• Title/Summary/Keyword: Difference tomography

Search Result 827, Processing Time 0.027 seconds

Rodent peri-implantitis models: a systematic review and meta-analysis of morphological changes

  • Ren Jie Jacob Chew;Jacinta Xiaotong Lu;Yu Fan Sim;Alvin Boon Keng Yeo
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.479-495
    • /
    • 2022
  • Purpose: Rodent models have emerged as an alternative to established larger animal models for peri-implantitis research. However, the construct validity of rodent models is controversial due to a lack of consensus regarding their histological, morphological, and biochemical characteristics. This systematic review sought to validate rodent models by characterizing their morphological changes, particularly marginal bone loss (MBL), a hallmark of peri-implantitis. Methods: This review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. A literature search was performed electronically using MEDLINE (PubMed), and Embase, identifying pre-clinical studies reporting MBL after experimental peri-implantitis induction in rodents. Each study's risk of bias was assessed using the Systematic Review Center for Laboratory animal Experimentation (SYRCLE) risk of bias tool. A meta-analysis was performed for the difference in MBL, comparing healthy implants to those with experimental peri-implantitis. Results: Of the 1,014 unique records retrieved, 23 studies that met the eligibility criteria were included. Peri-implantitis was induced using 4 methods: ligatures, lipopolysaccharide, microbial infection, and titanium particles. Studies presented high to unclear risks of bias. During the osseointegration phase, 11.6% and 6.4%-11.3% of implants inserted in mice and rats, respectively, had failed to osseointegrate. Twelve studies were included in the meta-analysis of the linear MBL measured using micro-computed tomography. Following experimental peri-implantitis, the MBL was estimated to be 0.25 mm (95% confidence interval [CI], 0.14-0.36 mm) in mice and 0.26 mm (95% CI, 0.19-0.34 mm) in rats. The resulting peri-implant MBL was circumferential, consisting of supra- and infrabony components. Conclusions: Experimental peri-implantitis in rodent models results in circumferential MBL, with morphology consistent with the clinical presentation of peri-implantitis. While rodent models are promising, there is still a need to further characterize their healing potentials, standardize experiment protocols, and improve the reporting of results and methodology.

Texture analysis in cone-beam computed tomographic images of medication-related osteonecrosis of the jaw

  • Polyane Mazucatto Queiroz;Karolina Castilho Fardim;Andre Luiz Ferreira Costa;Ricardo Alves Matheus;Sergio Lucio Pereira Castro Lopes
    • Imaging Science in Dentistry
    • /
    • v.53 no.2
    • /
    • pp.109-115
    • /
    • 2023
  • Purpose: The aim of this study was to evaluate changes in the trabecular bone through texture analysis and compare the texture analysis characteristics of different areas in patients with medication-related osteonecrosis of the jaw (MRONJ). Materials and Methods: Cone-beam computed tomographic images of 16 patients diagnosed with MRONJ were used. In sagittal images, 3 regions were chosen: active osteonecrosis(AO); intermediate tissue (IT), which presented a zone of apparently healthy tissue adjacent to the AO area; and healthy bone tissue (HT) (control area). Texture analysis was performed evaluating 7 parameters: secondary angular momentum, contrast, correlation, sum of squares, inverse moment of difference, sum of entropies, and entropy. Data were analyzed using the Kruskal-Wallis test with a significance level of 5%. Results: Comparing the areas of AO, IT, and HT, significant differences (P<0.05) were observed. The IT and AO area images showed higher values for parameters such as contrast, entropy, and secondary angular momentum than the HT area, indicating greater disorder in these tissues. Conclusion: Through texture analysis, changes in the bone pattern could be observed in areas of osteonecrosis. The texture analysis demonstrated that areas visually identified and classified as IT still had necrotic tissue, thereby increasing the accuracy of delimiting the real extension of MRONJ.

Combination of a new ultrasonic tip with rotary systems for the preparation of flattened root canals

  • Karina Ines Medina Carita Tavares ;Jader Camilo Pinto ;Airton Oliveira Santos-Junior ;Fernanda Ferrari Esteves Torres ;Juliane Maria Guerreiro-Tanomaru ;Mario Tanomaru-Filho
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.56.1-56.11
    • /
    • 2021
  • Objectives: This study evaluated 2 nickel-titanium rotary systems and a complementary protocol with an ultrasonic tip and a small-diameter instrument in flattened root canals. Materials and Methods: Thirty-two human maxillary second premolars with flattened canals (buccolingual diameter ≥4 times larger than the mesiodistal diameter) at 9 mm from the radiographic apex were selected. The root canals were prepared by ProDesign Logic (PDL) 30/0.01 and 30/0.05 or Hyflex EDM (HEDM) 10/0.05 and 25/0.08 (n = 16), followed by application of the Flatsonic ultrasonic tip in the cervical and middle thirds and a PDL 25/0.03 file in the apical third (FPDL). The teeth were scanned using micro-computed tomography before and after the procedures. The percentage of volume increase, debris, and uninstrumented surface area were analyzed using the Kruskal-Wallis, Dunn, Wilcoxon, analysis of variance/Tukey, and paired and unpaired t-tests (α = 0.05). Results: No significant difference was found in the volume increase and uninstrumented surface area between PDL and HEDM (p > 0.05). PDL had a higher percentage of debris than HEDM in the middle and apical thirds (p < 0.05). The FPDL protocol resulted in less debris and uninstrumented surface area for PDL and HEDM (p < 0.05). This protocol, with HEDM, reduced debris in the middle and apical thirds and uninstrumented surface area in the apical third (p < 0.05). Conclusions: High percentages of debris and uninstrumented surface area were observed after preparation of flattened root canals. The HEDM, Flatsonic tip, and 25/0.03 instrument protocol enhanced cleaning in flattened root canals.

Shape and anatomical relationship of the mental foramen to the mandibular premolars in an Indian sub-population: a retrospective CBCT analysis

  • Komal Sheth;Kulvinder Singh Banga;Ajinkya M. Pawar;James L. Gutmann;Hyeon-Cheol Kim
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.1.1-1.13
    • /
    • 2022
  • Objectives: This study assessed the shape and anatomical relationship of the mental foramen (MF) to mandibular posterior teeth in an Indian sub-population. Materials and Methods: In total, 475 existing cone-beam computed tomography records exhibiting 950 MFs and including the bilateral presence of mandibular premolars and first molars were assessed. Images were evaluated 3-dimensionally to ascertain the position, shape, and anatomical proximity of MFs to mandibular teeth. The position and shape of MFs were measured and calculated. The Pythagorean theorem was used to calculate the distance between the root apex of the mandibular teeth and the MF. Results: MFs exhibited a predominantly round shape (left: 67% and right: 65%) followed by oval (left: 30% and right: 31%) in both males and females and in different age groups. The root apices of mandibular second premolars (left: 71% and right: 62%) were closest to the MF, followed by distal to the first premolars and mesial to the second premolars. The mean vertical distance between the MF and the nearest tooth apex calculated on sagittal sections was 2.20 mm on the right side and 2.32 mm on the left side; no significant difference was found according to sex or age. The distance between the apices of the teeth and the MF was ≥ 4 mm (left; 4.09 ± 1.27 mm and right; 4.01 ± 1.15 mm). Conclusions: These findings highlight the need for clinicians to be aware of the location of the MF in treatment planning and while performing non-surgical and surgical endodontic procedures.

Proximity of maxillary molar apexes to the cortical bone surface and the maxillary sinus

  • Han Shin Lee;Dokyung Kim;Sung Kyo Kim
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.3
    • /
    • pp.33.1-33.10
    • /
    • 2022
  • Objectives: This study aimed to analyze the proximity of maxillary molar roots to their overlying cortical bone surfaces and the maxillary sinus. Materials and Methods: Cone-beam computed tomographic images of 151 patients with completely erupted upper molars that had 3 separate roots were studied. The following distances were measured: from the root apex to the cortical plate and maxillary sinus floor, and from the apical 3-mm level of the root to the cortical plate. Differences between groups were analyzed with 1-way analysis of variance and the Scheffé post hoc test, the significance of differences between cone-beam computed tomography views with the paired t-test, and the significance of differences among age groups with linear regression analysis. The significance level was set at p < 0.05. Results: The mesiobuccal and distobuccal root apexes of maxillary second molars were more distant from the buccal cortical plate than the maxillary first molars (p < 0.05). The apical 3-mm level of the mesiobuccal root of the first molar was closer to the buccal cortical bone than the second molar (p < 0.05). In the maxillary first molars, the thickness of the buccal cortical bone decreased in all roots with age (p < 0.05). In all root apexes of both molars, the difference in the vertical level between the maxillary sinus floor and the root apex increased with age (p < 0.05). Conclusions: Awareness of the anatomical profile of maxillary molar apices in relation to the cortical bones and maxillary sinus will be beneficial for apical surgery.

Biomechanical comparison of bone staple techniques for stabilizing tibial tuberosity fractures

  • Kyu-Tae Park;Min-Yeong Lee;Hwi-Yool Kim
    • Korean Journal of Veterinary Research
    • /
    • v.63 no.3
    • /
    • pp.24.1-24.6
    • /
    • 2023
  • This study compared the biomechanical properties of bone-stapling techniques with those of other fixation methods used for stabilizing tibial tuberosity fractures using 3-dimensionally (3D)-printed canine bone models. Twenty-eight 3D-printed bone models made from computed tomography scan files were used. Tibial tuberosity fractures were simulated using osteotomy. All samples were divided into 4 groups. Group 1 was stabilized with a pin and tension-band wire; group 2, with a pin and an 8 mm-wide bone staple; group 3, with 2 horizontally aligned pins and an 8 mm-wide bone staple; and group 4 with a 10 mm-wide bone staple. Tensile force was applied with vertical distraction until failure occurred. The load and displacement were recorded during the tests. The groups were compared based on the load required to cause displacements of 1, 2, and 3 mm. The maximum failure loads and modes were recorded. The loads at all displacements in group 4 were greater than those in groups 1, 2, and 3. The loads at 1, 2, and 3 mm displacements were similar in groups 1 and 3. There was no significant difference between groups 1 and 3. Groups 1 and 4 provided greater maximum failure loads than groups 2 and 3. Failure occurred because of tearing of the nylon rope, tibial fracture, wire breakage, pin bending, and fracture around the bone staple insertion. In conclusion, these results demonstrate that the bone-stapling technique is an acceptable alternative to tension-band wire fixation for the stabilization of tibial tuberosity fractures in canine bone models.

Dynamic CT Myocardial Perfusion Imaging in Patients without Obstructive Coronary Artery Disease: Quantification of Myocardial Blood Flow according to Varied Heart Rate Increments after Stress

  • Lihua Yu;Xiaofeng Tao;Xu Dai;Ting Liu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.22 no.1
    • /
    • pp.97-105
    • /
    • 2021
  • Objective: The present study aimed to investigate the association between myocardial blood flow (MBF) quantified by dynamic CT myocardial perfusion imaging (CT-MPI) and the increments in heart rate (HR) after stress in patients without obstructive coronary artery disease. Materials and Methods: We retrospectively included 204 subjects who underwent both dynamic CT-MPI and coronary CT angiography (CCTA). Patients with more than minimal coronary stenosis (diameter ≥ 25%), history of myocardial infarction/revascularization, cardiomyopathy, and microvascular dysfunction were excluded. Global MBF at stress was measured using hybrid deconvolution and maximum slope model. Furthermore, the HR increments after stress were recorded. Results: The median radiation dose of dynamic CT-MPI plus CCTA was 5.5 (4.5-6.8) mSv. The median global MBF of all subjects was 156.4 (139.8-180.4) mL/100 mL/min. In subjects with HR increment between 10 to 19 beats per minute (bpm), the global MBF was significantly lower than that of subjects with increment between 20 to 29 bpm (153.3 mL/100 mL/min vs. 171.3 mL/100 mL/min, p = 0.027). This difference became insignificant when the HR increment further increased to ≥ 30 bpm. Conclusion: The global MBF value was associated with the extent of increase in HR after stress. Significantly higher global MBF was seen in subjects with HR increment of ≥ 20 bpm.

Periprosthetic Occult Femoral Fracture: An Unknown Side Effect of Press-Fit Fixation in Primary Cementless Total Hip Arthroplasty

  • Ho Hyun Yun;Woo Seung Lee;Young Bin Shin;Tae Hyuck Yoon
    • Hip & pelvis
    • /
    • v.35 no.2
    • /
    • pp.88-98
    • /
    • 2023
  • Purpose: The objectives of this study were to examine the prevalence and risk factors for development of periprosthetic occult femoral fractures during primary cementless total hip arthroplasty (THA) and to assess the clinical consequences of these fractures. Materials and Methods: A total of 199 hips were examined. Periprosthetic occult femoral fractures were defined as fractures not detected intraoperatively and on postoperative radiographs, but only observed on postoperative computed tomography (CT). Clinical, surgical, and radiographic analysis of variables was performed for identification of risk factors for periprosthetic occult femoral fractures. A comparison of stem subsidence, stem alignment, and thigh pain between the occult fracture group and the non-fracture group was also performed. Results: Periprosthetic occult femoral fractures were detected during the operation in 21 (10.6%) of 199 hips. Of eight hips with periprosthetic occult femoral fractures that were detected around the lesser trochanter, concurrent periprosthetic occult femoral fractures located at different levels were detected in six hips (75.0%). Only the female sex showed significant association with an increased risk of periprosthetic occult femoral fractures (odds ratio for males, 0.38; 95% confidence interval, 0.15-1.01; P=0.04). A significant difference in the incidence of thigh pain was observed between the occult fracture group and the non-fracture group (P<0.05). Conclusion: Occurrence of periprosthetic occult femoral fractures is relatively common during primary THA using tapered wedge stems. We recommend CT referral for female patients who report unexplained early postoperative thigh pain or developed periprosthetic intraoperative femoral fractures around the lesser trochanter during primary THA using tapered wedge stems.

Anatomical study of the bone morphology of the anterior talofibular ligament attachment

  • Hitomi Fujishiro;Akimoto Nimura;Mizuki Azumaya;Soichi Hattori;Osamu Hoshi;Keiichi Akita
    • Anatomy and Cell Biology
    • /
    • v.56 no.3
    • /
    • pp.334-341
    • /
    • 2023
  • Anterior talofibular ligament (ATFL) injuries are the most common cause of ankle sprains. To ensure anatomically accurate surgery and ultrasound imaging of the ATFL, anatomical knowledge of the bony landmarks around the ATFL attachment to the distal fibula is required. The purpose of the present study was to anatomically investigate the ATFL attachment to the fibula with respect to bone morphology and attachment structures. First, we analyzed 36 feet using micro-computed tomography. After excluding 9 feet for deformities, the remaining 27 feet were used for chemically debrided bone analysis and macroscopic and histological observations. Ten feet of living specimens were observed using ultrasonography. We found that a bony ridge was present at the boundary between the attachments of the ATFL and calcaneofibular ligament (CFL) to the fibula. These two attachments could be distinguished based on a difference in fiber orientation. Histologically, the ATFL was attached to the anterodistal part of the fibula via fibrocartilage anterior to the bony ridge indicating the border with the CFL attachment. Using ultrasonography in living specimens, the bony ridge and hyperechoic fibrillar pattern of the ATFL could be visualized. We established that the bony ridge corresponded to the posterior margin of the ATFL attachment itself. The ridge was obvious, and the superior fibers of the ATFL have directly attached anteriorly to it. This bony ridge could become a valuable and easy-to-use landmark for ultrasound imaging of the ATFL attachment if combined with the identification of the fibrillar pattern of the ATFL.

Minimally invasive percutaneous endoscopic thoracolumbar foraminotomy in large-breed dogs-a comparative study

  • Soo Hee Lee;Soo Young Choi;Ho Hyun Kwak;Heung Myong Woo
    • Korean Journal of Veterinary Service
    • /
    • v.47 no.2
    • /
    • pp.61-72
    • /
    • 2024
  • This study aimed to evaluate the feasibility of percutaneous endoscopic foraminotomy (PEF) for the treatment of intervertebral disc herniation of the thoracolumbar spine in large-breed dogs by comparing it with open hemilaminectomy (OH). Six large-breed canine cadavers were used in the present study. A barium and agarose mixture (BA-gel) simulating intervertebral disc herniation was injected into the spinal canal at two intervertebral spaces (T12-T13, L2-L3) of the thoracolumbar spine in each cadaver. PEF and OH were randomly allocated to the sites in each cadaver. Computed tomography was performed pre- and postoperatively. The incision length, vertebral window size, procedure time, and amount of simulated disc material removed were recorded to compare PEF and OH. Both procedures clearly exposed the simulated disc material and spinal cord. The size of the incision and vertebral window created after PEF was much smaller than those after OH. The surgical duration of PEF was longer than that of OH. However, no significant difference (P>0.05) was observed in the amount of BA-gel removed between PEF and OH. Thus, PEF could be used as an effective surgical option for intervertebral disc herniation of the thoracolumbar region in large-breed dogs in that it could lead to less tissue damage as well as sufficient removal of the simulated disc material.