• Title/Summary/Keyword: Diameter Ratio

Search Result 3,096, Processing Time 0.028 seconds

Evaluation on Ground Characteristics of Weathered Granite Masses by Pressuremeter Test (공내재하시험에 의한 화강 풍화암의 지반 특성 평가)

  • Lee, Kwang-Hee;Bae, Kyung-Tae;Chang, Seo-Man;Lee, Chong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.831-838
    • /
    • 2004
  • To study on mechanical characteristics of weathered granite masses are difficult because of undisturbanced sampling and in-situ test. Generally, pressuremeter test is widely used to investigate the behavior of weathered rock masses. However, it has many problems to get a limit pressure because of cavity collapse, membrane damage, ete. This study aims to evaluate the mechanical characteristics of weathered granite masses using in-situ pressuremeter test and numerical analysis depending on the ratio of length and diameter of the membrane(L/D=5, 8, 10, 15, 20). Test results and data are shown that strength parameters are reduced exponentially varing weathering degree, and numerical analysis results are approximately coincided with the test results. And the ratio of length and diameter of the membrane arc not affected the parameters such as modulus of pressuremeter, shear modulus, etc. But limit pressure is increased decreasing membrane length based on numerical analysis. On the other hand, increasing the membrane length, yield pressure is decreased and plastic radius is increased in the case of same weathering degree.

  • PDF

Effects of Aspect Ratio on Combustion Characteristics in Diesel Engine (연소실 형상비가 디젤기관의 연소특성에 미치는 영향)

  • Kwon, S.I.;Kwon, J.B.;Kim, H.S.
    • Journal of ILASS-Korea
    • /
    • v.3 no.3
    • /
    • pp.23-32
    • /
    • 1998
  • The effect of reentrant type bowl geometry on combustion characteristics was investigated in a D.I. diesel engine. The main factor was the aspect ratio (Bowl Diameter / Bowl Depth) of bowl of combustion chamber, and the cylinder pressure, engine performance and emissions of the engine using the 4 kinds of the combustion chamber were meadured. Also, the combustion characteristics compared of the experimented and the calculated values which is used by the Hiroyasu's combustion model. The results are as follows; The effect of $d_c/H$ on ignition delay period are small. The smoke is corerelated to the heat release of the premixed and the diffusion combustion, i.g, the smoke decreased by decreasing the premixed combustion or increasing the diffusion combustion on cumulative heat release. The premixed combustion process has more effect than the diffusion combustion on smoke. The formal tendency of $d_c/H$ on engine performance has not appear.

  • PDF

A Study of Fine Fiber Formation and Physical Properties of Polyacrylonitrile Copolymer (폴리아크릴로니트릴 공중합체의 극세 섬유제조 및 그 물성)

  • Lee, Shin-Hee
    • Fashion & Textile Research Journal
    • /
    • v.14 no.3
    • /
    • pp.472-477
    • /
    • 2012
  • The conditions of wet spinning were considered in order to prepare the fine denier of acrylic fiber. Polyacrylonitrile copolymer was synthesized by the copolymerization of acrylonitrile (AN) and methyl acrylate (MA) initiated by an aqueous sulfite-chlorate redox system. Acrylic fiber was manufactured through wet-spinning in a dimethyl formamide (DMF) system. The conditions of wet-spinning were investigated by i-value, spinning speed, diameter of spinneret, draw ratio, water content of spinning dope and morphology of protofiber. The physical properties of fibers were investigated by Instron. In this experiment, the minimum i-value decreased with the decreasing spinneret diameter, an increased spinning speed, and an increased coagulation bath (CBC) concentration. The maximum draw ratio increased with an increased CBC. The optimum CBC and water content of the spinning dope were 60%-65% and 3.5%, respectively. The tenacity at the breaking point increased with a decreased fineness of fiber. The elongation at breaking point was almost the same value as a function of the fineness of fiber.

Study on the Oxidation Treatment of Nanoparticles for the Critical Heat Flux (임계열유속 향상을 위한 나노물질의 산화처리에 대한 연구)

  • Kim, Woo-Joong;Jeon, Yong-Han;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.6
    • /
    • pp.39-49
    • /
    • 2017
  • Pool boiling, one of the key thermal-hydraulics phenomena, has been widely studied for improving heat transfer efficiencies and safety of nuclear power plants, refrigerating systems, solar-collector heat pipes, and other facilities and equipments. In the present study, the critical heat flux (CHF) and heat-transfer coefficients were tested under the pool-boiling state using graphene M-5 and M-15 nanofluids as well as oxidized graphene M-5 nanofluid. The results showed that the highest CHF increase for both graphene M-5 and M-15 was at the 0.01% volume fraction and, moreover, that the CHF-increase ratio for small-diameter graphene M-5 was higher than that for large-diameter graphene M-15. Also at the 0.01% volume fraction, the oxidized graphene M-5 nanofluid showed a 41.82%-higher CHF-increase ratio and a 26.7%-higher heat-transfer coefficient relative to the same nanofluid without oxidation treatment at the excess temperature where the CHF of distilled water occurs.

Influence of Working Fluids to Heat Transfer Characteristics of Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery

  • Lee, Wook-Hyun;Im, Yong-Bin;Kim, Ju-Won;Kim, Jeung-Hoon;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.3
    • /
    • pp.27-35
    • /
    • 2001
  • Heat transfer characteristics of a heat exchanged for low temperature waste heat recovery using oscillating capillary tube heat pipe (OCHP) were evaluated against the charging ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working a 2.6mm in outside diameter, 1.44mm in inside diameter with 101m length and 140 turns. Charging ratio of working fluid was 40% and 50%. water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and 9~27 $4kg/m^2s$, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-142b and R-290 and it was proportional to Figure of Merit for thermosyphon. As a result, it was thought that R-22 was the most reasonable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

Influence of Working Fluids to Heat Transfer Characteristics of the Heat Exchanger using Oscillating Capillary Tube Heat Pipe for Low Temperature Waste Heat Recovery (저온 폐열회수용 진동세관형 히트파이프 열교환기의 작동 유체에 따른 열전달 특성)

  • 이욱현;임용빈;김정훈;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.659-666
    • /
    • 2000
  • Heat transfer characteristics of a heat exchanger for low temperature waste heat recovery using oscillating capillary tube heat pipe were evaluated against the charge ratio variation of working fluid and various working fluids. R-l42b, R-22 and R-290 were used as working fluids. The heat exchanger was composed of heat pipe with capillary tube bundles, having a 2.6mm in outer diameter, 1.4mm in inner diameter with 101m long, and 40 turns. Charge ratio of working fluid was 40% and 50%. Water was used as secondary fluid. Inlet temperature and mass velocity for each secondary fluid were 297 K, 280 K and9~27 kg /$m^2s$,, respectively. From experimental results, it was found that heat transfer performance of R-22 was higher than those of R-l42b and R-290 and it was proportional to Figure of merit for thermosyphons. As a result, it was thought that R-22 was the most suitable working fluid of waste heat recovery for low temperature waste heat recovery.

  • PDF

Axial load behavior and stability strength of circular tubed steel reinforced concrete (SRC) columns

  • Yan, Biao;Liu, Jiepeng;Zhou, Xuhong
    • Steel and Composite Structures
    • /
    • v.25 no.5
    • /
    • pp.545-556
    • /
    • 2017
  • The tubed steel reinforced concrete (SRC) column is a composite column in which the outer steel tube is mainly used to provide confinement on the core concrete. This paper presents experimental and analytical studies on the behavior of circular tubed SRC (TSRC) columns subjected to axial compression. Eight circular TSRC columns were tested to investigate the effects of length-to-diameter ratio (L/D) of the specimens, diameter-to-thickness ratio (D/t) of the steel tubes, and use of stud shear connectors on the steel sections. Elastic-plastic analysis on the steel tubes was used to investigate the mechanism of confinement on the core concrete. The test results indicated that the tube confinement increased the strength and deformation capacity for both short and slender columns, and the effects on strength were more pronounced for short columns. A nonlinear finite element (FE) model was developed using ABAQUS, in which the nonlinear material behavior and initial geometric imperfection were included. Good agreement was achieved between the predicted results using the FE model and the test results. The test and FE results were compared with the predicted strengths calculated by Eurocode 4 and the AISC Standard. Based on the analytical results, a new design method for this composite column was proposed.

An Experimental Study on Supersonic Jet Issuing from Gas Atomizing Nozzle (I) (가스 미립화용 노즐로부터 방출되는 초음속 분류에 관한 실험적 연구)

  • Kim, Hui-Dong;Lee, Jong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.2
    • /
    • pp.697-709
    • /
    • 1996
  • Supersonic axisymmetric jets issuing from various kinds of nozzles with a throat diameter of a few millimeters were experimentally investigated. The exit Mach number and Reynolds number based on the throat diameter of nozzle were in the range of 1.0 ~ 5.9 and 8.4$\times$ $10^4$ ~ 2.9$\times$$10^6$, respectively. The nozzle pressure ratio was varied from 5 to 85. Present paper aims to offer fundamental information of the supersonic free-jets, with an emphasis to give data with which the shape of the free-jets can be depicted under a specified condition. Experimental data are summarized to enable an estimation of the shape of the supersonic free-jets. The result shows that the shape of free-jets is dependent on only the nozzle pressure ratio.

A Method of Tending Practices for the Control of Stand Structure in Natural Mixed Stands (천연(天然) 혼효임분(混淆林分)의 구조조정(構造調整)을 위한 무육방법(撫育方法))

  • Shin, Man Yong;Bae, Sang Won;Lim, Joo-Hoon;Chun, Young Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.2
    • /
    • pp.155-163
    • /
    • 1994
  • This study was conduced to provide a method of tending practices for natural mixed stands, which have a possibility of inducing to selection cutting stand based on the analysis of stand structures. For this, first, diameter distribution for a balanced selection cutting stand was predicted using Q theory applied to natural stands. The method of estimating diminution ratio coefficient Q is presented. The possible tending practice method which could be adopted to natural stands is discussed based on two different diameter distributions and side conditions.

  • PDF

A Study on the Center Hole of Korean Traditional Kite with Aspect Ratio 1:1.5 (가로세로비 1:1.5를 가진 한국 전통 지연의 방구멍에 대한 연구)

  • Sah, Jong-Youb
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.4
    • /
    • pp.243-254
    • /
    • 2020
  • Korean traditional kite has the unusual shape of the elongated rectangle with the center hole. The aerodynamic forces are numerically computed on Korean traditional kite with aspect ratio 1:1.5 by using FLUENT software. Simulating the flight of the kite with various diameters of the center hole, the present study has investigated the role of the center hole as well as the effect of diameter of the center hole. The center hole plays a role in relieving the sudden increase of tension associated with fast rewinding of the kite thread in kite fighting, thereby enabling faster rewinding of the kite thread. The proper diameter of the center hole is 1/3 of the width.