• 제목/요약/키워드: Diamond

검색결과 2,376건 처리시간 0.038초

상이질 접착제의 적용방법에 따른 전단결합강도와 접착양상에 관한 연구 (INFLUENCE OF APPLICATION METHODS OF A DENTIN ADHESIVE ON SHEAR BOND STRENGTH AND ADHESIVE PATTERN)

  • 박성택;문주훈;조영곤;온영석
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.381-391
    • /
    • 1999
  • A new 5th generation adhesive system(ONE-STEP) has been supplied which operators can apply to conditioned tooth surfaces by one simplified step. The purpose of this study was to determine whether different methods of adhesive application and various air drying duration after applying adhesive affect the shear bond strength of composite resin to dentin, and to evaluate the adhesive pattern of composite resin and dentin under SEM. Seventy-seven extracted human molar teeth were cleaned and mounted in palstic test tubes. The occlusal dentin surfaces were exposed with Diamond Wheel Saw and smoothed with Lapping and Polishing Machine (South Bay Technology Co., U.S.A.). Teeth were randomly divided into 7 groups (n=11), In experimental A group, adhesive was applied to dentin with agitation for 20 sec. In experimental N-A group, adhesive were continuously applied to dentin for 20 sec. Also control and experimental 1, 2, 3, 4 groups were dried for 10, 0, 5, 20, 30 seconds after applying adhesive, respectively, Adhesives were light cured for 10 sec. A gelatin capsule 5mm in diameter was filled with Aelitefil$^{TM}$ composite resin, placed on the treated dentin surface and light cured for 40 see, from three sides, All specimens were stored in distilled water at room temperature for 24 hours. The shear bond strengths were measured using a universal testing machine(AGS-1000 4D, Japan) at a crosshead speed of 5mm/min. An one-way ANOVA and LSD test were used for statistical analysis of the data. For SEM evaluation, seven specimens were made and sectioned. Representive postfracture and seven specimens were mounted on brass stubs, sputter-coated with gold and observed under SEM. The results were as follows : 1. The shear bond strength of experimental A group which adhesive were applied to dentin with agitation was higher than that of experimental N-A group (continuous application), and there was significant difference between two groups (p<0.01). 2. The interface between composite and dentin according to different application methods showed close adaptation in experimental A group and showed tinny gap in experimental N-A group. 3. The shear bond strength accoding to various air drying duration was the lowest value(7.57${\pm}$2.60 MPa) in experimental 1 group, so there was significant difference between experimental 1 group and other four groups (p<0.05). But there was no significant difference of shear bond strength between four groups (p>0.05). 4. The interface between composite and dentin according to various air drying duration showed close adaptation in control group and tinny gap in experimental 3 and 4 groups. But experimental 1 and 2 groups showed $30{\mu}$ and 6 - $10{\mu}m$ thick gaps, respectively.

  • PDF

레진시멘트의 중합방법이 포스트의 결합강도와 접착계면에 미치는 영향 (EFFECT OF CURING METHODS OF RESIN CEMENTS ON BOND STRENGTH AND ADHESIVE INTERFACE OF POST)

  • 김문홍;김혜정;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제34권2호
    • /
    • pp.103-112
    • /
    • 2009
  • 본 연구에서는 2종의 이원중합 레진시멘트 (RelyX ARC와 Variolink II)를 이용하여 접착제와 레진시멘트의 중합방법 (자가중합과 광중합)이 섬유포스트와 근관 상아질의 결합강도와 접착계면에 미치는 영향을 상호 비교하기 위하여 시행하였다. 단근관을 갖는 발거된 32개의 하악 소구치에 근관을 충전한 후, FRC Postec system의 Reamer로 9 mm 깊이의 포스트 공간을 형성하였다. 레진시멘트의 종류와 중합방법에 따라 4개의 군 (R-SC군, R-LC군, V-SC군, V-LC군)으로 분류하였다. 포스트 공간에 각 군의 접착제를 도포한 후 레진시멘트를 주입하고, No. 3 FRC Postec 포스트를 위치시켜 자가중합 또는 광중합시켰다. 각 군의 치근을 실온의 증류수에 24시간동안 보관한 다음, 저속의 diamond wheel saw를 이용하여 치관부에서 치근단부를 향해 1.5 mm두께로 연속적으로 횡절단하여 1개의 치근에서 3개의 절편을 얻었다. 각 군의 절편 (31개)은 만능시험기에서 push-out 검사를 시행하였고, 각 군의 강도 값은 반복측정 two-way ANOVA와 one-way ANOVA를 이용하여 비교 분석하였다. 각 군의 절편 (3개)은 주사전자현미경하에서 섬유포스트, 레진시멘트 및 치근 상아질 간의 계면을 관찰, 비교하였다. 본 연구의 결과 전 부식 레진시멘트를 이용하여 섬유포스트를 포스트 공간에 합착할 경우, 접착제와 레진시멘트의 중합방법은 근관 상아질의 결합강도에 영향을 주었으며, 광중합보다 자가중합 방법 이 우수한 결합강도와 계면을 나타내었다.

수동과 엔진구동형 기구를 이용한 난원형 근관의 형성에 관한 주사전자현미경적 관찰 (A SEM OBSERVATION ON THE EFFICIENCY PREPARATION OF OVAL CANALS USING HAND AND ENGINE-DRIVEN INSTRUMENTS)

  • 송욱;허복;이희주
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.141-146
    • /
    • 2004
  • The purpose of this study was to evaluate the efficiency of the preparation of oval canals using hand and engine-driven instruments with SEM observation. Thirty single-rooted teeth with oval canal were used in this study. The teeth were divided into 3 groups. In group A the teeth were instrumented up to a size 35 K-file using RC-prep and irrigated with 5% NaOCl between each file size. In group B. the teeth were instrumented with Profile according to the manufacture's instructions using RC-Prep and irrigated with 5% NaOCl between each file size. In group C. the teeth were instrumented with GT file according to the manufacture's instructions using RC-prep and irrigated with 5% NaOCl between each file size. Then. in all teeth. a final flush of 5ml of distilled water delivered for 30s. Canals were dried with sterile standardized paper points. After preparing the canals, the teeth were sectioned along their mesial and diatal surfaces by using low-speed diamond disc. chisel and mallet. Each root section was then dehydrated in graded concentration of alcohol (70, 80, 90, 100%). mounted on an aluminum stub. sputter-coated with gold-palladium and observed with scanning electron microscope (HITACHI S-4200) in middle and apical area. The results of this study were as follows: 1. In the middle area. group B and group C showed less smear layer than group A and it was statistically significant (p < 0.05). 2. In the middle area. group B showed greater smear layer than group C. but it was not statistically significant (p > 0.05). 3. In the apical area, group C showed less smear layer than group A. and it was statistically significant (p < 0.05). 4. In the apical area. group A showed greater smear layer than group B. but it was not statistically significant (p > 0.05). 5. In the apical area. group B showed greater smear layer than group C. but it was not statistically significant (p > 0.05). 6. In all groups. the middle area was less smear layer than the apical area. and it was statistically significant (p < 0.05).

중간층 레진 적용이 단일 접착과정 상아질 접착제의 접착에 미치는 영향 (Effect of the additional application of a resin layer on dentin bonding using single-step adhesives)

  • 최승모;박상혁;최경규;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제32권4호
    • /
    • pp.313-326
    • /
    • 2007
  • 본 연구는 단일 접착과정 상아질 접착제와 복합레진 사이에는 부적합성이 존재하며, 이를 개선하기 위해 중간 레진층이 필요하다는 가설을 규명하기 위해 시행되었다. 발치된 치아의 협설측 상아질에 3종의 단일 접착과정 상아질 접착제를 도포 후 광중합, 2종의 중간 레진층 적용, 광중합 또는 자가중합형 복합레진의 사용여부에 따라 30개의 실험군으로 분류하였다. 미세전단 결합강도를 측정하고 투과전자현미경 (TEM)을 이용하여 접착계면에서의 미세 누출과 수분의 이동경로를 관찰하여 접착제의 투과성을 평가하여 다음과 같은 결론을 얻었다. 중간 레진층을 적용 시 접착층의 투과도가 감소되었고 복합레진에 대한 단일 접착과정 상아질 접착제의 결합강도가 증가되었다. 따라서 시간 절약 및 간단한 접착과정을 선호하여 단순화된 상아질 접착제를 선택하는 것은 재고되어야 한다.

1급 와동에서 상아질과 복합레진의 결합강도에 대한 중합방법의 효과 (THE EFFECT OF DIFFERENT CURING MODES ON COMPOSITE RESIN/DENTIN BOND STRENGTH IN CLASS ICAVITIES)

  • 백신영;조영곤;송병춘
    • Restorative Dentistry and Endodontics
    • /
    • 제33권5호
    • /
    • pp.428-434
    • /
    • 2008
  • 본 연구는 1급 복합레진 수복물에서 할로겐 광조사기를 이용한 4가지 중합방법이 상아질의 결합강도에 미치는 효과를 알아보기 위하여 시행하였다. 발거된 상 하악 대구치 20개의 교합면측 법랑질을 Diamond Wheel Saw를 이용하여 제거한 후 1급 와동을 형성하였다. 중합방법에 따라 파동지연 중합방법 (PD) 군, 연성 중합방법 (SS) 군, 파동 중합방법 (PC) 군, 지속 중합방법 (CC) 군의 4개 군으로 분류하고, Z250 복합레진을 각 군의 와동에 충전한 후 광조사하였다. 각 군의 시편을 주수하에 접착계면의 단면적이 $1mm^2$가 되도록 절단하여 막대모양의 시편을 제작하였고, 각 군당 20개의 시편을 사용하여 미세인장 결합강도를 측정하여 다음과 같은 결과를 얻었다. 1. PD 군은 PC 군과 CC 군보다 통계학적으로 더 높은 미세인장 결합강도를 나타내었다. 2. SS군의 미세인장 결합강도는 PC 군과 CC 군보다 높게 나타났으나, 통계학적으로 유의한 차이를 나타내지 않았다. 결론적으로, 1급 복합레진 수복물을 중합할 때 파동지연 중합방법과 연성 중합방법을 사용하여 중합속도를 조절함으로써 상아질과 복합레진의 결합강도를 개선할 수 있을 것으로 사료된다.

이온 빔 조사된 SiNx 박막의 전기 광학적 특성에 관한 연구 (Investigation on EO Characteristics of SiNx Thin Film Irradiated by Ion-beam)

  • 이상극;오병윤;김병용;한진우;김영환;옥철호;김종환;한정민;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.429-429
    • /
    • 2007
  • For various applications of liquid crystal displays (LCDs), the uniform alignment of liquid crystal (LC) molecules on treated surfaces is significantly important. Generally, a rubbing method has been widely used to align the LC molecules on polyimide (PI) surfaces. Rubbed PI surfaces have suitable characteristics, such as uniform alignment. However, the rubbing method has some drawbacks, such as the generation of electrostatic charges and the creation of contaminating particles. Thus, we strongly recommend a non contact alignment technique for future generations of large high-resolution LCDs. Most recently, the LC aligning capabilities achieved by ultraviolet and ion-beam exposures which are non contact methods, on diamond-like carbon (DLC) inorganic thin film layers have been successfully studied because DLC thin films have a high mechanical hardness, a high electrical resistivity, optical transparency, and chemical inertness. In addition, nitrogen-doped DLC (NDLC) thin films exhibit properties similar to those of the DLC thin films and a higher thermal stability than the DLC thin films because C:N bonding in the NDLC thin filmsis stronger against thermal stress than C:H bonding in the DLC thin films. Our research group has already studied the NDLC thin films by an ion-beam alignment method. The $SiN_x$ thin films deposited by plasma-enhanced chemical vapor deposition are widely used as an insulation layer for a thin film transistor, which has characteristics similar to those of DLC inorganic thin films. Therefore, in this paper, we report on LC alignment effects and pretilt angle generation on a $SiN_x$, thin film treated by ion-beam irradiation for various N ratios

  • PDF

사용자중심 의료공간을 위한 서비스디자인 프로세스의 적용사례 (Case of Service Design Process for Medical Space Focused on Users)

  • 노미경
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제21권4호
    • /
    • pp.27-36
    • /
    • 2015
  • Purpose: Of late, the focus of service design is moving toward emphasizing customer satisfaction and taking users' experience more seriously. In addition to the change in perspective in service design, scholars in this area are paying more attention to service design methodology and process, as well as its theory and real-world case studies. In the case of medical space, there have been few studies in attempting to apply service design methods useful for deriving user-focused results. The author of this paper believes, however, case study-oriented approaches are more needed in this area rather than ones focusing on theoretical aspects. The author hopes thereby to expand the horizon to practical application of spatial design beyond service design methodology. Methods: In order to incorporate the strengths of service design methodology that can reflect a variety of user opinions, this study will introduce diverse tools in the framework of double diamond process. In addition, it will present field cases that successfully brought about best results in medical space design. It will end with summarizing the ideal process of medical space design which is reasonable and comprehensive. Results: Medical service encompasses preventive medicine as well as treatment of existing medical conditions. A study in establishing the platform of medical service design consists of a wide range of trend research, followed by the summary of two-matrix design classification based on results of the trend research. The draft of design process is divided into five stages composed of basic tools for establishing spatial flow lines created by matching service design tools with each stage of space design processes. In all this, most important elements to consider are communication and empathy. When service design is actually applied to space design, one can see that output has reflected the users' needs very well. The service design process for user-oriented medical space can thus be established by interactions on the final outcome and feedback on the results. Implications: One can see that the service design with the hospital at its center produces the result that encompasses the user's needs best. If the user-focused service design process for medical space can be extended to other space designs, the author believes that it would enhance the level of satisfaction for users and minimize trials and errors.

ECR-PECVD 방법으로 제작된 DLC 박막의 기판 Bias 전압 효과

  • 손영호;정우철;강종석;정재인;황도원;김인수;배인호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.188-188
    • /
    • 2000
  • DLC (Diamond-Like Carbon) 박막은 높은 경도와 가시광선 및 적외선 영역에서의 광 투과도, 전기적 절연성, 화학적 안정성 및 저마찰.내마모 특성 등의 우수한 물리.화학적인 물성을 갖고 있기 때문에 여러 분야의 응용연구가 이루어지고 있다. 이러한 DLC 박막을 제작하는 과정에는 여러 가지가 있으나, 본 연구에서는 ECR-PECVD electron cyclotron resonance plasma enhanced chemical vapor deposition) 방법을 사용하였다. 이것은 최근에 많이 이용되고 있는 방법으로, 이온화률이 높을뿐만 아니라 상온에서도 성막이 가능하고 넓은 진공도 영역에서 플라즈마 공정이 가능한 장점이 있다. 기판으로는 4" 크기의 S(100)를 사용하였고, 박막을 제작하기 전에 진공 중에서 플라즈마 전처리를 하였다. 플라즈마 전처리는 Ar 가스를 150SCCM 주입시켜 5$\times$10-1 torr 의 진공도를 유지시키면서, ECR power를 700W로 고정하고, 기판 bias 전압을 -300 V로 하여 5분 동안 기판을 청정하였다. DLC 박막은 ECR power를 700W. 가스혼합비와 유량을 CH4/H2 : 10/100 SCCM, 증착시간을 2시간으로 고정하고, 기판 bias 전압을 0, -50, -75, -100, -150, -200V로 변화시켜가면서 제작하였다. 이때 ECR 소스로부터 기판까지의 거리는 150mm로 하였고, 진공도는 2$\times$10-2torr 였으며, 기판 bias 전압은 기판에 13.56 MHz의 RF power를 연결하여 RF power에 의해서 유도되는 negative DC self bias 전압을 이용하였다. 제작된 박막을 Auger electron spectroscopy, elastic recoil detection, Rutherford backscattering spectroscopy, X-ray diffraction, secondary electron microscopy, atomic force microscoy, $\alpha$-step, Raman scattering spectroscopu, Fourier transform infrared spectroscopy 및 micro hardness tester를 이용하여 기판 bias 전압이 DLC 박막의 특성에 미치는 영향을 조사하였다. 분석결과 본 연구에서 제작된 DLC 박막은 탄소와 수소만으로 구성되어 있으며, 비정질 상태임을 알 수 있었다. 기판 bias 전압의 증가에 따라 박막의 두께가 감소됨을 알 수 있었고, -150V에서는 박막이 거의 만들어지지 않았으며, -200V에서는 기판 표면이 식각되었다. 이것은 기판 bias 전압과 ECR 플라즈마에 의한 이온충돌 효과 때문으로 판단되며, 150V 이하에서는 증착되는 양보다 re-sputtering 되는 양이 더 많을 것으로 생각된다. 기판 bias 전압을 증가시킬수록 플라즈마에 의한 이온충돌 현상이 두드러져 탄소와 결합하고 있던 수소원자들이 떨어져 나가는 탈수소화 (dehydrogenation) 현상을 확인할 수 있었으며, 이것은 C-H 결합에너지가 C-C 결합이나 C=C 결합보다 약하여 수소 원자가 비교적 해리가 잘되므로 이러한 현상이 일어난다고 판단된다. 결합이 끊어진 탄소 원자들은 다른 탄소원자들과 결합하여 3차원적 cross-link를 형성시켜 나가면서 내부 압축응력을 증가시키는 것으로 알려져 있으며, hardness 시험 결과로 이것을 확인할 수 있었다. 그리고 표면거칠기는 기판 bias 전압을 증가시킬수록 더 smooth 해짐을 확인하였다.인하였다.

  • PDF

치과드릴 구동용 신 소형 2축 및 3축형 증속기어 강도특성 비교 (Strength Analyses of New 2- and 3-Axis-Type Small Multiplying Gears in Dental Hand-Pieces)

  • 김철;김주영;이중호;곽세호
    • 대한기계학회논문집A
    • /
    • 제36권9호
    • /
    • pp.1027-1032
    • /
    • 2012
  • 치과 드릴치료기기 내부에 장착되는 신개념 소형 증속기어 및 그 배열의 2가지 개념설계안을 도출하고, 증속비, 모듈, 이의 수, 기어지름, 기어의 형태를 기구학적 계산으로 했으며, 이 두 형태의 증속기어열에 대해서 이의 접촉과 굽힘 강도특성을 AGMA식과 유한요소해석으로 분석하고, DLC 재료를 이에 코팅했을 때의 접촉강도를 계산하였다. 또한 기어재료에 대한 피로강도시험 및 인장시험을 수행하여 강도해석에 활용하였다. 3축방식보다 좀더 단순한 2축방식의 2번 맞물린 기어에 약간 더 큰 응력이 발생했으며, 피로해석 결과를 S-N 선도와 비교할 때 요구되는 수명을 만족함을 알 수 있었다. 고경도의 DLC 코팅된 기어의 접촉응력이 동일한 기어에서 그렇지 않은 기어에 비해 약 30% 정도 감소하여서 이 표면의 코팅이 중요함을 알 수 있다. 이러한 연구결과를 기초로 초소형 2축방식의 기어열과 핸드피스를 시제작하여 작동성능을 평가하였다.

광중합 복합레진 수복시 여러 광조사 방법에 따른 미세변연누출에 관한 연구 (MICROLEAKAGE OF CL V COMPOSITE RESTORATIONS USING VARIOUS LIGHT CURING METHODS)

  • 양철영;유현미;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.299-308
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate the microleakage of 5 curing methods in class V composite restorations which are composed of two-step light curing, pulse-delay cure, low curing-light intensity, moderate curing-light intensity and high curing-light intensity. In this study, class V cavities were prepared on buccal and lingual surfaces of 50 extracted human upper or lower molars on cementum margin. Single Bond adhesive and Z-100 shade A2 were applied for each group following the manufacture's instruction. The experimental teeth were randomly divided into 5 groups of 10 samples (20 surfaces) each. Group 1: two-step light curing; Group 2: pulse-delay cure; Group 3: low curing-light intensity; Group 4: moderate curing-light intensity; Group 5: high curing-light intensity. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 60 teeth were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen was then observed with a stereomicroscope at ${\times}20$. The composite resin/tooth interfaces were examined under Scanning Electron Microscopy. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA and Dunn's Method. The results of this study were as follows. 1. In all groups, the leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. No group in this study showed significant differences in leakage values at both the enamel and the dentin margins(P<0.05). 3. In all groups, the gaps seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 4. The gaps in this study showed significant differences and two-step light-curing and low curing-light intensity produced significant less gap than high curing-light intensity(P<0.05).

  • PDF