• 제목/요약/키워드: Diaphragm Valve

검색결과 62건 처리시간 0.027초

공기구동밸브의 동특성 모델링 및 시험 (Dynamic Modeling and Test of the Air-Operated Valve)

  • 조택동;이호영;양상민;양성빈;권봉수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1808-1811
    • /
    • 2005
  • The prediction of AOV(air-operated valve) performance is normally evaluated by the allowable opening thrust margin for the opening and closing stroke. However, it is not easy to carry out the dynamic test measurement for all the valves in the nuclear power plant due to the safety and operating conditions. The analysis of the available and required thrust for the valve is simulated as an alternate method to turn around this obstacle. The required air pressures to the stem displacement are discussed for differential valve pressure obtained by experiment. The result of the simulation is compared with that of the experiment. SIMULINK in MATLAB was used for the simulation and the results show good agreement with the actual test carried out with Fisher globe valve.

  • PDF

Development of a Peristaltic Micropump with Lightweight Piezo-Composite Actuator Membrane Valves

  • Pham, My;Goo, Nam-Seo
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제12권1호
    • /
    • pp.69-77
    • /
    • 2011
  • A peristaltic micropump with lightweight piezo-composite actuator (LIPCA) membrane valves is presented. The micropump contained three cylinder chambers that were connected by microchannels and two active membrane valves. A circular miniature LIPCA was developed and manufactured to be used as actuating diaphragms. The LIPCA diaphragm acted as an active membrane valve that alternate between open and closed positions at the inlet and outlet in order to produce high pumping pressure. In this LIPCA, a lead zirconium titanate ceramic with a thickness of 0.1 mm was used as an active layer. The results confirmed that the actuator produced a large out-of-plane deflection. During the design process, a coupled field analysis was conducted in order to predict the actuating behavior of the LIPCA diaphragm; the behavior of the actuator was investigated from both a theoretical and experimental perspective. The active membrane valve concept was introduced as a means for increasing pumping pressure, and microelectromechanical system techniques were used to fabricate the peristaltic micropump. The pumping performance was analyzed experimentally in terms of the flow rate, pumping pressure and power consumption.

시트 체크밸브를 갖는 압전펌프 설계 및 펌프 실험장치 제작 (Design and Test Rig Construction for Piezoelectric Pump having Sheet Type Check Valve)

  • 함영복;유진산;윤소남;최성대
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1442-1445
    • /
    • 2003
  • In precision machinery industry, it's required with small size and low noise design to using in constant liquid delivery equipment. To accomplish it's purpose, we designed the check valve with rubber sheet of circle shapes as a possible assembly in pump body. The test equipment for piezoelectric pump was able to test pressure-flow property and output property of piezoelectric pump by variation(magnitude of voltage and frequency) of input power.

  • PDF

모터와 비례제어 밸브의 특성실험을 통한 기계적 호흡 모사장치연구 (The study of mechanical human respiratory simulator via characteristic test of motor and proportional valve)

  • 이문규;지석환;이태수;오승권
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.492-495
    • /
    • 2008
  • As the obesity patients increase recently, breath disease such an OSA(obstructive sleep apnea) is also increasing. When the breath disease occurs, the risk comes to be high. Dependence degree the PAP(positive airway pressure) is also coming to be high. The mechanical simulator is composed cylinder, valve, ball screw and the motor that they correspond to the lung and airway, the diaphragm of the human. In order to confirm the characteristic of the motor and the valve, it accomplished an test. The simulator traces breath pattern against the normal breath and the OSA.

  • PDF

화차 제동장치의 공기압 특성에 관한 실험적 연구 (Experimental Study on the Pneumatic Characteristics of Brake System for Freight Car)

  • 남성원;문경호;이동형;최경진;권석진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 춘계학술대회 논문집
    • /
    • pp.110-115
    • /
    • 1999
  • Experimental study is conducted to clarify the pneumatic characteristics of brake system for freight car. KNR(Korean National Railroad)'s freight cars have the laden-tare type control valve of brake system. But, laden-tare type control valve has some shortcomings to match the high speed freight car. Newly developed diaphragm type control valve is introduced to adopt freight car for speed-up. The test using the formated train set consisted of 21 cars is conducted to estimate the pneumatic braking efficiency of the mixed train set. From the results of experiment, the pressure characteristics of each brake cylinder show similar patterns qualitatively. But, in the case of release and brake application, quantitative pressure values of brake cylinder are different.

  • PDF

유한요소법을 이용한 버클링 마이크로 밸브의 유동특성 해석 및 최적 설계 (Analysis of Flow Characteristics and Optimum Design of a Buckling Microvalve Using the Finite Element Method)

  • 김재민;이종춘;정귀상;윤석진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.383-386
    • /
    • 2002
  • This paper reports on the fluid flow simulation results of an active microvalve. The mechanical and fluidic analysis are done by finite element method. The designed structure is normally closed microvalve using buckling effect, which is consist of three separate structures; a valve seat die, an actuator die and a small piezoelectric actuator. It is confirmed that the complete laminar flow and the lowest flow leakage are strongly depend on the valve seat geometry. In addition, turbulent flow was occurs in valve outlet according to increase seat dimension, height and inlet pressure. From this, we was deducts the optimum geometry of the valve seat and diaphragm deflection that have an great influence fluid flow in microvalve. Thus, it is expected that our simulation results would be apply for constructing integrated chemical analyzing system or drug delivery system.

  • PDF

알루미늄 플랩 밸브와 상변화 구동 마이크로 펌프의 제작 (The fabrication of a micro pump with a flap valve and a phase change actuator)

  • 이상우;심우영;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1023-1025
    • /
    • 1998
  • This paper presents the fabrication of a micro pump consisting of a pair of Al f1ap wave and a phase change actuator. The phase change actuator is composed of a heater, a silicone rubber diaphragm and a working liquid chamber. The diaphragm is actuated by the evaporation and the condensation of the working liquid. The actuator pumps fluid through the valves. The micro pump is fabricated by the anisotropic etch, the boron deposition and the metal evaporation. The forward and the backward flow characteristics of the f1ap valves were obtained. Also, the flow rate of the micro pump has been measured. When the square wave input of 12 V, 60% duty ratio and 0.2 Hz is applied, the average flow rate is $0.15{\mu}{\ell}/sec$ for zero pressure difference.

  • PDF

가스밸브의 강도안전성에 관한 연구 (A Study on the Strength Safety of a Gas Valve)

  • 김청균
    • 한국가스학회지
    • /
    • 제22권1호
    • /
    • pp.60-63
    • /
    • 2018
  • 본 연구에서는 LPG 용기용 가스밸브의 강도안전성에 대한 FEM 해석결과를 제시하고 있다. FEM 해석결과에 의하면, 가스밸브가 완전히 열린 상태에서 3.5 MPa의 공급압력을 적용하였을 때, 안전밸브와 나사의 상단부사이의 경계 지역에서 발생한 von Mises 최고응력은 99.2 MPa로 나타났다. 99.2 MPa라는 von Mises 최고응력은 황동소재의 항복강도에 비해 낮은 값으로 충분히 안전한 결과이다. 이 경우에, 압력조정기의 상측 오른쪽에서는 최대 변위량 0.002mm가 발생하였다. 최대로 변형된 이 지역은 가스밸브에 설치된 오링이나 다이어프램과 같은 밀봉 부분이 아니므로 의미를 부여할 필요는 없다. 기존의 개폐식 밸브와 압력 조정기를 일체형으로 형성하여 제시한 하이브리드형의 가스밸브 모델은 LPG 용기용으로 가스누출이 없는 메커니즘과 최소로 단순화시킨 크기의 가스모델로 추천된다.

공기구동기 성능평가 시스템 개발 (The Development of Performance Evaluation System for Air-Operated Actuaotr)

  • 조택동;양성빈;이호영;양상민;권봉수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1770-1773
    • /
    • 2005
  • The performance evaluation of AOV(air-operated valve) requires the processes to confirm the actuator system capability. It is necessary to evaluate the thrust of the air actuator for the margin evaluation. In this paper, to evaluate and analysis the air actuator, the performance test system and operating program are developed. This system is composed of several sensors such as pressure sensor, LVDT, and LoadCell which are used to get the data for evaluation. The LabVIEW was used for developing the operating program. The test system and operating program are proved through the actual test of the diaphragm actuator.

  • PDF

미성숙견에서 선천성 Peritoneopericardial diaphragmatic hernia 발생례 (Peritoneopericardial diaphragmatic hernia in a immature dog)

  • 연성찬
    • 대한수의학회지
    • /
    • 제39권1호
    • /
    • pp.226-229
    • /
    • 1999
  • A 5-month-old, 5kg, intact male mixed dog was admitted to the Veterinary Medical Teaching Hospital of the College of Veterinary Medicine Cornell University because of severe systolic murmur. On physical examination, the dog appeared to be thin and slightly small for his age. Radiographic studies with barium sulfate clearly showed the presence of loops of intestines in the pericardium. Based on these findings peritoneopericardial diaphragmatic hernia was diagnosed. Many abnormalities were found in dog's heart : ventricular septal defect, pulmonic stenosis with moderate pulmonic valve insufficiency, and mild mitral and tricuspid valve insufficiency. Puppy's longterm prognosis was fair. His intestines were removed from his pericardium and the defect in his diaphragm was closed. The surgery went smoothly and puppy recovered very nicely from anesthesia.

  • PDF