• 제목/요약/키워드: Diaphragms

검색결과 161건 처리시간 0.032초

동해석을 이용한 연료펌프의 캠 형상 설계 (Cam Profile Design of a Fuel Pump Using Dynamic Analysis)

  • 이봉호;이부윤;김원진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.58-64
    • /
    • 2006
  • This work focuses on reducing the noise and vibration levels of an LPi fuel pump, which are generated from the dynamic motions of pump elements and non-uniform flow of fuel. The noise and vibration levels increase as the revolution speed of the cam goes up. The fuel pump consists of five cavity cells, plungers and diaphragms, which are driven by the cam. The optimal design of the cam profile is performed to decrease the accelerations of moving Parts and to obtain a smooth hydraulic force through a dynamic analysis of a cam-plunger mechanism. The cam-Plunger with a cavity is modeled as a 2 degrees of freedom system having non-linear contacts, the cam profile being represented in terms of Fourier series in order to determine the optimal shape of the cam. From the optimized cam Profile, the acceleration of the diaphragm is reduced in $78\%$, the hydraulic force becoming smoother in case that the hydraulic force is rapidly dropped.

단면변형의 효과를 포함한 강상자형 거더의 엄밀한 해석 (An Exact Analysis of Steel Box Girders with the Effects of Distortional Deformation of Sections)

  • 진만식;이병주;김문영
    • 한국전산구조공학회논문집
    • /
    • 제17권1호
    • /
    • pp.11-20
    • /
    • 2004
  • 본 연구에서는 직선 강상자형 거더의 단면변형에 의한 변형 및 응력계산을 위한 Matlab 해석프로그램을 개발하고자 한다. 이를 위하여 단면변형이론을 요약하고 빔유사이론을 제시한다. 이후 탄성지반위의 보-기둥부재의 지배방정식을 제시하고, 일반화된 고유치해석을 통하여 집중 및 분포하중을 받는 보요소의 엄밀한 강성행렬을 계산한다. 본 연구의 효율성과 정확성을 입증하기 위하여 격벽을 갖는 상자형 거더의 뒤틀림응력을 계산하고 유한요소해와 비교한다.

대동맥 축착증 1례 보고 (Discrete coarctation of the aorta: report of a case)

  • 허용;안욱수;류병하;김병열;장운하;이정호;유회성
    • Journal of Chest Surgery
    • /
    • 제15권3호
    • /
    • pp.361-365
    • /
    • 1982
  • Coarctation of the aorta is a congenital constriction of the aorta of varying degree usually located slightly distal to the origin of the left subclavian artery. This congenital malformation is found at 5-9% of the congenital heart disease in Europe & North America, but in our country, it is reported as one of rare malformations. We present a case of coarctation of the aorta, which had double diaphragms as discrete form. This is 9 year-old boy, who has suffered from hypertensive symptoms since 6 years before. Coarctation of the aorta was confirmed by aortography, and there was no combined anomalies, and it was postductal type, and coarctations were consisted of two diaphragmatic webs at the both ends with a central aneurysmized. After resection of the coarctated segment completely, Woven Dacron graft was inserted with 18mm in diameter & 2.5cm in length successfully.

  • PDF

Force transfer mechanism in positive moment continuity details for prestressed concrete girder bridges

  • Hossain, Tanvir;Okeil, Ayman M.
    • Computers and Concrete
    • /
    • 제14권2호
    • /
    • pp.109-125
    • /
    • 2014
  • The force transfer mechanism in positive moment continuity details for prestressed concrete girder bridges is investigated in this paper using a three-dimensional detailed finite element model. Positive moment reinforcement in the form of hairpin bars as recommended by the National Cooperative Highway Research Program Report No 519 is incorporated in the model. The cold construction joint that develops at the interface between girder ends and continuity diaphragms is also simulated via contact elements. The model is then subjected to the positive moment and corresponding shear forces that would develop over the service life of the bridge. The stress distribution in the continuity diaphragm and the axial force distribution in the hairpin bars are presented. It was found that due to the asymmetric configuration of the hairpin bars, asymmetric stress distribution develops at the continuity diaphragm, which can be exacerbated by other asymmetric factors such as skewed bridge configurations. It was also observed that when the joint is subjected to a positive moment, the tensile force is transferred from the girder end to the continuity diaphragm only through the hairpin bars due to the lack of contact between the both members at the construction joint. As a result, the stress distribution at girder ends was found to be concentrated around the hairpin bars influence area, rather than be resisted by the entire girder composite section. Finally, the results are used to develop an approach for estimating the cracking moment capacity at girder ends based on a proposed effective moment of inertia.

Development of a Peristaltic Micropump with Lightweight Piezo-Composite Actuator Membrane Valves

  • Pham, My;Goo, Nam-Seo
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제12권1호
    • /
    • pp.69-77
    • /
    • 2011
  • A peristaltic micropump with lightweight piezo-composite actuator (LIPCA) membrane valves is presented. The micropump contained three cylinder chambers that were connected by microchannels and two active membrane valves. A circular miniature LIPCA was developed and manufactured to be used as actuating diaphragms. The LIPCA diaphragm acted as an active membrane valve that alternate between open and closed positions at the inlet and outlet in order to produce high pumping pressure. In this LIPCA, a lead zirconium titanate ceramic with a thickness of 0.1 mm was used as an active layer. The results confirmed that the actuator produced a large out-of-plane deflection. During the design process, a coupled field analysis was conducted in order to predict the actuating behavior of the LIPCA diaphragm; the behavior of the actuator was investigated from both a theoretical and experimental perspective. The active membrane valve concept was introduced as a means for increasing pumping pressure, and microelectromechanical system techniques were used to fabricate the peristaltic micropump. The pumping performance was analyzed experimentally in terms of the flow rate, pumping pressure and power consumption.

Ginseng total saponin modulates podocyte p130Cas in diabetic condition

  • Ha, Tae-Sun;Lee, Jin-Seok;Choi, Ji-Young;Park, Hye-Young
    • Journal of Ginseng Research
    • /
    • 제37권1호
    • /
    • pp.94-99
    • /
    • 2013
  • Proteinuric conditions demonstrate structural and compositional changes of the foot processes and slit diaphragms between podocytes. p130Cas in podocytes serves as an adapter protein anchoring glomerular basement membrane to actin filaments of podocyte cytoskeleton. To investigate the effect of ginseng total saponin (GTS) on the pathologic changes of podocyte p130Cas induced by diabetic conditions, we cultured mouse podocytes under: 1) normal glucose (5 mM, control); 2) high glucose (HG, 30 mM); 3) advanced glycosylation endproducts (AGE)-added; or 4) HG plus AGE-added conditions and treated with GTS. In confocal imaging, p130Cas colocalized with zonula occludens-1 and synaptopodin connecting to F-actin. However, diabetic conditions relocalized p130Cas molecules at perinuclear cytoplasmic area and reduced the intensity of p130Cas. In Western blotting, diabetic conditions, especially HG plus AGE-added condition, decreased cellular p130Cas protein levels at 24 and 48 h. GTS improved such quantitative and qualitative changes. These findings imply that HG and AGE have an influence on the redistribution and amount of p130Cas of podocytes, which can be reversed by GTS.

반도체 공정용 차압식 질량 유량 제어 장치의 개발 및 성능 평가 (Development and Evaluation of Differential Pressure Type Mass Flow Controller for Semiconductor Fabrication Processing)

  • 안진홍;강기태;안강호
    • 반도체디스플레이기술학회지
    • /
    • 제7권3호
    • /
    • pp.29-34
    • /
    • 2008
  • This paper describes the fabrication and characterization of a differential pressure type integrated mass-flow controller made of stainless steel for reactive and corrosive gases. The fabricated mass-flow controller is composed of a normally closed valve and differential pressure sensor. A stacked solenoid actuator mounted on a base-block is utilized for precise and rapid control of gas flow. The differential pressure flow sensor consisting of four diaphragms can detect a flow rate by deflection of diaphragm. By a feedback control from the flow sensor to the valve actuator, it is possible to keep the flow rate constant. This device shows a fast response less than 0.3 sec. Also, this device shows accuracy less than 0.1% of full scale. It is confirmed that this device is not attacked by toxic gas, so the integrated mass-flow controller can be applied to advanced semiconductor processes which need fine mass-flow control corrosive gases with fast response.

  • PDF

고온용 마이크로 세라믹 박막형 압력센서의 제작과 그 특성 (Fabrication of Micro Ceramic Thin-Film Type Pressure Sensors for High-Temperature Applications and Its Characteristics)

  • 김재민;이종춘;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.888-891
    • /
    • 2003
  • This paper describes on the fabrication and characteristics of micro ceramic thin-film type pressure sensors based on Ta-N strain-gauges for high-temperature applications. The Ta-N thin-film strain-gauges are deposited onto thermally oxidized Si diaphragms by RF sputtering in an argon-nitrogen atmosphere($N_2$ gas ratio: 8 %, annealing condition: $900^{\circ}C$, 1 hr.), Patterned on a wheatstone bridge configuration, and use as pressure sensing elements with a high stability and a high gauge factor. The sensitivity is $1.097{\sim}1.21mV/V.kgf/cm^2$ in the temperature range of $25{\sim}200^{\circ}C$ and the maximum non-linearity is 0.43 %FS. The fabricated pressure sensor presents a lower TCR, non-linearity than existing Si piezoresistive pressure sensors. The fabricated micro ceramic thin-film type pressure sensor is expected to be usefully applied as pressure and load sensors that is operable under high-temperature environments.

  • PDF

3차원 LTCC 기판을 이용한 PZT 압력센서의 주파수 응답 특성 (Frequency response characteristics of PZT pressure sensor using three dimensional LTCC substrates)

  • 허원영;이경천;황현석;이태용;송준태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.204-204
    • /
    • 2010
  • A development of device with reduced size and improved sensitivity is highly impotant Pb(Zr,Ti)$O_3$ thin films are widely used both to make actuator and sensor due to their high sensitivity and low cost. In this study, the feasibility of a piezoelectric presssure sensors based on hybrid low-temperaute co-fired ceramic (LTCC) technology were presented. The LTCC diaphragms with thickness of $400\;{\mu}m$ were fabricated by laminating 4 green tapes which consist of alumina and glass particle in an organic binder. PZT thin films were successfully prepared on between top and bottom Au electrode with LTCC substrates using RF magnetron sputtering. In addition, The frequency response characteristics of the sensor under varing pressure has been analysed. by Network Analyser (HP-8722D). A frequency shift range has been obseved from 1.7GHz to 1.8GHz with a good linearity for applied pressure from 0 psi up to 25 psi.

  • PDF

TMAH/AP 용액의 실리콘 이방성 식각특성 및 다이아프램 제작에 대한 연구 (A Study on Anisotropic Etching Characteristics of Silicon in TMAH/AP Solutions and Fabrication of a Diaphragm)

  • 윤의중;김좌연;이태범;이석태
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.1033-1036
    • /
    • 2003
  • In this paper, Si anisotropic etching characteristics of tetramethylammonium hydroxide (TMAH)/ ammonium persulfate (AP) solutions were investigated to realize the optimum structure of a diaphragm for the piezoresistive pressure sensor application. Due to its low toxicity and its high compatibility with the CMOS processing, TMAH was used as Si anisotropic etchants. The variations of Si etch rate on the etching temperature, TMAH concentration, and etching time were obtained. With increasing the etching temperature and decreasing TMAH concentrations, the Si etch rate is increased while a significant non-uniformity exists on the etched surface because of formation of hillocks on the <100> surface. With the addition of AP to TMAH solution, the Si etch rate is increased and an improvement in flatness on the etching front is observed. The Si etch rate is also maximized with increasing the number of addition of AP to TMAH solution per one hour. The Si square diaphragms of 20${\mu}{\textrm}{m}$ thickness and 100~400${\mu}{\textrm}{m}$ one-side length were fabricated successfully by applying optimum Si etching conditions of TMAH/AP solutions.

  • PDF