• 제목/요약/키워드: Dibromochloromethane

검색결과 13건 처리시간 0.021초

수영장 욕조수의 소독방법에 따른 THMs 발생 특성 (The Characteristics of THMs Production by Different Disinfection Methods in Swimming Pools Water)

  • 이진;하광태;조경덕
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.171-178
    • /
    • 2006
  • The objectives of this study were to investigate the formation of trihalomethanes(THMs) and to compare the concentration level of THMs of swimming pools water by different disinfection methods such as chlorine, ozone-chlorine, and salt brine electrolysis generator (SBEG). The concentration of chloroform was the highest in the chlorine system, and the SBEG was the highest in the production of bromodichloromethane (BDCM), dibromochloromethane (DBCM) and bromoform. The average concentration of total trihalomethanes (TTHMs) in three disinfection systems were $64.5{\pm}27.4mg/l(SBEG),\;43.8{\pm}22.3mg/l(chlorine)$, and $30.6{\pm}16.1mg/l(ozone-chlorine)$, respectively. In chlorine and ozone-chlorine disinfection system, chloroform concentration was highest, followed by BDCN, then DBCM. In the SBEG, TTHMs was composed of 42% of chloroform, 28.9% of bromoform, 15.1% of BDCM and 14% of DBCM, respectively. The strongest correlation was obtained in the levels of chloroform and TTHMs in chlorine, and ozone-chlorine disinfection systems from both indoor and outdoor swimming pools ($r=0.989{\sim}0.999$, p<0.01). In the SBEG, the levels of BDCM and TTHMs showed a good correlation (r=0.913, p<0.01). In chlorine and ozone-chlorine disinfection systems at indoor swimming pools, pH, TOC and $KMnO_4$ consumption showed strong correlation with chloroform and TTHMs concentrations (p<0.01). In the SBEG, pH and TOC were also strongly correlated with chloroform (p<0.01). pH and TTHMs were correlated as well (p<0.05).

일개 실내수영장의 공기 중 염소 및 트리할로메탄의 노출평가 및 환기 효율 평가 (Assessment for Inhalation Exposure to Trihalomethanes (THMs) and Chroline and Efficiency of Ventilation for an Indoor Swimming Pool)

  • 박해동;박현희;신정아;김태호
    • 한국환경보건학회지
    • /
    • 제36권5호
    • /
    • pp.402-410
    • /
    • 2010
  • The objectives of this study were to evaluate the air quality surrounding an indoor swimming pool, to estimate the cancer risk based on the airborne exposure to trihalomethanes (THMs), and to examine the ventilation efficiency by Computational Fluid Dynamics (CFD). Chlorine and THMs were measured poolside, and in the staff room and reception area. The indoor swimming pool was modeled using the Airpak program, with ventilation drawings and actual survey data. Temperature, flow and mean age of the air were analyzed. Levels of chlorine poolside, and in the staff room, and reception area were $203\;{\mu}g/m^3$, $5\;{\mu}g/m^3$, and $10\;{\mu}g/m^3$, respectively. Chloroform was the dominant THM in all sampling sites and mean concentrations were $16.30\;{\mu}g/m^3$, $0.51\;{\mu}g/m^3$, and $0.06\;{\mu}g/m^3$ poolside, in the staff room and reception area, respectively. Bromodichloromethane and Dibromochloromethane levels were respectively estimated as $10.3\;{\mu}g/m^3$ and $1.7\;{\mu}g/m^3$ poolside, $1.3\;{\mu}g/m^3$ and $0.1\;{\mu}g/m^3$ in the staff room, and were not detected in the reception area. The cancer risks from inhalation exposure to THMs were estimated between $3.37{\times}10^{-7}$ and $1.84{\times}10^{-5}$. A short circulation phenomenon was observed from the supply air vents to the exhaust air vents located in the ceiling. A high temperature layer was formed within one meter of the ceiling, and a low temperature layer was formed under this layer due to the low velocity and high temperature of the supply air, and the improper locations of the supply air vents and exhaust air vents. The stagnation was evident at the above adult pool and the mean age of the air was 22 minutes. Disinfection by-products in the indoor swimming pool were present in higher concentrations than in the outdoor air. In order to increase the removal of pollutants, adjustment was required of the supply air volume and the supply/exhaust position.

대형건축물 저수조의 수질실태 및 개선방안에 관한 연구 (A Study on the Water Quality of Reservoir Tank in the Building Complex on Jeonnam Area)

  • 이지헌;이해훈;김환범;안길원;박귀님;김양기;배주순;문희;박철웅;오은하;박송인;서윤규
    • 환경위생공학
    • /
    • 제15권4호
    • /
    • pp.59-77
    • /
    • 2000
  • This study was carried out to investigate on several factors, which contaminative the water quality through the water pipe during feeding water, in 42 largescaled apart-ments(total 84 cases) and assayed the Volatile Organic Compounds(VOCs) and concen-tration of heavy metals that inflow and outflow in reservior water in Jeonnam area(Mokpo, Suncheon, Yeosu) from January 1999 to December 1999. The results obtained were summarized as follows ; 1. The quality of the water pipe composition in the order of frequency in the quality of water pipes were Copper(45.2%)> Zinc(38.9%)> Stainless steel(9.5%)> PVC(4.8%)> PM(2.4%) in observing 42 sites. All of the drain pipes were used the cast iron quality. 2. The result of certification curve from 12 items(17kind) of VOCs was $1.0-4.0{\mu{g}}/{\ell}$ range, a coefficient of correlation was shown 0.99 over. A MDL of each substance range was within $0.1-1.0{\mu{g}}/{\ell}$. 3. The result of the assay, 5 kinds(Viny chloride, Dichloromethane, Ethylbenzene, M,P-xylene, Styrene) of the VOCs of 14 kinds was not detected and the other items were detected slightly. The detection rate of one item and over in total VOCs samples, were 25.9% in inflow and 27.9% in outflow. And frequency of detect in inflow/outflow of THM(Chloroform, Bromodichloro-methane, Dibromochloromethane, Bromoform) were shown higher than 94.1%, 97.0% each stages. It comes to the conclusion that all of the samples were reason able for drinking water standards. 4. The coefficient of correlation were reasonable, it shown 0.999 over in $0.1-1.0{\mu{g}}/{\ell}$ of a measuring range conditions of 4kinds in organic substance(Zn, Cu, Fe, Mn). 5. The results were showed suitability in 78 cases(92.9%) and unsuitability in 6 cases (7.1%), in 84 cases of in organic substances. Compare to inflow stage, mean concentrations of heavy metal, were increased slightly in Zn, Cu, Fe except Mn than outflow stage. The result of the mean concentration in organic substance inflow and outflow in the apartment water tank using Pair-compared T-test, in 95% reliance index, were $0.179mg/{\ell}(0.151-0.307mg/{\ell})$ in Zinc, $0.136mg/{\ell}(0.113-0.230mg/{\ell})$ in Copper, $0.052mg/{\ell}(0.048-0.098mg/{\ell})$ in Fe, and there was a bit growing tendency but there was no differece in Mn. 6. The mean concentration of Copper which used Cu pipe as a water supply pipe in apartment were $0.216mg/{\ell}(0.161-0.338mg/{\ell})$ in case of the Zine pipe were $0.286mg/{\ell}(0.204-0.435mg/{\ell})$. It shows that the detection rate was more higher than the other material used in Cu or Zn as the water supply pipe. We supposed to Cu and Zn substance were gushing out water supply pipe.

  • PDF