• 제목/요약/키워드: Diagrid structures

검색결과 31건 처리시간 0.025초

Collapse assessment and seismic performance factors in tall tube-in-tube diagrid buildings

  • Khatami, Alireza;Heshmati, Mahdi;Aghakouchak, Ali Akbar
    • Earthquakes and Structures
    • /
    • 제19권3호
    • /
    • pp.197-214
    • /
    • 2020
  • Diagrid structures have been introduced as a fairly modern lateral load-resisting system in the design of high-rise buildings. In this paper, a novel diagrid system called tube-in-tube diagrid building is introduced and assessed through pushover and incremental dynamic analyses. The main objectives of this paper are to find the optimum angle of interior and exterior diagrid tube and evaluate the efficiency of diagrid core on the probability of collapse comparing to the conventional diagrid system. Finally, the seismic performance factors of the proposed system are validated according to the FEMA P695 methodology. To achieve these, 36-story diagrid buildings with various external and internal diagonal angles are designed and then 3-D nonlinear models of these structures developed in PERFORM-3D. The results show that weight of steel material highly depends on diagonal angle of exterior tube. Adding diagrid core generally increases the over-strength factor and collapse margin ratio of tall diagrid buildings confirming high seismic safety margin for tube-in-tube diagrid buildings under severe excitations. Collapse probabilities of both structural systems under MCE records are less than 10%. Finally, response modification factor of 3.0 and over-strength factor of 2.0 and 2.5 are proposed for design of typical diagrid and tube-in-tube diagrid buildings, respectively.

Diagrid Systems for Structural Design of Complex-Shaped Tall Buildings

  • Moon, Kyoung Sun
    • 국제초고층학회논문집
    • /
    • 제5권4호
    • /
    • pp.243-250
    • /
    • 2016
  • Today's architectural design trend based on the recognition of pluralism has led to multiple design directions for all building types including tall buildings. This contemporary design trend has produced many complex-shaped tall buildings, such as twisted, tilted, tapered and freeform towers. Among many different structural systems developed for tall buildings, the diagrid system, with its powerful structural rationale and distinguished aesthetic potential, is one of the most widely used systems for today's tall buildings. This paper studies structural performance of diagrid systems employed for complex-shaped tall buildings. Twisted, tilted, tapered and freeform tall buildings are designed with diagrid structures, and their structural performances are investigated. For the twisted diagrid study, the buildings are twisted up to 3 degrees per floor. In the tilted diagrid study, the angles of tilting range from 0 to 13 degrees. The impact of eccentricity is investigated for gravity as well as lateral loads in tilted towers. In the study of tapered diagrid structures, the angles of tapering range from 0 to 3 degrees. In the study of freeform diagrid structures, lateral stiffness of freeform diagrids is evaluated depending on the degree of fluctuation of free form. The freeform floor plans fluctuate from plus/minus 1.5 meter to plus/minus 4.5 meter boundaries of the original square floor plan. Parametric structural models are generated using appropriate computer programs and the models are exported to structural engineering software for design, analyses and comparative studies.

Stability of Diagrid Structures

  • Rahimian, Ahmad
    • 국제초고층학회논문집
    • /
    • 제5권4호
    • /
    • pp.263-270
    • /
    • 2016
  • In this paper, the stability requirements for diagrid and mega braced structures are examined. The role of the secondary bracing system for the stability of a diagrid structure is discussed. A simple procedure is proposed for the design of the secondary bracing system when it is required. As a case study, the design of the Hearst Tower diagrid and its secondary bracing system are presented.

Progressive Collapse and Seismic Performance of Twisted Diagrid Buildings

  • Kwon, Kwangho;Kim, Jinkoo
    • 국제초고층학회논문집
    • /
    • 제3권3호
    • /
    • pp.223-230
    • /
    • 2014
  • In this study the progressive collapse resisting capacities of tall diagrid buildings were evaluated based on arbitrary column removal scenario, and the seismic load-resisting capacities were investigated through fragility analysis and ATC 63 procedure. As analysis model structures both regular and twisted diagrid structures were designed and their load-resisting capacities were compared by nonlinear static and dynamic analyses. The analysis results showed that the progressive collapse potential of twisted buildings decreased as the twisting angle increased, but the seismic fragility or the probability of failure decreased as the twisting angle increased.

The Effect of Slenderness on the Design of Diagrid Structures

  • Mele, Elena;Imbimbo, Maura;Tomei, Valentina
    • 국제초고층학회논문집
    • /
    • 제8권2호
    • /
    • pp.83-94
    • /
    • 2019
  • Diagrid structures have emerged in recent decades as an innovative solution for tube tall buildings, capable of merging structural efficiency and aesthetic quality. This paper investigates the effect of the building slenderness (grossly quantified by means of the aspect ratio, i.e., the ratio between the height and the plan dimension) on the structural behavior and on the optimal design parameters of diagrid tall buildings. For this purpose, building models with different slenderness values are designed by adopting preliminary design criteria, based on strength or stiffness demands; in addition, a design method based on a sizing optimization process that employs genetic algorithms is also proposed, with the aim to compare and/or refine the results obtained with simplified approaches.

테이퍼드 다이아그리드 초고층 구조물의 형상 최적설계기법 개발 (A Development of a Shape Optimization Design Techniques for the Diagrid Tapered Tall-Building)

  • 한상을;이한주;유종혜;정소영
    • 한국강구조학회 논문집
    • /
    • 제23권3호
    • /
    • pp.349-356
    • /
    • 2011
  • 본 논문에서는 파라메트릭 기법을 이용한 최적설계 알고리즘을 사용하여 최근 들어 다양한 형태를 지니고 있는 비정형 초고층 구조물의 최적 다이아그리드 각도를 찾는 것에 대해 연구하였다. 다이아그리드는 비정형 초고층 구조물을 구성하는 대각방향의 부재로 수직하중과 수평하중에 대해 효과적으로 대응할 수 있는 구조 시스템으로써 다이아그리드의 각도를 최적화 하여 비정형 초고층 구조물의 최대강성을 찾는 것에 목적을 두었다. 본 연구에서 검증예제로 비정형 형상인 원통형 구조물과 테이퍼드 원형 구조물에 다이아그리드 최적설계 알고리즘을 적용하여 변위를 효과적으로 제어하는 다이아그리드의 최적각도를 검토하였다.

초고층 다이아그리드 노드의 최적설계과정 (Optimization Design Process of Diagrid Node for Tall buildings)

  • 김상대;배재훈;주영규;김영주;김도현
    • 한국강구조학회 논문집
    • /
    • 제23권2호
    • /
    • pp.211-220
    • /
    • 2011
  • 다이아그리드 구조시스템은 현재 초고층의 하나의 트렌드로써 미적일뿐 아니라 구조적으로 효율적인 시스템이다. 그러나 이러한 효율적인 다이아그리드가 실제적으로 시공이 어려운 데에는 접합부의 문제가 가장 크다. 접합부는 시공상 어려울 뿐만 아니라, 무엇보다 비용이 많이 들어가기 때문에 실질적으로 다이아그리드 구조를 채택하지 못하고 계획단계에서 그치는 경우가 많다. 본 논문에서는 다이아그리드 노드의 구조적인 물량을 절약하면서 구조적으로 효율적인 다이아 그리드 접합부 모델을 유한요소 해석을 통해서 제안하고 이를 실험에 직접 적용을 시켜 봄으로써 그 효율성을 검증하고자 한다.

Potentials of elastic seismic design of twisted high-rise steel diagrid frames

  • Kim, Seonwoong;Lee, Kyungkoo
    • Steel and Composite Structures
    • /
    • 제18권1호
    • /
    • pp.121-134
    • /
    • 2015
  • This paper is to investigate the potentials of the elastic seismic design of twisted high-rise steel diagrid frame buildings in the strong wind and moderate/low seismicity regions. First, the prototypes of high-rise steel diagrid frames with architectural plans that have a twist angle of 0 (regular-shaped), 1, and 2 degrees were designed to resist wind. Then, the effects of the twist angle on the estimated quantities and structural redundancies of the diagrid frames were examined. Second, the seismic performance of the wind-designed prototype buildings under a low seismicity was evaluated. The response spectrum analysis was conducted for the service level earthquake (SLE) having 43-year return period and the maximum considered earthquake (MCE) having 2475-year return period. The evaluation resulted that the twisted high-rise steel diagrid frames resisted the service level earthquake elastically and most of their diagrid members remained elastic even under the maximum considered earthquake.

Seismic Performance of Wind-Designed Diagrid Tall Steel Buildings in Regions of Moderate Seismicity and Strong Wind

  • Kim, Seonwoong;Lee, Kyungkoo
    • Steel and Composite Structures
    • /
    • 제14권2호
    • /
    • pp.155-171
    • /
    • 2013
  • This study analytically evaluated the seismic performance of wind-designed diagrid tall steel buildings in regions of moderate/low seismicity and strong winds. To this end, diagrid tall steel buildings with varying wind exposure and slenderness ratio (building height-to-width ratio) conditions were designed to satisfy the wind serviceability criteria specified in the Korean Building Code and the National Building Code of Canada. A series of seismic analyses were then performed for earthquakes having 43- and 2475- year return periods utilizing the design guidelines of tall buildings. The analyses demonstrated the good seismic performance of these wind-designed diagrid tall steel buildings, which arises because significant overstrength of the diagrid system occurs in the wind design procedure. Also, analysis showed that the elastic seismic design process of diagrid tall steel buildings might be accepted based on some wind exposures and slenderness ratios.

MOGA-Based Structural Design Method for Diagrid Structural Control System Subjected to Wind and Earthquake Loads

  • Kim, Hyun-Su;Kang, Joo-Won
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1598-1606
    • /
    • 2018
  • An integrated optimal structural design method for a diagrid structure and control device was developed. A multi-objective genetic algorithm was used and a 60-story diagrid building structure was developed as an example structure. Artificial wind and earthquake loads were generated to assess the wind-induced and seismic responses. A smart tuned mass damper (TMD) was used as a structural control system and an MR (magnetorheological) damper was employed to develop a smart TMD (STMD). The multi-objective genetic algorithm used five objectives including a reduction of the dynamic responses, additional stiffness and damping, mass of STMD, capacity of the MR damper for the integrated optimization of a diagrid structure and a STMD. From the proposed method, integrated optimal designs for the diagrid structure and STMD were obtained. The numerical simulation also showed that the STMD provided good control performance for reducing the wind-induced and seismic responses of a tall diagrid building structure.