• 제목/요약/키워드: Diagnostic tests

검색결과 781건 처리시간 0.034초

공기구동밸브 성능 진단 장비 개발 (Development of the Diagnostic System for the Performance of Air-Operated Valves)

  • 김윤철;강성기;박성근;김대웅;채장범
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.416-419
    • /
    • 2008
  • In order to ensure the safety, the performance evaluation of the safety-related components in a nuclear power plant such as air-operated valves. In this paper, the diagnostic system(MOVIDS $A^+$) for the performance of air-operated valves was developed. For this purpose, the characteristics of their operation and the methods of the diagnostic tests were reviewed. The setup and diagnostic functions of the system were mentioned. Its applicability was validated through the diagnostic tests of air-operated valves in nuclear power plants. This diagnostic system is now applied in nuclear power plants for performance tests.

  • PDF

Diagnostic accuracy of clinical tests to rule out elbow fracture: a systematic review

  • Giorgio Breda;Gianluca De Marco;Pierfranco Cesaraccio;Paolo Pillastrini
    • Clinics in Shoulder and Elbow
    • /
    • 제26권2호
    • /
    • pp.182-190
    • /
    • 2023
  • Elbow traumas represent a relatively common condition in clinical practice. However, there is a lack of evidence regarding the most accurate tests for screening these potentially serious conditions and excluding elbow fractures. The purpose of this investigation was to analyze the literature concerning the diagnostic accuracy of clinical tests for the detection or exclusion of suspected elbow fractures. A systematic review was performed using the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines. Literature databases including PubMed, Cumulative Index to Nursing and Allied Health Literature, Diagnostic Test Accuracy, Cochrane Library, the Web of Science, and ScienceDirect were searched for diagnostic accuracy studies of subjects with suspected traumatic elbow fracture investigating clinical tests compared to imaging reference tests. The risk of bias in each study was assessed independently by two reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 checklist. Twelve studies (4,485 patients) were included. Three different types of index tests were extracted. In adults, these tests were very sensitive, with values up to 98.6% (95% confidence interval [CI], 95.0%-99.8%). The specificity was very variable, ranging from 24.0% (95% CI, 19.0%-30.0%) to 69.4% (95% CI, 57.3%-79.5%). The applicability of these tests was very high, while overall studies showed a medium risk of bias. Elbow full range of motion test, elbow extension test, and elbow extension and point tenderness test appear to be useful in the presence of a negative test to exclude fracture in a majority of cases. The specificity of all tests, however, does not allow us to draw useful conclusions because there was a great variability of results obtained.

두 진단검사의 비교에 대한 민감도와 특이도의 다변량 메타분석법 (Multivariate Meta-Analysis Methods of Comparing the Sensitivity and Specificity of Two Diagnostic Tests)

  • 남선영;송혜향
    • Communications for Statistical Applications and Methods
    • /
    • 제18권1호
    • /
    • pp.57-69
    • /
    • 2011
  • 질병에 대한 새로운 진단검사 방법이 의학 연구자들에 의해 끊임없이 개발되고 있으며, 기존 진단검사 방법과 새로운 진단검사 방법을 비교하는 연구논문이 계속 출간되어 누적되고 있다. 메타분석법으로 다수 연구논문의 결과를 종합하여 정확성이 높은 진단검사에 대해 객관적인 결론을 내리게 된다. 이와같이 출간된 두 진단검사를 비교하는 각 연구논문은 각각 질병을 가진 개체와 질병을 가지지 않은 개체에 두 검사를 모두 실시하여 한 쌍의 민감도와 특이도를 구하여 비교한다. 이러한 연구논문의 결과를 종합하는 메타분석은 동일 개체에 실시한 두 검사로 인해 한 쌍의 민감도간의 연관성과 한 쌍의 특이도 간의 연관성을 고려한 메타분석법을 본 논문에서 제시한다. 논문예제 자료와 모의시험으로 메타분석 검정통계량의 효율성을 평가한다.

Quantile-based Nonparametric Test for Comparing Two Diagnostic Tests

  • Kim, Young-Min;Song, Hae-Hiang
    • Communications for Statistical Applications and Methods
    • /
    • 제14권3호
    • /
    • pp.609-621
    • /
    • 2007
  • Diagnostic test results, which are approximately normal with a few number of outliers, but non-normal probability distribution, are frequently observed in practice. In the evaluation of two diagnostic tests, Greenhouse and Mantel (1950) proposed a parametric test under the assumption of normality but this test is inappropriate for the above non-normal case. In this paper, we propose a computationally simple nonparametric test that is based on quantile estimators of mean and standard deviation, instead of the moment-based mean and standard deviation as in some parametric tests. Parametric and nonparametric tests are compared with simulations under the assumption of, respectively, normality and non-normality, and under various combinations of the probability distributions for the normal and diseased groups.

EVALUATION OF DIAGNOSTIC TESTS WITH MULTIPLE DIAGNOSTIC CATEGORIES

  • Birkett N.J.
    • 대한예방의학회:학술대회논문집
    • /
    • 대한예방의학회 1994년도 교수 연수회(역학)
    • /
    • pp.154-157
    • /
    • 1994
  • The evaluation of diagnostic tests attempts to obtain one or more statistical parameters which can indicate the intrinsic diagnostic utility of a test. Sensitivity. specificity and predictive value are not appropriate for this use. The likelihood ratio has been proposed as a useful measure when using a test to diagnose one of two disease states (e.g. disease present or absent). In this paper, we generalize the likelihood ratio concept to a situation in which the goal is to diagnose one of several non-overlapping disease states. A formula is derived to determine the post-test probability of a specific disease state. The post-test odds are shown to be related to the pre-test odds of a disease and to the usual likelihood ratios derived from considering the diagnosis between the target diagnosis and each alternate in turn. Hence, likelihood ratios derived from comparing pairs of diseases can be used to determine test utility in a multiple disease diagnostic situation.

  • PDF

Diagnostic performance of enzyme-linked immnosorbent assays for diagnosing paratuberculosis in cattle: a meta-analysis

  • Pak, Son-Il
    • 대한수의학회지
    • /
    • 제44권4호
    • /
    • pp.669-676
    • /
    • 2004
  • To evaluate the diagnostic accuracy of two commercial ELISA tests (Allied- and CSL-ELISA) for the diagnosis of Mycobacterium paratuberculosis in cattle, Meta-analysis using English language papers published during 1990-2001 was performed. Diagnostic odds ratios (DOR) were analyzed using regression analysis together with summary receiver operating characteristic (ROC) curves. The difference in diagnostic performance between the two ELISA systems was evaluated by using linear regression. Publication bias was assessed by funnel plot and linear regression. The pooled sensitivity and specificity were 44% (95% CI, 38 to 51) and 98% (95% CI, 96 to 99) for the random-effect model. The DOR between studies was heterogeneous. The area under the fitted ROC curve (AUC) was 0.72 for the unweighted and 0.77 for the weighted model. Maximum joint sensitivity and specificity for the unweighted and weighted model from their summary ROC curve were 70% and 75%, respectively. Based on the fitted model, at a specificity of 95%, sensitivity was estimated to be 52% for the unweighted and 57% for the weighted model. From the final multivariable model study characteristic, the country was the only significant variable with an explained component variance of 13.3%. There were no significant differences in discriminatory power, sensitivity, and specificity between the two ELISA tests. The overall diagnostic accuracy of two commercial ELISA tests was moderate, as judged by the AUC, maximum joint sensitivity and specificity, and estimates from the fitted model and clinical usefulness of the tests for screening program is limited because of low sensitivity and heterogeneous of DOR. It is, therefore, recommended to use ELISA tests as a parallel testing with other diagnostic tests together to increase test sensitivity in the screening program.

고압전동기 절연진단 해석 (II) (Analysis of Insulation Diagnostic Test for High Voltage motor (II))

  • 이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2107-2109
    • /
    • 1999
  • The insulation diagnostic tests was performed at local thermal power plants high voltage motor. The insulation diagnostic tests include measurements of insulation resistance, polarization index, AC current, $tan{\delta}$, partial discharges. This paper describes Insulation characteristics for high voltage motor which located by inside and outside.

  • PDF

Application of Diagnostic Laboratory Tests in the Field of Oral Medicine: A Narrative Review

  • Ji Woon, Park;Yeong-Gwan, Im
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.101-111
    • /
    • 2022
  • The purpose of laboratory tests in the field of oral medicine can be divided into two categories: (1) medical evaluation of patients with systemic diseases that are planning to receive dental care and (2) diagnosis of patients with certain oral diseases. First, laboratory tests are commonly used to evaluate patients with systemic diseases who need dental management. A combination of multiple tests is usually prescribed as a test panel to diagnose and assess a specific disease. Test panels closely related to oral medicine include those for rheumatoid arthritis, connective tissue disease/lupus, liver function, thyroid screening, anemia, and bleeding disorders. Second, laboratory tests are used as auxiliary diagnostic methods for certain oral diseases. They often provide crucial diagnostic information for infectious diseases caused by bacteria, fungi, and viruses that are associated with pathology in the oral and maxillofacial regions. Laboratory tests for infectious diseases are composed of growth-dependent methods, immunologic assays, and molecular biology. As the field develops, further application of laboratory tests, including synovial fluid analysis in temporomandibular joint disorders, salivary diagnostics, and hematologic biomarkers associated with temporomandibular disorders and orofacial pain conditions, is currently under scrutiny for their reliability as diagnostic tools.

Recent Advances in the Clinical Application of Next-Generation Sequencing

  • Ki, Chang-Seok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제24권1호
    • /
    • pp.1-6
    • /
    • 2021
  • Next-generation sequencing (NGS) technologies have changed the process of genetic diagnosis from a gene-by-gene approach to syndrome-based diagnostic gene panel sequencing (DPS), diagnostic exome sequencing (DES), and diagnostic genome sequencing (DGS). A priori information on the causative genes that might underlie a genetic condition is a prerequisite for genetic diagnosis before conducting clinical NGS tests. Theoretically, DPS, DES, and DGS do not require any information on specific candidate genes. Therefore, clinical NGS tests sometimes detect disease-related pathogenic variants in genes underlying different conditions from the initial diagnosis. These clinical NGS tests are expensive, but they can be a cost-effective approach for the rapid diagnosis of rare disorders with genetic heterogeneity, such as the glycogen storage disease, familial intrahepatic cholestasis, lysosomal storage disease, and primary immunodeficiency. In addition, DES or DGS may find novel genes that that were previously not linked to human diseases.

SARS-CoV-2 감염의 진단에 이용되는 검사실 테스트의 비교 (Comparison of Laboratory Tests Applied for Diagnosing the SARS-CoV-2 Infection)

  • 이창근;이동섭
    • 대한임상검사과학회지
    • /
    • 제54권2호
    • /
    • pp.79-94
    • /
    • 2022
  • COVID-19로 인한 높은 전염성과 호흡기 질환의 심각성 때문에, 전염의 확산을 더 잘 모니터링하고 예방하기 위해 경제적이고 정확한 검사가 필요하다. COVID-19 대유행의 초기 단계에서 SARS-CoV-2의 구조적 및 분자적 특성이 밝혀짐에 따라, 많은 COVID-19 진단 키트 제조업체들은 진단 테스트의 설계, 개발, 검증 및 구현에 적극적으로 투자했다. 현재, SARS-CoV-2에 대한 진단검사로써 신속한 항원, 특정 IgG 및 IgM 항체검사를 위한 면역 혈청학적 검사 그리고 분자 진단 검사가 가장 널리 사용되고 검증된 기술이다. 분자 진단 분석법은 SARS-CoV-2에 감염된 것으로 의심되는 개인에서 바이러스 RNA를 직접 검출하기 위한 gold standard이다. 항체 기반 혈청 검사는 지역사회에서 COVID-19 유병률을 결정하고 면역력을 획득한 개인을 식별하는 데 사용되는 간접 검사이다. 본 논문에서는 시판되고 FDA가 승인한 분자 및 면역학적 진단 측정을 평가하여 성능 특성을 분석하였다.