• Title/Summary/Keyword: Dichroic Filter

Search Result 10, Processing Time 0.018 seconds

Colorimetric Design of Dichroic Mirrors in 3-LCD Projection Systems (3판식 액정 프로젝션 시스템의 다이크로익 미러의 색채학적 설계)

  • Kim, Jee-Hong
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.9
    • /
    • pp.70-77
    • /
    • 1998
  • A new method is proposed for the design of the dichroic mirrors in 3-LCD projection systems for color separation/composition. Rather than simply basing the color performance criterion on luminance or chromatic saturation only, the optimum design parameters can be found by maximizing the perceived color gamut in a 3-D uniform color space. In this method, the half-power wavelengths were optimized by maximizing the volume of the reproducible color gamut in a CIELUV uniform color space for 2 typical viewing conditions, with proper colorimetric analysis of color reproduction in 3-LCD projection systems.

  • PDF

A study on the application of dichroic mirror for the improvement of luminance and luminous efficacy in an AC Plasma Display Panel (AC-PDP의 휘도와 효율 향상을 위한 Dichroic Mirror의 응용에 관한 연구)

  • 송병무;김중균;황만수;황기웅
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.98-103
    • /
    • 2001
  • A new application of dirchroic mirror for the improvement of luminance and luminous efficacy in an AC-Plasma Display Panel (PDP) is suggested. Only about half of the Vacuum Ultraviolet (VUV) generated in the reflective PDP cell is used for the excitation of the phosphor. We are suggesting an idea of adopting a dichroic mirror which can reflect the VUV toward the phosphor which otherwise is absorbed by the front panel. The optical constants of the thin films of dirhroic mirror were determined from the photometric measurements through an iteration process of matching calculated and measured values of the reflectance and transmittance in the VUV wavelength region. From these results, we could design such a filter whose high reflection zone is centered at 147nm by a computer simulation accurately. The 147nm VUV is radiated from Xenon 3Pl state which is dominantly used to activate the phosphor in the PDP cell. The dichroic mirror was made with an electronbeam evaporator and its reflectance was measured by a reflectometer. We confirmed the usefulness of the dichroic mirror for the improvement of efficiency with experiments done by test panels. The panel with mirror shows improved luminance and luminous efficacy by 20∼30%.

  • PDF

Development of visible light stimulation system for color therapy (색채치료에 이용되는 가시광선 제시 시스템 개발)

  • 오성섭;양길태;유충기;홍철운;송철규;김남균;이강민
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.215-218
    • /
    • 2001
  • 본 연구는 가시광선영역에서 각각의 색을 구현하여 색채치료에 이용하기 위한 시스템을 개발하는데 있다. 사용된 광원은 에너지 밀도가 전파장에 걸쳐서 일정한 Dichroic reflector hallogen lamp를 사용하였고, 광원에서 발생하는 적외선을 차단하기 위하여 IR filter를 사용하였다. 색채치료에 사용 가능한 순수한 파장의 색을 분리하기 위하여 long pass filter와 short pass filter로 구성되는 color filter set를 사용하여 구성하였다. 개발된 가시광선 제시 시스템은 빨강, 파랑, 노란 광을 낼 수 있도록 되어 있으며 각각의 광도는 2390 lx, 1020 lx, 17400 lx이다. 개발된 시스템의 객관적 효과를 검증하기 위하여 피부 서식균으로 항균 실험을 하나 결과 노란 광이 빨강이나 파란 광에 비해 세포성장 억제가 컸다. 대식세포와 피부암세포로 실시한 항염 실험은 각각의 색광에 대한 영향이 크지 않았다.

  • PDF

Design and Fabrication of Reflection-type Pump LD Protection Filters for High Power Fiber Lasers by Using Ta2O5/SiO2 Thin Films (Ta2O5/SiO2를 이용한 고출력 광섬유 레이저의 펌프 LD 보호기용 반사형 필터 설계 및 제작)

  • Sung, Hamin;Kim, Jae Hun;Lee, Seok;Jhon, Young Min
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.3
    • /
    • pp.124-127
    • /
    • 2012
  • We designed and fabricated dichroic filters for high-power fiber lasers to protect the pumping laser diode from counterpropagating laser beams. The transmittance at laser diode wavelengths of 905 nm~925 nm was designed to be less than 0.1% and the transmittance at the fiber laser or Brillouin scattering wavelengths of 1020 nm ~ 1100 nm was designed to be more than 99.9%. Since oxide materials have good adhesion to the $SiO_2$ substrate, $SiO_2/Ta_2O_5$ were used as coating materials. The filter was fabricated according to our optimized design and its characteristics were compared with the theoretical design. As a result, the transmittance at laser diode wavelengths of 905 nm~925 nm was measured to be less than 0.1%, and the transmittance at the fiber laser or Brillouin scattering wavelengths of 1020 nm~1100 nm was measured to be more than 95.5%, which coincided well with the theoretical design considering processing errors. The filter was found to operate well over 1W of input laser power.

Application Feasibility Study of Non-local Means Algorithm in a Miniaturized Vein Near-infrared Imaging System (정맥 관찰용 소형 근적외선 영상 시스템에서의 비지역적평균 알고리즘 적용 가능성 연구)

  • Hyun-Woo Jeong;Youngjin Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.679-684
    • /
    • 2023
  • Venous puncture is widely used to obtain blood samples for pathological examination. Because the invasive venipuncture method using a needle is repeatedly performed, the pain suffered by the patient increases, so our research team pre-developed a miniaturized near-infrared (NIR) imaging system in advance. To improve the image quality of the acquired NIR images, this study aims to model the non-local means (NLM) algorithm, which is well known to be efficient in noise reduction, and analyze its applicability in the system. The developed NIR imaging system is based on the principle that infrared rays pass through dichroic and long-pass filters and are detected by a CMOS sensor module. The proposed NLM algorithm is modeled based on the principle of replacing the pixel from which noise is to be removed with a value that reflects the distances between surrounding pixels. After acquiring an NIR image with a central wavelength of 850 nm, the NLM algorithm was applied to segment the final vein area through histogram equalization. As a result, the coefficient of variation of the NIR image of the vein using the NLM algorithm was 0.247 on average, which was an excellent result compared to conventional filtering methods. In addition, the dice similarity coefficient value of the NLM algorithm was improved by 62.91 and 9.40%, respectively, compared to the median filter and total variation methods. In conclusion, we demonstrated that the NLM algorithm can acquire accurate segmentation of veins acquired with a NIR imaging system.

Design and Development of a Single-photon Laser and Infrared Common Aperture Optical System

  • Wu, Hongbo;Zhang, Xin;Tan, Shuanglong;Liu, Mingxin;Wang, Lingjie;Yan, Lei;Liu, Yang;Shi, Guangwei
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.171-182
    • /
    • 2022
  • A single-photon laser and mid-wave infrared (MWIR) common aperture optical system was designed and developed to detect and range a long-distance civil aviation aircraft. The secondary mirror of the Ritchey-Chretien (R-C) optical system was chosen as a dichroic lens to realize the design of a common aperture system for the laser and MWIR. Point spread function (PSF) ellipticity was introduced to evaluate the coupling efficiency of the laser receiving system. A small aperture stop and narrow filter were set in the secondary image plane and an afocal light path of the laser system, respectively, and the stray light suppression ability of the small aperture stop was verified by modeling and simulation. With high-precision manufacturing technology by single point diamond turning (SPDT) and a high-efficiency dichroic coating, the laser/MWIR common aperture optical system with a 𝜑300 mm aluminum alloy mirror obtained images of buildings at a distance of 5 km with great quality. A civil aviation aircraft detection experiment was conducted. The results show that the common aperture system could detect and track long-distance civil aviation aircraft effectively, and the coverage was more than 450 km (signal-to-noise ratio = 6.3). It satisfied the application requirements for earlier warning and ranging of long-range targets in the area of aviation, aerospace and ground detection systems.

A Study on Electro-Optical Characteristics of the TN Cell Photoaligned on the Ν-(phenyl)maleimide Surface using the UVLPH Photodimerization Method (Ν-(phenyl)maleimide 표면에 UVLPH 광중합법을 이용한 광배향 TN 셀의 전기광학특성에 관한 연구)

  • 황정연;김준영;김태호;서대식;김영식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.8
    • /
    • pp.731-735
    • /
    • 2002
  • Electro-optical (EO) performances for the twisted-nematic (TN)-liquid crystal display (LCD) photoaligned with linearly polarized UV exposure on the poly[4- (fluorocinnamate) phenylmaleimide](PFCPMI) surfaces using a new photodimerization method were investigated. For a new UVLPH (UV linearly polarized during heating) photodimerization method, the photopolymer layers were exposed by linearly polarized UV dichroic polarizer without a specific UV filter during heating at $150^{\circ}C$. The Voltage-transmittance (V-T) curve without backflow bounce in the photoaligned TN-LCD with UV exposure on the PFCPMI surface for 10 min using the UVLPH photodimerization method was observed. For response time measurement, the transmittance characteristics of the photoaligned TN-LCD using the UVLPH photodimerization method on the photopolymer surface was better than that of the photoaligned TN-LCD using the UVLP photodimerization method under a room temperature.

Developing Head/Eye Tracking System and Sync Verification (헤드/아이 통합 트랙커 개발 및 통합 성능 검증)

  • Kim, Jeong-Ho;Lee, Dae-Woo;Heo, Se-Jong;Park, Chan-Gook;Baek, Kwang-Yul;Bang, Hyo-Choong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.90-95
    • /
    • 2010
  • This paper describes the development of integrated head and eye tracker system. Vision based head tracker is performed and it has 7mm error in 300mm translation. The epi-polar method and point matching are used for determining a position of head and rotational degree. High brightness LEDs are installed on helmet and the installed pattern is very important to match the points of stereo system. Eye tracker also uses LED for constant illumination. A Position of gazed object(3m distance) is determined by pupil tracking and eye tracker has 1~5 pixel error. Integration of result data of each tracking system is important. RS-232C communication is applied to integrated system and triggering signal is used for synchronization.

Feasibility of simultaneous measurement of cytosolic calcium and hydrogen peroxide in vascular smooth muscle cells

  • Chang, Kyung-Hwa;Park, Jung-Min;Lee, Moo-Yeol
    • BMB Reports
    • /
    • v.46 no.12
    • /
    • pp.600-605
    • /
    • 2013
  • Interplay between calcium ions ($Ca^{2+}$) and reactive oxygen species (ROS) delicately controls diverse pathophysiological functions of vascular smooth muscle cells (VSMCs). However, details of the $Ca^{2+}$ and ROS signaling network have been hindered by the absence of a method for dual measurement of $Ca^{2+}$ and ROS. Here, a real-time monitoring system for $Ca^{2+}$ and ROS was established using a genetically encoded hydrogen peroxide indicator, HyPer, and a ratiometric $Ca^{2+}$ indicator, fura-2. For the simultaneous detection of fura-2 and HyPer signals, 540 nm emission filter and 500 nm~ dichroic beamsplitter were combined with conventional exciters. The wide excitation spectrum of HyPer resulted in marginal cross-contamination with fura-2 signal. However, physiological $Ca^{2+}$ transient and hydrogen peroxide were practically measurable in HyPer-expressing, fura-2-loaded VSMCs. Indeed, distinct $Ca^{2+}$ and ROS signals could be successfully detected in serotonin-stimulated VSMCs. The system established in this study is applicable to studies of crosstalk between $Ca^{2+}$ and ROS.

AN EXPERIMENTAL STUDY OF THE IRRADIATION EFFECTS ON RAT PAROTID GLAND (방사선조사가 백서 이하선에 미치는 영향에 관한 실험적 연구)

  • Lee Kyu Chan;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.16 no.1
    • /
    • pp.49-58
    • /
    • 1986
  • This study was designed to investigate the irradiation effects on the rat parotid gland, applied to the head and neck region. For this experiment, twenty-four rats, feeded under the even condition, were used as experimental animals. Twenty rats were used for experimental group and the rest were assigned to the control group. The experimental group was singly irradiated with 10Gray through Cobalt-60 radiotherapy device, Picker model 4M 60 (Field size; l2×5㎝, SSD; 50㎝, Depth; 1㎝). The experimental animals of both group were sacrificed each four animals in 2 days, 1week, 2weeks, 3weeks and 4weeks after irradiation. The specimens were examined through the light microscope using the H-E stain and H stain by routin procedure. The other specimens were observed under the fluorescence microscope using the B-O dichroic mirror and Y455 barrier filter after PA-ACH stain. 1. The results of this study were obtained as follows, The parotid acini were severely degenerated and the intraacinar spaces were widened. Within the acini, retained secretory granules and increased fibrosis were observed. Also the shape and the size of the acini showed very irregular atrophic degenerations. 2. The nuclei showed severe pyknosis, displacement and irregular aggregated appearance. 3. The tissue changes of the parotid acini were initiated after 2 days of irradiation and most severely appeared at the second week of irradiation, but almost returned to normal. 4. The salivary ducts of the parotid gland were severely atrophied, discontinued but initiated to regenerated after 3 weeks of irradiation.

  • PDF