• Title/Summary/Keyword: Diesel Bus

Search Result 59, Processing Time 0.027 seconds

Identifying Ambient PM2.5 Sources and Estimating their Contributions by Using PMF : Separation of Gasoline and Diesel Automobile Sources by Analyzing ECs and OCs (PMF 모델을 이용한 미세분진의 오염원 확인과 기여도 추정 : 탄소성분을 이용한 휘발유 및 경유차량 오염원의 분리)

  • Lee, Hyung-Woo;Lee, Tae-Jung;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.1
    • /
    • pp.75-89
    • /
    • 2009
  • The purpose of this study was to identify $PM_{2.5}$ sources and to estimate their contributions to the border of Yongin-Suwon area, based on the analysis of the $PM_{2.5}$ mass concentration and the associated inorganic elements, ions and carbon components. The contribution of $PM_{2.5}$ sources were estimated by using a positive matrix factorization (PMF) model to identify air emission sources. For this study, $PM_{2.5}$ samples were collected from May, 2007 to April, 2008. The inorganic elements were analyzed by an ICP-AES. The ionic components in $PM_{2.5}$ were analyzed by an Ie. The carbon components were also analyzed by DRI/OGC analyzer. After performing PMF modeling, a total of 12 sources were identified and their contributions were quantitatively estimated. The contributions from each emission source were as follows: 11.3% from oil combustion source, 3.4% from bus/highway source, 5.8% from diesel vehicle source, 4.7% from gasoline vehicle source, 8.8% from biomass burning source, 15.1 % from secondary sulfate, 5.2% from secondary nitrate source, 13.4% from industrial related source, 4.1% from Cl-rich source, 19.6% from soil related source, 1.0% from aged sea salt, and 7.4% from coal combustion source, respectively. This study provides basic information on the major sources affecting air quality, and then it will help to effectively control $PM_{2.5}$ in this study area.

Cognitive Perception of an Eco-friendly Public Transportation : Using Principal Component Analysis (친환경 대중교통 수단에 대한 인지적 특성 비교 분석 : 주성분분석을 활용하여)

  • Kwon, Yeongmin;Kim, Suji;Byun, Jihye
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.1
    • /
    • pp.71-82
    • /
    • 2020
  • The existing transportation system, which is based on internal combustion engines, is rapidly being converted to electrification. Thus, eco-friendly public transportation with high transportation efficiency will continue to spread throughout the market in the near future. The purpose of this study is to compare and analyze the cognitive characteristics of passengers redgarding the technical and social factors of various public transportation means to help a successful introduction of eco-friendly public transit. Through a survey questionnaire (N=485), seven factors of seven transportation modes were evaluated and analyzed using principal component analysis. As a result, it is confirmed that potential passengers have high expectations for the eco-friendliness and city image of the eco-friendly buses. Also, it is confirmed that eco-friendly buses are superior in cleanliness and ride comfort than diesel buses. Given the study's results, this study identifies the cognitive characteristics of passengers regarding eco-friendly public transportation. We hope that these results will be used as basic information for image positioning and improved service with the use of eco-friendly transportation.

Components sizing of powertrain for a Parallel Hybridization of the Mid-size Low-Floor Buses (중형저상버스 병렬형 하이브리드화를 위한 동력전달계 용량매칭)

  • Kim, Gisu;Park, Yeong-il;Ro, Yun-sik;Jung, Jae-wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.582-594
    • /
    • 2016
  • Most studies on hybrid buses are on large-sized buses and not mid-sized low-floor buses. This study uses MATLAB simulation to evaluate the fuel efficiency of such buses powered by diesel. Based on the results, a hybrid electric vehicle system is recommended for the best combination of power and gear ratio. A parallel hybrid system was selected for the hybridization, which transmits front and rear wheel power independently. The necessary power to satisfy the target performance was calculated, and the applicable capacity area was designed. Dynamic programing was used to create and optimize a component sizing algorithm, which was used to scale the capacity of each component of the power source to satisfy the design criteria. The fuel efficiency rate, optimum power source capacity, and gear ratio can be improved by converting a conventional bus into a parallel hybrid bus.

Concentration of $NO_2$ and $SO_{2}$ of Bus Terminals in Seoul (서울시 버스터미널의 이산화질소 및 아황산가스 농도)

  • 손부순;장봉기;김영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.51-59
    • /
    • 1997
  • In this study, we researched the concentration of nitrogen dioxide($NO_{2}$) and sulfur dioxide($SO_{2}$) of indoor(waiting room) and outdoor(place of getting on the bus) at the bus terminals (Kang-Nam, Dong-Seoul and Nam-Bu) in Seoul to recognize the degree of pollution by exhaust gas of the diesel engine vehicles, and examine the factor that might affect air pollution of terminals. The concentration of $NO_{2}$ and $SO_{2}$ were measured in winter and summer, and the results of the analysis are as follows : The mean concentration of $NO_{2}$ was $57.49{\pm}21.86$ ppb and the concentration of outdoor with $64.10{\pm}27.69$ ppb was significantly higher than the indoor with $50.89{\pm}10.92$ ppb (p<0.05), and the highest with $73.54{\pm}25.54$ ppb at Kang-Nam terminal (p<0.01). The mean concentration of $NO_{2}$ was $62.80{\pm}24.74$ ppb in winter and $52.19{\pm}17.50$ ppb in summer, and had a not statistical difference. The mean concentration of $SO_{2}$ was $31.71{\pm}8.73$ ppb and the concentration of outdoor with $31.04{\pm}8.89$ ppb was similar to the indoor $32.29{\pm}8.70$ ppb, and the highest with $32.57{\pm}9.01$ ppb at Dong-Seoul terminal (p<0.05). The mean concentration of $SO_{2}$ in winter with $39.67{\pm}4.10$ ppb was significantly higher than in summer with $23.76{\pm}2.61$ ppb (p<0.01). The concentration of outdoor $NO_{2}$ at Kang-Nam terminal was 104, 84 ppb in winter and 81.20 ppb in summer, and had a statistical difference compared with the concentration of indoor $NO_{2}$ at Dong-Seoul and Nam-Bu terminals. The concentration of indoor $NO_{2}$ and $SO_{2}$ were higher than that of outdoor at Kang-Nam and Dong-Seoul terminals, but on the contrary, lower than that of outdoor at Nam-Bu terminal. The concentration of $NO_{2}$ and $SO_{2}$ at Nam-Bu terminal were lower than those at Kang-Nam and Dong-Seoul terminals. While the concentration of $SO_{2}$ show the large difference between winter and summer, that of $NO_{2}$ dose not.

  • PDF

On-Road Investigation of PM Emissions of a City-Buses Fuelled by Diesel, CNG, and LPG Using a Mobile Emission Laboratory (이동형 배출가스 측정시스템(MEL)을 이용하여 디젤, CNG, LPG 시내버스에서 배출되는 입자상 물질 평가)

  • Lee, Seok-Hwan;Kim, Hong-Suk;Park, Jun-Hyuk;Yoon, Jun-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.409-416
    • /
    • 2011
  • A mobile emission laboratory (MEL) was designed to measure the amount of traffic pollutants with high temporal and spatial resolution under real conditions. Equipment for gas-phase measurements of quantity of CO, NOx, $CO_2$, and THC and for the measurement of the number density and size distribution of fine and ultra-fine particles by a FMPS and a CPC were placed in a mini-van. The exhaust of different type of vehicles can be sampled by MEL. This paper describes the construction and technical details of the MEL and presents data from the experiment in which a car chases city buses fuelled by diesel, CNG, and LPG. The diameters of most particles in the exhaust of the diesel city bus were less than 300 nm and most of the particles had a diameter of 30-60 nm. However, most particles in the exhaust of the CNG and LPG city buses were nanoparticles (diameter: less than 50 nm).

EXPLORING THE FUEL ECONOMY POTENTIAL OF ISG HYBRID ELECTRIC VEHICLES THROUGH DYNAMIC PROGRAMMING

  • Ao, G.Q.;Qiang, J.X.;Zhong, H.;Yang, L.;Zhuo, B.
    • International Journal of Automotive Technology
    • /
    • v.8 no.6
    • /
    • pp.781-790
    • /
    • 2007
  • Hybrid electric vehicles(HEV) combined with more than one power sources have great potential to improve fuel economy and reduce pollutant emissions. The Integrated Starter Generator(ISG) HEV researched in this paper is a two energy sources vehicle, with a conventional internal combustion engine(ICE) and an energy storage system(batteries). In order to investigate the potential of diesel engine hybrid electric vehicles in fuel economy improvement and emissions reduction, a Dynamic Programming(DP) based supervisory controller is developed to allocate the power requirement between ICE and batteries with the objective of minimizing a weighted cost function over given drive cycles. A fuel-economy-only case and a fuel & emissions case can be achieved by changing specific weighting factors. The simulation results of the fuel-economy-only case show that there is a 45.1% fuel saving potential for this ISG HEV compared to a conventional transit bus. The test results present a 39.6% improvement in fuel economy which validates the simulation results. Compared to the fuel-economy-only case, the fuel & emissions case further reduces the pollutant emissions at a cost of 3.2% and 4.5% of fuel consumption with respect to the simulation and test result respectively.

Multi-agent Control for Wind Hybrid Power Systems (풍력 복합발전 시스템을 위한 멀티에이전트 제어)

  • Kang, Seung-Jin;Ko, Hee-Sang;Boo, Chang-Jin;Kim, Ho-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7451-7458
    • /
    • 2014
  • In this paper, the system modeling and multi-agent control algorithm in isolated wind hybrid power systems are proposed. The multi-agent control is a new type of the hybrid control method that is made up of wind turbine, diesel generator, battery, and dumpload. Fourteen different modes of operations of the wind hybrid power system are performed by wind speed changes and the SOC of battery. Simulation results show that the efficient operations under various wind variations in isolated wind hybrid power systems can be obtained using proposed algorithms.

Exposure Assessment of Dust, Ultra Fine Dust(Particulate Matter 2.5, PM2.5) and Black Carbon among Aircraft Cabin Cleaners (항공기 기내 청소노동자의 분진, 초미세먼지(PM2.5) 및 블랙카본 노출수준 평가)

  • Hyunhee Park;Sedong Kim;Sungho Kim;Seung-Hyun Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.171-187
    • /
    • 2023
  • Objectives: Aircraft cabin cleaning work is characterized by being performed within a limited time in a narrow and enclosed space. The objective of this study was to evaluate the exposure levels to dust, ultra fine dust(PM2.5) and black carbon(BC) among aircraft cabin cleaners. Methods: Active personal air sampling for respirable dust(n=73) and BC(n=47) was conducted during quick transit cleaning(cabin general and vacuum-specific) and seat cover replacement and total dust and PM2.5 were area-air-sampled as well. Also, size distribution of particle was identified with the cleaning workers targeted. Dusts were collected with PVC filters using gravimetric analysis. The concentration of PM2.5 and the particle size distribution were measured with real-time direct reading portable equipment using light scattering analysis. The concentration of BC was measured by aethalometer(filter-based real-time light absorption analysis instrument). Results: The geometric mean of respirable dust was the highest at vacuum cleaning as 74.4 ㎍/m3, following by replacing seat covers as 49.3 ㎍/m3 and cabin general cleaning as 47.8 ㎍/m3 . The arithmetic mean of PM2.5 was 4.83 ~ 9.89 ㎍/m3 inside the cabin, and 28.5~44.5 ㎍/m3 outside the cabin(from bus and outdoor waiting space). From size distribution, PM2.5/PM10 ratio was 0.54 at quick transit cleaning and 0.41 at replacing seat covers. The average concentration of BC was 2~7 ㎍/m3, showing a high correlation with the PM2.5 concentration. Conclusions: The hazards concentration levels of aircraft cabin cleaners were very similar to those of roadside outdoor workers. As the main source of pollution is estimated to be diesel vehicles operating at airports, and it is necessary to replace older vehicles, strengthen pollutant emission control regulations, and introduce electric vehicles. In addition, it is necessary to provide as part of airport-inftastructure a stable standby waiting space for aircraft cabin cleaners and introduce a systematic safety and health management system for all workers in the aviation industry.

Determination of polycyclic aromatic hydrocarbons (PAHs) in used lubricating car oils (차량용 폐윤활유에 함유된 다환 방향족 탄화수소 (PAHs)의 분석)

  • Yoo, Kwang-Sik;Jyoung, Ji-Young;Jeong, Seon-Yi;Woo, Sang-Beom
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.339-348
    • /
    • 2003
  • Determination of some PAHs in used engine oils have been carried out by extraction of the components into acetonitrile followed by GC/FID and synchronous spectrofluorimetric technique. 7 PAHs, such as acenaphthene (Ace), anthracene (Anth), benzo(a)pyrene (BaP), chrysene (Chry), phenanthrene (Phen), fluoranthene (Ft), and perlyrene (Per) in used engine oil sample were able to determine separately by synchronous spectrofluorimetry. Calibration curves for those components were linear for the concentration range of 0.4~166 ppb PAHs with the corelation factor of 0.9985~0.9999. The peak areas produced by GC/FID split ratio program were used for the calibration curves of the other 8 PAHs. Detection sensitivity of the synchronous spectrofluorimetry seems to be 100 times more sensitive than GC/FID method. The total amount of PAHs in the used engine oil were 5.5 ng/g for LNG (bus), 10.5 ng/g for LPG(taxi), 92.2 ng/g for gasoline-passenger car, and 130 ng/g for diesel trailer, respectively.