• Title/Summary/Keyword: Diameter size

Search Result 3,703, Processing Time 0.029 seconds

Analysis of Sodium Spray Fire Using Gaussian Droplet Size Distribution (Gaussian 액적 크기 분포 함수를 이용한 분무형 화재 현상 해석)

  • Kim, B.H.;Hahn, D.H.;Suh, S.H.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.1
    • /
    • pp.72-81
    • /
    • 2004
  • Study on the analysis of sodium spray fire using Gaussian drop size distribution, which redistributes a droplet spectrum with given mean diameter if its size classes with critical diameter(D>8mm) occur, was carried out. In this case, the oversized droplets were reduced to a stable diameter. Results calculated by the code using Gaussian drop size distribution were in better agreement with AI experimental results than those of NACOM and SPRAY code. The effect of variance on pressure in the test cell appeared greatly by introducing Gaussian function, which could represent various sodium droplet size distribution. The increase of the variance with mean droplet size resulted had an important effect upon the pressure in the test cell.

Size Control of Gold Nanoparticles by Heat Treatment and Its Use as a Catalyst for Single-Walled Carbon Nanotube Growth (열처리를 통한 금 나노입자의 크기 제어와 일벽 탄소나노튜브의 합성 촉매로의 이용)

  • Lee, Seung-Hwan;Jeong, Goo-Hwan
    • Korean Journal of Materials Research
    • /
    • v.23 no.12
    • /
    • pp.737-744
    • /
    • 2013
  • We demonstrated size control of Au nanoparticles by heat treatment and their use as a catalyst for single-walled carbon nanotube (SWNTs) growth with narrow size distribution. We used uniformly sized Au nanoparticles from commercial Au colloid, and intentionally decreased their size through heat treatment at 800 oC under atmospheric Ar ambient. ST-cut quartz wafers were used as growth substrates to achieve parallel alignment of the SWNTs and to investigate the size relationship between Au nanoparticles and SWNTs. After the SWNTs were grown via chemical vapor deposition using methane gas, it was found that a high degree of horizontal alignment can be obtained when the particle density is low enough to produce individual SWNTs. The diameter of the Au nanoparticles gradually decreased from 3.8 to 2.9 nm, and the mean diameter of the SWNTs also changed from 1.6 to 1.2 nm for without and 60 min heat treatment, respectively. Raman results reconfirmed that the prolonged heat treatment of nanoparticles yields thinner tubes with narrower size distribution. This work demonstrated that heat treatment can be a straightforward and reliable method to control the size of catalytic nanoparticles and SWNT diameter.

A study on the determination of an optimal handle diameter for a signal billy (신호봉 손잡이의 최적 굵기 결정에 관한 연구)

  • 변승남;이동훈
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.15-27
    • /
    • 1997
  • The objectives of this study were twofold; (1) to determine an optimal handle size of a signal billy, based on the subjective assessment of grip comfort and (2) to investigate the relationship between hand anthropometry and the optimal handle size. Thirty-seven university male students were asked to rate seven cylindrical handles of different diameters in barehanded and gloved conditions, respectively. Among these handles, 3.5cm diameter of the handle size was found to be the most comfortable, in both bardhanded and gloved conditionsl. However, no statistically significant reduction in grip comfort occurred within handle diameter ranging from 2.5cm to 4.0cm. As the handle diameter was deivated from the range, grip discomfort in creased significantly. A Spearman rank correlation coefficient test revealed that hand anthropometries such as finger lengths, hand circumference, and hand thickness were statistically significant factors on the determination of the optimal handle size. The implications of these findings were discussed. The results of this study can be used as guidelines in designing the hand tools for power grip.

  • PDF

Transcatheter closure of small ductus arteriosus with amplatzer vascular plug

  • Cho, Eun Hyun;Song, Jinyoung;Kang, I-Seok;Huh, June;Lee, Sang Yoon;Choi, Eun Young;Kim, Soo Jin
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.9
    • /
    • pp.396-400
    • /
    • 2013
  • Purpose: The purpose of this study was to share our experience of transcatheter closure of small patent ductus arteriosus (PDA) by using an Amplatzer vascular plug (AVP). Methods: We reviewed the medical records of 20 patients who underwent transcatheter closure at Samsung Medical Center and Sejong General Hospital from January 2008 to August 2012. The size and shape of the PDAs were evaluated by performing angiograms, and the PDA size and the AVP devices size were compared. Results: The mean age of the patients was $54.9{\pm}45.7$ months old. The PDAs were of type C (n=5), type D (n=12), and type E (n=3). The mean pulmonary end diameter of the PDA was $1.7{\pm}0.6$ mm, and the aortic end diameter was $3.6{\pm}1.4$ mm. The mean length was $7.3{\pm}1.8$ mm. We used 3 types of AVP devices: AVP I (n=5), AVP II (n=7), and AVP IV (n=8). The ratio of AVP size to the pulmonary end diameter was $3.37{\pm}1.64$, and AVP size/aortic end ratio was $1.72{\pm}0.97$. The aortic end diameter was significantly larger in those cases repaired with AVP II than in the others (P=0.002). The AVP size did not significantly correlate with the PDA size, but did correlate with smaller ratio of AVP size to aortic end diameter ($1.10{\pm}0.31$, P=0.032). Conclusion: Transcatheter closure of small PDA with AVP devices yielded satisfactory outcome. AVP II was equally effective with smaller size of device, compared to others.

An Estimation on the Stability of W/O Type Emulsified Fuel Using by Capacitance Sensor (정전용량센서를 이용한 W/O형 유화연료의 안정성 평가)

  • Cho, Seong-Cheol;Oh, Yang-Hwan;Im, Seok-Yeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.95-101
    • /
    • 2011
  • We estimated on the stability of W/O type emulsified fuel using by capacitance sensor, so it concluded the following conclusions. For the first 24 hours, prepared emulsified fuel reveals phase separation ratio of 5%, maintains stable status which verifies the stability of emulsified fuel. Adding more water increases the phase separation ratio rapidly, and adding more surfactant displays stable emulsification. Adding water causes larger size of water droplet diameter, and adding surfactant mixture causes smaller size of water droplet diameter. In conclusion, the size of W/O type emulsified fuel water droplet diameter is directly related to the volume of surfactant, and density of water droplet diameter changes thedistribution according to water contents.

A Numerical Analysis on Prediction of Cut-diameter according to Vane Outflow Angle in the Axial-flow Cyclone (축상유입식 사이클론의 베인 유출각도에 따른 절단입경 예측에 관한 수치해석)

  • Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.111-117
    • /
    • 2012
  • Dust collecting performance of axial-vane type cyclone for oil mist was analyzed in this study. For predicting cut diameter size of cyclone, the number and angle of vane ($tan{{\beta}_2}^{\prime}$) was simulated by CFD. As the result, $tan{{\beta}_2}^{\prime}$ was decreased as the number of vane was increased and the angle of inclination(${{\beta}_2}^{\prime}$) decreased, and it cause strong swirl flow. Therefore, it could be confirmed that as the number of vane was increased and the angle of inclination was decreased, cut diameter size was decreased. Also, by verifying the results of CFD through experiment, the cut diameter size could be $2{\mu}m$ at $4m^3/min$ of flow rate.

Optimum Tapping Size and Number for Sap Collection of Acer mono (고로쇠나무 수액 채취를 위한 적정 천공 크기와 천공 수)

  • Moon, Hyun-Shik;Kwon, Su-Duk
    • Journal of Ecology and Environment
    • /
    • v.29 no.3
    • /
    • pp.185-189
    • /
    • 2006
  • Optimum tapping size and number for sap collection were investigated to minimize damage on tree growth and secure resources for sap by sap collection of Acer mono. The amounts of sap collected by tapping size of 12 mm, 10 mm and 8 mm was 189 L, 140 L and 193 L, respectively. Fusion rates by tapping size were 100% for 8 mm, 89% for 10 mm and 85% for 12 mm, respectively. Amount of sap by size and number of tapping were much at three, two and three tappings to small, middle and large diameter tree in case of 8 mm tapping, and it was large in quantity at two tappings of 12 mm tapping to large diameter tree, respectively. Trees tapped from one to three tappings of 8 mm size for small diameter tree with treatment of DB ointment (mixture of thiophane ointment and 2% bamboo charcoal powder) were completely filled up within 6 months. Diameter growth by number of tapping of 8 mm size was 0.60 mm for one tapping, 1.12 mm for two tappings and 0.47 mm for three tappings to small, middle and large diameter tree, respectively. In case of 12 mm tapping size, diameter growth was fast in the order of large (0.55 mm), middle (0.30 mm) and small (0.23 mm) diameter tree, respectively.

Genetic Analyzed of Quantitative Characters in Perilla (들깨 품종집단에 대한 몇 개 양적 형질의 유전분석)

  • 정원복;정대수
    • Journal of Life Science
    • /
    • v.8 no.4
    • /
    • pp.431-436
    • /
    • 1998
  • These studies were carried out to obtain useful information about the effective selection of vegetable perilla by estimating the genetic relationships between the heritabilities and the genetic correlations of quantitative traits among eight agronomic characters from 91 perilla varieties. The positive correlations were showed among characters such as between leaf weight and leaf size, leaf weight and leaf length, leaf weight and leaf width, leaf weight and plant height, leaf weight and stem diameter, leaf size and leaf length, leaf size and leaf width, leaf size and plant height, leaf size and stem diameter , leaf length and leaf width, leaf length and plant height, leaf length and stem diameter, leaf width and plant height, leaf width and stem diameter, plant height and stem diameter, plant height and the number of internodes per plant, and the number of internodes per plant and the number of leaves per plant. Heritabilities were high as from 0.7311 to 0.9112 among leaf weight, leaf size, leaf length, leaf width, plant height, stem diameter, and the number of internodes per plant.

  • PDF

THE ANALYSIS OF INITIAL APICAL FILE SIZE BEFORE AND AFTER CORONAL FLARING (Coronal flaring 전, 후 초기근관장 파일크기의 분석)

  • Hwang, Ho-Keel;Park, Chan-Ho;Bae, Seong-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.64-71
    • /
    • 2003
  • The purpose of this study was to compare the initial apical file(IAF) first Ole that fits to the apex in each canal before and after early flaring to analyze if the size of file to fit to the apex would increase after flaring. Eighty anterior teeth with complete apical formation and patent foramens were selected. The samples were randomly divided into 4 groups(GG, OS, GT, PT Group) of 20 teeth each. A file was fit to the apex in each canal and that size recorded. Radicular flaring were completed using different types of instruments. After flaring a file was again fit to the apex in the same manner as before and its size recorded. The results of this study were as follows : 1. The mean diameter of IAF before flaring(file diameters in $mm{\times}10^{-2}$) was $19.81{\pm}8.32$ before and $25.94{\pm}9.21$ after(p<0.05). 2. The increase in diameter of IAF was approximately one file size for all groups. 3. Ranking of increasing diameter of IAF were GG>CT>OS>PT group. There was a statistically significant difference between before and after flaring(p<0.05). 4 Ranking of the time for flaring were GG>GT>OS>PT group. There was a statistically significant difference between GG group and other groups(p<0.05). 5. In the case without change of IAF diameter, they showed decrease in force after flaring when IAF was pulled out from root canal(p<0.05). This study suggested that early radicular flaring increases the file size that is snug at the apex, and awareness of that difference gives the clinician a better sense of canal size. Early flaring of the canal provides better apical size information and with this awareness, a better decision can be made concerning the appropriate final diameter needed for complete apical shaping.

The Wall Shear Rate Distribution Near an End-to-End Anastomosis : Effects of Graft Compliance and Size

  • Rhee, Kye-Han
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.41-47
    • /
    • 2003
  • The patency rates of small diameter vascular grafts are disappointing because of the formation of thrombus and intimal hyperplasia. Among the various factors influencing the success of graft surgery, the compliance and the size of a graft are believed to be the most important physical properties of a vascular graft. Mismatch of compliance and size between an artery and a graft alters anastomotic flow characteristics, which may affect the formation of intimal hyperplasia. Among the hemodynamic factors influencing the development of intimal hyperplasia, the wall shear stress is suspected as the most important one. The wall shear stress distributions are experimentally measured near the end-to-end anastomosis models in order to clarify the effects of compliance and diameter mismatch on the hemodynamics near the anastomosis. The effects of radial wall motion, diameter mismatch and impedance phase angle on the wall shear rate distributions near the anastomosis are considered. Compliance mismatch generates both different radial wall motion and instantaneous diameter mismatch between the arterial portion and the graft portion during a flow cycle. Mismatch in diameter seems to be affecting the wall shear rate distribution more significantly compared to radial wall motion. The impedance phase angle also affects the wall shear rate distribution.

  • PDF