Effects of Use of the Iodine Contrast Medium on Gamma Camera Imaging (요오드 조영제 사용이 감마카메라 영상에 미치는 영향)

  • Pyo, Sung-Jae;Cho, Yun-Ho;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.557-564
    • /
    • 2016
  • Effects of Gamma camera imaging on gamma ray counting rates as a function of use and density of the iodine contrast medium currently in primary use for clinics, and changes in gamma ray counting rates as a function of the contrast medium status upon attenuation correction using a CT absorption coefficient in an SPECT/CT attenuation correction will be considered herein. For experimental materials used $^{99m}TcO_4$ 370 MBq and Pamiray 370 mg, Iomeron 350 mg, Visipaque 320 mg, Bonorex 300 mg of iodine contrast medium. For image acquisition, planar imaging was consecutively filmed for 1, 2, 3, 4, 5 min, respectively, 30 min after administration of $^{99m}TcO_4$. while 60 views were filmed per frame for 20 min at 55 min for the SPECT/CT imaging. In planar imaging, the gamma ray counting rates as a function of filming time were reduced showing a statistically significant difference when mixed according to the type of contrast medium density rather than when the radioactive isotope $^{99m}TcO_4$ and the saline solution were mixed. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and saline solution, the mean counting rate without correction by the CT absorption coefficient is $182{\pm}26counts$, while the counting rate with correction by the CT absorption coefficient is $531.3{\pm}34counts$. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and the saline solution with the contrast medium, the mean values before attenuation correction by CT absorption coefficient were $166{\pm}29$, $158.3{\pm}17$, $154{\pm}36$, and $150{\pm}33counts$ depending on the densities of the contrast medium, while the mean values after attenuation correction were $515{\pm}03$, $503{\pm}10$, $496{\pm}31$, and $488.7{\pm}33counts$, showing significant differences in both cases when comparatively evaluated with the imaging for no mixing of the contrast medium. Iodine contrast medium affects the rate of gamma ray. Therefore, You should always be preceded before another test on the day of dignosis.

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease (관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jeong-Sun;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.

Different $^{18}$F-FDG Uptake According to Tumor location and Morphology of Cholangiocarcinoma and Its Clinical Implication (담관암의 위치와 형태에 따른 $^{18}$F-FDG 섭취량의 차이와 임상적 의의)

  • Lee, Won-Seok;Lee, Yoon-Jae;Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.317-322
    • /
    • 2009
  • Purpose: $^{18}$F-flurodeoxyglucose (FDG) uptake on positron emission tomography (PET) scan has been found to reflect tumor aggressiveness and prognosis in various types of cancer. However, pattern of FDG uptake in biliary malignancies and its clinical significance have not been studied well. The purpose of this study was to assess the additional value of $^{18}$F-FDG PET in differential diagnosis and prognosis of cholangiocarcinoma (CC) according to the tumor location and tumor morphology. Materials and Methods: From April 2005 to May 2008, eighty two patients (M:F = 55:27, age 66.2$\pm$9.6 yrs) with CC underwent $^{18}$F-FDG PET. For semiquantitative analysis, the maximum standardized uptake value (SUV$_{max}$) was obtained from the primary tumor. The difference of SUV$_{max}$ according to the tumor location and tumor growth pattern, such as scirrhous type, nodular type, polypoid type were compared. Results: Overall sensitivity of PET scan was 81.7% in CC. SUV$_{max}$ on PET scan in intrahepatic CC was significantly higher compared to extrahepatic CC. In extrahepatic CC, polypoid type showed significantly higher SUV$_{max}$ compared to scirrhous type. Conclusion: $^{18}$F-FDG PET may have a significant impact on clinical decision-making and on the management of intrahepatic cholangiocarcinoma. And it is related to the shape of the tumor and the sensitivity of detection is higher in the mass-forming type than in the scirrhous type.

Three dimensional analysis of tooth movement using different sizes of NiTi wire on NiTi scissors-bite corrector (NiTi scissors-bite corrector의 와이어 굵기에 따른 3차원적 치아 이동 양상)

  • Jeon, Hyun-Ju;Park, Sun-Hyung;Jung, Sang-Hyuk;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.39 no.1
    • /
    • pp.43-53
    • /
    • 2009
  • Objective: The purpose of this study was to compare the difference in three dimensional tooth movement using three different wire sizes($0.018{\times}0.025-in,\;0.016{\times}0.022-in$ 0.016-in) on a NiTi scissors-bite corrector. Methods: Computed tomography(CT) images of the experimental model before and after tooth movement were taken and reconstructed into three dimensional models for superimposition. The direction and the amount of tooth movement were measured and analyzed statistically. Results: The lingual and intrusive movements of the crown of the maxillary second molar were increased as the size of the NiTi wire increased. The roots of the maxillary second metals moved buccally except for the 0.016-in group. The intrusive movement of the roots of the maxillary second molars was increased as the size of the NiTi wire increased. Due to the use of orthodontic mini-implants, anchorage loss was under 0.2 mm on average. Conclusions: The $0.018{\times}0.025-in$ NiTi wire was most effective in lingual and intrusive movement of the maxillary second molar which was in scissors-bite position. Indirect skeletal anchorage with a single orthodontic mini-implant was rigid enough to prevent anchorage loss.

Airway Responses to Bronchoprovocation Using High-Resolution Computed Tomography in Patients with Bronchial Asthma (기관지천식환자에 있어서 고해상도 전산화단층촬영술을 이용한 기관지유발에 대한 기도의 반응)

  • Choi, Byoung-Whui;Kang, Yoon-Jeong;Ko, Hyung-Ki;Park, In-Won;Hue, Sung-Ho;Kim, Yang-Soo;Kim, Young-Goo;Kim, Kun-Sang;Kim, Jong-Hyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.813-822
    • /
    • 1995
  • Background: Bronchial hyperresponsiveness and abnormal response such as a loss of distensibility are pathophysiologic characteristics if bronchial asthma. The only means of direct in vivo measurement of airway size had been a tantalium bronchography, until high-resolution computed tomography(HRCT) enabled to measure noninvasively two dimensional airway area more accurately and reliably. Method: To investigate airway area responses to bronchial provocation with methacholine and evaluate the major sites of bronchial constriction in patients with bronchial asthma. We examined HRCT scans in five patients with bronchial asthma who had significant bronchoconstriction(20% or more decrease in $FEV_1$) using CT scanner(5,000T CT, Shimadzu Co, Japan) before and in 3~5 min. after methacholine inhalation. Airways which were matched by parenchymal anatomic landmarks in each patient before and after methacholine inhalation were measured using film scanner(TZ-3X scanner; Truvel Co. Chatsworth CA, USA) and a semiautomated region growing method. Results: 1) We identified 9 to 12 airways in each patient which were matched by parenchymal anatomic landmarks before and after methacholine inhalation. 2) Airway responses to methacholine are quite different even in a patient. 3) The constriction of small airways(average diameter <2 mm; area < $3.14mm^2$) was 48.7%(8.3; SEM, n=43), being more prominant than that of large airways(average diameter >2 mm; area > $3.14mm^2$), 53.8% (4.4;SEM, n=10), but not significantly different(p>0.05). 4) There was no significant difference in the degree of constriction between upper(44.3% +5.8; mean + SEM, n=30) and lower lung regions(56.7% +4.5, n=23). Conclusions: Thus airway responses to methacholine bronchoprovocation is quite variable in a patient with bronchial asthma and has no typical pattern in patients with bronchial asthma.

  • PDF

Retrospective study on three-dimensional characteristics of mesiodens using CBCT in pediatric dentistry (치과용 Cone-beam CT를 이용한 상악 정중과잉치의 3차원적 특성에 관한 후향적 연구)

  • Ryu, GiYoun;Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Young-Jae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.77-94
    • /
    • 2021
  • The purpose of this study was to investigate the three-dimensional characteristics of mesiodens using Cone-beam Computed Tomography(CBCT) and analyze the factors affecting complications and anesthetic methods of extraction. This study evaluated 602 mesiodens of 452 patients who underwent extraction of mesiodens at the department of Pediatric Dentistry in Seoul National University Dental Hospital between 2017 and 2019. The ratio of mesiodens patients over total patient per year was gradually increased over the past 20 years. Mesiodens with labio-palatally horizontal direction while root directing labial were the most common among the mesiodens with horizontal direction. Mesiodens were the most common at the cervical side of the adjacent teeth(37.0%) and mesiodens located in the near-palatal side were observed about 3.83 times higher than the far-palatal side. Most of the mesiodens(82.1%) were in contact with adjacent permanent teeth on all three sides of the CBCT and 46.2% of mesiodens had curved roots. The patient's age, vertical position, presence of complications, and proximity showed a significant difference in the selection of general anesthesia among anesthetic methods. The direction and vertical position of mesiodens had a significant effect on complications. These results provide a better understanding of mesiodens for establishing an accurate diagnosis and treatment plan.

The influence of the decision making time by using point-of-care creatinine in patients with acute abdomen (급성 복증 환자에서 현장검사 크레아티닌을 이용한 의사결정 시간의 단축)

  • Choi, Younhyuk;Cho, Sunguk;Ahn, Hongjoon;Min, Jinhong;Jeong, Wonjoon;Ryu, Seung;Oh, Segwang;Kim, Seunghwan;You, Yeonho;Lee, Jinwoong;Park, Jungsoo;Yoo, Insool;Cho, Yongchul
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.663-670
    • /
    • 2018
  • Objective: Radio-contrast abdomino-pelvic computed tomography (APCT) is considered the gold standard diagnostic tool for an acute abdomen in the emergency department. On the other hand, APCT has a risk of contrast-induced nephropathy. Emergency physicians evaluate the creatinine (Cr) level prior to taking a APCT for the above reason but it takes time to evaluation the serum Cr level. This study hypothesized that Cr measured by a point-of-care test (POCT) can shorten the time to making clinically important decisions for patients with an acute abdomen. Methods: This prospective randomized study was conducted between March 2017 and October 2017. The subjects were divided into two groups (Cr measured by laboratory vs. Cr measured by POCT). To analyze the clinical acceptability for creatinine, agreement was demonstrated graphically by Bland-Altman plots. This study compared the time to make a clinically important decision by physicians and the length of stay at the emergency department in both groups. Results: A total of 76 patients were eligible for the study, 38 patients were assigned to each group. There was no statistically significant difference in the time to the first medical examination (P=0.222) and emergency department stay time (P=0.802). On the other hand, the time to recognition of the Cr level (P<0.001), time to performing APCT (P<0.001), time to decision making (P<0.001), and time to initiation of treatment (P<0.001) were shortened significantly in the point-of-care creatinine group. Conclusion: In this study, the POCT for creatinine can allow rapid decision making by shortening the time to performing the radio-contrast APCT than the laboratory for patients with an acute abdomen.

Comparison of capsule type resin modified glass ionomer porosity according to mixing methods (혼합방법에 따른 캡슐형 광중합글라스아이노머의 공극률 비교)

  • Kim, Jung-min;Kim, Jin-Woo;Cho, Kyung-Mo;Lee, Yoon;Kim, Eung-Hyun;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.217-224
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the porosity of resin modified glass ionomer (RMGI) by different mixing methods. Materials and Methods: Five specimens were prepared for each groups according to capsules and mixing methods. Two RMGI capsule and two mixing machines were used for this study. One resin-modified glass ionomer cement is Fuji II LC (F2LC) and the other is Photac Fil Quick Aplicap (PFQ). For Mixing of RMGI capsule, Rotomix using rotating motion and CM-II using shaking motion were used. After measuring height, radius and mass of specimens, Density was calculated. And porosity was measured using micro-computed tomography (micro-CT). All data were statistically analyzed using T-test, two-way ANOVA to compare between groups at 95% significance level to evaluate the affect of capsule and mixing method on the porosity. Results: The porosity was observed in all specimens generally. And there is significant differece between porosities according to RMGI capsule and Mixing method. The porosity of PFQ was lower than that of F2LC and the porosity of Rotomix was lower than that of CM-II. Conclusion: There was a difference of porosity according to kind of capsules and mixing methods. When using same capsule, less porosity was observed on PFQ than F2LC. When using same mixing mehod, less porosity was observed on Rotomix than CM-II. Using mixing machine of same coporation as that of RMGI capsule did not lead to lower porosity. Therefore, Selecting optimal mixing machine is important.

Assessment of the Position of the Mandibular Foramen and Mandibular Lingula in Children and Adolescents using CBCT (소아 청소년에서 하악공 및 하악소설의 위치에 대한 CBCT 분석)

  • Lee, Jihye;Choi, Namki;Kim, Byunggee;Kim, Seonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.64-76
    • /
    • 2021
  • The purpose of this study is to evaluate the position of the mandibular foramen and location and morphological characteristics of the mandibular lingula using Cone-Beam Computed Tomography (CBCT). Mandibular CBCT images of children aged 6 - 16 years were collected. A total of 180 patients were divided into 3 groups, 6 - 7, 10 - 11 and 15 - 16 years, with 30 male and female patients per group. Either side of the ramus was analyzed. The shortest distances from the anterior, posterior, superior and inferior border of the ramus to the mandibular lingula were measured. The shortest distance between the mandibular lingula and the mandibular foramen was also measured. The vertical distance from the mandibular lingula and the mandibular foramen to the occlusal plane was measured. The shapes of the mandibular lingula was classified into 4 types according to the criteria. The distances of the mandibular lingula from the anteroposterior and vertical reference points of the ramus increased in all directions with age. The distance between the mandibular lingula and the mandibular foramen also increased with age. The location of the mandibular lingula and the mandibular foramen in relation to the occlusal plane moved upwards with age. The most common shape of the mandibular lingula was triangular, followed by nodular, truncated and assimilated, and there was no difference in the shape according to age. It is recommended that the horizontal insertion point of the anesthesia from the anterior border of the ramus increased to 17 mm, 18 mm, and 19 mm according to the age groups. It is also suggested that the vertical insertion point increased by 2 - 3 mm, 5 - 6 mm and 9 - 10 mm above the occlusal plane according to the age groups.