• 제목/요약/키워드: Diastolic Velocity

검색결과 74건 처리시간 0.023초

Pulse Wave Velocity(PWV)와 혈청지질수치를 포함한 심혈관 질환 위험 요인들과의 상관관계 연구 (The Relationship between Pulse Wave Velocity (PWV) and Risk Factors of Cardiovascular Disease including Serum Lipid Values)

  • 정승환;엄은진;박우람;이범준;나병조
    • 대한한방내과학회지
    • /
    • 제30권3호
    • /
    • pp.525-533
    • /
    • 2009
  • Objectives : There are lots of reports that cardiovascular disease, including hypertension, cerebro-vascular accident, and coronary heart disease, is related to atherosclerotic changes. Increased serum levels of lipids could play a role in these changes. This study aimed to investigate the relationship between PWV and risk factors of cardiovascular disease, including serum lipid values. Methods : This study included 261 subjects ($49.32{\pm}11.79$ years, 112 male) who underwent PWV and serum lipid evaluation. We investigated the correlation between serum lipid values, blood pressure, body mass index (EMI) and PWV. Pearson's correlation and partial correlation analysis were applied to examine the relationship between PWV and risk factors of cardiovascular disease. Results : Serum triglyceride, total cholesterol, systolic blood pressure, and diastolic blood pressure were significantly correlated with PWV. Partial correlation coefficient adjusted by age yielded significant correlation between serum triglyceride, systolic blood pressure, diastolic blood pressure and PWV. Conclusion : In this study, it seems that there are significant relationships between PWV, triglyceride and blood pressure. We could suggest that PWV might have some relationships with Dam-eum and blood stasis in oriental theory.

  • PDF

Cardiac Response to Head-Out Water Immersion in Man

  • Choi, Jang-Kyu;Park, Won-Kun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제4권3호
    • /
    • pp.253-261
    • /
    • 2000
  • Head-out water immersion induces marked increase in the cardiac stroke volume. The present study was undertaken to characterize the stroke volume change by analyzing the aortic blood flow and left ventricular systolic time intervals. Ten men rested on a siting position in the air and in the water at $34.5^{circ}C$ for 30 min each. Their stroke volume, heart rate, ventricular systolic time intervals, and aortic blood flow indices were assessed by impedance cardiography. During immersion, the stroke volume increased 56%, with a slight (4%) decrease in heart rate, thus cardiac output increased ${\sim}50%.$ The slight increase in R-R interval was due to an equivalent increase in the systolic and diastolic time intervals. The ventricular ejection time was 20% increased, and this was mainly due to a decrease in pre-ejection period (28%). The mean arterial pressure increased 5 mmHg, indicating that the cardiac afterload was slightly elevated by immersion. The left ventricular end-diastolic volume index increased 24%, indicating that the cardiac preload was markedly elevated during immersion. The mean velocity and the indices of peak velocity and peak acceleration of aortic blood flow were all increased by ${\sim}30%,$ indicating that the left ventricular contractile force was enhanced by immersion. These results suggest that the increase in stroke volume during immersion is characterized by an increase in ventricular ejection time and aortic blood flow velocity, which may be primarily attributed to the increased cardiac preload and the muscle length-dependent increase in myocardial contractile force.

  • PDF

신경초음파 검사에서 Doppler소견의 판독 (Interpertation of Doppler Indicies in Neurosonologic Examinations)

  • 김제
    • Annals of Clinical Neurophysiology
    • /
    • 제1권1호
    • /
    • pp.47-54
    • /
    • 1999
  • The Doppler in neurosonologic examination could be applied to blood flow to determine its movement, the direction of its movement, and how fast it is. Indicies of the Doppler study denoted velocity, direction, and amount of RBC in the examined vessel. Systolic. diastolic, and mean blood flow velocities represent velocity of RBCs in a sample volume. Blood flow direction to the probe means direction of RBC to the probe. Size of amplitude displays toe amount of the RBCs passing the sample volume. Spectral broadening means presence of turbelence. The RBC movements and hemodynamics at the examined vessels can be estimated by analysis of Doppler indicies The formation and meaning of each of neurosonologic Doppler study is described in the present review.

  • PDF

비대성심근증 환자의 이완기능평가: 승모판과 폐정맥 유속을 측정한 위상차 MRI의 이용 (Diastolic Function in Patients with Hypertrophic Cardiomyopathy: Evaluation Using the Phase-contrast MRI Measurement of Mitral Valve and Pulmonary Vein Flow Velocities)

  • 김은영;최연현;김성목;이상철;장성아;오재건
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권4호
    • /
    • pp.314-322
    • /
    • 2014
  • 배경: 심장의 이완기능 이상은 비대성심근증 환자에서 흔히 발견되는 문제이다. 본 연구는 비대성심근증 환자의 심장 이완기능을 평가하는 데 있어, 승모판과 폐정맥의 유속을 이용한 MRI의 역할을 알아보고자 하였다. 방법과 결과: 승모판과 폐정맥의 유속을 이용한 위상차 MRI와 심초음파검사가 59명 (남:여 = 44:15, 평균 연령 = 51세)의 비대성심근증 환자에서 시행되었다. 49명의 환자가 심초음파검사에서 다양한 정도의 심장 이완기능 이상을 보였다; grade 1 (20명), grade 2 (27명), and grade 3 (2명). MRI로 계산한 승모판 유속인자들 (E, A, E/A ratios)은 심초음파검사로 구한 동일 인자들과 양의 상관관계를 보였다 (Pearson's r values = 0.47, 0.60, 0.75 for E, A, E/A, respectively, all P < 0.001). MRI로 폐정맥 유속정보를 이용하는 경우, pseudo-normalized pattern (8명)이 정상 충만 양상(filling pattern) (17명)과 구분될 수 있었고, 이들을 이용하여 이완기능 정도를 평가를 하는 경우, 심장 MRI가 심초음파검사와 중등도의 일치도를 보였다 (kappa value = 0.45, P < 0.001). 결론: 비대성심근증 환자에서 위상차 MRI를 이용한 심장 이완기능 평가는 임상적으로 적용 가능한 방법이며, 폐정맥 유속 분석을 추가하는 경우, 정상과 pseudo-normal을 구분하는데 유용하다.

Transcranial Doppler를 이용(利用)한 급성기뇌경색(急性期腦硬塞)이 추골기저동맥계(椎骨基底動脈係) 혈관(血管)의 혈류속도(血流速度)에 미치는 영향(影響) (The Transcranial Doppler(TCD) Assesment of Vertebrobasal Vascular Blood Flow in Cerebral Infarction)

  • 안탁원;김윤식
    • 대한한방내과학회지
    • /
    • 제21권5호
    • /
    • pp.805-811
    • /
    • 2000
  • Objectives : To determine the effects on blood flow of vertebrobasal vascular system in cerebral infarction, Methods : We altered 33 normal patients and 12 patients who were diagnosed cerebral infarction on Rt. middle cerebral artery(MCA) region and 8 patients who were diagnosed cerebral infarction on Lt, MCA region, and measured the mean velocity, systolic to diastolic rate(SD rate), asymmetrical index(A/I) by TCD. Results : The mean velocity of posterior cerebral artery(PCA), vertebral artery was increased in same direction as infarcted site and the mean velocity of basal artery was more increased than control, and the SD rate of PCA, vertebral artery, basal artery was larger than control. The A/l of PCA, vertebral artery was revealed that mean velocity of vertebrobasal vascular system is increase the same direction as infarcted area. Conclusion : TCD examination within 7 days(acute stage) after stroke can help to predict the infarcted direction.

  • PDF

경두개 도플러 초음파의 측정지표와 성/연령의 상관성 (Correlation of Gender/Age and Measurement Indices of Transcranial Doppler Ultrasonography)

  • 진복희
    • 대한임상검사과학회지
    • /
    • 제42권3호
    • /
    • pp.155-160
    • /
    • 2010
  • Transcranial Doppler ultrasonography (TCD) allows measurement of blood flow velocity to be made from the basal intracerebral vessels. Blood flow velocity in TCD is highly affected not only by blood vessel diameter, blood flow volume, blood viscosity, but also age and sex. Therefore, the study is focused on the correlation between TCD measurement index and sex/age. Subjects were 214 (male 147, famale 67) who had TCD for headache and stroke evaluations at Dongguk University Ilsan Hospital neurology department from December 2009 to April 2010. Sex did not show significant differences with mean flow velocity (MFV), peak systolic flow velocity (PSFV), end diastolic flow velocity (EDFV), pulsatility index (PI) and resistance index (RI) in middle cerebral artery (MCA). Although age also did not show significant differences with MFV and PSFV, EDFV has statistically decreased with age, and PI and RI has statistically increased with age. In addition, age showed significant correlation with MFV, EDFV, PI and RI, but not with PSFV. Therefore, TCD is definitely correlated with age and sex, so that those influencial factors must be considered when being tested.

  • PDF

혈관미주 신경성 실신 소아에서 기립경사 검사 동안에 뇌혈류 변화 (Change of Cerebral Blood Flow during Tilt Tests in Children with Vasovagal Syncope)

  • 김수정;염혜원;홍영미;유정현;이숙희;김종희
    • Clinical and Experimental Pediatrics
    • /
    • 제46권10호
    • /
    • pp.983-988
    • /
    • 2003
  • 목 적 : 실신은 소아에서 가장 흔한 증상이지만 기전은 잘 알려져 있지 않다. 증가된 미주신경의 활동과 감소된 교감신경의 자극이 저혈압, 서맥을 일으키고 마침내는 의식 소실을 초래한다. 이 연구의 목적은 혈관미주 신경성 실신으로 진단된 소아에서 기립경사 검사를 하는 동안 뇌 도플러 초음파를 실시하여 실신 전후의 뇌혈류 속도와 혈압, 심박동수 변화를 측정하고자 하였다. 방 법 : 실신의 과거력을 갖고 있는 64명의 소아를 대상으로 혈압을 10분간 안정 후와 15분 동안 기립 후에 측정하였고, 기립 경사 검사는 $80^{\circ}$에서 45분간 시행하였다. $80^{\circ}$ 각도의 경사 테이블에서 소아를 5분 간격으로 45분 동안 혈압, 심박동수, 산소 포화도를 측정하였다. 기립경사 검사를 하는 동안 실신이나 실신 전 증상이 나타난 소아에서는 검사를 중단하였다. 12-유도 심전도, 뇌파 검사, 심장 초음파를 시행하였다. 기립경사 검사에서 양성으로 나온 10명의 소아에서 Acouson 128XP/10 model 초음파 기기를 이용하여 중 대뇌동맥 혈류 속도, pulsatility 지수, time velocity integral, 혈압, 심박동수, 산소포화도 등을 측정하였다. 결 과 : 기립경사 검사에서 31.3%(20/64)의 양성률을 보였다. 검사 동안에 혈압과 맥박은 감소되지 않았고 뇌혈류 속도와 integral은 유의하게 감소되었다. 결 론: 뇌혈류 속도는 혈압이나 심박동수가 감소하기 전에 미리 감소하므로 실신 전 증상을 미리 예측할 수 있다. 뇌혈류의 자율 조절의 장애가 혈관미주 신경성 실신의 병인론에 중요한 역할을 하리라 생각된다.

The Effect of Sun Ginseng on Hemodynamics and Body Temperature in Healthy Young Men

  • Lee, Jeeh-Wan;Cho, Jung-Ah;Ki, Chan-Young;Park, Jeong-Hill;Park, Man-Ki
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.317.2-318
    • /
    • 2003
  • The current study was performed to observe the effect of Sun Ginseng (SG) on hemodynamics such as blood flow rate (BF), blood flow velocity (BV), heart rate (HR), systolic blood pressure (SBP) and diastolic blood pressure (DBP), and body temperature (BT) in healthy young men. This is a randomized, single-blind study observed during 6 hrs after orally single administration of SG. (omitted)

  • PDF

우황청심원이 정상인의 뇌혈류 및 혈압에 미치는 영향 (Effects of Uwhangchungsimwon(牛黃淸心元) on Cerebral Blood Flow and Systemic Blood Pressure in Humans)

  • 김영석
    • 대한한방내과학회지
    • /
    • 제20권1호
    • /
    • pp.222-231
    • /
    • 1999
  • Uwhangchungsimwon(UC) has been used in the treatment of a wide variety of conditions including stroke, hypertension, arteriosclerosis, autonomic imbalance, mental instablity, etc in Korean traditional hospitals, In particular it is often initialy chosen for emergency care of acute stroke. The aim of this study was to evaluate the effect of UC on cerebral hemodynamics. Using transcranial Doppler ultrasound, we studied changes of mean flow velocity and pulsatility index(PI) of middle cerebral arteries (MCAs) from 11 health young volunteers who were administrated with 1 pill UC and 11 health controls who were not. We obtained hypercapnia with breath-holding and evaluated cerebrovascular reactivity with breath-holding index(BHI). Systolic blood pressure, diastolic blood pressure, and heart rate were measured using ambulatory blood pressure monitoring(ABPM). In UC administration group, the evaluation was performed during basal condition. and repeated at 20, 40, and 60 min after administration. In controls, the evaluation was performed at corresponding time intervals. Mean flow velocity in middle cerebral artery, systolic blood pressure, diastolic blood pressure, and heart rate did not change during the observation period and were not different between these two groups. However, administration of UC was associated with decreases in PI by $3.6{\sim}12.4%$ in BHI by $17.9{\sim}24.8%$ compared with pre-administration period. Decreases in PI and BHI with UC were significantly different compared with control group (p<0.05). These results indicate that UC decreases PI and BHI in cerebral artery, which is due to a dilation of cerebral resistance vessels.

  • PDF

두 개의 광전용적맥파 기반의 수축기 혈압과 이완기 혈압 추정 융합 알고리즘 모델 분석 (Analysis of the Convergence Algorithm Model for Estimating Systolic and Diastolic Blood Pressure Based on Two Photoplethysmography)

  • 김선칠;조성현
    • 한국융합학회논문지
    • /
    • 제10권8호
    • /
    • pp.53-58
    • /
    • 2019
  • 최근 만성질환자 건강관리의 목적으로 혈압측정에 대한 접근성을 높이는 제품 연구가 지속적으로 이루어지고 있다. 기존 연구에서는 심전도(ECG)와 광전용전맥파(PPG)를 분석하여 수축기혈압과 이완기 혈압을 산출하는 방식을 사용하고 있다. 주 과제는 정확도와 재현성을 위한 분석 알고리즘 개발이다. 본 연구에서는 초소형 혈압측정장치를 개발하는 단계에서 장치의 크기를 줄이고 측정방법도 간단히 하는 동시에 알고리즘도 두 개의 PPG만을 이용하여 최고혈압(SBP)을 추출하고 이에 따른 최저혈압(DBP)을 구하고자 하였다. 이를 위해 두 개의 PPG에서 얻은 측정값과 SBP, DBP 관계를 통계적으로 추적하여 상호관계를 분석하였다. PPG의 차이 값인 DF_P는 SBP와 반비례 관계가 있으며, DBP와는 비례적 관계가 성립되어 알고리즘에 의해 혈압값을 유추할 수 있으며, SBP를 통해 DBP를 추적할 수 있다.