 20 wt.% PVDF-coated carbon steel. Further, corrosion protection performance with an amorphous/crystal mixture (PVDF/PMMA, 60/40 (w/w)) was better than those observed in the amorphous domain and the perfect-crystal domain of the PVDF/PMMA blended coating system.

DSP를 이용한 전력용 변압기용 IED의 하드웨어 설계 (Hardware Design of IED using DSP for Power Transformer Protection)

  • 박철원;정연만;하경재;구춘서;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.363-365
    • /
    • 2004
  • This paper proposes a hardware implementation of intelligent electronic device for power transformer protection. And proposes an advanced main protection algorithm by voltage-current trend and flux-differential current slope characteristics. The secondary protection functions include UR, OCGR, OVR, and W etc. The main board of IED is based on the DSP chip TMS32C32 processor The IED was tested with relaying signals obtained for EMTP simulation package.

  • PDF