• 제목/요약/키워드: Differential Apparatus

검색결과 59건 처리시간 0.025초

평판형 ER-Valve의 제작 및 성능실험 (Design and Performance Test of Plate Type ER-Valve)

  • 장성철;염만오
    • 한국공작기계학회논문집
    • /
    • 제12권6호
    • /
    • pp.29-35
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-valves are measured with varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. If we allow the same electric field in the ER-Valve, we came to how that the pressure drop is effected by the electrode length and electrode width. When the strength of the electric field increased, the pressure drop happened big and the flow rate decreased.

다공질매체내의 유체유동 특성에 관한 연구 (A Study on the Liquid Flow Characteristics in Layer Porous Media)

  • 이충구;황춘복
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.243-248
    • /
    • 1993
  • In this research, unsteady groundwater flow in unconfined and homogeneous three layer aquifers is studied theoretically and experimentally. Numerical solutions are obtained by Runge Kutta and Runge Kutta Gill method after transforming the governing nonlinear partial differential equations to nonlinear ordinary differential equations. Experimental apparatus includes a test section filled with fine, medium and coarse sands. Experimental results are compared with the numerical solutions and both experimental and numerical results correspond well with each other. This numerical approach may be also applied to the cases which have more aquifers.

  • PDF

PCM의 잠열측정을 위한 T-history법에 대한 고찰 (Consideration on the T-history Method for Measuring Heat of Fusion of Phase Change Materials)

  • 박창현;최주환;홍희기
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1223-1229
    • /
    • 2001
  • Though conventional calorimetry methods such as differential scanning calorimetry (DSC) and differential thermal analysis (DTA) are used generally in measuring heat of fusion, T-history method has the advantages of a simple experimental apparatus and no requirements of sampling process, which is particularly useful for measuring thermal properties of inhomogeneous phase change materials (PCMs) in sealed tubes. However, random criteria (a degree of supercooling) used in selecting the range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion. In the present study, it was shown that a 40% discrepancy exists between the original T-history and the present methods when analyzing the same experimental data. As a result, a reasonable modification to the original T-history method is proposed.

  • PDF

Improvement of the T-history Method to Measure Heat of Fusion for Phase Change Materials

  • Hong, Hi-Ki;Park, Chang-Hyun;Choi, Ju-Hwan;Peek, Jong-Hyeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권1호
    • /
    • pp.32-39
    • /
    • 2003
  • Though conventional calorimetry methods such as differential scanning calorimetry and differential thermal analysis are used generally in measuring heat of fusion, T-history method has advantages of a simple experimental apparatus and no requirements of sampling process, which is particularly useful for measuring thermophyical properties of in-homogeneous phase change materials in sealed tubes. However, the degree of supercooling used in selecting a range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion. In the present study, it was shown that a 40% discrepancy exists between the original T-history and the present methods when analyzing the same experimental data. As a result, a reasonable modification to the original T-history method is proposed.

Effects of Six Antibiotics on the Activity of the Photosynthetic Apparatus and Ammonium Uptake of Thallus of Porphyra yezoensis

  • Oh, Min-Hyuk;Kang, Yun-Hee;Lee, Choon-Hwan;Chung, Ik-Kyo
    • ALGAE
    • /
    • 제20권2호
    • /
    • pp.121-125
    • /
    • 2005
  • The modern integrated fish-seaweed mariculture has been tested to reduce the environmental impacts of an intensive fed culture. To obtain the best seaweed bioremediation performance, the effects of therapeutants used for fish disease control on the selected seaweed species should be considered. As a selected seaweed, Porphyra yezoensis was tested with six commercial antibiotics including erythromycin thiocyanate_A, erythromycin thiocyanate_B, oxytetracycline, doxycycline, pefloxacin, and amoxicillin trihydrate under the batch incubation at a photon flux density of 10 $\mu$mol ${\cdot}m^{-2}\;{\cdot}\;s^{-1}$ at 15$^{\circ}C$. Among the tested commercial antibiotics, erythromycin thiocyanate_A, erythromycin thiocyanate_B, oxytetracycline, and doxycycline showed decreases in Fv/Fm, the photochemical efficiency of photosystem II, with a dose-dependant and time-dependant manner. From the quenching analysis of chlorophyll fluorescence, three differential patterns were observed in the antibiotics-treated Porphyra: (1) high nonphotochemical quenching (NPQ) and low photochemical quenching (qP) in the cases of Erythromycin thiocyanate_B and amoxicillin trihydrate, (2) high NPQ and high qP in the case of pefloxacin and (3) low NPQ and low qP in the case of oxytetracycline. These results indicated that antibiotics affected in various ways on the photosynthetic apparatus, reflecting differential lesion sites of antibiotics. In addition, the rates of ammonium uptake also decreased with a decrease of Fv/Fm in P. yezoensis thalli treated with erythromycin thiocyanate_B and oxytetracycline. Therefore, the four antibiotics mentioned could affect the bioremediation capacity of the selected seaweed species in the integrated fish-seaweed mariculture system due to the decrease of photosynthetic activity and the simultaneous decrease of ammonium uptake.

IEEE-1394카메라와 스텝모터를 이용한 엔진 실린더헤드의 흡기포트 스월 측정 자동화에 관한 연구 (A Study on the Automatic Measurement of Swirl Generated fi:om Intake Port of Engine Cylinder Head Using an I-IEEE-1394 Camera and Step Motors)

  • 이충훈
    • 한국공작기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.88-94
    • /
    • 2005
  • A swirl ratio of a charge in the cylinder could be calculated by measuring both the rotary speed of paddle and the intake air flow rate in the swirl measurement apparatus fur several positions of valve lift. The automation of the swirl ratio measurement for a cylinder head is achieved by controlling both the valve lift of cylinder head and a suction pressure of the surge tank, instead of controlling them manually. PID control of the surge tank pressure and positioning a valve lift of the cylinder head are also achieved by using two step motors, respectively. Rotating speed of a paddle are measured using an optical sensor and a counter. Flow rate are measured from ISA 1932 flow nozzle by reading a differential pressure gauge position using IEEE-1394 camera. Time to measure the swirl ratio for a port in the cylinder head is drastically reduced from an hour to 3 minutes by automation control of the apparatus.

천연섬유분진의 연소특성에 관한 연구 (A Study on Combusiton Properties of Natural Fiber Dust)

  • 이창우;김정환;현성호
    • 한국화재소방학회논문지
    • /
    • 제13권1호
    • /
    • pp.3-10
    • /
    • 1999
  • 천연섬유분진의 연소특성을 조사하고자 국내 방적공장의 집진기에서 직접 포집된 천연섬유분진을 열시차 및 열중량 분석기를 이용하여 온도에 따른 분해 특성을 조사하였고, 자연발화 시험기를 이용하여 시료의 입도분포 및 시료량에 따른 천연섬유의 연소특성을 시간에 따른 온도의 변화로 측정하였다. 또한 자연발화 시험기 내부의 공기흐름에 따른 연소특성을 조사하고자 송풍과 무풍 상태에서의 자연발화 또는 훈소특성을 조사하였다. 열분석 결과 승온속도가 증가할수록 발열개시온도가 현저히 낮았고 발열량도 크게 증가하였다. 또한, 천연섬유 분진은 시료량과 입도가 증가할수록 발열개시온도가 낮아지고 있으며, 연소형태는 모두 훈소 상태를 보였다. 시험기 내부가 송풍상태일 때 보다 무풍상태로 실험하였을 때 발열개시온도가 약간 낮으며, 발열량도 크게 나타났다.

  • PDF

기계식 부압발생장치를 이용한 매연여과장치의 성능비교 (Performance Comparison of Soot Filtration Apparatus Using a Mechanical Negative Pressure Generating Device)

  • 이한성;김경현;정석호;고대권
    • 동력기계공학회지
    • /
    • 제19권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Over the past years, many research works have been carried out to investigate the factors which govern the performance of diesel engines. The air pollutant emissions from the diesel engines are still significant concerns environmentally in many countries. In the present study, a novel smoke filtration system of diesel engine is proposed. This novel system is composed of filtering elements and vacuum pump driven by exhaust gases emitted from engine cylinders for capturing smoke. In order to verify the excellency of the novel filtration system, the differential pressure across the filtration system is investigated experimentally comparing with other systems which are used commercially in diesel vehicles. As a result it is founded that the differential pressure of the novel system is the smallest among them.

아이스슬러리의 분기관내 압력손실과 IPF 변화에 관한 실험적 연구 (Experimental Study on Transformation of IPF and Pressure Drop in Branches with Ice Slurry)

  • 박기원;최현웅;노건상;정재천
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권2호
    • /
    • pp.272-279
    • /
    • 2003
  • This study aimed to understand the effects of transporting ice slurry Particles through Pipes with branches. The experimental apparatus was constructed as ice slurry mixing tank. vortex pump, manometers for differential pressure measuring. IPF(ice packing factor) measuring instruments and branches as test sections. The experiments were carried out under various conditions. with concentration of water solution ranging between 0∼20wt% and velocity of water solution at the entry ranging between 1.5∼2.5m/s. The differential Pressure and IPF between the pipe entry and exit were measured. and flowing form was checked throughout the experiment. The pressure loss in 3d branches appeared compared with 6d branches so that it was very high. In the pressure loss of the inside and outside of branches. 6d branches was showed the difference. but was agreed in 3d branches The pressure loss according to concentration of water solution, low value appeared at 10wt% in 6d branches, at 20wt% in 3d branches. The pressure loss according to velocity, did not show large difference. The change of IPF at outlet, appeared +15∼-25% in 6d branches and 0∼-20% in 3d branches. The difference of IPF at the inside and outside of branches. appeared 10∼15% in 6d branches and maximum 5% in 3d branches.

2D genus topology of 21-cm differential brightness temperature during cosmic reionization

  • Ahn, Kyung-Jin;Hong, Sungwook E.;Park, Chang-Bom;Kim, Uu-Han;Iliev, Ilian T.;Mellema, Garrelt
    • 천문학회보
    • /
    • 제35권2호
    • /
    • pp.43.1-43.1
    • /
    • 2010
  • A novel method to characterize the topology of the early-universe intergalactic medium during the epoch of cosmic reionization is presented. The 21-cm radiation background from high redshift is analyzed through calculation of the 2-dimensional (2D) genus. The radiative transfer of hydrogen-ionizing photons and ionization-rate equations are calculated in a suite of numerical simulations under various input parameters. The 2D genus is calculated from the mock 21-cm images of high-redshift universe. We construct the 2D genus curve by varying the threshold differential brightness temperature, and compare this to the 2D genus curve of the underlying density field. We find that (1) the 2D genus curve reflects the evolutionary track of cosmic reionization and (2) the 2D genus curve can discriminate between certain reionization scenarios and thus indirectly probe the properties of radiation-sources. Choosing the right beam shape of a radio antenna is found crucial for this analysis. Square Kilometer Array (SKA) is found to be a suitable apparatus for this analysis in terms of sensitivity, even though some deterioration of the data for this purpose is unavoidable under the planned size of the antenna core.

  • PDF