• Title/Summary/Keyword: Difference Pressure

Search Result 3,926, Processing Time 0.039 seconds

Power Generation Performance Evaluation according to the Vehicle Running on the Hybrid Energy Harvesting Block (하이브리드 에너지하베스팅 블록의 차량주행 발전성능 평가)

  • Kim, Hyo-Jin;Park, Ji-Young;Jin, Kyu-Nam;Noh, Myung-Hyun
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.307-314
    • /
    • 2016
  • Energy harvesting technique is to utilize energy that is always present but wasted. In this study, we have developed the energy harvester of the hybrid method utilizing both vibration and pressure of the vehicle traveling a road or parking lot. In the previous study, we have developed a prototype energy harvester, improved hybrid energy harvester, and developed a final product that offers improved performance in the hybrid module. The results were published in the previous paper. In this study, we installed the finally developed hybrid module in the actual parking lot. And we measured the power generation performance due to pressure and vibration, and the running speed of the vehicle when the vehicle is traveling. And we compared the results with those obtained in laboratory conditions. In a previous study performed in laboratory conditions the maximum power of the energy block was 1.066W when one single time of vibration, and 1.830W when succession with 5 times. On the other hand, in this study, we obtained the average power output of 0.310W when the vehicle is running at an average 5 km/h, 0.670W when at an average 10 km/h, and 1.250W when at an average 20 km/h, and 2.160W when at an average 5 km/h. That is, the higher the running speed of the vehicle has increased power generation performance. However, when compared to laboratory conditions, the power generation performance of the energy block in driving speed by 20km/h was lower than those in laboratory conditions. In addition, when compared to one time of vibration of laboratory conditions, power generation performance was higher when the running speed 20km/h or more and when five consecutive times in laboratory conditions, it was higher when the running speed 30km/h or more. It could be caused by a difference of load conditions between the laboratory and the actual vehicle. Thus, applying the energy block on the road would be more effective than that on the parking lot.

A Numerical Study on the CO2 Leakage Through the Fault During Offshore Carbon Sequestration (해양지중에 저장된 이산화탄소의 단층을 통한 누출 위험 평가에 관한 수치해석 연구)

  • Kang, Kwangu;Huh, Cheol;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.2
    • /
    • pp.94-101
    • /
    • 2015
  • To mitigate the greenhouse gas emission, many carbon capture and storage projects are underway all over the world. In Korea, many studies focus on the storage of $CO_2$ in the offshore sediment. Assurance of safety is one of the most important issues in the geological storage of $CO_2$. Especially, the assessment of possibility of leakage and amount of leaked $CO_2$ is very crucial to analyze the safety of marine geological storage of $CO_2$. In this study, the leakage of injected $CO_2$ through fault was numerically studied. TOUGH2-MP ECO2N was used to simulate the subsurface behavior of injected $CO_2$. The storage site was 150 m thick saline aquifer located 825 m under the continental shelf. It was assumed that $CO_2$ leak was happened through the fault located 1,000 m away from the injection well. The injected $CO_2$ could migrate through the aquifer by both pressure difference driven by injection and buoyancy force. The enough pressure differences made it possible the $CO_2$ to migrate to the bottom of the fault. The $CO_2$ could be leaked to seabed through the fault due to the buoyancy force. Prior to leakage of the injected $CO_2$, the formation water leaked to seabed. When $CO_2$ reached the seabed, leakage of formation water stopped but the same amount of sea water starts to flow into the underground as the amount of leaked $CO_2$. To analyze the effect of injection rate on the leakage behavior, the injection rate of $CO_2$ was varied as 0.5, 0.75, and $1MtCO_2/year$. The starting times of leakage at 1, 0.75 and $0.5MtCO_2/year$ injection rates are 11.3, 15.6 and 23.2 years after the injection, respectively. The leakage of $CO_2$ to the seabed continued for a period time after the end of $CO_2$ injection. The ratios of total leaked $CO_2$ to total injected $CO_2$ at 1, 0.75 and $0.5MtCO_2/year$ injection rates are 19.5%, 11.5% and 2.8%, respectively.

Effect of Pesticide Residues on Perilla Leaf by Nozzle Types of Knapsack Sprayers (배부식 분무기 노즐이 들깻잎의 농약잔류에 미치는 영향)

  • Son, Kyeong-Ae;Kang, Tae Kyeong;Park, Byeong Jun;Jin, Yong-Duk;Gil, Geun-Hwan;Kim, Chan Sub;Kim, Jin Bae;Im, Geon-Jae;Lee, Key-Woon
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.282-287
    • /
    • 2012
  • This study was carried out to clarify the effects of the application of pesticide by different spray nozzle types on pesticide residues. The average droplet size and discharge rate were investigated when the manual compressed sprayer with two head disk type nozzle and the knapsack engine powered sprayer with two head fan shape nozzles were used. The fan type nozzles were classified into three types by the number of orifice in the nozzle. Three type nozzles tested were fan with one orifice, fan with two orifices and fan with three orifices. Fan (trade name : D-3) with 2.4 L/min. of the discharge rate and $76{\mu}m$ of the average droplet size while maintaining constant pressure $1.1{\pm}0.2$ MPa, and fan D-35 with 2.6 L/min. and $90{\mu}m$ while maintaining constant pressure $1.0{\pm}0.2$ MPa were appropriate. The orifice size of D-3 was 0.65 mm length ${\times}$ 0.45 mm width and the orifice size of D-35 was 0.62 mm length ${\times}$ 0.46 mm width. The residue levels of imidacloprid on perilla leaves among four applications by four different nozzles show significantly difference with 5% significance level. The residue levels $3.76{\sim}3.92mg\;kg^{-1}$ by fan or disk type is smaller than $4.52{\sim}4.92mg\;kg^{-1}$ by fan II or fan III. The residue levels of imidacloprid on perilla leaf were different depend on the spray nozzles type.

Superiority of Modifiled University of Wiscinsin Solution in the Prolonged Preservation of Isolated Rat Heart (적출 쥐 심장의 장시간 보존에 있어서 University of Wisconsin 수정 용액의 우수성)

  • Lee, Jae-Seong;Kim, Song-Myeong;Kim, Gyu-Tae
    • Journal of Chest Surgery
    • /
    • v.26 no.6
    • /
    • pp.427-440
    • /
    • 1993
  • The paucity of donor hearts for transplantation can be remedied by distant heart procurement. Prolonging donor heart preservation is essential for successful clinical cardiac transplantation. Thirty-two isolated rat hearts were perfused with Krebs-Henseleit buffer solution for 15 minutes, arrested and preserved at 4 oC for 4 hours, and then reperfused for 25 minutes. The following three groups were prepared and hemodynamic changes, creatine kinase-MB isoenzyme levels and ultrastructural changes of the myocardium were analysed before and after cardiac arrest. ; Group I : the heart was arrested with the cardioplegic solution [Plegisol, potassium : 16 mM, sodium : 120 mM] and then stored in a solution with ionic compositions of the extracellular fluid [Hartman, potassium : 4 mM, sodium : 130 mM] ; Group II : the heart was arrested with the cardioplegic solution and stored in a solution with ionic compositions of the intracellular fluid [Modified Euro-Collins, potassium : 108 mM, sodium : 10 mM] ; Group III : the heart was arrested with the cardioplegic solution containing adenosine 20 uM, and then stored in a solution with ionic compositions of the intracellular fluid [Modified University of Wisconsin solution, potassium : 119 mM, sodium: 23 mM]. Left ventricular developed pressure at 20 minutes of the reperfusion was significantly higher in group III [64.3 $\pm$ 3.12 mmHg, p<0.01] and group II [58.3 $\pm$ 1.55 mmHg, p<0.05] as compared with group I [51.4$\pm$ 2.78 mmHg]. The time to induce cardiac arrest after infusion of cardioplegic solution with adenosine 20 uM [5.3 $\pm$ 0.30 second, p<0.005] was significantly shorter than without adenosine [10.6$\pm$ 0.55 second]. Coronary flow at 20 minutes of the reperfusion was augmented significantly in group III [9.6$\pm$ 0.50 ml/min, p<0.05, p<0.05] as compared with group I [8.0 $\pm$ 0.41 ml/min] and group II [8.1$\pm$ 0.51 ml/min]. Percentage recovery of left ventricular developed pressure at 20 minutes of the reperfusion was significantly higher in group III [94.6$\pm$ 2.51 %, p<0.005] as compared with group II and in group II [83.1 $\pm$ 1.22 %, p<0.005] as compared with group I [69.9 $\pm$ 1.73 %], and also percentage recovery of coronary flow at 20 minutes of the reperfusion was significantly higher in group III [82.3 $\pm$ 3.86 %, p<0.05] as compared with group II [71.4 $\pm$ 3.46 %] but there was no significant difference between group I and group II. Measured level of creatine kinase-MB isoenzyme at 15 minutes of the reperfusion was significantly lower in group III [1.23 $\pm$ 0.16 ng/ml, p<0.025] and group II [1.42$\pm$ 0.10 ng/ml, p<0.05] as compared with group I [1.79 0.14 ng/ml]. In the semiquantitative evaluation of the ultrastructural changes of the myocardium, mitochondrial score was lower in group III [0.7 $\pm$ 0.21] than in group I [3.1$\pm$ 0.28] and group II [1.7 $\pm$ 0.19], and also the other structural score was lower in group III [2.7$\pm$ 0.99] than in group I [7.9 $\pm$ 0.89] and group II [5.0 $\pm$ 1.22]. In conclusion, the solution with ionic compositions of the intracellular fluid is appropriate for prolonged cardiac preservation, and it appears to be better preserving method for distant procurement when the donor heart is rapidly arrested with cardioplegic solution containing adenosine 20 uM, and then stored with Modified University of Wisconsin solution.

  • PDF

Studies on the Contents of the Nutrients and the Nucleotides in Soup Stock During Cooking of Cow's Rumen-Reticulum (소양(Cow's Rumen-reticulum)영양성의 가열조리시 분과 맛성분의 용출에 관한 연구)

  • Lee, Yeon-Sook;Park, Dong-Yeon;Park, Jung-Sook
    • Journal of the Korean Society of Food Culture
    • /
    • v.4 no.3
    • /
    • pp.245-251
    • /
    • 1989
  • To estimate the nutritional values and the optimum cooking method of the Cow's rumen-reticulum (tripe) which is a Korean traditional food, the nutrients of raw tissue of tripes, the changes in total N, ${\alpha}-amino$ N, calcium and phosphorus contents and nucleotides and their related compounds contents in soup stock prepared of tripe tissues according to various boiling time period with saucepot or pressure cooker and various ratios of the water to the tripe (wt/wt) were measured. No significant difference was observed in nutrients contents between rumen (1st stomach) and reticulum (2nd stomach) which contained 83% moisture, 0.4-0.5% ash, 3% fat, 13% protein, 50-56 mg% calcium, 75-76 mg% phosphorus. 75-77 mg% ${\alpha}-amino$ N on fresh weight basis. The results obtained show that the significant loss of nutrients observed after removing epitherial cell layer from tripe, and in aspect of the nutrients contents, the nucletides contents, and the sensory evaluation score in soup stock, the optimum cooking time period of tripe was 8 hours in boiling in saucepot and 1 or 2 hours in cooking in pressure cooker, and the ratio of the water to the tripe (wt/wt) was above ten.

  • PDF

The Study on the Seasonal Variation of Microbial Community in Kyeonggi Bay, Korea 1. Bacteria and Heterotrophic nanoflagellates (경기만 수역에서 미세생물 군집의 계절적 변동 연구 I. 박테리아와 종속영양 미소 편모류)

  • 양은진;최중기;현정호
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.8 no.1
    • /
    • pp.44-57
    • /
    • 2003
  • Seasonal variations of bacterial abundance and production, heterotrophic nanoflagellate (HNF) abundance and HNF ingestion rates on bacteria using FLB together with environmental variables were investigated at intervals of a month in Kyeonggi Bay from December 1991 to November 1998. Bacterial abundance and production ranged from 0.38$\times$10$^{9}$ ~ 3.25$\times$10$^{9}$ cells 1$^{-1}$ (average 1.19$\pm$0.69$\times$10$^{9}$ cells 1$^{-1}$ ) and from 1.51 to 20.4 cells 1$^{-1}$ h$^{-1}$ (average 6.04$\pm$ 1.88$\times$10$^{6}$ cells 1$^{-1}$ h$^{-1}$ ), respectively. Bacterial abundance and production showed no differences at the high tide and low tide, and bacterial abundances were not different with depth, but bacterial production decreased with depth. Seasonal variation of bacterial abundance showed almost similar fluctuation pattern to those of DOC (dissolved organic carbon). HNF abundances ranged from 388 to 4,374 cells ml$^{-1}$ (average 1,344$\pm$130 cells ml$^{-1}$ ), were high in March, April, July and August. HNF abundance showed no difference between the high tide and low tide, and was not different with depth. The ingestion rates of HNF on bacteria were 1.0 to 6.3$\pm$10$^{6}$ bacteria 1$^{-1}$ h$^{-1}$ (average 3.12$\pm$0.55$\times$10$^{6}$ bacteria 1$^{-1}$ h$^{-1}$ ), resulting ingestion rates of HNF removed 19.4 to 141.4 %(average 62.3$\pm$12.0%) of bacterial production. Ingestion rates and grazing pressure of HNF on bacteria showed high correlation with HNF abundance. Although we cannot exactly discussion about seasonal variation of bacteria community in this study area where physical and chemical parameters were very complex, the results indicate that bacterial abundance and production were mainly controlled by resources supply as dissolved organic carbon and chlorophyll-a(bottom-up) except March which bacterial abundance and production uncoupled chlorophyll-a because of low dissolved organic carbon and low temperature, and were controlled by HNF grazing pressure(top-down) in the warm seasons except the winter.

Assessment of Parameters Measured with Volumetric Pulmonary Artery Catheter as Predictors of Fluid Responsiveness in Patients with Coronary Artery Occlusive Disease (관상동맥 질환을 가진 환자에서 폐동맥카테터로 측정한 전부하 지표들은 수액부하 반응을 예상할 수 있는가?)

  • Lee, Ji-Yeon;Lee, Jong-Hwa;Shim, Jae-Kwang;Yoo, Kyung-Jong;Hong, Seung-Bum;Kwak, Young-Lan
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.41-48
    • /
    • 2008
  • Background: Accurate assessment of the preload and the fluid responsiveness is of great importance for optimizing cardiac output, especially in those patients with coronary artery occlusive disease (CAOD). In this study, we evaluated the relationship between the parameters of preload with the changes in the stroke volume index (SVI) after fluid loading in patients who were undergoing coronary artery bypass grafting (CABG). The purpose of this study was to find the predictors of fluid responsiveness in order to assess the feasibility of using. certain parameters of preload as a guide to fluid therapy. Material and Method: We studied 96 patients who were undergoing CABG. After induction of anesthesia, the hemodynamic parameters were measured before (T1) and 10 min after volume replacement (T2) by an infusion of 6% hydroxyethyl starch 130/0.4 (10 mL/kg) over 20 min. Result: The right ventricular end-diastolic volume index (RVEDVI), as well as the central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP), failed to demonstrate significant correlation with the changes in the SVI (%). Only the right ventricular ejection fraction (RVEF) measured at T1 showed significant correlation. with the changes of the SVI by linear regression (r=0.272, p=0.017). However, when the area under the curve of receiver operating characteristics (ROC) was evaluated, none of the parameters were over 0.7. The volume-induced increase in the SVI was 10% or greater in 31 patients (responders) and under 10% in 65 patients (non-responders). None of the parameters of preload measured at T1 showed a significant difference between the responders and non-responders, except for the RVEF. Conclusion: The conventional parameters measured with a volumetric pulmonary artery catheter failed to predict the response of SVI following fluid administration in patients suffering with CAOD.

Quality and Antioxidant Characteristics of Cooked Rice Influenced by the Mixing Rate of Glutinous Rice and Cooking Methods (찹쌀 첨가와 취반방법에 따른 취반 밥의 품질 및 항산화특성)

  • Kim, Mi-Jung;Lee, Kyung Ha;Kim, Hyun-Joo;Ko, Jee Yeon;Lee, Seuk Ki;Park, Hye Young;Sim, Eun-Yeong;Oh, Sea Kwan;Lee, Choon Ki;Woo, Koan Sik
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.62 no.2
    • /
    • pp.96-104
    • /
    • 2017
  • This study was carried out to compare the cooking and antioxidant characteristics of rice containing varying amounts of glutinous rice and cooked by two methods. Rice containing glutinous rice was cooked by general and high-pressure cooking methods with and without fermented alcohol. Pasting characteristics of cooked rice were decreased with increasing amounts of glutinous rice. The water binding capacity and swelling power were significantly decreased with increasing amounts of glutinous rice; however, water solubility indices were significantly increased. Palatability characteristics of cooked rice containing glutinous rice were similar to those of cooked rice without glutinous rice. Total polyphenol contents of cooked rice containing glutinous rice and fermented alcohol were quite different, but this difference was not significant. Total flavonoid contents were increased with increasing amounts of glutinous rice. Total flavonoid content by general cooking method for rice containing 20% glutinous rice and fermented alcohol was $23.20{\pm}0.61{\mu}g\;CE/g$. DPPH radical-scavenging activities for samples with and without glutinous rice were 2.97-5.19 and 3.19-5.45 mg TE/100 g, respectively. ABTS radical-scavenging activity by high-pressure cooking method for rice containing 20% glutinous rice and fermented alcohol was $19.48{\pm}0.63mg\;TE/100g$. In this study, cooking and antioxidant characteristics of cooked rice containing glutinous rice generated data useful for manufacturing processed products.

Effect of Coolant on PEMFC Performance in Low Humidification Condition (저가습 조건에서 냉각 유체의 고분자전해질 연료전지에 대한 영향)

  • Lee, Hung-Joo;Song, Hyun-Do;Kwon, Jun-Taek;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.25-30
    • /
    • 2007
  • Proton exchange membrane fuel cell(PEMFC) performance could be affected by various factors such as cell temperature, total pressure, partial pressure of reactants and relative humidity. Hydrogen ion is combined with water to form hydronium ion [$H_3O^+$] and pass through membrane resulting electricity generation. Cooling system is needed to remove heat and other uses on large scale fuel cell. In case that collant conductivity is increased, fuel cell performance could be decreased because produced electricity could be leaked through coolant. In this study, triple distilled water(TDW) and antifreeze solution containing ethylene glycol was used to observe resistance change. Resistance of TDW was taken 28 days to reach preset value, and effect on fuel cell operation was not observed. Resistance of antifreeze solution was not reached to preset value up to 48 days, but performance failure occurred presumably caused by bipolar plate junction resulting stoppage resistance experiment. Generally PEMFC humidification is performed near-saturated operating conditions at various temperatures and pressures, but non-humidifying condition could be applied in small scale fuel cell to improve efficiency and reduce system cost. However, it was difficult to operate large scale fuel cell without humidifying, especially higher than $50{\sim}60^{\circ}C$. In case of small flux such as 0.78 L/min, temperature difference between inlet and outlet was occurred larger than other cases resulting performance decrease. Non-humidifying performance experiments were done at various cell temperature. When both of anode and cathode humidification were removed, cell performance was strongly depended on cell operating temperature.

The Difference of the Cleaning and Wettability-maintaining Efficacy of Lens Care Solution to RGP Lens (관리 용품에 따른 RGP 렌즈의 세척효과 및 습윤성 차이)

  • Kim, Myoung-Hea;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.27-34
    • /
    • 2006
  • We investigated the question whether the efficacy of cleaning tear components on RGP lens and preserving the superior wettability of RGP lens depended on the different type of contact lens care system - RGP lens care solution, SCL care solution, combined solution both for SCL and RGP lens or saline solution. The removal efficacy of the deposited protein was examined by Lowry protein assay and Scanning Electro Microscope(SEM) and residual lipid concentration on RGP lens was determined by High Pressure Liquid Chromatology(HPLC). Wettability was assessed with an equilibrium water-in-air contact angle method. When cared by RGP lens solution, it was demonstrated that 62 percent out of the adhered protein on RGP lens were removed and the removal efficacy of RGP lens solution was not only 4 times than saline solution and the alternative but also higher twice than SCL solution. Contrarily, the SCL solution had the most excellent removal efficacy of the adhered protein on SCL. These results suggest that the cleaning efficacy is thought to be affected by the other factors like the viscosity of care solutions, which mutual contact between RGP lens and care solutions is on the increase due to the viscosity enhancer in RGP lens care solution. RGP lens solution had the greatest removing efficacy to cholesterol and the residual cholesterol concentration was decreased to 50%. It is significant for RGP lens to preserve the superior wettability which means the predictive value for comfortable wearing and it showed that the RGP lens solution offered the most excellent efficacy to maintain the surface wettability. Combined solution both for SCL and RGP lens had weak efficacy of cleaning and maintaining wettability for RGP lens compared to RGP lens care solution.

  • PDF