• Title/Summary/Keyword: Dibutyl phthalate(DBP)

Search Result 36, Processing Time 0.019 seconds

Study on Current Collector for All Vanadium Redox Flow Battery (전바나듐계 레독스플로우전지용 집전체에 대한 연구)

  • Choi, Ho-Sang;Hwang, Gab-Jin;Kim, Jae-Chul;Ryu, Cheol-Hwi
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.2
    • /
    • pp.240-248
    • /
    • 2011
  • All-vanadium redox flow battery (VRFB) has been studied actively as one of the most promising electrochemical energy storage systems for a wide range of applications such as electric vehicles, photovoltaic arrays, and excess power generated by electric power plants at night time. Among consisting elements of the VRFB, the ion exchange membrane and the electrode play important roles. In this study, carbon PVC coposite sheets for the VRFB have been developed and electrochemical characteristics investigated. Current collector for VRFB, carbon PVC composite sheets (CPCS), were prepared with G-1028 as a conducting particle, PVC as a polymer, Dibutyl phthalate (DBP) as a plasticizer and fumed Silica (FS) as a dispersion agent. CPCS has been shown to have the characteristics as an excellent current collector for VRFB and electrochemical properties of specific resistivity 0.31 ${\Omega}cm$, which were composed of G-1028 80 wt%, PVC 10 wt%, DBP 5 wt% and FS 5 wt%.

Simple Method in Trace Analysis of Phthalates in Cosmetics : Analytical Conditions and Skills for Better Results (화장품에서 프탈레이트 미량분석을 위한 간편한 분석법 : 향상된 결과를 위한 분석조건과 기술)

  • Kim, Min-Kee;Jung, Hye-Jin;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.1
    • /
    • pp.51-55
    • /
    • 2008
  • Although phthalates aren't used as an cosmetic ingredient, some cosmetics especially nail lacquer, hair spray, and perfume still have phthalates. This is mainly caused by contamination and carryover during manufacturing process, so analysis of phthalates in those cosmetics has became a very important thing for quality-assurance(Q.A). The main phthalates under debate are diethyl phthalate(DEP), dibutyl phthalate(DBP), and bis(2-ethylhexyl) phthalate (DEHP) in domestic market. Gas chromatography-mass spectrometry(GC-MS) coupled with solvent extraction and concentration has been used for ppm level and sub ppm level analysis of phthalates. It requires much time and cost to use mass spectrometric detector and to prepare the test solution. Moreover analysis of phthalates at low concentrations is difficult because of contamination which results in wrong analytical results. In the present study, we showed a simple method using gas chromatography-flame ionization detector(GC-FID) which has fast analysis time, minimum use of solvent, reduced sample preparation steps for minimizing contamination and quantitative range of $2{\sim}50{\mu}g/g(ppm)$ in products. Consequently, this method will be proper for Q.A analysis in related companies.

The Composition Dependence Selectivity Changes by Plasticizer at the Cation Sensors Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Kim, Jin-San;Paeng, Insook Rhee;Paeng, Ki-Jung
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.165-167
    • /
    • 2008
  • The performances of tetracycline based cation selective polymeric membrane electrodes of many sets with different plasticizers were investigated as the selectivity of ion-selective electrodes and optodes are greatly influenced by membrane solvent and also controlled by plasticizers. The membrane 1 with Bis(2-ethylhexyl) sebacate (DOS) and additive shows good potentiometric performance toward Ca2+ (slope: 27.8 mV per decade; DL: -4.52) including selectivity. Contrastingly, membrane 4 with Dibutyl phthalate (DBP) shows near-Nernstian response, it has also shown the best measuring range and detection limit for Ca2+ (29.5 mV and -5.10) and Mg2+ (24.4 mV and -5.04) and the least selectivity has been also observed between Ca2+ and Mg2+. When the membrane 1 and 4 were used together to flow system, we could determine the concentration of Ca2+ and Mg2+, simultaneously.

Effect of Heat Capacity of Coagulant on Morphology of PVDF-Silica Mixture Through TIPS Process for the Application of Porous Membrane (다공성 분리막으로 응용을 위한 PVDF-실리카 혼합물의 응고액 열용량 변화에 따른 모폴로지 변화)

  • Lee, Jeong Woo;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.27 no.5
    • /
    • pp.458-467
    • /
    • 2017
  • In this study, we prepared PVDF membranes via TIPS for water treatment applications. PVDF was used for its excellent chemical and mechanical properties. The effect of coagulation bath composition, temperature, and heat capacity on the overall membrane morphology was studied and observed using SEM. A mixture of DOP and DBP was used as the diluent, and silica was used as an additive. It was observed that as the heat capacity of the coagulation bath increased, the crystallization rate of PVDF decreased yielding larger pores. Also, as the heat capacity of the coagulation bath decreased, the crystallization rate of PVDF increased yielding smaller pores.

The Potentiometric Performance of Mercury (II) Ion-Selective Electrode Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Rhee Paeng, In-Sook
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.59-63
    • /
    • 2008
  • Poly (vinylchloride) (PVC) membrane electrodes based on neutral carrier, tetracycline was prepared as an active sensor for Hg(II) ion, and tested in different contents of the potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as lipophilic salt. Bis (2-ethylhexyl) sebacate (DOS), bis(l-butylpentyl) adipate (BBPA), 2-nitrophenyl octyl ether (NPOE) and dibutyl phthalate (DBP) were used as diverse plasticizing solvent mediators. This electrode shows excellent potentiometric response characteristics and display good linearity with log $[Hg^{+2}]$ versus EMF response, over a range of concentrations between $10^{-7}$ and $10^{-3}M$. With 30.8mV/decade Nernstian slope, the detection limit was $6.9{\times}10^{-9}M$ and the response time was less than 20s. The proposed electrode yields very good selectivity for mercury (II) ion over many cations such as alkali, alkaline earth, transition and heavy metal ions. And it shows a very stable potential values in a wide pH range. This reliable electrode prepared was kept at least a month without considerable alteration in their response to Hg (II) ion.

Hormonal Effects of Several Chemicals in Recombinant Yeast, MCF-7 Cells and Uterotrophic Assays in Mice

  • Park, Jin-Sung;Lee, Beom-Jun;Kang, Kyung-Sun;Tai, Joo-Ho;Cho, Jae-Jin;Cho, Myung-Haing;Inoue, Tohru;Lee, Yong-Soon
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.3
    • /
    • pp.293-299
    • /
    • 2000
  • Many methods have been developed for screening chemicals with hormonal activity. Using recombinant yeasts expressing either human estrogen receptor [Saccharomyces cerevisiae ER + LYS 8127 (YER)] or androgen receptor [S. cerevisiae AR + 8320 (YAR)], we evaluated the hormonal activities of several chemicals by induction of ${\beta}-galactosidase$ activity. The chemicals were $17{\beta}-estradiol$ (E2), testosterone (T), ${\rho}-nonylphenol$ (NP), bisphenol A (BPA), genistein (GEN), 2-bromopropane (2-BP), dibutyl phthalate (DBP), di-(2-ethylhexyl) phthalate (DEHP), 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), and butylparaben (BP). To assess the estrogenicity of NP, the result of the in vitro recombinant yeast assay was compared with an E-screen assay using MCF-7 human breast cancer cells and an uterotrophid assay using ovariectomized mice. In the YER yeast cells, E2, NP, BPA, GEN, and BP exhibited estrogenicity in a doseresponse manner, while TCDD did not. All the chemicals tested, except T, did not show androgenicity in the YAR yeast cell. The sensitivity of the yeast (YER) assay system to the estrogenic effect of NP was similar to that of the E-screen assay. NP was also estrogenic in the uterotrophic assay. However, in terms of convenience and costs, the yeast assay was superior to the E-screen assay or uterotrophic assay. These results suggest that the recombinant yeast assay can be used as a rapid tool for detecting chemicals with hormonal activities.

  • PDF