• 제목/요약/키워드: Dielectric Barrier Discharge Plasma

검색결과 204건 처리시간 0.034초

대기압 플라즈마 설비 개발 및 Flip Chip BGA 제조공정 적용 (Development of Atmospheric Pressure Plasma Equipment and It's Application to Flip Chip BGA Manufacturing Process)

  • 이기석;유선중
    • 반도체디스플레이기술학회지
    • /
    • 제8권2호
    • /
    • pp.15-21
    • /
    • 2009
  • Atmospheric pressure plasma equipment was successfully applied to the flip chip BGA manufacturing process to improve the uniformity of flux printing process. The problem was characterized as shrinkage of the printed flux layer due to insufficient surface energy of the flip chip BGA substrate. To improve the hydrophilic characteristics of the flip chip BGA substrate, remote DBD type atmospheric pressure plasma equipment was developed and adapted to the flux print process. The equipment enhanced the surface energy of the substrate to reasonable level and made the flux be distributed over the entire flip chip BGA substrate uniformly. This research was the first adaptation of the atmospheric pressure plasma equipment to the flip chip BGA manufacturing process and a lot of possible applications are supposed to be extended to other PCB manufacturing processes such as organic cleaning, etc.

  • PDF

유전체장벽 방전구조의 비접촉식 저온 대기압 면방전 플라즈마를 이용한 빵곰팡이의 살균효과 (Sterilization of Neurospora Crassa by Noncontacted Low Temperature Atmospheric Pressure Surface Discharged Plasma with Dielectric Barrier Structure)

  • 유영효;엄환섭;박경순;최은하
    • 한국진공학회지
    • /
    • 제22권2호
    • /
    • pp.55-65
    • /
    • 2013
  • 본 연구에서는, 동시에 넓은 면적을 조사할 수 있는 형태의 유전체 장벽 방전을 이용한 대기압 면방전 플라즈마 발생장치를 이용하여 곰팡이의 살균 실험을 수행하였다. 실험에 사용한 면방전 플라즈마 발생장치의 파워는 사인파 교류전원을 이용하였으며, 1.4~2.3 kV의 방전전압을 가진다. 또한, 유전체 전기용량의 특성으로 인하여 전압과 전류의 위상차는 약 80도를 갖는다. 생물시료에 미치는 온도의 영향은 공랭식 쿨러를 사용하여 유전체의 열을 배출함으로써 최소화 하였으며, 시료의 온도는 온도측정장치를 사용하여 쿨러(Cooler) 작동 시 최대 10분간 플라즈마를 발생시켜도 37도가 넘지 않음을 확인하였다. 플라즈마에서 생성되는 활성종중 오존($O_3$)의 양은 플라즈마 발생부로부터 1 cm 이내에서 약 25~30 ppm이 측정되었으며, 150 cm 떨어진 지점에서도 5 ppm 정도 측정되었다. 그에 비해 일산화질소(NO)나 이산화질소($NO_2$)는 거의 검지되지 않음을 확인하였다. 증류수 속에 담긴 빵 곰팡이 포자를 면방전 플라즈마 발생장치로 처리하였을 때, 포자의 발아율은 처리시간 및 출력파워가 증가함에 따라 급격히 감소하였으며, MTT (3-(4,5-dimethy lthiazol-2yl)-2,5-diphenyl-2H-tetrazolium bromide) 측정법을 통해 분석한 미토콘드리아 활성도도 처리시간과 출력파워에 비례하여 감소함을 보았다. 반면 포자를 Vogel's minimal 배양액에 넣고 플라즈마 처리를 하면, 앞의 실험과 달리 살균효과가 미비함을 보였는데, 이를 통해 포자를 둘러싸고 있는 환경이 플라즈마의 살균효과에 영향을 미치는 것으로 보여진다. 본 연구를 통하여 유전체 장벽을 이용한 면방전 플라즈마 발생장치는 플라즈마 제트(jet)와는 달리 직접적인 접촉 없이도 미생물 살균이 가능하다는 것을 보여주었으며, 이는 면방전 플라즈마 발생장치로부터 발생하는 활성종들이 곰팡이와 같은 미생물의 비활성화에 주요역할을 하기 때문이라고 본다.

High luminous efficiency Mercury-free flat light source for LCD BLU

  • Lee, Ju-Kwang;Oh, Byung-Joo;Jung, Jae-Chul;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1161-1164
    • /
    • 2005
  • A Mercury-free, flat light source which shows high luminance and luminous efficiency simultaneously has been developed. An electrodeless, dielectric barrier discharge is used to generate the plasma using Ne-Xe mixture gas of relatively low gas pressure of a few tens torr in a 4.1 inch diagonal size of flat panel. The basic properties of the long gap glow discharge and its accompanying instabilities, which prevents us from having high luminous efficiency discharge have been analyzed. A new structure and optimized driving methods have been used to generate a glow discharge which shows a wide voltage margin of a few hundred volts. The luminous efficiency and luminance could be 110 lm/W at $1300\;cd/m^2$ and 50 lm/W at $5500\;cd/m^2$.

  • PDF

Discharge analysis of SrO- and SrCaO-PDP operated at lower voltage

  • Uchida, G.;Uchida, S.;Yano, T.;Awaji, N.;Kajiyama, H.;Shinoda, T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.177-180
    • /
    • 2009
  • Here is presented the measurement on SrO- and SrCaO-PDP operated at lower voltage. SrO- and SrCaO-PDP attain high luminous efficacy at low voltage, where the breakdown voltage is 30 % lower than that of the ordinary MgO-PDP. A one-dimensional fluid model is applied for the simulation of PDP discharge. High VUV radiation efficiency is confirmed at high ${\gamma}_i$ and both low and high $V_s$ as in the experiment. Discharge analysis in simulation also shows that the high ${\gamma}_i$ protective layer leads to high plasma density especially near the cathode electrode, being responsible for high efficiency.

  • PDF

Electroless Ni Plating on PC to Improve Adhesion by DBD Plasma Treatment

  • Song, T.H.;Lee, J.K.;Park, S.Y.
    • Corrosion Science and Technology
    • /
    • 제4권6호
    • /
    • pp.222-225
    • /
    • 2005
  • The adhesion strength of metal plating on PC was studied. In this study, surface was treated by chemical agents or DBD(dielectric barrier discharge) plasma to imporve the adhesion. The surface roughness, contact angle, gloss of plating and adhesive strength were measured. Adhesion strengths of Ni plating on prepared PC by NaOH and KOH solution were $12.3kgf/cm^2$ and $7.5kgf/cm^2$, respectively. The highest adhesion strength was obtained in the plasma treated one, $27.8kgf/cm^2$.

Enhanced performance at an early state of hydrocarbon selective catalyst reduction of NOx by atmospheric pressure plasma

  • Nguyen, Duc Ba;Heo, Il Jeong;Mok, Young Sun
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제68권
    • /
    • pp.372-379
    • /
    • 2018
  • The improvement of $NO_x$ reduction by $Ag/{\gamma}-Al_2O_3$ with a hydrocarbon ($n-C_7H_6$) in the early state was investigated in a packed-bed dielectric barrier discharge plasma reactor. The results revealed that the combination of plasma with the catalyst enhanced $NO_x$ reduction efficiency at low operating temperatures, depending on the temperature and specific input energy. To sum up, the poor performance of the catalytic $NO_x$ reduction at low temperatures in the early stage before reaching thermochemical steady state can be greatly compensated for by using the atmospheric-pressure plasma generated in the catalyst bed.

펄스변조의 듀티비 변경에 따른 DBD 대기압 플라즈마 특성 연구 (Study on the Atmospheric Plasma Characteristics of Dielectric Barrier Discharge due to a Variation of the Duty Ratio of Pulse Modulation)

  • 박종인;황상혁;조태훈;윤명수;곽형신;진기남;전부일;최은하;권기청
    • 한국재료학회지
    • /
    • 제25권11호
    • /
    • pp.616-621
    • /
    • 2015
  • Atmospheric pressure plasma is used in the biological and medical fields. Miniaturization and safety are important in the application of apply atmospheric plasma to bio devices. In this study, we made a small, pocket-sized inverter for the discharge of atmospheric plasma. We used pulse power to control the neutral gas temperature at which the, when plasma was discharged. We used direct current of 5 V of bias(voltage). The output voltage is about 1 to 2 kilo volts the frequency is about 80 kilo hertz. We analyzsed the characteristics of the atmospheric plasma using OES(Optical emission spectroscopy) and the Current-Voltage characteristic of pulse power. By calculating of the current voltage characteristics, we were able to determine that, when the duty ratio increased, the power that actually effects the plasma discharge also increased. To apply atmospheric plasma to human organisms, the temperature is the most important factor, we were able to control the temperature by modulating the pulse power duty ratio. This means we can use atmospheric plasma on the human body or in other areas of the medical field.

배리어 유전체 방전형 2단 전기집진기의 나노입자 집진 및 잔류 오존 제거 특성 (Characteristics of Nano Particle Precipitation and Residual Ozone Decomposition for Two-Stage ESP with DBD)

  • 변정훈;지준호;윤기영;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1678-1683
    • /
    • 2003
  • DBD(Dielectric Barrier Discharge) plasma in air is well established for the production of large quantities of ozone and is more recently being applied to aftertreatment processes for HAPs(Hazardous Air Pollutants). Although DBD high electron density and energy, its potential use as nano and sub-micron sized particle charging are not well known. Aim of this work is to determine design and operating parameters of a two-stage ESP with DBD. DBD and ESP are used as particle charger and precipitator, respectively. We measured particle precipitation efficiency of two-stage ESP and estimated ozone decomposition of both pelletized $MnO_2$ catalyst and pelletized activated carbon. To examine the particle precipitation efficiency, nano and sub-micron sized particles were generated by a tube furnace and an atomizer. AC voltage of $7{\sim}10$ kV(rms) and 60 Hz is used as DBD plasma source. DC -8 kV is applied to the ESP for particle precipitation. The overall particle collection efficiency for the two-stage ESP with DBD is over 85 % under 0.64 m/s face velocity. Ozone decomposition efficiency with pelletized $MnO_2$ catalyst or pelletized activated carbon packed bed is over 90 % when the face velocity is under 0.4 m/s in dry air.

  • PDF

대기압 플라즈마를 이용한 TiO2 광촉매의 효율향상을 위한 표면 개질 연구 (Surface Modification of TiO2 by Atmospheric Pressure Plasma)

  • 조상진;정충경;김성수;부진효
    • 한국진공학회지
    • /
    • 제19권1호
    • /
    • pp.22-27
    • /
    • 2010
  • $TiO_2$의 표면의 친수성을 증가시키기 위하여 dielectric barrier discharge (DBD)에 의해 발생된 대기압 플라즈마 (atmospheric pressure plasma: APP)를 이용 RF power 50~200 W 범위에서 Ar과 $O_2$ 가스를 사용 대기압 플라즈마로 광촉매 표면을 개질하였다. Ar 가스 단독으로 처리한 시료의 접촉각은 20도에서 10도로 감소하였으며, $O_2$ 가스를 반응성 가스로 하여 처리한 경우에는 접촉각이 20도에서 1도 미만으로 감소하였다. 동일한 RF power에서 $O_2$ 플라즈마 처리 시 더 낮은 접촉각을 확인하였는데, 이는 $TiO_2$ 표면과 산소원자의 결합으로 인하여 표면의 polar force의 증가에 의한 것으로 판단되어 대기압 플라즈마로 처리된 시료의 X-ray photoelectron spectroscopy (XPS)의 스펙트럼 분석결과 OH 작용기의 증가로 표면의 친수성이 증가됨을 확인하였다. 대기압 플라즈마로 처리된 시료와 처리하지 않은 시료의 접촉각은 모두 시간이 지남에 따라 증가하지만 플라즈마 처리 된 시료의 접촉각 증가는 플라즈마 처리하지 않은 시료의 접촉각 보다 작은 것을 확인하였다. 또한, 페놀 분해 실험을 통하여 플라즈마 표면처리를 통하여 $TiO_2$ 광촉매의 분해 효율이 크게 향상되는 것을 확인하였다.

DBD를 이용한 Plasma Jet의 구동 전극 위치에 따른 방전 특성 분석

  • 이영호;하창승;이호준;김동현;이해준
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.226-226
    • /
    • 2011
  • 소형 대기압 플라즈마 소스는 그 형태에 따라 DBD (Dielectric Barrier Discharge)나 Plasma Needle, 혹은 Plasma Jet 등으로 구별되며, 구동 파형의 특성에 따라 DC, RF (Radio Frequency), 혹은 Pulsed 방식 등으로 나뉜다. 또한 코로나 방전도 소형 대기압 플라즈마 장치에서 사용된다. DBD는 1857년 Siemens에 의해 최초로 보고 되었고 산업 분야에서 대규모로 사용되어 왔다. 본 연구에서는 대향 방전 DBD 대신 유전체 양쪽 면에 전극이 도포된 면방전 형태의 DBD 구조 내부로 He 가스가 흐를 때의 방전에 대한 광학적 진단을 수행하였다. 전극간의 거리와 가스 유속의 변화에 따라 방전 특성이 어떻게 달라지에 대해서 Optical Emission Spectroscopy (OES)를 통하여 생성되는 radical 종의 변화를 측정하고 ICCD (intensified charge coupled device) image를 통해 방전이 시간에 따라 어떻게 진행되는지를 진단하였다.

  • PDF