• 제목/요약/키워드: Dielectric resistance

검색결과 330건 처리시간 0.023초

구형 마이크로스트립 안테나의 H-Plane 상호결합 (H-Plane Coupling Between Rectangular Microstrip antennas)

  • 고지환;조영기;손현
    • 대한전자공학회논문지
    • /
    • 제22권6호
    • /
    • pp.46-52
    • /
    • 1985
  • 본 논문은 구형 마이크로스트립 안테나의 H-plane 상호결합에 관한 연구이다. 두 안테나의 상호결합을 계산하기 위해서 단일 마이크로스트립 패치의 교사저항을 구하였으며 결합된 전송선로를 even mode와 add mode로 분발하여 각 mode의 특성저항와 실효 유전률을 계산하였다. 이로부터 자계적으로 결합된 안테나를 S-band 주파수에서 S-parameter를 구한 결과 이론치와 실험치가 거의 일치함을 확인할 수 있었다.

  • PDF

플라즈마 표면처리에 따른 고분자절연재료용 유리섬유의 표면개질 (Surface Modification of Glass Fiber for Polymer Insulator by Plasma Surface Treatment)

  • 임경범;이덕출
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권5호
    • /
    • pp.206-206
    • /
    • 2003
  • It is hard to expect excellent electrical, mechanical and chemical properties from most of the composite materials presently used as insulators due to insufficient wettability property caused by the difference of interfacial properties between the matrix material and the reinforcer. Therefore, various interfacial coupling agents have been developed to improve the interfacial properties of composite materials. But if the wettable coupling agents are used outdoor for a long time, change in quality takes place in the coupling agents themselves, bringing about deterioration of the properties of the composite materials. In this study, glass surface was treated by plasma to examine the effect of dry interface treatment without coupling agent. It was identified that the optimum parameters for the best wettability of the samples at the time of generation of plasma were oxygen atmosphere, 0.1 torr of system pressure, 100 W of discharge power, and 3 minutes of discharge time. Also, the surface resistance rate and dielectric property were improved.

Cross Linked Polyethylene의 물리적 및 화학적 성질 (Physical and Chemical Properties of Cross Linked Polyethylene)

  • 김한주;김규식;박종은;박수길;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.516-519
    • /
    • 1999
  • XLPE (Cross-Linked Polyethylene) which has good electric and physical characteristic is ideal material for Insulating material with force high volumetric resistance arid high dielectric constant. We study abort electric characteristics of XLPE by DCP and TMPTA content ration. DCP (Dicumylperoxide), which was used cross-linked agent contest, was changed from 1.0 to 0.5phr. TMPTA (Trimethyl-olpropane), which was used co cross-linked agent content, was changed from 0.5 to 1.5phr. Thermal analysis by DSC in order to observe tendency of Tg according to DCP and TMPTA content. Specimen 3 that content DCP 2.0phr and TMPTA 0.5phr has the highest value Breakdown strength cf specimen 3 (DCP 2.Ophr, TMPTA 1.0phr) is the highest, value and it increased in specific inductive capacity. This due to difference from cross-linked state by DCP and TMPTA content ratio.

  • PDF

다중 응력 변화에 따른 에폭시 복합체의 내크랙성 및 절연 파괴 특성 (The Crack Resistance and the Dielectric Breakdown properties of Epoxy Composities due to the Multi Stresses Variation)

  • 송봉철;김상걸;안준호;김충혁;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.136-139
    • /
    • 2000
  • Epoxy materials are used as insulation material for electric power cables. In the case of a flow of excess current due to the temperature difference which occurs between the heat of the conductor and the atmosphere, heat degrades connection point of the cables. Also, the mechanical stress, which occurs due to the thermal expansion coefficient of cable connection electrode system and epoxy insulation materials along with the gap between thermal conduction based on the extra high voltage of transmitted voltage, increases possibility of cracks to occur. The relationship between mechanical stress and electrical breakdown mechanism is verified for the epoxy materials such as high toughness epoxy materials, which comes to be used contemporarily, and for the breakdown mechanism of epoxy materials on the multi-stresses (mechanical and electrical) due to the variation of the temperature.

  • PDF

전기철도용 견인전동기의 복합가속열화 상태진단에 관한 연구 (A Study on the Complex Accelerating Degradation and Condition Diagnosis of Traction Motor for Electric Railway)

  • 왕종배
    • 한국전기전자재료학회논문지
    • /
    • 제15권1호
    • /
    • pp.93-101
    • /
    • 2002
  • In this study, the stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the C-Class(200$\^{C}$ ) insulation system of traction motors. The complex accelerative degradation was periodically performed during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, the condition diagnosis test such as insulation resistance '||'&'||' polarization index, capacitance '||'&'||' dielectric loss and partial discharge properties were investigated in the temperature range of 20 ∼ 160$\^{C}$. Relationship among condition diagnosis tests was analyzed to find a dominative degradation factor and an insulation state at end-life point.

플라즈마 표면처리에 따른 고분자절연재료용 유리섬유의 표면개질 (Surface Modification of Glass Fiber for Polymer Insulator by Plasma Surface Treatment)

  • 임경범;이덕출
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권5호
    • /
    • pp.206-212
    • /
    • 2003
  • It is hard to expect excellent electrical, mechanical and chemical properties from most of the composite materials presently used as insulators due to insufficient wettability property caused by the difference of interfacial properties between the matrix material and the reinforcer. Therefore, various interfacial coupling agents have been developed to improve the interfacial properties of composite materials. But if the wettable coupling agents are used outdoor for a long time, change in quality takes place in the coupling agents themselves, bringing about deterioration of the properties of the composite materials. In this study, glass surface was treated by plasma to examine the effect of dry interface treatment without coupling agent. It was identified that the optimum parameters for the best wettability of the samples at the time of generation of plasma were oxygen atmosphere, 0.1 torr of system pressure, 100 W of discharge power, and 3 minutes of discharge time. Also, the surface resistance rate and dielectric property were improved.

SiO/TiN 박막의 증착두께에 따른 유전율 특성 (Permittivity Characteristics of SiO/TiN Thin Film according to Coating Thickness)

  • 김창석;이우선;정천옥;김병인
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권6호
    • /
    • pp.570-575
    • /
    • 1997
  • In this days, the thinner film of dielectric materials is required while its capacitance is required to be still large at the VLSI process. Most of such VLSI have MOS structures. For the research on this requirement, MOS capacitors were fabricated on the silicon wafer in four different thickness groups by RF sputtering method. SiO of the SiO/TiN film is used as the insulating layer and TiN is chosen as the barrier against the diffusion of Al which is the terminal connected by ohmic contact because TiN has the advantageous properties such as good thermal stability and very low diffusion rate in spite of its relatively low specific resistance. In this study their electrical and optical characteristics are investigated to find refractive index, absorption coefficient and Permittivity.

  • PDF

Theoretical Aspects of PTC Thermistors

  • Cho, Sang-Hee
    • 한국세라믹학회지
    • /
    • 제43권11호
    • /
    • pp.673-679
    • /
    • 2006
  • The discovery of ferroelectric barium titanate (BaTiO$_3$) in 1942 began the present era of dielectrics-based electronic ceramics. Ferroelectric barium titanate has a high dielectric constant and after the recognition of BaTiO$_3$ as a new ferroelectric compound, various attractive electrical properties have been extensively studied and reported. Since then, pioneering work on valence-compensated semiconduction led to the discovery of the positive temperature coefficient (PTC) of the resistance effect found in doped BaTiO$_3$. Significant progress has since followed with respect to understanding the PTC phenomena, advancing materials capabilities, and developing devices for sensor and switching applications. In this paper, the theoretical aspects of the various PTC models are discussed and the future trends of practical applications for PTC devices are briefly mentioned.

반응성 스퍼트링에 의한 ITO의 형성과 유전체 소성공정중의 특성변화에 관한 연구 (The Effect of Dielectric Firing Process in PDP on the Properties of ITO Prepared by Reactive RF Sputtering)

  • 남상옥;지성원;손제봉;조정수;박정후
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.510-514
    • /
    • 1997
  • The thin film that is electrically conductive and optically transparent is called conductive transparent thin film. ITO(Indium-Tin Oxide) which is a kind of conductive transparent thin film has been widely used in solar cell, transparent electrical heater, selective optical filter, FDP(Flat Display Panel) such as LCD(Liquid Crystal Display), PDP(Plasma Display Panel) and so on. Especially in PDP, ITO films is used as a transparent electrode in order to maintain discharge and decrease consumption power through the improvement of cell structure. In this study, we prepared ITO by reactive r.f. sputtering with indium-tin(Sn 10wt%) alloy target instead of indium-tin oxide target. The ITO films deposited at low temperature 15$0^{\circ}C$ and 8% $O_2$. Partial pressure showed about 3.6 Ω/$\square$. At the end of firing, the resistance of ITO was decreased, the optical transparence was improved above 90%.

  • PDF

견인전동기의 복합가속열화 상태진단에 의한 고장예측 및 신뢰성 평가 (Fault Prediction & Reliability Estimation of the Traction Motor by the Complex Accelerating Degradation and Condition Diagnosis)

  • 왕종배;김명룡
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.763-766
    • /
    • 2000
  • In this paper, stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the 200 Class insulation system of traction motors. The complex accelerative degradation was performed by periods during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of 20∼160$^{\circ}C$. Relationship among condition diagnosis test was analyzed to find an dominative degradation factor and an insulation state at end-life point.

  • PDF