현장공기분사공정법(IAS)을 이용한 공기 영향반경과 흐름 양상 연구

  • 이준호;박갑성
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.213-217
    • /
    • 2004
  • Laboratory scale study for an area of influence and flowing aspect of groundwater saturated zone was conducted for three sediment grains. On the AMG(Average Modal diameter Grains) 0.34, 1.38, 3.89mm diameter samples, the affected area of the aquifer were 15.2, 37.0, 30.0%/m2 each. Air flow for AMG 0.34mm diameter grain size provides indication of pattern of channelized air flow in saturated zone and expansion state in above saturated zone. For AMG of 1.38, 3.89mm diameter grains, air flow are pervasive air flow, forming a symmetrical cone of influence around the injection point. And also AMG 1.38, 3.89mm diameter samples show onset of collapse and approach to steady state in above saturated zone, respectively. In this study, optimal sites for in situ air sparging, may be grain diameters between about AMC 1.5~2.5mm diameter.

  • PDF

A Study on the Wide Reach Nozzle of Sprayer(IV) (Characteristics of cap hole diameter and pressure for the medium range nozzle) (휴반용 분무기의 Nozzle에 관한 연구(IV) (중거리용 Nozzle예 있어서 구경과 압력의 특성))

  • 옹장우;이상우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.3
    • /
    • pp.3872-3877
    • /
    • 1975
  • This study was conducted to examine the effects of the change of cap hole diameter and pressure on the travelling distance and the sprayed particle size for the medium range nozzle. The results of this study are summarized as follows; 1) The effective travelling distance was about from 1 meter to 8 meters and centro-position of the travelling distance was about 3 or 5 meters. 2) Main effect of change of cap hole diameter for the travelling distance was a slight convex quadratic curve. 3) Main effect of change of pressure increased linearly, its increasing rate about 1.6 was large. 4) Sizes of sprayed particles were less than 250${\mu}$ generally and the sizes decreased according to the increasing of travelling distance. 5) Changes of diameter of sprayed particles by cap hole diameter increased in accordance with increasing of cap hole diameter. 6) Changes of diameter of sprayed particles by the groove depth of swirl plate was very slight.

  • PDF

Oogenesis in a Tubiculous Polychaete, Schizobranchia insignis Bush: I. Microscopic and Biometric Studies

  • Lee, Yang-Rim
    • The Korean Journal of Zoology
    • /
    • v.20 no.2
    • /
    • pp.77-92
    • /
    • 1977
  • A study has been made to correlate morphological and biochemical differentiation in the oocytes of a tubiculous polychaete, Schizobranchia insignis. The pressent paper is concerned with an examination of the cytological changes during oogenesis and annual size distribution of oocytes, The oocytes are released from the ovary into the coelomic sac at the end of the oogonial division and grow to a maximum size (180 $\\mu$ diameter). Oogensis takes place continuously throughout a year, although the breeding season is the period between January and March. When the oocytes reach the largest size class, they remain constant in size thereafter and accumulate in the coelomic sac. The nucleolus, which first appears in the oocytes 5-10$\\mu$ diameter, grows in the early stages of oogenesis, becomes maximum in the oocytes 100-120$\\mu$ diameter, and is constant throughout the rest of the pertiod. The nuclelus initially has a single comartment but becomes bipartite prior to vitello genesis. Three types of yolk including lipid droplets, proteid granules and oval granules oof unknown composition form at different times of oogenesis. The lipid droplets and oval granules appear in the early stage, but mainly in the oocytes larger than 80 $\\mu$ diameter. Proteid yolk and cortical granules appear only in the oocytes larger than 80 $\\mu$ diameter Microvilli are abundant in the oocyte 80 $\\mu$ diameter and embedded in the vitelline membranc. In the oocytes 180 $\\mu$ diameter they have retracted from the vitelline membrane.

  • PDF

Characteristics of Hypoxic Pulmonary Vasoconstriction of the Rat: Study by the Vessel Size and Location in the Lung

  • Lee, Sang-Jin;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.3
    • /
    • pp.321-328
    • /
    • 1999
  • Pulmonary blood vessels with diameters of $200{\sim}400\;{\mu}m$ produce considerably more force in response to vasoconstrictor drugs than those which are either smaller or larger. We have therefore investigated whether or not hypoxic pulmonary vasoconstriction (HPV) is more powerful in vessels of these diameters. We have also looked at the possibility that vessels from different regions of the lung respond differently. To do this we have grouped vessels according to their location within the lung as well as by size. We used a small vessel myograph (Cambustion AM10, Cambridge, UK) to study 208 preconstricted $(1\;{\mu}M\;PGF_{2{\alpha}})$ small pulmonary arteries $(300{\sim}800\;{\mu}m$ diameter when stretched to a tension equivalent to 25 mmHg transmural pressure) from 39 rats anaesthetized with 2% inspired halothane. A biphasic contraction was observed in response to hypoxia (ca. 25 mmHg $Po_2).$ The magnitudes of both the first, transient, phase (PT, peak tension) and of the second, sustained, phase (SST, steady state tension) were measured. The latter was measured 40 min after the start of hypoxia. The first phase was most pronounced in vessels with an average diameter of 423 ${\mu}m$ while the second phase was most pronounced in larger vessels (mean diameter 505 ${\mu}m).$ These maximal responses were all seen in vessels somewhat larger than reported by others. The responses of smaller vessels $(400{\sim}500\;{\mu}m)$ did not depend upon their location within the lung, but those of larger vessels $(600{\sim}700\;{\mu}m)$ showed regional differences. Those from the right lobe and those from the base of the lung gave the largest responses. It was especially noticeable that large vessels (631 ${\mu}m$ diameter) from the base of the right lung gave the biggest responses. Thus HPV seems to occur not in a uniform manner, dependent solely to the size of vessels, but it also depends to some degree on the region of the lung from which vessels have been taken. Furthermore, our results suggest that larger vessels, as well as smaller ones, may contribute significantly to HPV.

  • PDF

Variation of Flower Type Characteristics and Distribution in Mixed Population of Paeonia lactiflora Pallas (혼계 작약 집단의 화형특성 변이와 분포)

    • Korean Journal of Plant Resources
    • /
    • v.12 no.4
    • /
    • pp.297-302
    • /
    • 1999
  • This study was carried out to find morphological characters of flower and its distribution in mixed population of Paeonia lactiflora Pallas. In distribution of flowering periods, early, medium, and late matured type were 18%, 56%, and 26%, respectively. Flowering duration was less than eight days in 9% of flowers. In next 9 to 11 days, 12 to 14 days and more than 15 days showed, 50%, 37% and 4% respectively. For flower sizes, small size below 9cm diameter were 11%, medium size between 9 to 13cm diameter and large size above 13cm diameter were 65% and 24%, respectively. Among six kinds of flower colors - red, red pink, pink, light pink, pale yellow and white, pink color flowers was dominant, showed 56%. In flower types, single flower was 76%, and anemone, crown, bomb and japanese types were also present. Flower stem diameter were positively correlated with flowering duration, flower size and number of stamens, and negatively correlated with number of stamens and pistils, number of pistils and petals.

  • PDF

Measurement of the Single and Size-Classified Raindrops

  • Ma, Chang-Jin;Mikio Kasahara;Hwang, Kyung-Chul;Park, Kum-Chan;Kim, Hui-Kang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.E
    • /
    • pp.73-79
    • /
    • 1999
  • To Characterize the single raindrops as a function of their size we designed the sampling and handling apparatuses. Samplings of single and size- classified raindrops were performed at a height of 20m above the ground level of a Kyoto University building located in Uji, Japan in rain events from middle of July to the end of August, 1999. And PIXE method was applied to the analysis of single raindrops sampled as a function of their size. Diameter change of frozen raindrops by liquid nitrogen did nto affect the size segregation ability of our sampling apparatus. The number of raindrops increases with decreasing drop size. And it is found that the size distribution of raindrops verified depends on the rain events. Application of PIXE analysis to the measurement of single raindrops was very successful. Every element showed a continuous increase in concentration with decreasing raindrop diameter. It seems reasonable to say that our work should be helpful to obtain more detailed information on single raindrops and especially to study on the rainout and washout mechanisms.

  • PDF

The Fabrication of High Strength 7XXX Aluminum Alloy Powders by Centrifugal Disc Atomization (원심분무법에 의한 고강도 7XXX 알루미늄 합금 분말의 제조)

  • Lee, Tae-Hang;Im, Seong-Moo;Cho, Sung-Suk
    • Journal of Korea Foundry Society
    • /
    • v.10 no.6
    • /
    • pp.528-537
    • /
    • 1990
  • 7XXX aluminum alloy powders produced by the self-manufactured rotating disc atomizer were investigated to determine the influence of the atomization parameters on the particle size distributions in air atmosphere. The particle size distributions are almost always bimodal with the dominant mode on the large particle size. Average powder size of 7XXX aluminum alloy is $74/{\mu}m~125/{\mu}m$ when melt is poured with the rate of 9g /sec at 730$^{\circ}C$ on a rotating disc of 30㎜ diameter at 6300rad/sec. The mass of finer particle increased when disc diameter, angular velocity, pouring temperature increased and pouring rate decreased. The powder shapes of bimodal change from acicular to tear-drop and from tear-drop to ligament with increasing powder size. Powder shape was determined by the atomization mechanism and oxidation in liquid state. Microstructure of powders appeared to be cell and cellular dendrite. The SDAS of Al-7.9wt%Zn-2.4wt%Mg-1.5wt%Cu-0.9wt%Ni Powders is $0.8{\mu}m~1.0{\mu}m$ for the powders of $size+44{\mu}m~53{\mu}m$ and $1.6{\mu}m∼1.8{\mu}m$ for the powders of $size+105{\mu}m~125{\mu}m$, repectively.

  • PDF

Method of tumor volume evaluation using magnetic resonance imaging for outcome prediction in cervical cancer treated with concurrent chemotherapy and radiotherapy

  • Kim, Hun-Jung;Kim, Woo-Chul
    • Radiation Oncology Journal
    • /
    • v.30 no.2
    • /
    • pp.70-77
    • /
    • 2012
  • Purpose: To evaluate the patterns of tumor shape and to compare tumor volume derived from simple diameter-based ellipsoid measurement with that derived from tracing the entire tumor contour using region of interest (ROI)-based 3D volumetry with respect to the prediction outcome in cervical cancer patients treated with concurrent chemotherapy and radiotherapy. Materials and Methods: Magnetic resonance imaging was performed in 98 patients with cervical cancer (stage IB-IIIB). The tumor shape was classified into two categories: ellipsoid and non-ellipsoid shape. ROI-based volumetry was derived from each magnetic resonance slice on the work station. For the diameter-based surrogate "ellipsoid volume," the three orthogonal diameters were measured to calculate volume as an ellipsoid. Results: The more than half of tumor (55.1%) had a non-ellipsoid configuration. The predictions for outcome were consistent between two volume groups, with overall survival of 93.6% and 87.7% for small tumor (<20 mL), 62.9% and 69.1% for intermediate-size tumor (20-39 mL), and 14.5% and 16.7% for large tumors (${\geq}$40 mL) using ROI and diameter based measurement, respectively. Disease-free survival was 93.8% and 90.6% for small tumor, 54.3% and 62.7% for intermediate-size tumor, and 13.7% and 10.3% for large tumor using ROI and diameter based method, respectively. Differences in outcome between size groups were statistically significant, and the differences in outcome predicted by the tumor volume by two different methods. Conclusion: Our data suggested that large numbers of cervical cancers are not ellipsoid. However, simple diameter-based tumor volume measurement appears to be useful in comparison with ROI-based volumetry for predicting outcome in cervical cancer patients.

Advanced Design of Birdcage RF Coil for Various Absorption Regions at 3T MRI System

  • Lee, Jung-Woo;Choe, Bo-Young;Choi, Chi-Bong;Huh, Soon-Nyoung
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.9 no.1
    • /
    • pp.48-60
    • /
    • 2005
  • Purpose: The purpose of this study was to design and build an optimized birdcage resonator configuration with a low pass filter, which would facilitate the acquisition of high-resolution 3D-image of small animals at 3T MRI system. Methods and Materials: The birdcage resonator with 12-element structures was built, in order to ensure B1 homogeneity over the image volume and maximum filling factor, and hence to maximize the signal to noise ratio (SNR) and resolution of the 3-dimensional images. The diameter and length of each element of a birdcage resonator were as follows: (1) diameter 13 cm, length 22 cm, (2) diameter 15 cm, length 22 cm, (3) diameter 17 cm, length 25 cm. Spin echo pulse sequence and fast spin echo pulse sequence were employed in obtaining MR images. The quality of the manufactured birdcage resonators wes evaluated on the basis of the return loss following matching and tuning process. Results: The experimental MR image of phantoms by the various manufactured birdcage resonators were obtained to compare the SNR in accordance with the size of objects. The size of an object to that of coil was identified by parameters that were estimated from the image of a phantom. First, the diameter of the birdcage resonator was 15cm, and the ratio of the tangerine to the birdcage resonator accounted for approximately 27%. The Q factor was 53.2 and the SNR was 150.7. Second, at the same birdcage resonator, the ratio of the orange was approximately 53%. The SNR and the Q parameter was 212.8 and 91.2, respectively. Conclusion: The present study demonstrated that if birdcage resonators have the same forms, SNR could be different depending on the size of an object, especially when the size of an object to that of coil is approximately 40~80%, the former is bigger than the latter. Therefore, when the size of an object to be observed is smaller than that of coil, the coil should be manufactured in accordance with the size of an object in order to obtain much more excellent images.

  • PDF