• Title/Summary/Keyword: Different thickness and materials

Search Result 1,215, Processing Time 0.034 seconds

Rolling Process Automation For Uniform Thickness of Dough Sheet of Ramen Noddles (라면 면대의 균일한 두께를 위한 압연공정 자동화)

  • Yoo, Dong-Sang;Yoo, Byung-Kook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.11
    • /
    • pp.97-103
    • /
    • 2012
  • The basic processing unit for instant ramen noodles includes mixing, rolling, boiling, frying, cooling, and packing processes. For uniform thickness of dough sheets in rolling process, the roll-gap in rolling process needs to keep uniform thickness of flour sheets in spite of different kinds of raw materials. In this paper, we have developed a roll gap adjustment system using a PLC (Programmable Logic Controller) with a touch panel and an AC servo-mechanism to make dough sheets with a good gluten starch-network structure and uniform thickness and to contribute to process standardization by transferring from tacit knowledge of skilled workers to explicit knowledge. The developed system can adjust the roll gap in units of 0.01mm and correspond to various product items which have different thickness specification by recalling the presetting values of the desired thickness from database.

Vertical In-Line Machine Concept for OLED Manufacturing

  • Hoffmann, U.;Campo, M.;Bender, M.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.742-745
    • /
    • 2004
  • A profitable mass production of Organic Light Emitting Diode (OLED) displays needs a new type of manufacturing equipment. We have developed a vertical In-Line machine (VES400) equipped with linear etch sources (e.g. to activate an ITO layer), standard magnetron sputter sources for ITO and metal and linear evaporation sources for the organic and metal materials. We present new results concerning the linear evaporation sources for organic materials. We have optimized the vertical thickness non uniformity for the evaporation of different organic materials and achieved deviations of less than ${\pm}$ 5 % for the vertical thickness over a substrate height of 400 mm. We will further report first results about the long term stability of the deposition rate for different organic materials using rate control..

  • PDF

A Study on Fatigue Fracture Behavior of Laser Beam Welding and Steel with Different Materials ($CO_2$ 레이저 용접 이종재료강의 피로파괴거동에 관한 연구)

  • Han, M.S.;Suh, J.;Lee, J.H.;Kim, J.O.;Jeon, S.M.
    • Laser Solutions
    • /
    • v.9 no.2
    • /
    • pp.1-9
    • /
    • 2006
  • In this paper, we investigated the characteristics of fatigue fracture on TB(Tailored Blank) weldment by comparing the fatigue crack propagation characteristics of base metal with those of TB welded sheet used for vehicle body panels. We also investigated the influence of center crack on the fatigue characteristic of laser weld sheet of same thickness. We conducted an experiment on fatigue crack propagation on the base metal specimen of 1.2mm thickness of cold-rolled metal sheet(SPCSD) and 2.0mm thickness of hot-rolled metal sheet(SAPH440) and 1.2+2.0mm TB specimen. We also made an experiment on fatigue crack propagation on 2.0+2.0mm and 1.2+1.2mm thickness TB specimen which had center crack. The characteristics of fatigue crack growth on the base metal were different from those on 1.2+2.0mm thickness TB specimen. The fatigue crack growth rate of the TB welded specimens is slower in low stress intensity factor range $({\Delta}K)$ region and faster in high${\Delta}K$ region than that of the base metal specimens. The slant crack angle slightly influenced the crack propagation of the TB specimen of 2.0+2.0mm thinkness.

  • PDF

Comparison of light transmittance in different thicknesses of zirconia under various light curing units

  • Cekic-Nagas, Isil;Egilmez, Ferhan;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.93-96
    • /
    • 2012
  • PURPOSE. The objective of this study was to compare the light transmittance of zirconia in different thicknesses using various light curing units. MATERIALS AND METHODS. A total of 21 disc-shaped zirconia specimens (5 mm in diameter) in different thicknesses (0.3, 0.5 and 0.8 mm) were prepared. The light transmittance of the specimens under three different light-curing units (quartz tungsten halogen, light-emitting diodes and plasma arc) was compared by using a hand-held radiometer. Statistical significance was determined using two-way ANOVA (${\alpha}$=.05). RESULTS. ANOVA revealed that thickness of zirconia and light curing unit had significant effects on light transmittance ($P$ <.001). CONCLUSION. Greater thickness of zirconia results in lower light transmittance. Light-emitting diodes light-curing units might be considered as effective as Plasma arc light-curing units or more effective than Quartz-tungsten-halogen light-curing units for polymerization of the resin-based materials.

Analysis of press formability of laser-welded blank(II) (레이저 용접 소재의 프레스 성형특성 해석(II))

  • 하동호;김영석
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.55-58
    • /
    • 1997
  • In automotive industries, stamping of laser-welded blank gives many merits which brings about dimensional accuracy, strong body assembly and high productivity. However the welding of blanks with different thickness or/and different strength materials introduces many challenging formability problems for process development and tool design. In this paper, the deformation characteristics for deep drawing process of laser-welded blank with different thickness sheets are investigated by experiment and FEM simulation. And also the optimal location of weld line in laser-welded blank with different thickness sheets is calculated to compensate for the movement of weld line on deep drawing process. In addition, the effect of location of weld line is clarified using FEM simulation.

  • PDF

A Design of the Thickness Gauge Using the Compton Gamma-ray Backscattering

  • B.S. Moon;Kim, Y.K.;Kim, J.Y.;Kim, J.T.;C.E. Chung;S.B. Hong
    • Nuclear Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.457-464
    • /
    • 2000
  • In this paper, we describe the results of various calculations performed for a design of the thickness gauges that use the gamma-ray backscattering method. The radiation source is assumed to be the $_{24}$1Am(60keV gamma-ray) and the detector is a single crystal scintillator in a cylindrical form. The source is located at the center of the detector with the collimator of a cylindrical shape. First, when gamma-rays are incident on a material with a constant angle, we compute the variations of the spectrum for the photons scattered into different angular intervals. Next, we compute for an optimal size for the collimator cylinder for a fixed detector size and an optimal distance from the detector to the material. Finally, we compute the number of observed photons for different thickness of two different materials, a plastic film and an Al foil.

  • PDF

Thermal buckling of FGM beams having parabolic thickness variation and temperature dependent materials

  • Arioui, Othman;Belakhdar, Khalil;Kaci, Abdelhakim;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • v.27 no.6
    • /
    • pp.777-788
    • /
    • 2018
  • An investigation on the thermal buckling resistance of simply supported FGM beams having parabolic-concave thickness variation and temperature dependent material properties is presented in this paper. An analytical formulation based on the first order beam theory is derived and the governing differential equation of thermal stability is solved numerically using finite difference method. a function of thickness variation is introduced which controls the parabolic variation intensity of the beam thickness without changing its original material volume. The results showed the high importance of taking into account the temperature-dependent material properties in the thermal buckling analysis of such critical beam sections. Different Influencing parametric on the thermal stability are studied which may help in design guidelines of such complex structures.

The Effect of Thicknesses on Magnetic Properties of Fe-Hf-N Soft Magnetic Thin Films (Fe-Hf-N 연자성 박막의 자기적 특성에 미치는 박막 두께의 영향)

  • Choi, Jong-Won;Kang, Kae-Myung
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.6
    • /
    • pp.255-259
    • /
    • 2011
  • The thickness dependence of magnetic properties was experimentally investigated in nanocrystalline Fe-Hf-N thin films fabricated by a RF magnetron sputtering method. In order to investigate the thickness effect on their magnetic properties, the films are prepared with different thickness ranges from 90 nm to 330 nm. It was revealed that the coercivity of the thin film increased with film thickness. On the contrary, the saturation magnetization decreased with film thickness. On the basis of the SEM and TEM, an amorphous phase forms during initial growth stage and it changes to crystalline structure after heat treatment at $550^{\circ}C$. Nanocrystalline Fe-Hf-N particles are also generated.

Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An in vitro study

  • Palone, Mario;Longo, Mattia;Arveda, Niki;Nacucchi, Michele;De Pascalis, Fabio;Spedicato, Giorgio Alfredo;Siciliani, Giuseppe;Lombardo, Luca
    • The korean journal of orthodontics
    • /
    • v.51 no.2
    • /
    • pp.135-141
    • /
    • 2021
  • Objective: To assess the effects of thermoforming on aligner thickness and gap width in six aligner systems with the same nominal thickness. Methods: Six passive upper aligners of different brands were adapted to a single printed cast. Each sample was evaluated with high-resolution micro-computed tomography. To investigate aligner thickness and gap width, two-dimensional (2D) analysis was conducted assessing the effects of the following variables: tooth type (central incisor, canine, and first molar), 2D reference points, and aligner type. Data were analyzed and compared using analysis of variance and Tukey's post-hoc tests (p < 0.05). Results: Tooth type, dental region, and aligner type affected both the gap width and aligner thickness. The aligner thickness remained moderately stable across the arch only in the F22. Conclusions: All thermoformed samples displayed smaller aligner thickness and gap width at anterior teeth and both gingival and coronal centers than at posterior teeth and occlusal surfaces.