• Title/Summary/Keyword: Difference sets

검색결과 584건 처리시간 0.024초

일본어 모음 무성화의 통시적 변화 (Diachronic Change of High Vowel Devoicing in Japanese Dialects)

  • 변희경
    • 말소리와 음성과학
    • /
    • 제5권4호
    • /
    • pp.171-184
    • /
    • 2013
  • This study investigated the devoicing rate of Japanese high vowels, focusing on regional and generational differences by acoustically analyzing vowels from two large speech databases. The first speech database used in this study was collected between 1986 and 1988 from 41 areas (prefectures) which included 607 participants (299 high school students and 308 their grandparents). The second was taken from a 2006-2007 collection from seven areas as a follow-up investigation to the first database consisting of 463 participants ranging in age from 8-90 year olds. The results revealed there is a generational as well as regional difference in the devoicing rate in almost all areas. Based on those results, a new distribution map reflecting a current devoicing rate of the younger generation was presented. Furthermore, by comparing the two data sets, this study confirmed age difference in the devoicing rate is not age-grading but a sound change in progress. This study discusses the social factors for changes in the devoicing rate of some areas and then applies the devoicing rate of five areas to an S-curve model to predict the future devoicing rate.

Effect of Acute Aquatic Plyometric Training on Muscle Strength, Edema and Pain

  • Kim, Byung Kwan;Jeong, Hwan Jong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권1호
    • /
    • pp.224-232
    • /
    • 2022
  • The purpose of this study was to investigate the pre- and post-exercise performance, edema, and pain of plyometrics in water and land environments. Twelve males in their 20s were selected as subjects and performed 10 sets of squat jumps 10 times in 2 environmental conditions (water and ground). There was no significant difference in iEMG of vastus medilais according to exercise conditions and time. In MPV of CMJ, there was no significant difference according to exercise conditions and time. The thigh circumference showed a significant difference according to the exercise condition and time, and was higher in the ground condition after exercise. There was a significant difference in pain according to the exercise condition and time, and it was found to be high after exercise, 48 hours, and 72 hours in the ground condition. We believe that plyometric training in an aquatic environment will have less swelling and pain compared to plyometric training conducted in a land environment, and the pain will improve quickly, so we think that training can be conducted in a relatively shorter period than in the land environment.

분석조건별 담수어류의 환경 DNA 메타바코딩 효율 비교: 필터, 추출 키트, 프라이머 조합 및 PCR 방법 (Efficiency Comparison of Environmental DNA Metabarcoding of Freshwater Fishes according to Filters, Extraction Kits, Primer Sets and PCR Methods)

  • 김근식;김근용;윤주덕
    • 생태와환경
    • /
    • 제54권3호
    • /
    • pp.199-208
    • /
    • 2021
  • 메타바코딩을 이용한 환경 DNA 분석은 검출 감도가 높아 어류의 생물다양성 평가 및 멸종위기종의 검출에 유용한 기술이다. 이번 연구는 메타바코딩을 이용해 우리나라 담수어류를 대상으로 높은 검출 효율을 보일 수 있는 적합한 분석방법을 확인하기 위해 4가지 분석조건별, 즉 필터(cellulose nitrate filter, glass fiber filter), 추출 키트(DNeasy® Blood & Tissue Kit, DNeasy® PowerWater Kit), 프라이머 조합(12S rDNA, 16S rDNA) 그리고 PCR 방법(conventional PCR, touchdown PCR)로 나타나는 Operational Taxonomic Units(OTUs) 수와 종 조성을 비교하였다. Glass fiber filter와 DNeasy® Tissue & Blood Kit를 이용해 추출한 시료는 12S rDNA와 16S rDNA 프라이머 조합에서 담수어류 OTUs가 가장 많이 검출되었다. 모든 분석조건 중 프라이머 조합에서만 조기어강(Class Actinopterygii) 평균 OTUs 수에서 통계적으로 유의한 차이를 보였고(Non-parametric Wilcoxon Signed Ranks Test, p=0.005), 담수어류 평균 OTUs 수는 유의하지 않았다. 종 조성 비교 결과 역시 프라이머 조합에서 유의한 차이를 보였고(PERMANOVA, Pseudo-F=6.9489, p=0.006), 나머지 분석조건에서는 유의한 차이를 보이지 않았다. NMDS 분석 결과 종 조성은 유사도 65% 기준에서 프라이머 조합에 따라 묶였고, 16S rDNA 프라이머 세트는 주로 멸종위기종인 모래주사(Microphysogobio koreensis), 꼬치동자개(Pseudogobio brevicorpus)가 기여하였고, 12S rDNA 프라이머 세트는 주로 일반종인 피라미(Zacco platypus), 꺽지(Coreoperca herzi) 등이 기여한 것으로 나타났다. 본 연구는 국내 하천에서 채취한 시료에 대한 메타바코딩을 이용한 종 다양성 분석의 기초정보를 제공한다.

전처리과정을 갖는 시계열데이터의 퍼지예측 (A Fuzzy Time-Series Prediction with Preprocessing)

  • 윤상훈;이철희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 D
    • /
    • pp.666-668
    • /
    • 2000
  • In this paper, a fuzzy prediction method is proposed for time series data having uncertainty and non-stationary characteristics. Conventional methods, which use past data directly in prediction procedure, cannot properly handle non-stationary data whose long-term mean is floating. To cope with this problem, a data preprocessing technique utilizing the differences of original time series data is suggested. The difference sets are established from data. And the optimal difference set is selected for input of fuzzy predictor. The proposed method based the Takigi-Sugeno-Kang(TSK or TS) fuzzy rule. Computer simulations show improved results for various time series.

  • PDF

수질 특성(TSS) 파악을 통한 1차 침전지 성능 평가 (TSS 농도를 중심으로) (Evaluation of Primary Clarifier by Wastewater TSS Characterization)

  • 이병희
    • 상하수도학회지
    • /
    • 제23권3호
    • /
    • pp.363-369
    • /
    • 2009
  • In order to evaluate primary clarifier performance on TSS(Total Suspended solids) removal, four different sampling sets were collected as part of this study; (1) weekly test, (2) the diurnal sampling, (3) the settling velocity distribution sampling. Primary effluent TSS($TSS_{PE}$) and non settleable TSS($TSS_{NON}$) concentrations were averaged 160 and 75.5 mg/L, respectively. These data suggest approximately 85 mg/L TSS can be removed more. Average $TSS_{NON}$, $TSS_{PE}$, and Dispersed TSS(DTSS) concentrations(75.5, 160, and 104 mg/L, respectively) suggest that 28.5 mg/L of TSS difference attributable to poor flocculation, whereas 56 mg/L of TSS difference attributable to poor hydraulics within primary clarifier. In this study, equations for maximum TSS removal efficiency and effluent TSS concentration were suggested and compared with experimented data.

Entropy-based Similarity Measures for Memory-based Collaborative Filtering

  • Kwon, Hyeong-Joon;Latchman, Haniph
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제5권2호
    • /
    • pp.5-10
    • /
    • 2013
  • We proposed a novel similarity measure using weighted difference entropy (WDE) to improve the performance of the CF system. The proposed similarity metric evaluates the entropy with a preference score difference between the common rated items of two users, and normalizes it based on the Gaussian, tanh and sigmoid function. We showed significant improvement of experimental results and environments. These experiments involved changing the number of nearest neighborhoods, and we presented experimental results for two data sets with different characteristics, and results for the quality of recommendation.

CRT-02: Television Sets with Ultra-Slim Transposed Scan CRTs

  • Wesenbeeck, R.J. Van;Bosma, M.;Heynderickx, I.;Krijn, M.P.C.M.;Mastenbroek, E.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.347-350
    • /
    • 2002
  • Transposed scan is an innovation that paves the road to ultra-slim CRTs with deflection angles up to 135$^{\circ}C$ We discuss the integration of video transposition with the other video processing functions in the television set. An in-place transposition algorithm which minimizes the amount of frame memory is proposed as a low-cost solution for transposed scan conversion. The difference in visual perception of transposed scan and normal scan depends on the frame rate and the line density of the video format. We found that for high frame rates and high line densities, no difference was perceived for both scan modes.

  • PDF

Ultrasonographic evaluation of rotator cuff leison

  • Sugimoto Katsumasa;Matsui Nobuo
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 1995년도 Symposium and Workshop
    • /
    • pp.46-46
    • /
    • 1995
  • We investigated the reliablity of the ultrasonography for diagnosis of rotatar cuff taers. We prepared histological sections of forty shoulder joints In match the ultrasound planes, and conducted a comparative study of tke two sets of images. hi cases of rotator cuff tear, hyperechogenic and cartilaginfication of the tear site were detected as hyperechogenic foci. On the countrary, the regions in which tendon fibers were decreased or absent showed sonolucent areas. We caluculated the echo level of rotator cuff objectively. The area of abnormal echo level and the other regions located in the same depth of the rotator cuff were defined by ultrasonic equipment. The mein difference in these two echo levels was calculated. The mean difference in patients with rotator cuff tears was larger than that in normal cases. These results indicate that ultrasonography is a useful procedure in many patients with rotator cuff lesions.

  • PDF

Pure additive contribution of genetic variants to a risk prediction model using propensity score matching: application to type 2 diabetes

  • Park, Chanwoo;Jiang, Nan;Park, Taesung
    • Genomics & Informatics
    • /
    • 제17권4호
    • /
    • pp.47.1-47.12
    • /
    • 2019
  • The achievements of genome-wide association studies have suggested ways to predict diseases, such as type 2 diabetes (T2D), using single-nucleotide polymorphisms (SNPs). Most T2D risk prediction models have used SNPs in combination with demographic variables. However, it is difficult to evaluate the pure additive contribution of genetic variants to classically used demographic models. Since prediction models include some heritable traits, such as body mass index, the contribution of SNPs using unmatched case-control samples may be underestimated. In this article, we propose a method that uses propensity score matching to avoid underestimation by matching case and control samples, thereby determining the pure additive contribution of SNPs. To illustrate the proposed propensity score matching method, we used SNP data from the Korea Association Resources project and reported SNPs from the genome-wide association study catalog. We selected various SNP sets via stepwise logistic regression (SLR), least absolute shrinkage and selection operator (LASSO), and the elastic-net (EN) algorithm. Using these SNP sets, we made predictions using SLR, LASSO, and EN as logistic regression modeling techniques. The accuracy of the predictions was compared in terms of area under the receiver operating characteristic curve (AUC). The contribution of SNPs to T2D was evaluated by the difference in the AUC between models using only demographic variables and models that included the SNPs. The largest difference among our models showed that the AUC of the model using genetic variants with demographic variables could be 0.107 higher than that of the corresponding model using only demographic variables.

Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.