• 제목/요약/키워드: Differential Apparatus

검색결과 59건 처리시간 0.025초

Degradation Evaluation of Mechanical Property for Modified 9Cr-1Mo Steel by Reversible Permeability

  • Bong, Chung-Jong;Ryu, Kwon-Sang;Nahm, Seung-Hoon;Kim, Eun-Kyu
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.42-45
    • /
    • 2011
  • The present work studies a nondestructive evaluation of the degradation of modified 9Cr-1Mo steel using a magnetic method based on the existence of the peaks of reversible permeability (RP) in the differential magnetization around the coercive force. The apparatus is based on detection of the voltage induced in a coil using a lock-in amplifier tuned to the frequency of the AC perturbing field. Results obtained for the reversible permeability and Vickers hardness on the aged samples showed the peak interval of reversible permeability (PIRP) and Vickers hardness decrease as aging time increased. The correlation between Vickes hardness and the PIRP could be used to evaluate degradation of modified 9Cr-1Mo steel.

Imaging System Science Laboratory

  • Nalcioglu, O.;Cho, Z.H.
    • 대한의용생체공학회:의공학회지
    • /
    • 제4권1호
    • /
    • pp.3-8
    • /
    • 1983
  • Characteristics of the lung inflation and deflation reflexes were measured at various temperatures on the cervical vagi in five anesthetized mongrel dogs. Nerve temperature was maintained at the body temperature, and 2-14˚C with 2˚C apart using a specially designed automated vagal cooling apparatus with an accuracy to within $\pm$ 0.1˚c at each temperature. The inflation reflex was blocked abruptly at 8-10˚C. The deflation reflex started weakened at 14˚C, thereafter showed a gradual blockade with the temperature decreased with a substantial variance among the animals.It was approximately 75% blocked at 2-5˚C. These differences in temperature characteristics made it hard to differentiate the deflation reflex from the inflation reflex. In one animal, however, the inflation reflex was completely blocked with the deflation reflex almost alive at 6-8˚C. This suggests that differential cold blockade of the vagal reflexes can be done only in selected subjects. Furthermore, the fact that these two reflexes were blocked at different temperatures may be due to the differences in the nerve fiber size and the changes in the conduction velocity with temperature.

  • PDF

스트레인 게이지 계측용 차동 증폭기와 A/D 변환기를 이용한 트러스 구조물의 내력 측정 장치 설계 (Design of Load and Strain Measuring Equipment Using Strain Gage, Instrumental Differential Amplifier and A/D Converter in a Truss System)

  • 백태현;이병희
    • 비파괴검사학회지
    • /
    • 제28권2호
    • /
    • pp.217-224
    • /
    • 2008
  • 트러스는 교량이나 건축물 설계 등에 많이 사용되는 구조물로서 기본적인 설계요소이며, 설계자는 이러한 구조물의 원리를 완전히 이해하여 설계에 적용할 수 있어야 한다. 본 논문에서는 트러스 구조물의 힘을 기본역학에서 예측되는 오차범위 이내로 실험법으로 측정할 수 있는 기구설계 방법을 제시하였다. 상용으로 제작된 재래식 변형률 측정 장치는 고가이고 복잡하므로 구조를 이해하기가 어려우므로 본 측정기구에서는 휘트스톤브리지 회로를 적용, 스트레인 게이지 및 A/D 변환기 조립하여 하중과 변형률을 쉽게 측정할 수 있도록 하였다. 제작된 기구를 이용하여 구조물에 하중을 가하여 변형률을 측정하였으며, 측정결과를 이론적으로 예측한 값과 비교하여 실용성을 입증하였다. 이 측정 기구는 저렴한 값으로 제작할 수 있으며, 크기가 작아 탁상에서 교육용 실험 및 실습 장비로 적합할 것으로 사료된다.

다전극 산소 센서를 이용한 고분자 막의 산소 투과도 측정 장치 연구 (A Study on the Apparatus for Measuring Oxygen-Permeability of Membranes with a Multi-Electrode Oxygen Sensor)

  • 정일손;정재칠;김태진
    • 센서학회지
    • /
    • 제21권3호
    • /
    • pp.229-234
    • /
    • 2012
  • The existing permeability measurements based on pressure differential between the polymer membrane that is permeable to measure the amount of oxygen used, but these methods must be kept in a vacuum, and the measurement of the membrane with low permeability in the membrane is too time consuming. In recent years by using electrochemical method polymer membrane currents caused by the amount of oxygen is a measure of how much is used. In this study, apparatus consisting of one anode and six cathodes for multi-oxygen permeability tester used the same number of membranes produced by electrochemical oxygen permeation characteristics. In this study, one silver/silver chloride anode electrochemical method with a hexagonal sensor to put various kinds of polymer membranes with the six oxygen permeability for simultaneous measurement in real-time systems. Six cathodes (Pt), and one of the coil-shaped anode (Ag/AgCl) to form a hexagonal one of the polarographic oxygen sensor in a single measurement system by six sensors. Each sensor for making hexagonal specificity of the sensor to compensate for the conditions obtained in a pure nitrogen gas and pure oxygen gas conditions. With this study, self-developed hexagonal sensor capable of measuring sensors and oxygen permeability tester, for a multi-six different oxygen permeability characteristics of the membrane measured at the same time.

고밀도 폴리에틸렌 분진의 열분해성과 착화에너지 (Pyrolysis Characteristic and Ignition Energy of High-Density Polyethylene Powder)

  • 한우섭;이정석
    • 한국가스학회지
    • /
    • 제18권3호
    • /
    • pp.31-37
    • /
    • 2014
  • 본 연구에서는 자료 제공을 목적으로 국내 분진폭발사고에서와 동일한 고밀도 폴리에틸렌(high-density polyethylene, HDPE ) 분진을 사용하여 열분해성과 착화에너지를 실험적으로 조사하였다. 폭발 민감도를 측정하기 위하여 시차주사열량계(differential scanning calorimeter, DSC), 열중량분석기(thermo-gravimetric analysis, TGA) 및 최소착화에너지(minimum ignition energy, MIE) 측정장치를 사용하였다. HDPE의 체적기준 평균입경은 $61.6{\mu}m$가 얻어졌으나, 입자 크기에 따른 입자 수밀도(particle number density) 분석에서는 $0.4{\sim}4{\mu}m$의 미세 입자가 98% 이상의 비율을 갖는 것으로 나타났다. TGA 및 DSC 측정결과로부터 HDPE는 $380{\sim}490^{\circ}C$의 온도 구간에서 발화가 일어날 수 있음을 알 수 있었고, MIE는 $1200{\sim}1800g/m^3$의 HDPE의 농도 범위에서 1 mJ 이하로 측정되었는데, 이는 입자 수밀도 기준에 따른 $0.4{\sim}4{\mu}m$의 미세 입자의 비율(98 %)이 매우 높았던 것이 원인으로 판단된다.

시그마 델타 변조에 의한 LED 드라이버의 입력 콘트롤러 설계 (Delta Sigma Modulation of Controller Input Signal for the LED Light Driver)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권2호
    • /
    • pp.151-155
    • /
    • 2016
  • 우리는 이 논문에서 ADPCM (adaptive differential pulse code modulation)을 적용함으로써 디밍 콘트롤러를 갖는 LED 드라이버의 설계를 제시한다. ADPCM 장비는 고해상도를 가지고 LED 전류를 정확하게 제어하며, 고조파 전류 펄스의 퍼짐으로 인하여 초래되는 RFI 를 감소시켜 준다. 또한 제어 동작의 정밀도를 높여준다. 이 연구에서 LED에 펄스 전류를 인가함으로써 고효율 에너지의 LED를 제어하는 디지털 제어회로의 설계를 제시한다. 우리가 설계한 LED 전류구동시스템은 디지털 제어 부와 아날로그 SMPS (스위치 모드 파워 서플라이)를 별도로 구현한 두개의 시스템이다. 입력레벨이 0.7 인 경우의 시뮬레이션 결과는 시그마 델타 변조를 하여 얻은 D/A 컨버터의 출력을 나타내었다. 개수가 510 개인 펄스신호의 경우 0.15 % 의 정밀도를 얻을 수 있었다.

2D GENUS TOPOLOGY OF 21-CM DIFFERENTIAL BRIGHTNESS TEMPERATURE DURING COSMIC REIONIZATION

  • Hong, Sungwook E.;Ahn, Kyungjin;Park, Changbom;Kim, Juhan;Iliev, Ilian T.;Mellema, Garrelt
    • 천문학회지
    • /
    • 제47권2호
    • /
    • pp.49-67
    • /
    • 2014
  • A novel method to characterize the topology of the early-universe intergalactic medium during the epoch of cosmic reionization is presented. The 21-cm radiation background from high redshift is analyzed through calculation of the 2-dimensional (2D) genus. The radiative transfer of hydrogen- ionizing photons and ionization-rate equations are calculated in a suite of numerical simulations under various input parameters. The 2D genus is calculated from the mock 21-cm images of high-redshift universe. We construct the 2D genus curve by varying the threshold differential brightness temperature, and compare this to the 2D genus curve of the underlying density field. We find that (1) the 2D genus curve reflects the evolutionary track of cosmic reionization and (2) the 2D genus curve can discriminate between certain reionization scenarios and thus indirectly probe the properties of radiation-sources. Choosing the right beam shape of a radio antenna is found crucial for this analysis. Square Kilometre Array (SKA) is found to be a suitable apparatus for this analysis in terms of sensitivity, even though some deterioration of the data for this purpose is unavoidable under the planned size of the antenna core.

페니토인-${\beta}$-시클로덱스트린 포접 복합체의 좌제에 관한 연구 (Studies on Suppositories of $Phenytoin-{\beta}-Cyclodextrin$ Inclusion Complexes)

  • 차재호;한건
    • Journal of Pharmaceutical Investigation
    • /
    • 제18권1호
    • /
    • pp.15-21
    • /
    • 1988
  • An inclusion complex of phenytoin (PT) with ${\beta}-cyclodextrin\;({\beta}-CyD)$ in molar ratio of 1 : 1 was prepared, and the interaction between host and guest molecules was confirmed by infrared spectrometry, differential scanning calorimetry and X-ray diffractometry. Suppositories were prepared by the fusion method. PT and $PT-{\beta}-CyD$ complex were added to PEG 1540 and Witepsol H-15 under the vigorous stirring at $40^{\circ}C$. Content uniformity was tested for different formulations of the PT suppositories. The release rates were dependent on the K.P. V dissolution apparatus and the dialyzing tubing method. Then, the release rates were increased in the following order: $PT-{\beta}-CyD$ complex in PEG 1540>PT in PEG 1540>$PT-{\beta}-CyD$ complex in Witepsol H-15>PT in Witepsol H-15. The area under the curve and maximum blood concentration after rectal administration were increased in the following order: $PT-{\beta}-CyD$ complex in PEG 1540>PT in PEG 1540>$PT-{\beta}-CyD$ complex in Witepsol H-15>PT in Witepsol-15.

  • PDF

실린더 헤드 스월 측정 및 자동화 방법에 관한 연구 (A Study on Measurement and Automation Method of Cylinder Head Swirl)

  • 이충훈
    • 한국자동차공학회논문집
    • /
    • 제14권1호
    • /
    • pp.92-99
    • /
    • 2006
  • The swirl ratio of a charge in the cylinder was estimated by calculating the ratio of the rotary speed of charge which could be simulated from the rotary speed of paddle in the swirl measurement apparatus, to the engine speed which could be calculated by measuring intake air flow rate. The automation of the swirl ratio measurement for cylinder head was achieved by controling both valve lift in cylinder head and a suction pressure of surge tank using two step-motors. The number of measurement position for calculating mean swirl ratio was varied by adjusting the interval of valve lift. The mean swirl ratio with varying the number of measurement position showed nearly constant value. Two measurement methods for measuring the swirl ratio were compared, one was to control the suction pressure of the surge tank with PID (proportional, integral, differential) mode with by-pass valve controlled by the step motor and the other did not control the surge tank pressure by fixing the by-pass valve. The difference of the mean swirl ratio between the two measurement methods showed nearly constant value with varying the number of measurement position. This means that the w/o PID control method could be preferred to the PID control method which has been used, due to the simpleness of the swirl measurement.

자동신경 냉각장치를 이용한 흡식반사와 호식반사의 온도특성 측정 (Measurements of Temperature Characteristics of The Lung Inflation and Deflation Reflexes Using Automated Vagal Cooling System in Anesthetized Dogs)

  • 송영진;차은종
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권3호
    • /
    • pp.177-184
    • /
    • 1991
  • Characteristics of the lung inflation and deflation reflexes were measured at various temperatrues on the cervical vagi in five anesthetized mongrel dogs. Nerve temperature was maintained at the body temperature, and $2-14^{\circ}C$ with $2^{\circ}C$ apart using a specially designed automated vagal cooling apparatus with an accuracy to within ${\pm}0.1^{\circ}C$ at each temperature. The inflation reflex was blocked abruptly at $8-10^{\circ}C$. The deflation reflex started weakened at $14^{\circ}C$, thereafter showed a gradual blockade with the temperature decreased with a substantial variance among the animals. It was approximately 75% blocked at $2-6^{\circ}C$. These differences in temperature characteristics made it hard to differentiate the deflation reflex from the inflation reflex. In one animal, however, the inflation reflex was completely blocked with the deflation reflex almost alive at $6-8^{\circ}C$. This suegests that differential cold blockade of the vagal reflexes can be done only in selected subjects. Fur- thermore, the fact that these two reflexes were blocked at different temperatures may be due to the differences in the nerve fiber size and the changes in the conduction velocity with temperature.

  • PDF